• Title/Summary/Keyword: KVN

Search Result 307, Processing Time 0.025 seconds

Parsec-scale radio properties of the X-ray selected AGN sample

  • Baek, Junhyun;Chung, Aeree;Schawinski, Kevin;Oh, Kyuseok;Wong, Ivy;Ricci, Claudio;Koss, Michael;Mushotzky, Richard;Smith, Krista
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.73.4-74
    • /
    • 2017
  • We report preliminary results from our radio study of X-ray selected complete AGN sample in the Local Universe (z < 0.05), using the KVN/KaVA. The main goal is to probe the parsec-scale radio properties of the X-ray selected AGNs, which has not been done systematically before. The BASS (Burst Alert Telescope AGN spectroscopic survey) sample from the Swift-BAT hard X-ray all-sky survey is the least biased AGN sample against dense gas/torus obscurations compared to optically selected AGNs, providing ideal targets to study the general properties of local AGNs in radio wavelengths. Combining our radio data with BASS X-ray/optical measurements, we will probe the relations of radio powers with the fundamental quantities of black holes such as bolometric luminosity, black hole mass, and Eddington ratio. Using these relations, we will discuss our current understandings of how accretions and jets of local AGNs are linked together, and what they imply for the nature of our AGN sample.

  • PDF

SMALL-SCALE GIGABIT VLBI OBSERVATION SYSTEM USING PC (PC를 이용한 소규모 기가비트 VLBI 관측시스템)

  • Oh, Se-Jin;Roh, Duk-Gyoo;Kim, Kwang-Dong;Chung, Hyun-Soo;Je, Do-Heung;Wi, Seog-Oh;Han, Seog-Tae;Kim, Hyun-Goo
    • Publications of The Korean Astronomical Society
    • /
    • v.20 no.1 s.24
    • /
    • pp.125-134
    • /
    • 2005
  • In this paper, we propose a small-scale Gigabit VLBI observing system for the Korean VLBI Network (KVN) under construction. The system consists of high-speed sampler, IP-VLBI board, PC-VSI board, and software correlator. Radio signal received by receiver is sampled by high-speed sample. at 1 Gsps (Gigabit sample per second) rate with 2 bits quantization. The digitized signal is recorded in PC and the software correlator does the cross correlation. IP-VLBI board will be used for the geodesy VLBI observation, while PC-VSI board is for the astronomical VLBI observation. The PC-VSI board adopts the VSI-H (VLBI Standard Interface Hardware). The proposed system is based on commercial PCs and therefore can be built inexpensively.

FREQUENCY STANDARD AND CLOCK SYSTEM IN VLBI (VLBI의 기준 주파수와 시각 동기 시스템)

  • OH SE-JIN;CHUNG HYUN-SOO;ROH DUK-GYOO;KIM KWANG-DONG
    • Publications of The Korean Astronomical Society
    • /
    • v.19 no.1
    • /
    • pp.93-99
    • /
    • 2004
  • In this paper, we describe a principle of the atomic frequency standard and clock system in VLBI(Very Long Baseline Interferometry). The hydrogen maser is a usual VLBI standard. During VLBI observations, signals emitted by distant sources of radio frequency energy(quasars) are received and recorded at several antennas. At each antenna(VLBI station), a very stable frequency standard(hydrogen maser) provides a reference signal which enables time-tagging to the quasar signals as they are being recorded on magnetic tapes or hard-disk modules. For each VLBl experiment, correlation of the time-tagged recorded information between the participating antennas is used to yield the arrival time differences of any specific quasar radio wave between the antennas. These time differences are used to calculate the relative antennas to each other. In this paper, we also introduce the KVN(Korean VLBI Network) atomic frequency standard and clock system.

Simultaneous Observations of SiO and $H_2O$ Masers toward Known Stellar SiO and $H_2O$ Maser Sources.II. Statistical Study

  • Kim, Jae-Heon;Cho, Se-Hyung;Kim, Sang-Joon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.51.2-51.2
    • /
    • 2010
  • We have carried out an extensive statistical analysis based on the results of simultaneous observations of SiO and $H_2O$ masers toward 166 known SiO and $H_2O$ maser sources using KVN_Yonsei radio telescope (Kim et al.2010, ApJS submitted). We investigate the distributions of the mean velocities and the intensity ratios between SiO and $H_2O$ maser emission including those between SiO v=1 and v=2,J=1-0 transitions according to type of evolved stars. We also investigate mutual relations between SiO and $H_2O$ maser properties(total flux densities and velocity structures etc.) according to stellar pulsation phases. Most of SiO masers appear around the stellar velocity (80 % within ${\pm}5km\;s^{-1}$), while $H_2O$ masers show a different characteristic compared with SiO masers (69% within ${\pm}5km\;s^{-1}$). In addition, we investigate a correlation between $SiO/H_2O$ maser emission and AKARIFIS flux density as well as the AKARI color characteristics of SiO and $H_2O$ observational results in the AKARIFIS two-color diagram.

  • PDF

한일공동VLBI상관기(KJJVC)의 운용 및 제어를 위한 Graphical User Interface(GUI) 설계 및 개발

  • Park, Seon-Yeop;Gang, Yong-U;No, Deok-Gyu;O, Se-Jin;Yeom, Jae-Hwan;Byeon, Do-Yeong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.45.2-45.2
    • /
    • 2010
  • 한국천문연구원은 한국우주전파관측망(Korean VLBI Network, KVN)에서 시험 운영 중인 한일공동VLBI상관기(Korea-Japan VLBI Correlator, KJJVC)의 핵심인 VLBI상관 서브시스템(VLBI Correlation Subsystem, VCS)을 제어하기 위해 CCS(Correlation Control Software)를 개발하였다. CCS는 명령어의 문법 검사를 하고, VCS와 TCP/IP 소켓으로 통신하여 명령어와 응답(reply)을 주고받으며, VCS의 실시간 요청에 대응하여 입력 지연 파라미터(delay parameter)를 자동으로 전달하는 소프트웨어이다. CCS는 사용자의 명령어를 local UNX FIFO를 통하여, 명령줄(Command Line)로 전달받고, 이러한 명령어들의 조합을 쉘 스크립트로 묶는 형태로 구성 되어있다. 그러나, 이렇게 명령어의 조합을 직접 편집하여 구성할 때, 입력할 명령어나 지연 파라미터의 구성이 복잡해지면, 스크립트에 필요한 명령이 문법에 맞지 않게 사용되거나, 일부 명령어가 누락될 수 있는 위험이 있다. 이러한 오류를 차단하고 작업 효율을 높이기 위하여, 상관 처리의 전체 운용 및 제어를 통합적으로 할 수 있는 사용자 인터페이스가 필요하다. 이를 위하여 KJJVC의 운용 및 제어를 위한 GUI를 설계하고 제작하였다. 개발된 GUI는 Python 언어를 기반으로 하는 wxPython 패키지를 사용하였으며, 사용자(Operator)가 명령어 문법이나 순서를 확인할 필요 없이, 관측 정보와 관측국 정보, 기록 매체 정보만 가지고 손쉽게 명령어의 조합을 생성해 주며, 시스템 초기화와 각종 정보의 입력이 직관적으로 이루어질 수 있도록 해 준다. 본 연구에서는 개발된 GUI의 설계 및 개발 과정과 시험운영에 대해 소개한다.

  • PDF

Maser and Molecular Line Surveys of 6.7GHz ClassII Methanol Maser Sources

  • Kang, Hyun-Woo;Kim, Kee-Tae;Oh, Chung-Sik;Bae, Jae-Han;Yun, So-Young;Park, Yong-Sun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.60.1-60.1
    • /
    • 2010
  • Methanol maser sources are believed to represent the earliest evolutionary stage of massive star formation. Pandian et al. (2007) recently made a very sensitive blind survey of 6.7GHz ClassII methanol maser towards the Galacitic midplane ($35^{\circ}$<1<$55^{\circ}$ & |b|<$0.5^{\circ}$) and found 86 maser sources. We carried out 22GHz $H_2O$ and 44.0 GHz $CH_3OH$ maser line surveys of them with KVN 21m and various (CO (2-1), $^{13}CO$ (2-1), $^{13}CO$ (1-0), $C^{18}O$ (2-1), CS (2-1), $HCO^+$ (3-2) and HCN (3-2)) molecular line surveys with SRAO 6m and TRAO 14m. we will present the preliminary results and discuss the implications for massive star formation.

  • PDF

한일공동VLBI상관기의 지연 보상 및 프린지 멈춤 알고리즘

  • No, Deok-Gyu;O, Se-Jin;Yeom, Jae-Hwan;Park, Seon-Yeop;Gang, Yong-U
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.45.1-45.1
    • /
    • 2010
  • 한국천문연구원과 일본 국립천문대는 공동으로 한일공동VLBI상관기(Korea-Japan VLBI Correlator, KJJVC)를 개발하였다. 이 상관기는 최대 16 관측국에 대하여 16 세트의 자기상관 및 120 세트의 상호상관을 계산할 수 있다. 각 관측국당 최대 8,192 Mbits/sec의 입력 데이터를 처리할 수 있으며, 8,192개의 주파수채널을 갖는 상관 스펙트럼을 약 25.4 밀리초~수초의 적분 시간으로 출력할 수 있는데, 최대 상관 출력 속도는 1.4GB/sec이다. 한편, 이 상관기는 한국우주전파관측망(KVN) 뿐만 아니라 동아시아VLBI관측망 및 우주공간VLBI관측망의 관측 데이터도 처리할 수 있도록 설계 제작되었으며, 최대 지연 추적 범위는 ${\pm}35,000km$이며, 보상 가능한 최대 기선 속도는 7.5km/sec이다. 현재 다른 VLBI관측망에서 사용하고 있는 타 상관기의 경우 지연은 2차 미분까지 보상하고, 프린지 위상은 3 단계로 보상하고 있는 것에 비하여, 한일공동VLBI상관기에서는 지연은 3차 미분까지 보상하여 지연 잔차를 최소화하고 프린지 위상은 16 단계로 세분하여 보상 수준의 정밀도를 최대화하였다. 이러한 지연 보상 및 프린지 멈춤 알고리즘을 상세히 소개하고 그 특성 및 장점을 보고한다.

  • PDF

Simultaneous Observations of SiO and $H_2O$ Masers toward Symbiotic Stars

  • Cho, Se-Hyung;Kim, Jae-Heon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.79.2-79.2
    • /
    • 2010
  • We present the results of simultaneous observations of SiO v=1, 2, J=1-0, $^{29}SiO$ v=0, J=1-0, and $H_2O$ $6_{16}-5_{23}$ maser lines performed with the KVN Yonsei 21 m radio telescope from 2009 Nov. to 2010 Jan (ApJ, 719, 126, 2010). We searched for these masers in 47 symbiotic stars and detected maser emission from 21 stars, giving the first time detection from 19 stars. Both SiO and $H_2O$ masers were detected from seven stars of which six stars are D-type symbiotic and one is an S-type star, WRAY 15-1470. In the SiO maser emission, the $^{28}SiO$ v=1 maser was detected from 10 stars, while the v=2 maser detected from 15 stars. In particular, the $^{28}SiO$ v=2 maser emission without the v=1 maser detection was detected from nine stars with its detection rate of 60 %, which is much higher than that of isolated Miras/red giants. The $^{29}SiO$ v=0 maser emission was also detected from two stars, H 2-38 and BF Cyg, together with the $^{28}SiO$ v=2 maser. We conclude that these different observational results between isolated Miras/red giants and symbiotic stars may be related with the presence of hot companions in a symbiotic binary system.

  • PDF

LINEAR POLARIZATION OF CLASS I METHANOL MASERS IN MASSIVE STAR-FORMING REGIONS

  • Kang, Ji-hyun;Byun, Do-Young;Kim, Kee-Tae;Kim, Jongsoo;Lyo, A-Ran;Kim, Mi-Kyung;Vlemmings, W.H.T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.46.1-46.1
    • /
    • 2017
  • Class I methanol masers are found to be good tracers of the interaction between outflows from massive young stellar objects with their surrounding media. Although polarization observations of Class II methanol masers have been able to provide information about magnetic fi elds close to the central (proto)stars, polarization observations of Class I methanol masers are rare, especially at 44 and 95GHz. We present the results of linear polarization observations of 39 Class I methanol maser sources at 44 and 95GHz. These two lines are observed simultaneously with one of the 21m Korean VLBI Network telescopes in single-dish mode. Approximately 60% of the observed sources have fractional polarizations of a few percent in at least one transition. This is the fi rst reported detection of linear polarization of the 44GHz methanol maser. We also observed 7 targets with the KVN in VLBI mode. We will present its preliminary results, too.

  • PDF

초고속 대용량 자료저장 시스템(Petascale Epoch Data Archive, PEDA)의 제어 소프트웨어 개발과 운용 시험

  • Park, Seon-Yeop;Gang, Yong-U;No, Deok-Gyu;O, Se-Jin;Yeom, Jae-Hwan
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.25.2-25.2
    • /
    • 2009
  • 한국천문연구원 한국우주전파관측망(Korean VLBI Network, KVN)에서 도입하여 시험운용중인 VLBI 상관서브시스템(VLBI Correlation Subsystem, VCS)은 한일공동 VLBI 상관기(Korea-Japan Joint VLBI Correlator, KJJVC)의 핵심 장비로서, 최대 16 관측국의 관측국 당 최대 8Gbps의 데이터를 처리할 수 있는 상관처리장치이다. VCS의 상관처리 결과는 총 4회선의 10GbE 광케이블을 통하여 UDP 프로토콜로 출력된다. 이 상관처리 결과는 광케이블 하나당 8개씩 총 32개의 상관 처리 블록(correlation block)으로 구성되며, 최대 출력속도는 1.4 GBytes/sec이다. 이 출력은 초고속 대용량 자료저장 시스템(Peta-scale Epoch Data Archive, PEDA)을 이용하여 저장하고 후속 자료처리를 위해 가공된다. PEDA는 총 4대의 고성능 자료 전송 및 저장 서버(writing server) 및 대용량 하드디스크 어레이로 구성된다. 상관처리 과정에 맞추어 PEDA의 writing 서버를 연계하여 제어하는 자료 전송 및 저장 제어 소프트웨어를 개발하였다. 이 소프트웨어는 핵심이 되는 전송 및 저장 프로세서와 이를 제어하는 제어프로세서로 구성된다. 전송 및 저장 프로세서는 개개의 상관 처리 블록에 대한 전송과 저장을 전담한다. 제어 프로세서는 총 32개의 상관 처리 블록을 처리하기 위하여 전송 및 저장 프로세스를 32개를 실행하고 각각의 상관 처리 블록에 해당하는 개별파라미터를 전달하는 전체적인 제어를 담당한다. 이 연구에서는 이 자료전송 및 저장 제어 소프트웨어의 설계 구성과 테스트 내용을 소개한다.

  • PDF