• Title/Summary/Keyword: KS 표준

Search Result 400, Processing Time 0.029 seconds

The Implementation of Active Leakage Current Detecting Algorithm based on 16 bit Signal Processor (16비트 신호처리 프로세서 기반 유효성분 누설전류 감지 알고리즘 구현)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.6
    • /
    • pp.605-610
    • /
    • 2016
  • The ELCB(: Earth Leakage Circuit Breaker) is the only way being used to prevent accidents from happening caused by electrical disaster. However, the existing ELCB has a limit to prevent damages to life and property due to a electric fire and a human body electric shock caused by the resistive leakage current, because of detecting the total leakage current in the block range of 15mA~30mA. It also has problems such as reduced productivity and reliability due to malfunctions by capacitive leakage currents. In this study, we have implemented the algorithm for the resistive leakage current detection technique and developed the resistive leakage current detection module based on a MSP430 processor, 16bit signal processor and this module can be operated in a desired block threshold within 0.03 seconds as specified in KS C 4613.

Experimental Study on Cooling Performance of A/C applied Fin-tube and PF Heat Exchangers (핀-관, 평행류 열교환기를 적용한 공조기의 냉방성능 실험연구)

  • Kwon, Young-Chul;Park, Yoon-Chang;Kwon, Jeong-Tae;Park, Gyung-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1789-1794
    • /
    • 2009
  • In the present study, the cooling performance characteristics on environment changes of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP on an air velocity, an indoor/outdoor temperature and an indoor/outdoor relative humidity were obtained. Fin types of PF heat exchanger were a triangler and squarer form. The experimental data for the three kinds of heat exchangers were measured using the air-enthalpy calorimeter. Performance of PF A/C was more excellent than that of a fin-tube A/C. Also, the performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin. As the air velocity, the indoor temperature and the indoor relative humidity increase, capacity and COP increase. And as outdoor temperature increases, capacity and COP decrease. But, the performance change on the outdoor relative humidity was insignificant.

A Study on the Prevention of Lightning Accidents According to Climate Change Response (기후변화에 따른 낙뢰사고 예방을 위한 제도 방안 연구)

  • Ju, Suk-won;Kim, Seong-Bin;Rie, Dong-Ho
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.48-55
    • /
    • 2020
  • The installation of lightning protection system has recently been increasing, but the amount of damage has still been increasing. In this study, survey (interview) and field conditions were conducted to identify the installation and safety standards of the lightning protection system. it was analyzed that the safety management system is non-existent at the stage of the design, manufacturing and construction of the site lightning protection system, and that the safety inspection of the lightning protection facility is not properly managed. It has been shown that lightning protection systems, that can solve these problems, need to be re-established according to the reality so that safety inspection can be carried out in accordance with safety standards such as management of safety certification products, operation of survey institutions, design, manufacturing, and construction of safety standards at a national level.

Evaluation of Homogeneity and Stability of Korean Mussel (Mytilus coruscus) Standards for Cadmium Analysis (카드뮴 분석용 홍합(Mytilus coruscus) 표준물질의 균질성 및 안정성 시험평가)

  • Lee, Ha-Eun;Lee, Jangho;Chung, David;Lee, Soo Yong;Park, Ki-Wan;Shim, Kyu-Young
    • Journal of Environmental Science International
    • /
    • v.28 no.11
    • /
    • pp.1041-1045
    • /
    • 2019
  • In this study, the KS A ISO Guide 35 was applied to develop analytical standards for heavy metal cadmium using the Korean mussel (Mytilus coruscus) and to evaluate the homogeneity and stability of the sample. Some of the crucial characteristics that reference materials must consist include homogeneity and stability of both intra- and inter-bottles. We tested homogeneity using ANOVA analysis and short-term stability using regression analysis. The variations of cadmium concentrations did not significantly differ between intra- and inter-bottles (F=0.41, p=0.90). For short-term stability verification, cadmium analysis results were not statistically significant as a result of the regression analysis (significance F=0.51, p=0.53). This suggests that we can not dismiss the null hypothesis that there is no significant variation in concentrations of cadmium over time. These results indicated that the cryogenic-milling process has statistically proven the short-term stability for materials from mussels in the chemical analysis of cadmium. Therefore, we propose that the Korean mussel's reference material developed for the proficiency test could be used as a tool to evaluate reliability and consistency in laboratories.

Comparative Study on the Evaluation of Liquefaction Resistance Ratio According to the Application of the Korean Standard for Cyclic Triaxial Strength Test (반복삼축강도시험의 KS 표준 제정에 따른 액상화 저항강도 평가 비교 연구)

  • Lee, Seokhyung;Han, Jin-Tae;Park, Ka-hyun;Kim, Jongkwan
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.9
    • /
    • pp.35-44
    • /
    • 2022
  • The cyclic triaxial strength test is commonly applied as a laboratory test for evaluating the liquefaction resistance ratio. However, the test procedure was not standardized in South Korea until recently; thus, the test results could significantly differ depending on the performer and apparatus, even when identical soil is used. In this study, the American and Japanese standards for the cyclic triaxial strength test were analyzed and the Korean standard was developed considering domestic circumstances. To verify the effectiveness of the standardization of liquefaction laboratory tests, several cases of cyclic triaxial strength tests were conducted and analyzed (1) following the Korean standard and (2) without following any specific instructions for the test procedure. Under (1), the deviation of the liquefaction resistance ratio dramatically decreased.

Designing of standard sizing system for hygienic masks (의약외품 마스크의 표준 치수 규격 개발)

  • Oh, Seol Young;Suh, Dong Ae
    • The Research Journal of the Costume Culture
    • /
    • v.30 no.4
    • /
    • pp.495-512
    • /
    • 2022
  • This study aims to design a new sizing system for hygienic masks to protect against COVID-19-related respiratory disorders. The product sizes were collected from 70 commercially available hygienic masks, and 18 head measurements were obtained from the three-dimensional (3D) scan data of 2,048 men and women aged 20 to 69 years from the 6th Size Korea Survey. The statistical analysis was performed using the IBM Statistical Package for the Social Sciences (SPSS) 28.0 program. The "bitragion-subnasale arc" and "menton-sellion length" were chosen as the key body dimensions for the hygienic mask sizing system. The linear regressions with 18 3D head measurements were analyzed, and it was determined that the key body dimensions were useful for statistically predicting other 3D head measurements related to hygienic masks. A new sizing system was proposed for two types of masks, "masks with a tight fit" and "masks with a loose fit," taking into account the existing Korean Industrial Standards (KS) and the shortcomings of the sizes of hygienic masks on the market. The sizing system for tight-fitting masks consisted of the key body dimensions, with their sizes indicated by a pair of numbers. The sizing system for loose-fitting masks consisted solely of the bitragion-subnasale arc, with their sizes denoted by letters such as S, M, and L (denoting small, medium, and large, respectively). Future studies should consider this mask sizing system for different age groups, such as children and adolescents.

A Study on the Analysis and Improvement of Medical Device Standards in Korea (국내 의료기기 표준 분석 및 개선에 관한 연구)

  • Yong Wan Kang;Kyung Ah Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.3
    • /
    • pp.204-210
    • /
    • 2023
  • This study focuses on analyzing medical device standards and regulatory requirements in the medical device industry, based on the Medical Device Act in Korea. The objective of this analysis is to determine whether the domestic standards for medical devices in Korea align with international and regional standards. Furthermore, it aims to identify the current application of domestic standards in ensuring the safety and essential performance of medical devices. The analysis revealed that out of a total of 281 domestic standards, 127 standards reference international standards. In terms of the application of domestic standards to specific items, there were 473 types of instruments/machines, 30 types of medical supplies, and 45 types of dental materials. However, the level of compliance with international standards among the domestic medical device standards was only 21%. Upon detailed analysis, general and collateral standards accounted for 24%, while particular standards accounted for 19%. This indicates a significant deviation from the latest international standards. On the other hand, the level of compliance with international standards was analyzed to be 60% for particular standards and 72% for general and collateral standards in Korean industrial standards (KS). Considering these results, the disparities between domestic standards and international standards underscore the need for discussions on domestic medical device regulation and standardization. In conclusion, this study emphasizes the significance of maintaining up-to-date medical device standards and ensuring their alignment with international standards to ensure the safety and quality of medical devices. The findings highlight the necessity for further efforts to strengthen the domestic standardization system in order to promote the development of safe and high-quality medical devices.

Performance Evaluation of Structure Strengthening Using Sprayed FRP Technique (분사식 FRP공법을 이용한 구조물 보강 성능평가)

  • Chang, Chun-Ho;Jang, Kwang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.4 s.56
    • /
    • pp.126-136
    • /
    • 2009
  • The sprayed FRP strengthening technique is combining the Glass fiber and Polyester resin in open air and spraying randomly at concrete's surface with high-speed compressed air. Then it strengthens the structures with a new technique evaluated the structural performance. We applied it to concrete beam and tested for flexural strength, depended on Korea Standard(KS F 2408). Then based on the result of flexural strength, the properties were proposed that applying to structures. Based on the experiment, we have evaluated structural performance by the experiment. 1/5 scale prestressed concrete I-beam were made by Korean Highway's typical drawing in 1993. With these test results, 49.8% increased in flexural strength, improvement of the behavior of serviceability state, and strengthening was surely effective for controlling deflection and crack of structure. Consequently, it can be summarized that Sprayed FRP technique has prospect to improve the performance of structure.

The Construction and Common Use of Old Document DB in the Foreign Countries (해외 소장 고문헌의 DB구축과 공동활용 방안)

  • Kang, Soon-Ae
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.42 no.3
    • /
    • pp.61-79
    • /
    • 2008
  • The purpose of this paper is to investigate the three aspects of the construction and common use of old document DB in the foreign countries: i) the processing of old documents, ii) the problem and improvement of DB systems of old documents. and iii) the common use of old document DB. Results from this research are as follows: The National Library of Korea(NLK) copied old documents in the foreign countries from 1982 to 2006 and published the brief catalog. The Reogang Publishing company issued four volumes catalogs of old document in Japan. The National Research Institute of Cultural Heritage(NRICH) investigated old books and published some catalogs of several organizations in Japan. America. France. and all. The National Institute of Korean History(NIKH) investigated old archives and published some catalogs of several organizations in Japan. The characteristics of the Korean Old and Rare Collection Information System(KORCIS) of the NLK, the Old Books Cultural Heritage in Overseas System of the NRICH. and the Korea History DB System and MF Catalog/ Image System of NIKH were described in the DB systems of old documents, the problems of DB systems were checked over and some alternatives were suggested. In the common use of old document DB, KORMARC format and description rules(draft) for archives should be revised to adopt a new standard such as KS editions. and all the institutes involved should thoroughly follow the standards. when creating bibliographic records and digitizing texts. It is necessary to educate and train the specialists of old documents. A government organization should be established to supervise all the procedures of developing technology for sharing digitized resources. using contents. and cooperating with the related internationl organizations and institutes.

Rapid Determination of Ginsenosides Rb1, Rf, and Rg1 in Korean Ginseng Using HPLC (HPLC를 이용한 고려인삼 중 진세노사이드 Rb1, Rf 및 Rg1의 신속분석 방법 개발)

  • Hong, Hee-Do;Choi, Sang-Yoon;Kim, Young-Chan;Lee, Young-Chul;Cho, Chang-Won
    • Journal of Ginseng Research
    • /
    • v.33 no.1
    • /
    • pp.8-12
    • /
    • 2009
  • A simple gradient HPLC method for rapid determination of major ginsenosides ($Rg_1$ and $Rb_1$) and unique ginsenoside (Rf) of Korean ginseng (Panax ginseng C.A. Meyer) was developed. Within 50min, three ginsenosides have been separated and identified on $\mu$-Bondapak $C_{18}$ column ($3.9{\times}300\;mm$, $10{\mu}m$) with gradient elution using water and acetonitrile as a mobile phase. The method was validated in terms of linearity, accuracy, and precision. The correlation coefficients ($r^2$) for calibration curves of ginsenosides were over 0.9997. The developed HPLC method was successfully applied to the analysis of ginseng samples and the recoveries of ginsenosides were in the range of $101.1{\sim}115%$ with RSD<3.2%. The developed method could be used for rapid evaluation of the ginsenosides $Rg_1$, $Rb_1$, and Rf.