• Title/Summary/Keyword: KS 표준시간-가열온도 곡선

Search Result 4, Processing Time 0.018 seconds

The Experimental Study on the Fire-Resistance of Fiber-Reinforced Ultra-High-Strength-Concrete (섬유보강 초고강도 콘크리트의 내화성능에 관한 실험적 연구)

  • Lee, Joo-Ha;Sohn, Yu-Shin;Lee, Seung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.407-408
    • /
    • 2010
  • This study investigated fire resistance performance for ultra-high-strength concrete columns reinforced with various fibers such as polypropylene, nylon, and steel fibers. 24 small size column specimens were tested with standard heating curve of KS F 2257-1 for 3 hours. The main parameters were the aggregate types, the length of polypropylene fibers, and the content ratios of each fiber.

  • PDF

A Study on Fire Resistance Using The Scale Experiments (축소실험을 통한 내화시험에 관한 연구)

  • Moon, Sung-Woong;Jeon, Jun-Pyo;Rie, Dong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.176-179
    • /
    • 2011
  • 국내에서는 방화구획을 설정하여 화재 확산 방지 및 재실자의 대피 시간을 확보하고 있다. 방화구획에 설치되는 방화문은 방화문의 내화시험방법(KS F 2268-1)에 따라 시험을 거쳐 성적서를 발급 받은 제품에 대해 설치하도록 의무화 하고 있다. 그러나 본 시험방법은 시험체 제작, 설치 및 의뢰시험비용 등 상당한 비용이 소요될 뿐 아니라 제작, 설치, 시험에 소요되는 시간 또한 길다. 축소실험장치는 목재방화문 개발 중 재료의 내화성능을 평가할 장치로 개발되었으며, 표준시간-가열 온도곡선을 상회하는 가열실험을 통해 재료의 내화성능 결과를 얻을 수 있다. 본 실험에서는 난연 또는 불연성능이 뛰어난 재료를 대상으로 실험하였으며, 그 결과 난연목재는 5분, 마그네슘보드와 내화 직물원단은 60분의 내화성능을 갖춘 것으로 확인되었다. 이 결과를 토대로 방화문의 내화시험방법과 상관성을 도출하여 목재방화문 개발의 지표로 활용 가능하게 되었다.

  • PDF

Analytical Study on the Fire Resistance of SC Composite Column (SC 합성기둥의 내화성능에 대한 해석연구)

  • Lim, Yoon Hee;Kang, Seong Deok;Oh, Myoung Ho;Kim, Myeong Han;Kim, Sang Dae
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.3
    • /
    • pp.335-344
    • /
    • 2007
  • The steel-concrete composite column (i.e., the SC composite column) supports large-gravity loads and simplifies the installation and removal of the work in pouring the concrete. The column takes advantage of the in-plant prefabrication of steel, the speed of erection of a steel structure, and the fire resistance of steel. This paper presents the results of a parametric study using heat transfer analysis and a P-M interaction curve, and compares these results with the experimental results to check the accuracy of the proposed parametric studies. The parametric studies, such as the study of the concrete ratio of an area and the fire protection thickness, provide information on the fire resistance of SC composite columns.

Investigation of Material Characteristics of Reinforced Concrete Beam After Exposure to Fire Test (화재 실험에 따른 철근 콘크리트 보의 재료특성 연구)

  • Ju, Min-Kwan;Park, Cheol-Woo;Oh, Ji-Hyun;Seo, Sang-Gil;Shim, Jae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.33-41
    • /
    • 2016
  • Concrete is inherently a good fire-resistance material among all other constrcution materials and protects the reinforcing steel inside. This study investigates the material characteristics of concrete and steel bar inside the full scale reinforced concrete(RC) beam exposed to fire test. The fire test specimen was 4 m long and the test was conducted under no loading condition following KS F 2257. Fire source is simulated by ISO 834 and number of thermocouples were installed to measure temperature variation of surfaces and inside of the beam. The measured compressive strength of cored specimen, which was exposed to fire test, was 11 MPa, about 66% lower than the strength before exposure. The yielding strength of steel bar also decreased about 75 MPa, about 17% lower. The measured temperature of protected steel bar was around $649^{\circ}C$, the critical limit, after 4 hour exposure.