• Title/Summary/Keyword: KS규격

Search Result 454, Processing Time 0.024 seconds

건축전기설비공사 표준시방서 개정(2)

  • 신효섭;정용기
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.4
    • /
    • pp.79-90
    • /
    • 2004
  • 1.1 관련시방 옥내배선공사와 관련된 사항에 대해서는 이 장에서 제시된 것을 제외하고 접지공사에 대하여는 10-4(접지설비공사)의 해당 규정에 따른다. 1.2 참조규격 1.2.1 한국산업규격 KS C IEC 60364 건축전기설비 KS C IEC 60085 전기절연재료의 내열성 평가 KS C IEC 60167 고체 전기절연재료의 절연저항 (중략)

  • PDF

Calculation of equivalent friction coefficients in V-belt (V벨트에서 상당마찰계수 계산)

  • Hong, J.P.
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.740-745
    • /
    • 2001
  • There are two kinds of method to calculate the equivalent friction coefficients at V groove. One is to consider the firction in radial direction. The other is to neglect the friection in radial direction. The values calculated from the two methods is different of which ratio is in the range from two times to five times. So it is necessary to study which is correct in the view of force equilibrium and machine design.

  • PDF

Evaluation of Minimum Extensibility Standard Requirements for Steel Reinforcement (철근 최소 연신율 규격에 대한 평가)

  • Lee, Jae-Hoon;Kim, Dong-Hyun;Choi, Jin-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.5
    • /
    • pp.559-567
    • /
    • 2011
  • Recently, many researches on high strength reinforcing steel have been conducted to construct optimum reinforced concrete structures. However, the studies have shown that high strength steel shows less elongation capacity than normal strength steel. Therefore, high strength reinforcing steel may not satisfy the minimum elongation requirement of current standards. Moreover, elongation measurements may be not standardized ones since each standard has its own requirements for minimum elongation and gage length. Therefore, the standards for reinforcing steel testing must be investigated to verify the validity of Korean Standard D 3504. This research aimed to compare the requirements for minimum elongation and gage length of the Korean, American, Japanese, European, and ISO Standards. Then, the study further investigated accuracy of the standards by tensile test of reinforcing steel. The study results showed that the Korean Standard has the strictest requirement. Based on the study results, the authors proposed modified minimum elongation requirements for general reinforcing steel and new requirements for seismic reinforcing steel.

The method for applying International Standards to Korean Industrial Standards in Construction fields - The standards of sampling and testing the fresh concrete - (건설분야에서 국내표준과 국제표준의 부합화 방안 - 콘크리트 시료채취와 시험방법에 대한 규격을 중심으로 -)

  • Lee Teck-wn;Kuk Chan-ho;Han Choong-hee
    • Korean Journal of Construction Engineering and Management
    • /
    • v.2 no.4 s.8
    • /
    • pp.107-116
    • /
    • 2001
  • As the international trade has been increased, unified worldwide standards are getting more important and necessary. At the TBT(Agreement on Technical Barrier to Trade) of WTO(World Trade Organization) and the CTI meeting of APEC(Asia-Pacific Economic Cooperation), they made an agreement with applying International Standards to National Standards gradually. In addition, ISO (International Organization for Standardization) established the ISO/IEC Guide 21, a guideline for applying International Standards to National Standards. In these environment, Korean Industrial Standards has to be prepared for it. This paper introduce the comparison between Korean Industrial Standards and ISO Standards about the standards of sampling and testing the fresh concrete, based on ISO/IEC Guide 21 by ISO and the Applying guideline by Korean Agency for Technology and Standards, and then discuss the problem about applying them. The overall objective is to establish the applying guideline on construction fields, which is civil and building engineering part(KS F) of Korean Industrial Standards.

  • PDF

Measures of International Standardization in Korean Landscape Drawing Practice (한국 조경제도의 국제표준화 방안)

  • Kim, Min-Soo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.4
    • /
    • pp.52-63
    • /
    • 2009
  • WTO/TBT aims to reduce impediments to trade resulting from differences between national regulations and standards. Where international standards exist or their completion is imminent, the Code of Good Practice says that standardizing bodies should use them, or the relevant parts of them, as a basis for any standards they develop. Drawing is a formal and precise way of communicating information about the shape, size and, features. In addition, drawing is a part of the universal language of engineering. However there are many differences between international landscape drawing standard ISO 11091 and Korean landscape drawing practice(KLDP). The result of a comparison of ISO 11091 with KLDP and suggestions for international standardization of KLDP are summarized as follows. First, Among the 33 kinds of conventions from ISO 11091, 2 similar kinds and 15 different kinds from KLDP and 16 kinds of conventions which exist only in ISO 11091 appeared-for the international standardization of KLDP, it is necessary to make an extensive alteration of KLDP. Second, Europe Unity countries accepted ISO 11091 and are using it as their national standard for landscape drawing. Even Japan has accepted ISO 11091 on their civil engineering drawings and is using it as their national standard. Therefore, we need to hasten KS standard enactment based on ISO 1091. Third, For the KS standard of construction drawings, the degree of international standardization is rising even though there are still differences from the ISO standard. Therefore, since the burden on the international standardization of KLDP is expected to be weighed, preparations should be quickly brought about in the practice fields. Fourth, Since in the landscape planting ordinances of local independent governments is the standard presented by categorizing trees into evergreen and deciduous, such parts should be modified and introduced when enacting the KS standard based on ISO 11091. Fifth, For the enactment of the KS standard for landscape drawings, a wide range of opinions should be collected by the relevant landscape organization by installing a committee, and based on its recommendation, an application for the KS standard enactment of landscape drawing should be made to the chief of Ministry of Knowledge Economy.

레미믹스트 콘크리트 KS F 4009

  • 한국레미콘공업협회
    • 레미콘
    • /
    • no.1 s.90
    • /
    • pp.93-109
    • /
    • 2007
  • 본 자료는 산업자원부 기술표준원에서 2007. 7. 1일부터 적용 예정인 KS F4009(레디믹스트 콘크리트) 규격으로서 회원사 업무에 도움주고자 전문 게재합니다.(해설서 제외)