• 제목/요약/키워드: KM research method

검색결과 587건 처리시간 0.029초

Measurements on the Propagation Path Loss Exponent at Maritime VHF Channel Using Single Carrier Signal (단일 반송파를 이용한 해상 VHF 채널의 전파 경로 감쇠 지수 측정)

  • Kim, Seung-Geun;Kim, Sea-Moon;Yun, Changho;Lim, Yong-Kon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제40권7호
    • /
    • pp.1450-1456
    • /
    • 2015
  • The received signal strengths according to the propagation distance between a transmitting shore station with a 53 m antenna hight and a receiving ship station with about 6m antenna hight from 700 m upto about 20 km are measured at ship's moving velocity of $5{\pm}1m/s$ using a single carrier signal at 150.0625MHz. In this paper, the path loss exponents at the propagation distance from 700 m to 20km are estimated via minimum-mean-square-error method using the measurements of the received signal strength, and the mean of the estimated path loss exponent become 3.79. The estimated propagation path loss exponents is similar to that calculated based on the field-strength values from 2 km to 20 km in Annex 2 of ITU-R P.1546-4, which is measuring results at maritime VHF at 100 MHz carrier frequency. Therefore, the estimated propagation path loss exponent shall be used as the expected path loss exponents for summer in costal area of South Sea of Korea.

Characteristics of the Extratropical Transition of Tropical Cyclones over the Western North Pacific using the Cyclone Phase Space (CPS) Diagram (북서태평양에서 저기압 위상 공간도법을 이용한 태풍의 온대저기압화 특성 분석)

  • Lee, Ji-Yun;Park, Jong-Suk;Kang, KiRyong;Chung, Kwan-Young
    • Atmosphere
    • /
    • 제18권3호
    • /
    • pp.159-169
    • /
    • 2008
  • The characteristics of the typhoon's extratropical transition (ET) over the western North Pacific area were investigated using the cyclone phase space (CPS) diagram method suggested by Hart (2003). The data used in this study were the global data assimilation prediction system (GDAPS) and NCEP data set. The number of typhoons selected were 75 cases during 2002 to 2007, and the three parameters were analyzed : the motion relative thickness asymmetry of the storm (B), the upper thermal wind shear and the lower thermal wind shear. Comparing the best-track data provided by the Regional Specialized Meteorological Center /Tokyo, the time of the ET based on CPS was 2~6 hours earlier than the best-track data. And it was shown that the 400- km and 30 kt wind radius of storm for the CPS method were better agreement than the previous suggested radius 500- km.

The Calculation of Lightning Flashover rate of 345kV/154kV Transmission Tower (345kV 및 154kV 송전철탑의 뇌사고율 예측계산)

  • Shim, E.B.;Woo, J.W.;Kwak, J.S.;Min, B.W.;Hwang, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.452-454
    • /
    • 2001
  • This paper described the calculation results of lightning flashover rate on the 345kV and 154kV transmission system of KEPCO. The back-flashover rate and shielding failure rate was calculated by FLASH(lightning flashover rate calculation program from IEEE) and KEPRI's own program which is based on the EGM(Electro Geometrical Model) method. The estimated lightning flashover late of 345kV transmission system of double circuit was 1.0 flash per 100km-year, and the lightning flashover rate of 154kV transmission line was 2.0 flash Per 100km-year approximately.

  • PDF

Strength analysis of mechanical transmission using equivalent torque of plow tillage of an 82 kW-class tractor

  • Kim, Taek-Jin;Kim, Wan-Soo;Kim, Yeon-Soo;Chung, Sun-Ok;Park, Seong-Un;Hong, Soon-Jung;Choi, Chang-Hyun;Kim, Yong-Joo
    • Korean Journal of Agricultural Science
    • /
    • 제46권4호
    • /
    • pp.723-735
    • /
    • 2019
  • The power-train is the most important component of an agricultural tractor. In this study, the strength of the driving gear transmission of an 82 kW-class tractor was analyzed using equivalent torque during plow tillage. The load measurement system consisted of an engine revolution speed sensor, torque-meters, revolution speed sensors for four axles, and pressure sensors for two hydraulic pumps. The load data were measured during plow tillage for four speed stages: F2 (2.78 km/h), F5 (5.35 km/h), F7 (7.98 km/h), and F8 (9.75 km/h). Aspects of the gear-strength such as bending stress, contact stress, and safety factors were analyzed under two torque conditions: the equivalent torque at the highest plow load for the F8 speed stage and the maximum engine torque. The simulation results using KISSsoft showed that the maximum engine torque conditions had a lower safety factor than did the highest equivalent torque condition. The bending safety factors were > 1 at all gear stages, indicating that gear breakage did not occur under actual measured operating conditions, nor under the maximum torque conditions. However, the equivalent torque condition in the contact stress safety factor was > 1, and the maximum torque condition was < 1 at the first gear pair. The method of analysis using the equivalent torque showed lower stress and higher safety factor than did the method using maximum torque. Therefore, when designing a tractor by applying actual working torque, equivalent torque method would support more reliable product development.

A Study on the Analysis of UWB Interference to WiMAX and Mitigation Method of Transmit Power Control (초광대역 시스템에 의한 WiMAX로의 간섭 및 송신 전력 제어 간섭 저감 방법 해석 연구)

  • Yoon, Young-Keun;Ju, Sang-Ho;Choi, Ik-Guen
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제18권9호
    • /
    • pp.1077-1082
    • /
    • 2007
  • This paper presents the analysis of the potential ultra-wideband(UWB) interference to WiMAX at 3.5 GHz bands and the mitigation method using transmit power control(TPC) of UWB system. UWB interference effect is evaluated with WiMax's outage probability over UWB density when multiple UWB systems and single WiMAX receiver distribute in unit area of 1$km^2$, When UWB distribution density is 20$devices/km^2$ and the dynamic range of TPC is 30 dB, UWB interference effect with TPC is decreased by 42 % rather than that without mitigation scheme. Finally, we describe that the proposed TPC is an effective method to mitigate UWB interference to WiMAX.

Reduction Effect of CO2 Emission on BIS Using Tier 3 Methodology - A Case Study on Daejun-Chungjoo Project - (Tier 3 방법론을 활용한 BIS 사업의 CO2 저감효과 분석 - 대전-청주 간 광역BIS 사업을 중심으로 -)

  • Chung, Younshik;Song, Taijin;Kim, Jeongwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제31권3D호
    • /
    • pp.375-381
    • /
    • 2011
  • This study presents an analysis of $CO_2$ emission reduction effect on bus information system (BIS) which is operated to improve various services of bus transit such as rapid and on-time service. Although the Intergovernmental Panel on Climate Change (IPCC) released three methodological types of models for analyzing the amount of greenhouse gas reduction, this study used the Tier 3 method that is the most concrete one. A case study was performed to a 8.3 km section of Daejun-Chungjoo BIS system, and dataset required to the Tier 3 method was obtained from ITS-based surveillance systems. The study result showed that the reduction effect of $CO_2$ on BIS operation was yearly $39.45tCO_2/km$. Therefore, such effect can be potentially useful to a measurement of effectiveness (MOE) of BIS projects hereafter.

Evaluation of the Lateral Influence Range on Temporary Structures for a Train Operating at 80km/h (시속 80km/h의 열차 운행시 가시설 구조물에 미치는 수평영향범위 평가)

  • Jong-Chul Kim;Yeong-Bae Kim;Tae-Hyun Hwang;Kang-Il Lee
    • Journal of the Korean Geosynthetics Society
    • /
    • 제22권2호
    • /
    • pp.35-45
    • /
    • 2023
  • In accordance with the urban development project, cases of constructing temporary wall structures for ground excavation in the vicinity of railway structures are increasing. In addition, the complaints about train vibration are also increasing from people living in large buildings newly built after installing the temporary wall structures. In order to solve this problem, a method for reducing train vibration is considered from the design stage of the building, and a vibration reduction system is installed on the structure when the building is newly constructed. However, the vibration reduction method established at the structure design stage can be determined through the results of field measurements or dynamic numerical analysis for a specific area, and there is a limit to evaluating whether the established vibration reduction method is appropriate due to the lack of objective research data. Therefore, in order to provide objective basic data when establishing a vibration reduction method, this study performed the dynamic numerical analysis for a operating train with a speed 80km/h by applying differently the depths of railway structures, the distances between railways and temporary wall structures, and ground conditions. It was found that the range of influence of a train operating at 80 km/h was within 4.5D of the lateral distance from the railway structure in the case of the condition where the temporary wall was installed.

BER Improvements of 0.96 Tbps WDM Signals through Optimal Parameter Values of Optical Phase Conjugator (광 위상 공액기의 최적 파라미터 값 도출을 통한 0.96 Tbps WDM 신호의 BER 개선)

  • Lee, Youngkyo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • 제11권1호
    • /
    • pp.79-88
    • /
    • 2015
  • In this paper, it is investigated that the limitation due to the asymmetry of optical power and chromatic dispersion with respect to optical phase conjugator (OPC) for compensating optical signal distortion in WDM system is overcomed by using OPC position offset and optimal dispersion coefficients of fiber sections, which depend on OPC position offset. It is confirmed that overall WDM channels are efficiently compensated by applying the optimal parameter values obtained from the proposed method into 24 channels ${\times}40$ Gbps WDM system with non zero - dispersion shifted fiber (NZ-DSF) of 1, 000 km, such as power penalties of inter-channel are reduce to almost 3.5 dB from the infinite value. It is also confirmed that the flexible design of WDM system with OPC is possible by using the optimal parameters, in which OPC is placed at ${\pm}15km$ from 500 km for efficiently compensating overall channels. Thus, the methods proposed in this research will be expected to alternate with the method of making a symmetrical distribution of power and local dispersion in real optical link which generates a serious problem if it was not made but it is the condition in the case of applying the OPC into multi-channels WDM system.

Estimation of High Resolution Daily Precipitation Using a Modified PRISM Model (개선된 PRISM 모형을 이용한 고해상도 일강수량 추정)

  • Kim, Jong Pil;Lee, Woo-Seop;Cho, Hyungon;Kim, Gwangseob
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • 제34권4호
    • /
    • pp.1139-1150
    • /
    • 2014
  • This study modified the Parameter-elevation Regression on Independent Slopes Model (PRISM) and investigated the applicability of the modified model (M-PRISM) in estimating $1km{\times}1km$ gridded daily precipitation over South Korea. The model parameters of M-PRISM were estimated by regression curves and were validated using the Jackknife method at the Korean Meteorological Administration (KMA) stations. The results indicate that M-RPISM shows better performance in estimating the frequency of daily precipitation than PRISM while M-PRISM has similar performance to PRISM in estimating the daily precipitation amount. Thus the M-PRISM model proposed in this study can be very useful to estimate high resolution daily precipitation.

A Development of Design Method for Deceleration Transition Curve Based on Vehicle Driving Characteristics (차량 주행특성을 고려한 감속 완화곡선 설계방법 개발)

  • Lee, Jeom-Ho
    • International Journal of Highway Engineering
    • /
    • 제10권3호
    • /
    • pp.97-107
    • /
    • 2008
  • I study for design criteria and research about Interchange diverging area of express highway and freeway, the most recent, at interchange diversion of express highway and freeway, design criteria and researches are focus on safety guarantee a point of view movement dynamics of vehicle and road geometric as to transition section, deceleration section, curve radius, nose section, outflow angle etc, that is, design criteria and research of Interchange diverging area have not consider a point of view movement dynamics of vehicle and road geometric and driver, so that I will be focus characteristic of runing speed on trasion curve. and I will consider vehicle running speed characteristics and study problem of Interchange diverging area design criteria. For this study, First, analysis meaning about theory of now design criteria, Second, look at vehicle running speed and traffic accident characteristics of Interchange diverging area, Third, propose new deceleration transition curve design method get along vehicle running speed characteristics of Interchange diverging area. new deceleration transition curve design method put out new outcoums, that is, I definite cause to safety new deceleration transition curve design method better than pressently, used design criteria of Interchange diverging area, especially, deceleration transition curve design criteria produced good result in the running speed 50km/h, 40km/h, that is inertia better than inertia of present used design criteria. and deceleration transition curve is extended better than present transition curve criteria, so that new deceleration transition curve design method safety is good better than the past method safety.

  • PDF