• Title/Summary/Keyword: KINEMATICS ANALYSIS

Search Result 632, Processing Time 0.028 seconds

What is the Appropriate Kettlebell Mass for a Kettlebell Swing? (케틀벨 스윙 시 적당한 케틀벨의 무게는 얼마일까?)

  • Kim, Bo Kyeong;Thau, Dao Van;Yoon, Sukhoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.4
    • /
    • pp.308-313
    • /
    • 2021
  • Objective: The purpose of this study was to investigate the effect of different kettlebell mass (30%, 40%, and 50% of the body mass) on kinematics and kinetic variables of kettlebell swing. Method: Total of 16 healthy male who had at least 1 year of kettlebell training experience were participated in this study (age: 31.69 ± 3.46 yrd., height: 173.38 ± 4.84 cm, body mass: 74.53 ± 6.45 kg). In this study, a 13-segments whole-body model (upper trunk, lower trunk, pelvis, both side of forearm, upperarm, thigh, and shank) was used and 26 reflective markers were attached to the body to identify the segments during the movement. A 3-dimensional motion analysis with 8 infrared cameras and 4 channeled EMG was performed to find the effect of kettlebell mass on its swing. To verify the kettlebell mass effect, a one-way ANOVA with a repeated measure was used and the statistical significance level was set at 𝛼=.05. Results: Firstly, in all lower extremity joints and thoracic vertebrae, a statistically significant change in angle was shown according to an increase in kettlebell mass during kettlebell swing (p<.05). Secondly, in both the up-swing and down-swing phases, the knee joint and ankle joint ROM showed a statistically significant increase as the kettlebell mass increased (p<.05) but no statistically significant difference was found in the hip joint and thoracic spine (p>.05). Lastly, the hamstrings muscle activity was statistically significantly increased as the kettlebell mass increased during up-swing phases (p<.05). Also, as the kettlebell mass increased in P4 of the down swing phase, the gluteus maximus showed a statistically significantly increased muscle activation, whereas the rectus femoris showed a statistically significantly decreased muscle activation (p <.05). Conclusion: As a result of this study, hip extension decreased and knee extension increased at 40% and 50% of body mass, and the spine also failed to maintain neutrality and increased flexion. Also, when kettlebell swings are performed with 50% of body mass, synergistic muscle dominance appears over 30% and 40% of body mass, which is judged to have a risk of potential injury. Therefore, it is thought that for beginners who start kettlebell exercise, swing practice should be performed with 30% of body mass. In addition, even in the case of experienced seniors, as the weight increases, the potential injury risk may increase, so it is thought that caution should be exercised when performing swings with 40% and 50% of body mass. In conclusion, it is thought that increasing the weight after sufficiently training with 30% of the weight of all subjects performing kettlebell swing is a way to maximize the exercise effect as well as prevent injury.

GG Tauri A: gas properties and dynamics from the cavity to the outer disk

  • Nguyen, Thi Phuong;Dutrey, Anne;Pham, Ngoc Diep;Chapillon, Edwige;Guilloteau, Stephane;Lee, Chang Won;Di Folco, Emmanuel;Majumdar, Liton;Bary, Jeff;Beck, Tracy L.;Coutens, Audrey;Denis-Alpizar, Otoniel;Melisse, Jean-Paul;Pietu, Vincent;Stoecklin, Thierry;Tang, Yei-Wen
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.38.2-39
    • /
    • 2021
  • I will presents the analysis of the gas properties of the protoplanetary disk surrounding the young low-mass (about 1.2Msun) triple star, GG Tau A. This work makes use of ALMA observations of rotational lines of CO (12CO, 13CO and C18O) together NOEMA observations of a few dozens of other molecules. While the CO emission gives information on the molecular layer close to the disk atmosphere, its less abundant isotopologues 13CO and C18O bring information much deeper in the molecular layer. I will present the analysis of the morphology and kinematics of the gas disk using the CO isotopologues. A radiative transfer model of the ring in CO isotopologues will also be presented. The subtraction of this model from the original data reveals the weak emission of the molecular gas lying inside the cavity. Thus, I am able to evaluate the properties of the gas inside the cavity, such as the gas dynamics, excitation conditions, and the amount of mass in the cavity. High angular resolution observations of CO reveals sprials induced by embedded planet(s) located near the 3:2:1 mean-motion resonance that help to explain the special morphology of the circumbinary disk. I also discuss some chemical properties of the GG Tau A disk. I report the first detection of H2S and C2S in a protoplanetary disk. The molecule abundance relative to 13CO of about twenties other molecules will also be given. In GG Tau A, the detections of rare molecules such as H2S and C2S have been probably possible because the disk is more massive (a factor about 3-5) than other disks where the molecules was searched. Such a large disk mass makes the system suitable to detect rare molecules and to study cold-chemistry in protoplanetary disks.

  • PDF

The Shape Preferred Orientation (SPO) Analysis in Estimation of Fault Activity Study (단층 활동 추적 연구에서의 Shape Preferred Orientation (SPO) 분석법)

  • Ho Sim;Yungoo Song;Changyun Park;Jaewon Seo
    • Economic and Environmental Geology
    • /
    • v.56 no.3
    • /
    • pp.293-300
    • /
    • 2023
  • The Shape Preferred Orientation (SPO) method has been used to analyze the orientation of fault motion, which is utilized as basic data for fault kinematics studies. The rigid grains, which as quartz, feldspar, and rock fragments, in the fault gouge are arranged in the P-shear direction through rigid body rotation by a given shear stress. Using this characteristic, the fault motion can be estimated from the SPO inversely. Recently, a method for securing precision and reliability by measuring 3D-SPO using X-ray CT images and examining the shape of a large number of particles in a short time has been developed. As a result, the SPO method analyzes the orientation of thousands to tens of thousands of particles at high speed, suggests the direction of fault motion, and provides easy accessibility and reliable data. In addition, the shape information and orientation distribution data of particles, which are by-products obtained in the SPO analysis process, are expected to be used as basic data for conducting various studies such as the local deformation of fault rocks and the fault generation mechanism.

Kinematic Effects of Newly Designed Knee-Ankle-Foot Orthosis With Oil Damper Unit on Gait in People With Hemiparesis

  • Park, Hyung-Ki;Kim, Tack-Hoon;Choi, Houng-Sik;Roh, Jung-Suk;Cynn, Heon-Seock;Kim, Jong-Man
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.64-73
    • /
    • 2013
  • The purposes of this study were to develop a new orthosis controlling ankle and knee joint motion during the gait cycle and to identify the effects of the newly designed orthosis on gait kinematics and tempospatial parameters, including coordination of the extremities in stroke patients. Fifteen individuals who had sustained a stroke, onset was 16 months, participated in this study. Before application of the measurement equipment the subjects were accustomed to walking on the ankle-foot orthosis (AFO) or stance control knee with knee flexion assisted-oil damper ankle-foot orthosis (SCKAFO) for 5 minutes. Fifteen patients were investigated for 45 days with a 3-day interval between sessions. Measurements were walking in fifteen stroke with hemiparesis on the 3D motion analysis system. Comparison of AFO and SCKAFO are gait pattern. The difference between the AFO and SCKAFO conditions was significant in the gait velocity, step length of the right affected side, stance time of both legs, step-length asymmetry ratio, single-support-time asymmetry ratio, ${\phi}$-thigh angle and ${\phi}$-shank angle in the mid swing (p<.001). Using a SCKAFO in stroke patients has shown similar to normal walking speeds can be attained for walking efficiency and is therefore desirable. In this study, the support time of the affected leg with the SCKAFO was longer than with the AFO and the asymmetry ratio of single support time decreased by more than with the AFO. This indicates that the SCKAFO was effective for improving gait symmetry, single-support-time symmetry. This may be due to the decrease of gait asymmetry. Thus, the newly designed SCKAFO may be useful for promoting gait performance by improving the coordination of the extremity and decreasing gait asymmetry in chronic stroke patients.

The Effect of Exercise Intensity on Muscle Activity and Kinematic Variables of the Lower Extremity during Squat

  • Jung, Jae-Hu;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.3
    • /
    • pp.197-203
    • /
    • 2017
  • Objective: The purpose of this study was to determine how exercise intensity affects muscle activity and kinematic variables during squat. Method: Fifteen trainers with >5 years of experience were recruited. For the electromyography (EMG) measurements, four surface electrodes were attached to both sides of the lower extremity to monitor the rectus femoris (RF) and biceps femoris. Three digital camcorders were used to obtain three-dimensional kinematics of the body. Each subject performed a squat in different conditions (40% one-repetition maximum [40%1RM], 60%1RM, and 80%1RM). For each trial being analyzed, three critical instants and two phases were identified from the video recording. For each dependent variable, one-way analysis of variance with repeated measures was used to determine whether there were significant differences among the three different conditions (p<.05). When a significant difference was found, post hoc analyses were performed using the contrast procedure. Results: The results showed that the average integrated EMG values of the RF were significantly greater in 80%1RM than in 40%1RM during the extension phase. The temporal parameter was significantly longer in 80%1RM than in 40%1RM and 60%1RM during the extension phase. The joint angle of the knee was significantly greater in 80%1RM than in 40%1RM at flexion. The range of motion of the knee was significantly less in 80%1RM than in 40%1RM and 60%1RM during the flexion phase and the extension phase. The angular velocity was significantly less in 80%1RM than in 40%1RM and 60%1RM during the extension phase. Conclusion: Generally, the increase of muscle strength decreases the pace of motion based on the relation between the strength and speed of muscle. In this study, we also found that the increase of exercise intensity may contribute to the increase of the muscle activity of the RF and the running time in the extension phase during squat motion. We observed that increased exercise intensity may hinder the regulation of the range of motion and joint angle. It is suitable to perform consistent movements while controlling the proper range of motion to maximize the benefit of resistance training.

Study on the design and the control of an underwater construction robot for port construction (항만공사용 수중건설로봇의 기구설계 및 제어에 관한 연구)

  • Kim, Tae-Sung;Kim, Chi-Hyo;Lee, Min-Ki
    • Journal of Navigation and Port Research
    • /
    • v.39 no.3
    • /
    • pp.253-260
    • /
    • 2015
  • There are many efforts to mechanize the process for underwater port construction due to the severe and adverse working environment. This paper presents an underwater construction robot to level rubbles on the seabed for port construction. The robot is composed of a blade and a multi-functional arm to flatten the rubble mound with respect to the reference level at uneven terrain and to dig and dump the rubbles. This research analyzes the kinematics of the blade and the multi-functional arm including track and swing motions with respect to a world coordinate assigned to a reference depth sensor. This analysis is conducted interfacing with the position and orientation sensors installed at the robot. A hydraulic control system is developed to control a track, a blade and a multi-functional arm for rubble leveling work. The experimental results of rubble leveling work conducted by the robot are presented in land and subsea. The working speed of the robot is eight times faster than that of a human diver, and the working quality is acceptable. The robot is expected to have much higher efficiency in deep water where a human diver is unable to work.

Kinematic Analysis of a Mastication Model Employing the 6-DOF Parallel Mechanism (6자유도의 병렬기구를 사용한 저작 모델의 기구학적 분석)

  • Khang, G.;Tsutsumi, Sadami
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.479-484
    • /
    • 1999
  • 본 연구에서는 사람의 턱 운동과 턱 사이에 작용하는 힘(혹은 압력)을 그대로 나타낼 수 있는 저작로봇을 개발하는 것을 궁극적인 목표로 한다. 이러한 저작로봇이 개발되면, 치과의사가 환자의 턱운동에 나타나는 병변을 진단하고 치료하는데 큰 도움이 될 것으로 사료된다. 또한 , 본 연구에 채택한 병렬기구(parallel mechanism)에대한 순기구학적( forward kinematics)분석은 일반적인 병렬기구의 실계에도 응용될 것으로 기대된다. 본 연구진이 1차적으로 설계한 모델은 베이스와 플랫폼(platform), 그리고 이 둘을 연결하는 3개의 다리로 구성되어 있다. 다리와 플랫폼은 3자유도의 관절로 다리와 베이스는 1자유도의 경첩 관절로 연결되어 있으며, 이 3개의 경첩 관절은 베이스 위의 수평면에서 직선을 따라 움직인다. 경첩 관절의 수평 변위와 세 다리의 길이가 주어졌을 때 플랫폼의 위치와 오리엔테이션을 구하는 순기구학의 해( 解)를 계산해내는 알고리즘을 개발하였다. 이 알고리즘의 특징은 매 순간 오차를 계산하여 이 오차가 줄어드는 방향으로 나아가도록 시간간격(time step)을 조절하는 것이다. 본 알고리즘은 현재 가장 보편적으로 사용되고 있는 뉴튼-렙슨 방법에 비하여 3가지 장점을 나타내고 있다. 우선 , 초기치(initial guess)에 관계없이 수렴한다는 것이다. 또한, 본 알고리즘은 뉴튼-렙슨 방법에 비하여 수렴속도가 훨씬 빠르며, 연산 시간이 매우 짧아져 실제적인 실시간 적용에 적합하다. 마지막으로, 뉴튼-렙슨 방법에서는 여러 개의 해 가운데 어느 곳으로 수렴할 지 예측 할수 없으나 본 알고리즘에서는 초기치에 가장 가까운 해로 수렴한다. 이러한 순기구학의 다중성(multiplicity)문제를 해결하기 위하여 두 개의 조건을 제시하였으며, 이를 적용한 시뮬레이션 결과에 의하면 항상 원하는 해(true solution)에 수렴할 수 있었다.발생량의 감소를 기대 할 수 있는 친환경기술로 유지관리비를 최소화할 수 있는 장점이 있었다. 않은 사람들 중 미래의 검진실행의지에 건강소식지가 영향을 미친 경우는 48.7%였다. 보건교육을 받은 후 유방암 자가검진 실천율은 사업군에서 53.9%로 받기 전의 27.3%보다 증가하였으나 대조군의 경우는 별 차이가 없었다. 연령별로는 60대가 가장 높았고 사업군에서 검진율의 증가분은 30대가 가장 컸다. 교육수준별로는 사업군은 고졸이, 대조군은 전문대졸이 가장 높았고 사업군에서 검진율의 증가분은 고졸에서 가장 컸다. 보건교육 후 유방암과 관련된 건강지식의 정도는 사업군이 3.7점으로 대조군보다 유의하게 높았으며, 유방암 자가검진법을 실천하는 사람들의 동기는 ‘일반 대중매체의 영향’이 가장 많았으며 건강소식지가 동기인 경우도 20.4%였다. 사업군에서 건강소식지가 유방암 자가검진법 실천에 영향을 미친 경우가 79.6%였으며 유방암 자가검진법에 관한 보건교육을 받고 실천하지 않은 사람들 중 미래의 실천의지에 건강소식지가 영향을 미친 경우는 43.6%였다. 이상의 소견에서 지역주민을 대상으로 인쇄매체를 통한 보건교육은 인쇄물만으로도 쉽게 실천 할 수 있는 유방암 자가검진법이 가장 효과적이었으며, 자궁암검진에 관해서도 검진을 받을 수 있도록 지역사회의 보건의료의 하부구조를 정비하여 제도적 장치를 마련하고 정보를 제공한다면 자궁암검진 실천율도 증가할 것이다.고 12.9% 의 발달율을 보여 유의적인 차이를 보이지 않았다. 이상의 결과로 보아 핵이식 수정란을 효율적으로 생산하기 위하여 수핵난자의 세포질에 ionomycin 과 DMAP 의 혼합처리로 탈핵난자의 활성화를 유도하는 것이 효율을 증진시킬 수 있었다고 본다. 또한 공핵수정란을 수정 후 90시간과 114시간 개별 배양하여 할구를 공핵체로 핵이식에 이용하였을 때도 그룹배양에 비하여 효율이 떨어지지 않음을 알 수 있었으며, 수정란의 할구

  • PDF

Optimized Methods to Maintain Motility and Viability in Normozoospermic Males (정자 운동성 및 수명 보존을 위한 최적 배양에 관한 연구)

  • You, Young-Ah;Mohamed, E.A.;Oh, Shin-Ae;Pang, Myung-Geol
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.36 no.1
    • /
    • pp.45-53
    • /
    • 2009
  • Objectives: To determinate the optimal culture condition to maintain lifespan in human sperm, we evaluated the effect of different temperature on sperm motility and viability up to 5 days in normal specimens. Methods: Ejaculated semen samples with normal semen parameters were gently washed in HEPES buffered Tyrod's-Albumin-Lactate-Pyruvate (HTALP) media. Each 5 ml of HTALP + 0.3% albumin with $1{\times}10^6$ sperm/ml was incubated for 5 days in $37^{\circ}C$, $22^{\circ}C$, and $4^{\circ}C$. The sperm motility and kinematics were analyzed using computer assisted sperm analysis (CASA), membrane integrity was assessed by hypoosmotic swelling test (HOST), and capacitation status was evaluated by chlorotetracycline (CTC) fluorescence pattern. Each parameter was measured on day 1, 3, and 5, respectively. Results: The motility, viability and live/uncapacitated pattern were demonstrated significantly in temperature- and time-dependent difference (p<0.05). While the sperm cultured for 1 day in each temperature was not significantly different, the sperm cell kept in $22^{\circ}C$ after 3 days were preserved sperm motility, viability, membrane integrity, and F pattern better than in other culture temperatures. Conclusions: HTALP can be used a basic medium for culture and longevity preservation, and sperm cell kept at $22^{\circ}C$ is beneficial for assisted reproductive techniques.

Effects of Visual Information Blockage on Landing Strategy during Drop Landing (시각 정보의 차단이 드롭랜딩 시 착지 전략에 미치는 영향)

  • Koh, Young-Chul;Cho, Joon-Haeng;Moon, Gon-Sung;Lee, Hae-Dong;Lee, Sung-Cheol
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.1
    • /
    • pp.31-38
    • /
    • 2011
  • This study aimed to determine the effects of the blockage of visual feedback on joint dynamics of the lower extremity. Fifteen healthy male subjects(age: $24.1{\pm}2.3\;yr$, height: $178.7{\pm}5.2\;cm$, weight: $73.6{\pm}6.6\;kg$) participated in this study. Each subject performed single-legged landing from a 45 cm-platform with the eyes open or closed. During the landing performance, three-dimensional kinematics of the lower extremity and ground reaction force(GRF) were recorded using a 8 infrared camera motion analysis system (Vicon MX-F20, Oxford Metric Ltd, Oxford, UK) with a force platform(ORG-6, AMTI, Watertown, MA). The results showed that at 50 ms prior to foot contact and at the time of foot contact, ankle plantar-flexion angle was smaller(p<.05) but the knee joint valgus and the hip flexion angles were greater with the eyes closed as compared to with the eyes open(p<.05). An increase in anterior GRF was observed during single-legged landing with the eyes closed as compared to with the eyes open(p<.05). Time to peak GRF in the medial, vertical and posterior directions occurred significantly earlier when the eyes were closed as compared to when the eyes were open(p<.05). Landing with the eyes closed resulted in a higher peak vertical loading rate(p<.05). In addition, the shock-absorbing power decreased at the ankle joint(p<.05) but increased at the hip joints when landing with the eyes closed(p<.05). When the eyes were closed, landing could be characterized by a less plantarflexed ankle joint and more flexed hip joint, with a faster time to peak GRF. These results imply that subjects are able to adapt the control of landing to different feedback conditions. Therefore, we suggest that training programs be introduced to reduce these injury risk factors.

Relative Navigation Study Using Multiple PSD Sensor and Beacon Module Based on Kalman Filter (복수 PSD와 비콘을 이용한 칼만필터 기반 상대항법에 대한 연구)

  • Song, Jeonggyu;Jeong, Junho;Yang, Seungwon;Kim, Seungkeun;Suk, Jinyoung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.3
    • /
    • pp.219-229
    • /
    • 2018
  • This paper proposes Kalman Filter-based relative navigation algorithms for proximity tasks such as rendezvous/docking/cluster-operation of spacecraft using PSD Sensors and Infrared Beacon Modules. Numerical simulations are performed for comparative analysis of the performance of each relative-navigation technique. Based on the operation principle and optical modeling of the PSD Sensor and the Infrared Beacon Module used in the relative navigation algorithm, a measurement model for the Kalman filter is constructed. The Extended Kalman Filter(EKF) and the Unscented Kalman Filter(UKF) are used as probabilistic relative navigation based on measurement fusion to utilize kinematics and dynamics information on translational and rotation motions of satellites. Relative position and relative attitude estimation performance of two filters is compared. Especially, through the simulation of various scenarios, performance changes are also investigated depending on the number of PSD Sensors and IR Beacons in target and chaser satellites.