Proceedings of the Korean Society for Noise and Vibration Engineering Conference
/
2000.11a
/
pp.667-673
/
2000
A number of issues related with the vibrational behavior of pretwisted rotating beams featuring anisotropic properties and incorporating adaptive capabilities are considered in this paper. The adaptive capabilities are provided by a system of piezoactuators bonded or embedded into the structure. Based on the converse piezoelectric effect and on the out of phase activation, boundary control moments are pizoelectrically induced at the beam tip. A feedback control law relating the induced bending moments with the kinematical response quantities appropriately selected is used, and its beneficial effects, considered in conjunction with that of the beam anisotropy and structural pretwist upon the eigenvibration characteristics are highlighted
The acoustical sources of intake and exhaust systems in fluid machines are often characterized by the source impedance and strength using linear frequency-domain modeling. In the case of the sources which are nonlinear and time-variant, however, the source parameters were sometimes incorrectly obtained. In this paper, the source model and direct measurement technique are modified in order to evaluate the effect due to nonlinear and periodically time-varying source character as well as the linear property of the reflectivity of in-duct fluid machine source. With a priori known kinematical information of the source, the types of nonlinear time-variant terms can be presumed by a simple physical model, in which there is practically no restriction on the form of the model. The concept of source impedance can be extendable by introducing the linear frequency response function for each nonlinear or time-variant input. Extending the conventional method and adapting the reverse MISO technique, it is possible to develop a direct method that can deal with the nonlinear time-variant source parameters. The proposed direct method has a novel feature that there is no restriction on the probability or spectral natures of the excited sound pressure data. The present method is verified by the simulated measurements for simplified fluid machines. It is thought that the proposed method would be useful in predicting the insertion loss or the radiated sound level from intake or exhaust systems.
The purpose of this study is to prove the kinematical characteristics of Deff motion, the high bar performance, in terms of flying phases so that we can provide basic sources for improving gymnastic performance. To do this, we selected and analyzed the performance of two athletes who did Deff motion in the high bar competition of male artistic gymnastic in the 22nd Universiade 2003 Daegu. We drew the conclusions from the kinematical factors that were came out through analyzing three-dimensional cinematography of the athletes' movements, by using a high speed video camera. To make a successful performance, a performer releases the bar at a height of a high bar vertically and at a height of 82cm horizontally, and the flying performance should be made without moving forward, as maintaining the proper balance, in order to rise over 118cm high during the flying phase. When the performer is releasing the bar, an increase of the vertical speed in the center of the body and extension of a knee joint and a hip joint contribute to increasing a flying height. And when the moving body is twisted, leaning to left side is caused by the winding movement of a knee joint, which causes an unstable bar grasp. To grasp the bar stably, just before releasing the performer should gain propulsive force from twisting rotation through increasing the speed of shoulder rotation. And before the peak point, the performer should make sure of a body rotation distance over $164^{\circ}$ so that he or she can do an aerial rotary performance smoothly. When grasping the high bar, the center of the body should be above the bar and the angle of shoulder rotation should be maintained close to $540^{\circ}$ simultaneously. he high point performance(S1) has more speed on an ascending phase and less speed on a descending phase than the low point performance (S2). At the peak point, both the rotation angle of the body and that of the shoulder in high point performance are big as well. In conclusion, it is shown that a performer can make a jump toward the high bar easily with the body straight because the performer can hold the upper part of the body erect early in a descending phase.
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
/
v.20
no.10
/
pp.151-157
/
2006
As people's living standard is being improved, human works are being replaced by robots. However, because most robots are used in process industry, fixed on the ground, we need to develop human robots that have wide applications. Currently many researches are being conducted on human robots with the object of replacing human works, but because of lack of relevant hardware, such robots are being applied limitedly to very simple tasks. To overcome the limitation, the present study developed a kinematical mechanism and a controller. Based on human kinematics, the shoulders and the arms were composed of master arms with 3 degree of freedom, and we reproduced motions similar to human ones through the characteristics of joint variables and experiment on the trajectory of the end effector.
Journal of the Korean Society for Precision Engineering
/
v.24
no.7
s.196
/
pp.133-138
/
2007
It is important to understand the characteristics of amputee gait to develop more advanced prostheses. The aim of this study was quantitatively to analyze the stair climbing task for the above-knee amputee with a prosthesis and to predict muscle forces and joint moments at musculoskeletal joints by dynamic analysis. The three-dimensional musculoskeletal model of lower extremities was constructed by gait analysis and transformation software for one above-knee amputee and ten healthy people. The measured ground reaction forces and kinematical data of each joint by gait analysis were used as input data during inverse dynamic analysis. Lastly, dynamic analysis of above-knee amputee during stair climbing were performed using musculoskeletal models. The results showed that summed muscle farces of hip extensor of amputated leg were greater than those of sound leg but the opposite results were revealed at hip abductor and knee flexor of amputated leg. We could also find that the higher moments at hip and knee joint of sound leg were needed to overcome the flexion moment caused by body weight and amputated leg. In conclusion, dynamic analysis using musculoskeletal models may be a useful mean to predict muscle forces and joint moments for specific motion tasks related to rehacilitation therapy..
International Journal of Precision Engineering and Manufacturing
/
v.9
no.1
/
pp.30-33
/
2008
Understanding the characteristics of amputee gait is key in developing more advanced prostheses. The aim of this study was to quantitatively analyze a stair-climbing task for transfemoral amputees with a prosthesis and to predict the muscle forces and joint moments at musculoskeletal joints using a dynamic analysis. A three-dimensional musculoskeletal model of the lower extremities was constructed from a gait analysis using transformation software for two transfemoral amputees and ten healthy people. The measured ground reaction forces and kinematical data of each joint from the gait analysis were used as input data for an inverse dynamic analysis. Dynamic analyses of an transfemoral amputee climbing stairs were performed using musculoskeletal models. The results showed that the summed muscle forces of the hip extensor of an amputated leg were greater than those of a sound leg. The opposite was true at the hip abductor and knee flexor of an amputated leg. We also found that higher moments at the hip and knee joints of the sound leg were required to overcome the flexion moment caused by the body weight and amputated leg. Dynamic analyses using musculoskeletal models may be a useful means to predict muscle forces and joint moments for specific motion tasks related to rehabilitation therapy.
The purpose of this study was to examine the kinematical characteristics of gymnasts who can perform the KOVACS skill, and to grope for the better KOVACS Piked motion. The subjects were 3 male national gymnasts and were filmed with video cameras. And kinematic data were collected from the event of maximum knee flexion to the re-grasp the bar after airborne motion during KOVACS Piked motion. And the following conclusion were drawn; S1 took the enough time and inadequate height for performing KOVACS Piked motion. S2 showed the inadequate time and height during airborne motion with the large forward-backward and left-right movement. S3 showed the better KOVACS Piked movement among gymnasts, but the weak point of S3 was the large left-right shift. Based on the above conclusions, the gymnasts should be trained the enough time and height for the effective airborne movement and to reduce the left-right movement.
This study intends to analyze the projection factors' difference on each record of women's javelin throwing. For this purpose, the research analyzed the best record and the lowest one of athletes in top 1~7 ranks respectively, who participated in 2009 Daegu Pre-Championship Meeting. For analyze kinematic factors, we analyzed their game photos mainly shot by 3 cameras installed in side places. The used analysis program was Kwon3D 3.1. Analysis variables were the projection velocity, angle, height, trunk lean angle, and supporting leg's knee angle. The results concluded as follows: Different record showed statistically significant differences(p<.05) in terms of horizontal velocity and resultant velocity. There were no statistically significant differences in the variables of projection angle, its height, trunk lean angle and knee angle of support leg. But for the analyzed results to each individual characteristics, the horizontal velocity, projection height, knee angle of support leg and trunk lean angle of release event appeared to have influence on record.
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
2009.06a
/
pp.58-58
/
2009
Uniformity related issues in chemical mechanical polishing (CMP) are within wafer non-uniformity (WIWNU), wafer to wafer non-uniformity (WTWNU), planarity and dishing/erosion. Here, the WIWNU that originates from spatial distribution of independent variables such as temperature, sliding distance, down force and material removal rate (MRR) during CMP, relies to spatial dependency. Among various sources of spatial irregularity, hardness and modulus of pad and surface roughness in sources for pad uniformity are great, especially. So, we investigated the spatial variation of pad surface characteristics using pad measuring system (PMS) and roughness measuring system. Reduced peak height ($R_{pk}$) of roughness parameter shows a strong correlation with the removal rate, and the distribution of relative sliding distance onwafer during polishing has an effect on the variation of $R_{pk}$ and WIWNU. Also, the results of pad wear profile thorough developed pad profiler well coincides with the kinematical simulation of conditioning, and it can contribute for the enhancement of WIWNU in CMP process.
Transactions of the Korean Society of Mechanical Engineers A
/
v.25
no.1
/
pp.70-80
/
2001
A cycloid reducer is one of the rotational velocity reduction equipments of machinery. It has advantages of the higher reduction ratio, the higher accuracy, the easier adjustment of transmission ratio and the smaller workspace than other kinds of reducer. A cycloidal plate gear is a main part of the cycloid reducer. Its tooth shape is peculiar because of gearing with the roller gear that has the several rollers on the circular line. And then it can be designed to contact all teeth to rollers. So, the cycloid reducer has the good characteristics in the dynamic properties and the zero-backlash in the contact motion. It can be used in robots, high-precision machines and high capacity machinery. This paper proposes a new approach for the shape design of the cycloidal plate gear and presents a Computer-Aided-Design program developed by the proposed method. The first part of this paper defines the two types of the cycloid reducers and explains their mechanisms. The second part defines the instant velocity centers for each type of the cycloid reducers and calculates the contact angles and the contact points by using te geometric relationships and the kinematical properties of the reducers. The third part generates the full shape of the cycloidal plate gear by the coordinate transformation technique. Finally, this paper presents two examples for the shape design of the cycloidal plate gear in order to prove the theory of the proposed method in this paper and the accuracy of the \"CycloGear Designer\".
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.