• Title/Summary/Keyword: KDS

Search Result 76, Processing Time 0.021 seconds

Updates of Korean Design Standard (KDS) on the wind load assessment and performance-based wind design

  • Han Sol Lee;Seung Yong Jeong;Thomas H.-K. Kang
    • Wind and Structures
    • /
    • v.37 no.2
    • /
    • pp.117-131
    • /
    • 2023
  • Korea Design Standard (KDS) will be updated with two major revisions on the assessment of wind load and performance-based wind design (PBWD). Major changes on the wind load assessment are the wind load factor and basic wind speed. Wind load factor in KDS is reduced from 1.3 to 1, and mean recurrence interval (MRI) for basic wind speed increases from 100 years to 500 years considering the reduction of wind load factor. Additional modification is made including pressure coefficient, torsional moment coefficient and spectrum, and aeroelastic instability. Combined effect of the updates of KDS code on the assessment of wind load is discussed with the case study on the specified sites and building. PBWD is newly added in KDS code to consider the cases with various target performance, vortex-induced vibration, aeroelastic instability, or inelastic behavior. Proposed methods and target performance for PBWD in KDS code are introduced.

Perceptual Vowel Space and Mental Representation of Korean Monophthongs (한국어 단모음의 지각적 모음공간과 심적 표상)

  • Choi, Yang-Gyu
    • Speech Sciences
    • /
    • v.10 no.2
    • /
    • pp.287-301
    • /
    • 2003
  • The purpose of this study was to examine whether the same vowel sounds are perceived differently by the two local dialect speakers, Seoul dialect speakers (SDS) and Kyungnam dialect speakers (KDS), whose vowel systems differ each other. In the first experiment SDS and KDS heard vowels synthesized in vowel space with F1 by F2 and categorized them into one of 10 Korean monophthongs. The results showed that SDS and KDS perceived the synthesized vowels differently. For example, /$\varepsilon$ versus /e/ contrast, ${\o}$/, and /y/ are differentiated by SDS, whereas they are perceptually confused by KDS. We also observed that /i/ could not be perceived unless the vowel synthesis included F3 or higher formants. In the second experiment SDS and KDS performed the similarity rating task of 10 synthesized Korean monophthongs. Two-dimensional MDS solution based on the similarity rating scores was obtained for each dialect group. The first dimension can be named 'vowel advancement' and the second 'vowel height'. The comparison of the two MDS solutions showed that the overall psychological distances among the vowels are shorter in KDS than SDS and that especially the distance between /$\Lambda$/ and /i/ is shorter in KDS than SDS. The result suggested that perception or mental representation of vowels depends on the vowel system of the listener's dialect or language. Further research problems were discussed in the final section.

  • PDF

Development of a Korean Diet Score (KDS) and its application assessing adherence to Korean healthy diet based on the Korean Food Guide Wheels

  • Lee, Myoungsook;Chae, Soo Wan;Cha, Youn-Soo;Cho, Mi Sook;Oh, Hea Young;Kim, Mi Kyung
    • Nutrition Research and Practice
    • /
    • v.7 no.1
    • /
    • pp.49-58
    • /
    • 2013
  • The most critical point in the assessment of adherence to dietary guidelines is the development of a practical definition for adherence, such as a dietary pattern score. The purpose of this study was to develop the Korean Diet Score (KDS) based on the Korean Food Balance Wheel and to examine the association of KDS with various lifestyle characteristics and biochemical factors. The dietary data of 5,320 subjects from the 4th Korean National Health and Nutritional Examination Survey were used for the final analysis. The food guide was composed of six food group categories; 'grain dishes', 'fish and meat dishes', 'vegetable dishes', 'fruits', 'milk' and 'oils and sugars'. Based on the recommended serving numbers for each group, the scores measuring adherence to this food guide were calculated from the dietary information from the 24-hour dietary recall questionnaire, and then its correlation with various characteristics was assessed. KDS was significantly associated with several clinical, lifestyle and socioeconomic factors as well as diagnosed disease history. The higher quintile group of KDS showed a significantly lower level in fasting blood glucose, systolic blood pressure, triglycerides, current smoking and drinking as well as higher leisure time activity, house income and education. Furthermore, the KDS quintile group of women was inversely associated with hypertension, osteoporosis and diabetes. A higher KDS quintile was characterized with a higher intake of several critical nutrients, such as Ca, Fe and vitamins as well as a desirable nutrition balance such as the ratio of macronutrients. Our results demonstrate that KDS is a beneficial tool in assessing the adherence to a healthy diet based on the Korean dietary guidelines. We suggest that KDS could be a useful indicator for evaluating the dietary balance of the Korean population.

Field Comparison of Korean Diffusive Sampler and Charcoal Tube Methods for Determination of Organic Vapors (공기중 유기용제 농도 측정에 있어서 국산 확산포집기와 활성탄관의 비교연구)

  • Cho, Sook Ja;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.1
    • /
    • pp.33-48
    • /
    • 1997
  • Korean diffusive sampler (KDS) and charcoal tube (CT) were used for sampling n-hexane, trichloroethylene and toluene in air KDS was made by Department of Environmental Health, SNU-SPH in 1995. Surveys were conducted at ten industrial plants with organic solvents. The relationship between two sampling methods was examined by linear regression analysis, and concentrations by two sampling methods were compared using paired t-test. The results are as follows: 1. The geometric means by CT and KDS methods were 3.26ppm and 3.32ppm for n-hexane, 5.07ppm and 6.34ppm for toluene, and 7.18ppm and 7.90ppm for toluene, respectively. There was no significant difference between results by CT and KDS methods in three organic vapors (p>0.05). When linear regression analysis was performed, two sampling methods were highly related ; correlation coefficients were 0.98, 0.90 and 0.96 for n-hexane, toluene and trichloroethylene, respectively. 2. Airborne concentrations of n-hexane (n=21) were below 0.5 TLV level. The GM by two methods were almost same (3.09 ppm). And there was no significant difference between results by two methods (p>0.05). 3. Since toluene and trichloroethylene concentrations showed several levels, appropriate sampling rates were applied for each level. The GM of toluene concentrations by two methods at 0.5 TLV level were 3.75ppm and 5.48ppm. The KDS method overestimated the toluene concentrations at 0.5 TLV level (p<0.05). The GM values of toluene concentrations at 1 TLV level were 31.80ppm and 25.38ppm and at 2 TLV level were 64.13 ppm and 51.37 ppm. The KDS method underestimated concentration at both level (p<0.05). For trichloroethylene, the GM at 0.5 TLV level were 4.97 ppm and 7.11ppm. The KDS method overestimated the concentration of trichloroethylene (p<0.05). In conclusion, concentrations of three organic vapors measured by CT and KDS were not significantly different and results by two methods were highly related. But at contain concentrations, the levels by method were significantly different. Therefore, it is suggested that sampling rate of KDS should be studied simultaneously using CT method for organic vapors.

  • PDF

Effect of Stirrup Spacing of Columns and an Additional Wall other than Core Walls on the Seismic Performance of Piloti-type Buildings (코어 외 추가 벽체와 기둥 띠철근 간격이 필로티 건물의 내진성능에 미치는 영향)

  • Lee, Soo Jeong;Kim, Taewan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.171-181
    • /
    • 2024
  • For low-rise piloti-type buildings that suffered significant damage in the Pohang earthquake, the seismic performance of those designed by codes issued before and after the earthquake has been recently revised. This study started with the expectation that many of the requirements presented in the current codes may be excessive, and among them, the spacing of column stirrup could be relaxed. In particular, the recently revised design code of concrete structures for buildings, KDS 41 20 00, suggests that the column stirrup spacing is 1/2 of the minimum cross-sectional size or 200 mm, which is strengthened compared to KBC 2016, but relaxed than the current KDS, 41 17 00, which is 1/4 of the minimum size or 150 mm. As a result of the study, it was found that the target performance level was sufficiently satisfied by following the current standards and that it could be satisfied even if the relaxed spacing was followed. Therefore, the strict column stirrup spacing of KDS 41 17 00 could be relaxed if a wall other than core walls is recommended in the current guideline for the structural design of piloti-type buildings.

Evaluation of the Lap Splice Strengths of High Strength Headed Bars by Flexural Tests of RC Beams (RC 보의 휨실험을 통한 고강도 확대머리철근의 겹침이음 강도 평가)

  • Lee, Ji-Hyeong;Jang, Duck-Young;Kim, Seung-Hun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.247-255
    • /
    • 2022
  • In this paper, a bending test was conducted on beams with two lap splice details when the effective depth of tensile high strength headed bars overlapped is the same and different. Through bending test, the lap splice performance of the high-strength headed bars was evaluated, and the applicability of the KDS-2021 design formula was evaluated. In the LS specimens with lap splice details where the high strength bars had the same effective depth, all specimens with 1.3 times or more of the development length of the KDS-2021 equation and 1 times or more of the ACI318-19 had the flexural failure mode after the ductile behavior to ensure sufficient lap splice performance. For specimens with details of lap joints between headed bars with different effective depth, when lap splice length is calculated by the KDS-2021 formula, the flexural stress may be transmitted so that the flexural strength at the cross section with the large effective depth and the cross section with the small effective depth becomes similar.

Survey on the Application of Standards and Specifications in Munitions Companies (II) (군수업체에서의 표준·규격 활용실태 조사 연구 (II))

  • Choi, Ki-In;Park, Il-Gwang;Kim, Sung-Kwang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1597-1602
    • /
    • 2011
  • To understand current status for the utilization of Korean military specifications(KDS) and other standards/specifications in munitions companies, we have surveyed 150 companies mainly related with electrical and electronic industry. Most of the companies have expected that the harmonization of KDS and KS would bring a positive effect on their business, especially from the point of quality control, productivity increase, the reduction of expenditure for standard management and so on. This survey result will help to build more user-friendly management system for KDS as well as KS.

Seismic Fragility of Low-rise Piloti Buildings Designed According to KDS 41 17 00 (KDS 41 17 00에 따라 설계된 저층 필로티 건물의 지진 취약도)

  • Joo, Changhyeok;Kim, Taewan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.49-58
    • /
    • 2022
  • The 2017 Pohang earthquake caused severe damage to low-rise piloti buildings. The damage was caused mainly by column shear failure, and some core walls were as well. The damaged piloti buildings in Pohang City could be relieved if they were designed correctly according to the standards at that time. However, the post-earthquake investigation revealed design, construction, and permission problems. To solve the problems, the Piloti Building Structure Design Guidelines that include strict specifications were published in 2018. Separately, KDS 41 17 00, the seismic design standard for buildings, was enacted in 2019 and it included the guideline contents. Therefore, at least after the publication of the guidelines, piloti buildings, designed by the standard and guidelines, can be expected to possess better seismic performance than existing piloti buildings. To confirm this, the probability of exceedance for several damage state thresholds was estimated for existing and designed piloti buildings. As a result, the probability of damage of designed piloti buildings was very low compared to existing ones. Consequently, it was confirmed that the guideline and standard adequately supplement the structural fragility of existing piloti buildings.

Evaluation Methods of Cyclic Shear Stress Ratio for the Assessment of Liquefaction in Korea (국내 액상화 평가를 위한 진동전단응력비 산정)

  • Yoo, Byeong-Soo;Bong, Tae-Ho;Kim, Sung-Ryul
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.6
    • /
    • pp.5-15
    • /
    • 2019
  • Usually, the cyclic shear stress ratio (CSR) for the assessment of liquefaction has been determined by performing ground response analysis or adopting simplified method suggested by Seed & Idriss with some modifications. In order to analyze the applicability of the CSR evaluation methods, the present study performed one-dimensional equivalent linear analysis and evaluated CSR based on design codes from FHWA, JRA, and KDS. The comparison of the CSR obtained from each code showed that the CSR from KDS showed the largest error with the analysis results. The reason is because KDS has an error, which defines the stress reduction coefficient applying the maximum acceleration at each depth, not the maximum cyclic shear stress mobilized in the soil.

Axial Compression of Stub Columns for Concrete-filled Square Steel Tubes (일축 압축력을 받는 콘크리트충전 각형강관 단주의 구조적 거동)

  • Yoo, Yeong-Chan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.617-624
    • /
    • 2021
  • Concrete-filled steel tubular columns can improve the strength and deformation capacity of structures, thereby enabling the development of efficient structures. The Korean design standard (KDS41) regarding concrete-filled steel tubular structures, established by the architectural institute of Korea in 2005, was revised in 2009 and 2016. The objective was to understand the compressive strengths and deformation capacity of stub columns for concrete-filled square steel tubes under uniaxial compression and validate the KDS41's standard code for necessary corrections. Experiments were conducted on 26 specimens with parameters, such as the width-thickness ratio of cold-formed square tubes. The following values of the stub columns for concrete-filled square steel tubes were obtained: compressive strengths, relationship between the axial load and axial displacement, and failure modes. An analysis of these results enabled an understanding of the concrete-filled effect and the influence of the wide-thickness ratio. The compressive strengths of filled concrete saw a 9% increase compared to a state of uniaxial stress, which must be noted in a future edition of KDS41. After benchmarking the results regarding square steel tubes generated by cold forming to the guidelines provided by the KDS41, the KDS41's value of 2.26 for the limiting width-to-thickness ratio for the compact section was found to be inflated. With a safety concern, this paper proposes a more conservative value of 1.35.