• Title/Summary/Keyword: KAERI

Search Result 1,553, Processing Time 0.032 seconds

A Study on the Treatment of Radioactive Liquid Wastes using Synthetic textile by Air Intake System (공기유입시스템에서의 섬유매체에 의한 방사성액체폐기물 처리에 관한 연구)

  • 김태국;이영희;안섬진;손종식;홍권표
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.101-104
    • /
    • 2003
  • In this study based on the mass transfer theory, experiments for the evaporation rates depending on various conditions were carried out through the operation of the existing Natural Evaporation Facility in KAERI. Evaporation media were made of the cotton and polyester. Air circulation in the facility was forced by exhausting fans. The evaporation rate and the decontamination factor were calculated by the result of experiment. The evaporation rate increased as the flow rate of air supply, the feed rate of liquid waste, and the temperature of supplied air increased. As for the humidity of supplied air, the evaporation rate was getting higher as the humidity was getting lower. As the result of this study, operation conditions of the Natural Evaporation Facility are optimized as follows : The air temperature above $8^{\circ}C$, the air humidity below 70%, the air flow rate 1.14-1.47 m/sec, and the liquid waste feed rate $4.6{\ell}/hr\cdotm^2$. The decontamination factor and the radioactivity are $5.1{\times}10^3$and $4.7{\times}10^{-13}{\mu}Ci/\textrm{m}{\ell}$ respectively, at the above mentioned optimum operation conditions. The air factor in the Dalton's equation for evaporation was determined from results of experiment on the temperature, the humidity, and the flow rate of supplied air as following : $[\textit{Eh}=(0.018 + 0.0141\textitv) {\delta}textitH]$

  • PDF

Study on the Safety Analysis on the Cooling Performance of Hybrid SIT under the Station Blackout Accident (발전소 정전사고 시 Hybrid SIT의 냉각성능 평가를 위한 안전해석에 관한 연구)

  • Ryu, Sung Uk;Kim, Jae Min;Kim, Myoung Joon;Jeon, Woo Jin;Park, Hyun-Sik;Yi, Sung-Jae
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.64-70
    • /
    • 2017
  • The concept of Hybrid Safety Injection Tank (Hybrid SIT) proposed by the Korea Atomic Energy Research Institute (KAERI) has been introduced for the purpose of application to the Advanced Power Reactor Plus (APR+). In this study, the SBO situation of the APR+ was analyzed by using the MARS-KS code in order to evaluate whether the operation of the Hybrid SIT has an effect on the cooling performance of the Reactor Coolant System (RCS). According to the analysis, when the actuation valve on the pressure balancing line (PBL) is opened, the Hybrid SIT's pressure rises rapidly, forming equilibrium with the RCS pressure; subsequently, a flow is injected from the Hybrid SIT into the reactor vessel through the direct vessel injection (DVI) line. The analysis showed that it is possible to keep the core temperature below melting temperature during the operation of a Hybrid SIT.

A Study on Non-proportionality of Phoswich Detector Using Monte Carlo Simulation (몬테칼로 전산모사를 이용한 Phoswich 계측기의 비선형성 연구)

  • Kim, Jae-Cheon;Kim, Jong-Kyung;Kim, Soon-Young;Kim, Yong-Kyun;Lee, Woo-Gyo
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.263-268
    • /
    • 2004
  • Using the Monte Carlo simulation, a study on the lion-proportionality of the prototype phoswich detector with $2'{\times}2'$ CSI(Tl) and plastic scintillator, which was made by KAERI, has been carried. The defector response functions (DRFs) calculated by simulations were compared with the experimental measurement on the $^{137}Cs\;and\;^{60}Co$. To precisely simulate the DRF for the phoswich, the CSI(Tl) non-proportionality was calculated using the electron response and the simplified electron cascade sequence for treating the photoelectric absorption event. The resulting DRFs of $^{137}Cs\;and\;^{60}Co$ sources obtained by simulations were compared with experiments for verification. For $^{137}Cs$, gamma-ray responses simulated by MCNP5 are generally good agreement with the measured ones. But the DRF of $^{60}Co$ does not match well with the results of experiment in the energy region below second peak due to the coincidence effect of two gamma-rays (1.17 MeV and 1.33 MeV). Through the analysis of the non-proportionality of CsI(Tl) in the prototype phoswich, the improved DRFs considering non-proportionality were produced and the simulation results were verified using the experimental measurements. However, to more precisely reproduce the DRF for the phoswich, further studies in relation to the electron channeling effect and the Doppler broadening effect of a scintillator are still needed as well as considering that effect of the transfer contribution.

Development of TLD Algorithms by Monochromatic Fluorescence Radiations and Continuous Spectrum X-rays (단일에너지 형광 X선 및 연속 스펙트럼 X선장에 의한 TLD 알고리즘 개발)

  • Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.159-174
    • /
    • 1998
  • Personal dosimetry system is required to measure the personal dose equivalent accurately in a wide range of radiation fields, but the dose evaluation algorithms have been developed with the X-ray fields described in MOST Ordinance (equivalent to the ANSI N13.11) from which the actual fields to be monitored may be significantly different. To evaluate the dose more accurately when workers are exposed to the non-ANSI N13.11 radiation fields, two algorithms for monochromatic radiations (one algorithm was used for various ratios of TL dosimeter and the other for matrix approximation) were developed with the experimental data of the energy responses of the $CaSO_4:Dy$ TL materials irradiated by monochromatic X-ray fields recently established in KAERI, and compared with the another algorithm developed on the basis of the ANSI N13.11 continuous spectrum X-ray fields. Then it follows the discussions for some results of the algorithm testing including mixed fields irradiations and angular response conducted in IAEA/RCA intercomparison as well as ANSI and ISO continuous spectrum X-ray and monochromatic radiation fields. The developed algorithms were successfully performed the test not only in the continuous spectrum X-ray fields given by MOST Ordinance but also in the several non-MOST Ordinance radiation fields which could be encountered in the practical working environments.

  • PDF

Trial Burns of Low-Level Radioactive Wastes the Demonstration-Scale Incineration Plant at KAERI (한국원자력 연구소 실증소각시설에서의 저준위방사성폐기물 시험소각)

  • Yang, Hee-Chul;Kim, In-Tae;Kim, Jeong-Guk;Kim, Joon-Hyung;Seo, Yong-Chil
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.767-774
    • /
    • 1995
  • Behavior of radionuclides such $^{60}$ Co, $^{54}$ Mn and $^{137}$ Cs in the incineration Process was Studied by trial burns of simulated wastes with radio-isotope tracers. Behavior of nonvolatiles, $^{60}$ Co and $^{54}$ Mn, was similar to that of particulate matters in the process. Decontamination factors(DFs) for $^{60}$ Co and $^{54}$ Mn were 4.7$\times$10$^{5}$ and 6.2$\times$10$^{5}$ , respectively. Behavior of semivolatile radio-isotope, $^{137}$ Cs, was temperature dependent. DFs for $^{l37}$Cs at In different incineration temperature of 85$0^{\circ}C$ and $700^{\circ}C$ were 2.8$\times$10$^3$ and 2.6$\times$10$^4$, respectively. Trial bums of dry active waste(DAW) transported from nuclear power station(NPS) Kori 3,4 were also performed. DF for gross $\beta$/${\gamma}$ radioactivity in DAW was 1.1$\times$10$^{5}$ . This was a little higher than the estimated value, which was calculated from the tracer test results and nuclides distribution in the DAW. Average emission concentration was 0.019 Bq/N $m^3$, which could meet the maximal permissible concentration(MPC) in stack emission.n.

  • PDF

FIRST ATLAS DOMESTIC STANDARD PROBLEM (DSP-01) FOR THE CODE ASSESSMENT

  • Kim, Yeon-Sik;Choi, Ki-Yong;Kang, Kyoung-Ho;Park, Hyun-Sik;Cho, Seok;Baek, Won-Pil;Kim, Kyung-Doo;Sim, Suk-K.;Lee, Eo-Hwak;Kim, Se-Yun;Kim, Joo-Sung;Choi, Tong-Soo;Kim, Cheol-Woo;Lee, Suk-Ho;Lee, Sang-Il;Lee, Keo-Hyoung
    • Nuclear Engineering and Technology
    • /
    • v.43 no.1
    • /
    • pp.25-44
    • /
    • 2011
  • KAERI has been operating an integral effect test facility, ATLAS (Advanced Thermal-Hydraulic Test Loop for Accident Simulation), for accident simulations of advanced PWRs. Regarding integral effect tests, a database for major design basis accidents has been accumulated and a Domestic Standard Problem (DSP) exercise using the ATLAS has been proposed and successfully performed. The ATLAS DSP aims at the effective utilization of an integral effect database obtained from the ATLAS, the establishment of a cooperative framework in the domestic nuclear industry, better understanding of thermal hydraulic phenomena, and an investigation of the potential limitations of the existing best-estimate safety analysis codes. For the first ATLAS DSP exercise (DSP-01), integral effect test data for a 100% DVI line break accident of the APR1400 was selected by considering its technical importance and by incorporating comments from participants. Twelve domestic organizations joined in this DSP-01 exercise. Finally, ten of these organizations submitted their calculation results. This ATLAS DSP-01 exercise progressed as an open calculation; the integral effect test data was delivered to the participants prior to the code calculations. The MARS-KS was favored by most participants but the RELAP5/MOD3.3 code was also used by a few participants. This paper presents all the information of the DSP-01 exercise as well as the comparison results between the calculations and the test data. Lessons learned from the first DSP-01 are presented and recommendations for code users as well as for developers are suggested.

The evaluation on the biological safety of diagnostic ultrasound using radiation-induced apoptosis in the external granular layer of mouse cerebellum (마우스 소뇌과립층의 apoptosis를 지표로 한 진단용 초음파의 안전성 검증)

  • Oh, Heon;Lee, Song-eun;Yang, Jung-ah;Jo, Sung-kee;Chung, Chi-young;Son, Chang-ho;Kim, Sung-ho
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.3
    • /
    • pp.628-634
    • /
    • 1999
  • We have studied, by a nonisotopic in situ end-labeling(ISEL) technique, frequency of apoptosis in the external granular layer(EGL) of the cerebellum of immature mice by ${\gamma}$-rays irradiation from $^{60}Co$ or diagnostic ultrasound exposure. The total number of normal cells and cells showing morphological features of apoptosis were counted. The frequency of apoptotic cells was expressed as a percentage of the total number of cells in EGL. The extent of changes following 200 cGy(1090 cGy/min) was studied at 2, 4, 6, 8, 12, or 24 hours after exposure. The maximal frequency was found 6~8 hours after exposure. The immature mice that received 18, 36, 54, 108, 198, 396 cGy of ${\gamma}$-rays or diagnostic ultrasound(7.5MHz, 4.2mW, $I_{SPTA}=7.9mW/cm^2$, $I_{SPTA}=114.3W/cm^2$) for 10 or 30 minutes were examined 6 hours after irradiation. Measurements performed after ${\gamma}$-ray irradiation showed a dose-related increase in apoptotic cells in each of the mice studied. The dose-response curves were analyzed by a linear-quadratic model ; frequency of apoptotic cell in the EGL was y = $(0.1349{\pm}0.01175)D$+$(-0.0001522{\pm}0.0000334)D^2$+0.048($r^2$ = 0.981, D = dose in cGy). In the experiment of ultrasound exposure, the frequency of apoptotic cell was $0.106{\pm}0.130$(10 minutes exposure) and $0.167{\pm}0.220$(30 minutes exposure). We estimated the relative dose of the yield from the experiment with ultrasound by substituting the yield from ultrasound exposure into the curve from the ${\gamma}$-irradiation. The relative dose of ultrasound exposure compared with ${\gamma}$-irradiation were 0.432 cGy(10 minutes exposure) and 0.885 cGy(30 minutes exposure). We have found that there is no evidence to indicate that diagnostic ultrasound involves a significant risk.

  • PDF

The effect of Bu-Zhong-Yi-Qi-Tang on ultraviolet B-induced skin damages in mouse (자외선 B 조사 마우스에서 피부손상에 대한 보중익기탕의 효과)

  • Kim, Joong-Sun;Lee, Hae-June;Song, Myoung-Sub;Seo, Heung-Sik;Moon, Changjong;Kim, Jong-Choon;Bae, Chun-Sik;Jo, Sung-Kee;Kim, Sung-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.49 no.1
    • /
    • pp.17-22
    • /
    • 2009
  • The effect of Bu-Zhong-Yi-Qi-Tang (BZYQT) on the changes of ultraviolet (UV) light B radiation-induced apoptotic sunburn cell (SBC) and epidermal ATPase-positive dendritic cell (DC) in SKH1- hr or ICR mouse were investigated. The mice were treated with UVB (200 mJ/$cm^2$) and were sacrificed 24 h later. BZYQT (50 mg/kg of body weight) or vehicle (saline) was given i.p. at 36 and 12 h before irradiation, and 30 min after irradiation or BZYQT cream (0.2%) or cream base (vehicle) was topically treated at 24 h and 15 min before irradiation, and immediately after irradiation. The skin of SKH1-hr mouse prepared from the back of untreated mice exhibited about 0.3 SBC/cm length of epidermis, and 24 h after UV irradiation, the applied areas show an increased number of SBCs. But the frequency of UVB-induced SBC formation was reduced by intraperitoneal injection of BZYQT extract (p < 0.01). The numbers of DC in normal ICR mouse were 628.00 ${\pm}$ 51.56 or 663.20 ${\pm}$ 62.58 per $mm^2$ of ear epidermis. By 1 day after UVB treatment, the number of ATPase-positive cells/$mm^2$ were decreased by 39.0% or 27.1% in i.p. or topical application group with vehicle. Treatment of BZYQT was associated with increase of 33.9% in i.p. group (p < 0.05) or 2.7% in topical application group in the number of ATPase positive cells compared with the irradiation control group. The results presented herein that BZYQT administration could reduce the extent of skin damages produced by UVB.

Effect of Wear Environments on the High Stress Sliding Wear Behavior of Ni-base Deloro 50 Alloy (Ni계 Deloro 50합금의 고하중 Sliding 마모거동에 미치는 마모환경의 영향)

  • Choi, Jin-Ho;Choi, Se-Jong;Kim, Jun-Gi;Kim, Yong-Deog;Kim, Hak-Soo;Mun, Ju-Hyun;Baek, Ha-Chung;Lee, Duck-Hyun;Kim, Seon-Jin
    • Korean Journal of Materials Research
    • /
    • v.8 no.12
    • /
    • pp.1115-1120
    • /
    • 1998
  • The sliding wear behavior of Ni-base hardfacing alloy, Deloro 50, was investigated at the contact stresses of 15ksi and 30ksi under the various wear environments. In air at room temperature, Deloro 50 showed lower wear resistance than Stellite 6 even at 15ksi due to the occurrence of severe adhesive wear. This seems to be caused by the lower hardness and work- hardening rate of Deloro 50 than those of Stellite 6. In water at room temperature, Deloro 50 showed as good wear resistance as Stellite 6 at 15ksi. It was considered to be due to that water could effectively prevent metal to metal contact through contacting asperities. However, Deloro 50 showed severe adhesive wear at 30ksi in water at room temperature. It seems to be that the water could not suppress adhesion wear at 30ksi. At $300^{\circ}C$ in air, Deloro 50 exhibited higher wear resistance than Stellite 6 even at 30ksi. It was considered that the oxide glaze layers formed on wear surface during sliding, effectively prevented direct metal-to-metal contacts.

  • PDF

Dosimetric Properties of LiF:Mg,Cu,Na,Si TL pellets (LiF:Mg,Cu,Na,Si TL 소자의 선량계적 특성)

  • Nam, Young-Mi;Kim, Jang-Lyul;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.7-12
    • /
    • 2001
  • Sintered LiF:Mg,Cu,Na,Si thermoluminescence (TL) pellets were developed for application in radiation dosimetry. In the present study, the TL dosimetric properties of LiF:Mg,Cu,Na,Si TL pellets have been investigated for emission spectrum, dose response, energy response, and fading characteristics. LiF:Mg,Cu,Na,Si TL pellets were made by using a sintering process, that is, pressing and heat treatment from TL powders. Photon irradiations for the experiments were carried out using X-ray beams and a $^{137}Cs$ gamma source at the Korea Atomic Energy Research Institute (KAERI). The average energies and the dose were in the range of 20-662 keV and $10^{-6}-10^{-2}\;Gy$, respectively. The glow curves were measured with a manual type TLD reader(System 310, Teledyne) at a constant nitrogen flux and a linear heating rate. For a constant heating rate of $5^{\circ}C\;s^{-1}$, the main dosimetric peak of glow curve appeared at $234^{\circ}C$, the activation energy was 2.34 eV and frequency factor was $1.00{\times}10^{23}$. TL emission spectrum is appeared at the blue region centered at 410 nm. A linearity of photon dose response was maintained up to 100 Gy. The photon energy responses relative to $^{137}Cs$ response were within ${\pm}20%$ at overall photon energy region. The fading of TL sensitivity of the pellets stored at the room temperature was not found for one year.

  • PDF