• Title/Summary/Keyword: K5 system

Search Result 31,957, Processing Time 0.057 seconds

Development of a Temperature Controller for Microwave-assisted Digestion System for Agricultural Samples (농식품 시료 전처리를 위한 마이크로웨이브 분해기용 온도 제어장치 개발)

  • Mo, Chang-Yeon;Kim, Gi-Young;Kim, Hak-Jin;Kim, Yong-Hun;Yang, Kil-Mo;Lee, Kang-Jin
    • Journal of Biosystems Engineering
    • /
    • v.34 no.5
    • /
    • pp.371-376
    • /
    • 2009
  • Microwave digestion is a preferred pretreatment method for agricultural samples because of its quick chemical reaction and minimum loss of analytes. In this research, a feedback temperature controller was developed to control the temperature inside a vessel for the microwave-assisted digestion system. An existing industrial microwave oven was fitted with the temperature controller for controlling inside temperature of the vessel. Four control methods, On/Off, proportional (P), proportional integral (PI), and proportional integral derivative (PID) were used and compared. Experimental results showed that PID control produced best temperature control performance. The PID controller could maintain the temperature of water sample and rice sample in the digestion system with error range of $-2.5{\sim}3.3^{\circ}C$ and $-1.9{\sim}0.5^{\circ}C$ at set temperature of $170^{\circ}C$, respectively.

Performance Simulation of a R744-R717 Cascade Refrigeration System According to Operating Conditions (R744-R717 캐스케이드 냉동시스템에서 운전조건 변화에 따른 성능 해석)

  • Ryu, Jiho;Cho, Honghyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.497-505
    • /
    • 2015
  • The evaporating temperature range required for the low temperature freezing system is from $-50^{\circ}C$ to $-30^{\circ}C$. Since it is difficult to keep the required capacity in a cabinet, it is advantageous to design the system using a cascade refrigeration system. Use of carbon dioxide and ammonia would be advantageous since ammonia is an environment-friendly working fluid and has a high capacity for performance improvement. To investigate the performance characteristics of the R744-R717 cascade refrigeration system, a theoretical model was developed and performance was analyzed according to cascade heat exchanger operating temperature. The optimal cascade R744 condensing temperature was $-5^{\circ}C$, and maximum COP was 1.13 when the temperature difference of the cascade heat exchanger was $5^{\circ}C$. In addition, the total system COP increased by 1.17 when the cascade temperature gap was $3^{\circ}C$ at the middle temperature of $-7.5^{\circ}C$.

LED Board Optimization Design for User-Friendly System Configuration (사용자 친화적 시스템 구성을 위한 LED 보드 최적화 설계)

  • Ju-An Park;Chang-Woo Han;Hui-Sang Yoo;Boong-Joo Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.5
    • /
    • pp.859-866
    • /
    • 2023
  • This paper focuses on configuring a user-friendly system of LED systems by applying improvement measures such as gamma correction, non-flicker, and driving noise removal using MCUs and LED drivers. As a result of the experiment, the 22kHz PWM mode of the LED driver generated noise outside the audible frequency range, making it practically imperceptible to users. The appropriate pull-up resistor values within the normal operating delay ratio of 5% were found to be 1kΩ to 10kΩ for the 3kHz PWM mode and 1kΩ to 2kΩ for the 22kHz PWM mode. In addition, gamma correction can be optimized for nonlinear human visual systems to express accurate contrast and as a result, it is expected to develop an LED system that can be expressed more naturally and accurately than conventional LED systems and improve users' visual experience.

Study of the Respiratory Monitoring System by Using the MEMS Acceleration Sensor (MEMS 가속도 센서를 이용한 환자 호흡동작 모니터링 체계 연구)

  • Sung, Jiwon;Yoon, Myonggeun;Chung, Weon Kuu;Kim, Dong Wook;Shin, Dong Oh
    • Progress in Medical Physics
    • /
    • v.24 no.1
    • /
    • pp.61-67
    • /
    • 2013
  • In this study, we developed and evaluated the patient respiration training method which can help to avoid the problems for the limitation of RGRT applicable patient cases. By using the MEMS (micro-electro-mechanical-system) acceleration sensor, we measured movement of motion phantom. We had compared the response of MEMS with commercially introduced real time patient monitoring (RPM) system. We measured the response of the MEMS with 1 dimensional motion phantom movement for 2.5, 3.0, 3.5 second of period and the 2.0, 3.0, 4.0 cm of the amplitudes. The measured period error of the MEMS system was 0.6~6.0% compared with measured period using RPM system. We found that the shape of MEMS signals were similar with RPM system. From this study, we found the possibility of MEMS as patient training system.

Development of Auto-Parking Algorithm for Driving in Urban (무인차량의 자동주차 알고리즘 개발)

  • Cho, Kyoung-Hwan;Chung, Jin-Wok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.5
    • /
    • pp.2360-2366
    • /
    • 2011
  • The Unmanned Ground Vehicle is comprised of four systems of obstacle detection: The navigation system, vehicle controlling system, obstacle detecting and an integration system that use the various sensors. The research introduced utilizes 6 lasers to recognize obstacles. The system operates an avoidance system within the unmanned ground vehicle, using six lasers. The Unmanned Ground Vehicle's parallel parking and right angle parking is in development using algorithms. This algorithms' certification is intended to be installed in the encoder, in the GPS. By using the Laser Scannerfor the position's calculation, errors are both reduced and minimized, so the tire's slip minimized to the point where the vehicle had a limit of about 5Km/h.

Triffin Dilemma and International Monetary System : Evidence from Pooled Mean Group Estimation

  • Guan, Long-Fei;Lau, Wee-Yeap
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.5 no.2
    • /
    • pp.5-14
    • /
    • 2018
  • This study is motivated based on concern from some renowned scholars and central bankers whom have raised the issue of the sustainability of the International Monetary System (IMS). Using the panel data set of four major international currencies, USD, JPY, EUR and GBP from 1973 to 2013 with Pooled Mean Group (PMG) estimator, to re-examine whether Triffin dilemma still exists through investigating the relationship between the reserve share, current account balance and real effective exchange rate. The evidence from the result indicates that Triffin dilemma exists only in the long run, and shows that in the long-run, current account balance is proportionate to the increased real effective exchange rate while varies inversely with the reserve shares. However, the estimation for the short-run is not significant to prove the existence of Triffin dilemma. In addition, we investigated the non-dollar panel sample and found that the international monetary system still suffers from Triffin dilemma even without the dollar. To overcome Triffin dilemma, immediate step such as having currency swap mechanism is recommended. In medium term, a multi-polar Monetary System is suggested, and in the longer time, a supranational currency will be used to replace all the currencies in the world.

Application Study of small-scale sewage treatment system with A2/O precess in Mongolia (A2/O 공법을 이용한 소규모 하수처리시스템의 몽골 현지 적용에 관한 연구)

  • Yeo, Yeongki;Kim, Younghee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.5
    • /
    • pp.431-440
    • /
    • 2017
  • The small-scale sewage treatement system with $A^2/O$ process was applied to evaluate applicability for Mongolian sewage, It was designed to have 10 m3/d flowrate and installed in Ulaanbaatar, Mongolia. During over 6month operation BOD, COD, TN, TP removal efficiency were measured and operation condition was optimized. In addition, MLSS concentration its internal circulation rate and DO were adjusted properly. BOD, COD showed average 88 perecent of removal and TN and TP achieved 81 percent and 88 percent removal efficency, respectively. Maxium influent concentration of BOD, COD, TN and TP was 214 mg/L, 300 mg/L, 24.3 mg/L and 5 mg/L respectively, which were decreased to 4.1 mg/L, 5.6 mg/L, 1.3 mg/L and 0.15 mg/L by the test system. This study show possibility tham small-scale sewage treatment system could be a useful system for scattered sewage wastewater treatment.

MMB System and Channel Model for 5th Generation Mobile Communication (5세대 이동통신을 위한 MMB 시스템 및 채널 모델)

  • Moon, Sangmi;Kim, Bora;Malik, Saransh;Kim, Jihyung;Lee, Moon-Sik;Kim, Daejin;Hwang, Intae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.8
    • /
    • pp.3-10
    • /
    • 2014
  • Millimeter wave (mmWave) has attracted great interest recently and the necessity of Millimeter Mobile Broadband (MMB) system has appeared based on the 4 Generation Long Term Evolution-Advanced (LTE-A) Specification. Currently, there are many studies about the mmWave communication channel. And it is subject of interest to analyze the performance in MMB channel environments. In this paper, we design the MMB system for 5th Generation mobile communication and propose channel models through the analysis of the mmWave propagation characteristics. Also, we have analyzed the performance of the MMB system of 28 GHz band in MMB channel environments.

Technical Trends of 5th Generation Wireless Backhaul (5세대 무선 백홀 기술 동향)

  • Moon, Y.J.;Lee, Y.S.;Bang, S.J.;Kim, J.W.;Moon, J.W.;Sohn, K.Y.;Lee, H.
    • Electronics and Telecommunications Trends
    • /
    • v.33 no.5
    • /
    • pp.24-32
    • /
    • 2018
  • With the advent of new convergence services, the requirements of 5G mobile communication systems are being newly derived. The 5G mobile communication system has been evolving to solve requirements that cannot be satisfied with existing 4G mobile communication systems, such as a high user experience transmission rate, short transmission delay, and high connection density. The evolution of a 5G mobile communication system to meet the new requirements is expected to be dominated by the UDN environment in which a number of small cells are concentrated. The 5G wireless backhaul system, which has advantages in terms of initial installation and operation cost, is expected to be an indispensable choice for connecting many small cells and core networks. This paper therefore looks at the frequency band characteristics and requirements applicable to 5G wireless backhaul systems that can accommodate new situations, and introduces key related technologies that can satisfy the 5G wireless backhaul requirements.. In addition, we describe the research and development trends of a 5G wireless backhaul system that is currently under development.

Development of a Portable Total-phosphorus Monitoring System for Preventing Eutrophication in Advance (부영양화 사전 예방을 위한 휴대용 총인 모니터링 시스템 개발)

  • Jung, Dong Geon;Kim, Seung Deok;Kwon, Soon Yeol;Lee, Jae Yong;Kim, Yu Seong;Lee, Junyeop;Kim, JaeKeon;Kim, Sae-Wan;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.342-347
    • /
    • 2020
  • In this study, a portable total-phosphorus (TP) monitoring system utilizing a photocatalytic-reaction-based pretreatment method is proposed, fabricated, and characterized. Commercial TP monitoring systems are only used in laboratories because of their complex monitoring procedure, bulk-size, and high-cost. In particular, pretreatment in commercial TP monitoring systems is performed at high temperatures (> 120 ℃) and pressure (> 1.1 kg cm-2) making it difficult to minimize the scale of the systems. The proposed TP monitoring system employs a pretreatment method with a photocatalytic reaction; thus, its size can be reduced, as photocatalytic reactions occur at room temperature and atmospheric pressure. Analytes with various TP concentrations are pretreated using the proposed portable TP monitoring system and are quantitatively measured with an LED and a photodiode.