• Title/Summary/Keyword: K5 system

Search Result 31,957, Processing Time 0.068 seconds

Captive Flight Test System Configuration and Verification for Multi-mode Guidance Missile System (복합유도방식이 적용된 유도탄의 탑재비행시험(CFT) 시스템 구성 및 검증)

  • Park, Inchul;Heo, Wonyoung;Lee, Yongho;Jeong, Seyoung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.606-612
    • /
    • 2016
  • A Captive Flight Test(CFT) is used to verify the performance of missile component such as seeker and guiding algorithm of missile. Recently most of surface to air missile adapts multi-mode guidance method which include command guidance and active/passive guidance. A CFT system for missile system adapting multi-mode guidance method consists of pod equipment, command transmitting system and measuring system. In this paper, we proposed CFT system and testing method for missile which adapt multi-mode guidance, and system integration procedure by using distributed missile system integration method and procedure. The proposed CFT system and system integration method was applied to CFT of surface to air missile, and brought successful result.

Development of Unified SCADA System Based on IEC61850 in Wave-Offshore Wind Hybrid Power Generation System (파력-해상풍력 복합발전시스템의 IEC61850기반 통합 SCADA시스템 개발)

  • Lee, Jae-Kyu;Lee, Sang-Yub;Kim, Tae-Hyoung;Ham, Kyung-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.5
    • /
    • pp.811-818
    • /
    • 2016
  • This paper suggests a structure of power control system in floating wave-offshore wind hybrid power generation system. We have developed an unified SCADA(Supervisory Control and Data Acquisition) system which can be used to monitor and control PCS(Power Conversion System) based on IEC61850. The SCADA system is essential to perform the algorithm like proportional distribution and data acquisition, monitoring, active power, reactive power control in hybrid power generation system. IEC61850 is an international standard for electrical substation automation systems. It was made to compensate the limitations of the legacy industrial protocols such as Modbus. In order to test the proposed SCADA system and algorithm, we have developed the wind-wave simulator based Modbus. We have designed a protocol conversion device based on real-time Linux for the communication between Modbus and IEC61850. In this study, SCADA system consists of four 3MW class wind turbines and twenty-four 100kW class wave force generator.

The prospects and strategy for the implementation of the annual salary system in Korean hospitals (병원 연봉제에 관한 경영자 인식조사 및 도입기본전략)

  • Lee, Hye-Young;Seo, Young-Joon
    • Korea Journal of Hospital Management
    • /
    • v.5 no.1
    • /
    • pp.105-128
    • /
    • 2000
  • This study was conducted to investigate the prospects and issues for the implementation of the annual salary system in Korean hospitals. Data were collected from the top management of 669 hospitals in Korea through the self-administerd questionnaires. Of the 175 respondents, 171 questionnaires were used as final data and analyzed using $X^2$ test. The results of the study are as follows. 1) It is found that 49.7% of the study hospitals are operating the annual salary system. 2) Among the hospitals which are not operating the annual salary system, 49.2% have the plan to implement the system and 44.5% have not decided yet whether they introduce the system or not. 3) The proportion of the hospitals which have the plan to implement the annual salary system within 5 years is 96.8%. 4) The proportion of the hospitals which will begin the system only with full-time physicians and middle level managers is 36.2%, while that of the hopsitals which will apply the system to all employees is 30.5%. 5) Hospital Administrators seems to prefer to 10-20% salary gap for the introduction period among the employees with same salary. 6) Most of the respondents are willing to accept the payment system based on the performance. 7) The major issues which should be dealt with before the implementation of the annual salary system are the establishment of the objectivity of performance evaluation criteria, the improvement of teamwork, and the maintenance of organizational commitment. 8) The desirable criteria for employee evaluation are found to be the mixture of the ability, job position, tenure, and the job difficulty.

  • PDF

Optimal Design of Cogeneration System for General Facilities Considering LCC Analysis (LCC 분석을 고려한 일반 시설물에서 소형열병합발전의 최적 설계)

  • Kang, Yul-Ho;Ku, Bon-Cheol;Hwang, Yu-Jin;Song, Jae-Do;Cheong, Seong-Ir;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.8
    • /
    • pp.439-447
    • /
    • 2009
  • Cogeneration system produces power as well as heat recovered from waste heat during power generation process. This system has higher energy efficiency than that of the power plant. In this study the optimal design for the cogeneration system with the increase of the capacity considering life cycle cost(LCC) analysis has been performed in the general facilities such as hotels and hospitals under the assumption of electricity cost of 95 won/kWh, the initial cost of cogeneration system of 1,500,000 won!kW and the value of 0.5${\sim}$1.0 in the ratio of heat to power. The optimal ratio of cogeneration capacity divided by average electricity load of facility was found out more than 0.5 in case of electricity cost with the increase of>30%, and the percentage of $CO_2$ reduction was about 9%. The most important factors in the economic analysis of cogeneration system was found out the electrity cost and the initial cost of cogeneration system. Also the ratio of heat to power at the value of>0.5 was not affected in the economy of cogeneration system, but was very important in the $CO_2$ reduction.

A Study on System Optimization according to the Supply Obligations Rate of New and Renewable Energy at an Indoor Gymnasium (실내체육관의 신재생에너지 공급의무비율에 따른 시스템 최적화 연구)

  • Park, Yun-Ha;Kim, Yun-Ho;Won, An-Na;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.6
    • /
    • pp.51-60
    • /
    • 2015
  • In statutes on the promotion of distribution of new and renewable energy, which were revised in 2014, daylight system and fuel cell were added in addition to existing new and renewable energy sources. This study, therefore, aimed at setting up targets for the introduction of daylight system and analyzing the installation rate of new and renewable energy which can be provided by daylight system for the aggressive use of daylight system, thereby deducting the optimal combination ratio with other new and renewable energy sources. The results of the study are as follows. First, when a prism-shaped daylight system was installed to a round indoor gymnasium among domestic indoor gymnasiums, out of a supply obligations allotment rate of 15% of new and renewable energy, the rate of daylight system was basically set at 2.5%. Second, therefore, with daylight system coming first, the lacked supply obligations rate was taken up by solar photovoltaic, solar heat and geothermal heat. In addition, using the KRESS Program, economic, technical, environmental and complexity evaluations for the upper 5% was made, deducting the optimal ratio of the system. The results produced the following optimal combination ratios: solar photovoltaic (83.3%) in economic evaluation, solar heat (8.3%) and geothermal heat (75%) in technical evaluation, solar photovoltaic (83.3%) in environmental evaluation, and solar photovoltaic (83.3%, the same as in economic evaluation) in complexity evaluation.

Battery Charging System for PHEV and EV using Single Phase AC/DC PWM Buck Converter

  • Lee, Jung-Hyo;Jung, Doo-Yong;Park, Sang-Hoon;Lee, Taek-Kie;Kim, Young-Ryul;Won, Chung-Yuen
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.736-744
    • /
    • 2012
  • In this paper, a battery charging system for Plug-in Hybrid Electric Vehicle (PHEV) and Electric Vehicle (EV), and operation algorithm of charging system are introduced. Also, the proposed charging system uses commercial electricity in order to charge the battery of parked PHEV and 48V battery charging system with power factor controllable single phase converter for PHEV is investigated in this paper. This research verifies the power factor control of input and the converter output controlled by the charge control algorithm through simulation and experiment.

A Practical Power System Stabilizer Tuning Method and its Verification in Field Test

  • Shin, Jeong-Hoon;Nam, Su-Chul;Lee, Jae-Gul;Baek, Seung-Mook;Choy, Young-Do;Kim, Tae-Kyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.3
    • /
    • pp.400-406
    • /
    • 2010
  • This paper deals with parameter tuning of the Power System Stabilizer (PSS) for 612 MVA thermal power plants in the KEPCO system and its validation in a field test. In this paper, the selection of parameters, such as lead-lag time constants for phase compensation and system gain, is optimized using linear and eigenvalue analyses. This is then verified through the time-domain transient stability analysis. In the next step, the performance of PSS is finally verified by the generator's on-line field test. After the field test, measured and simulated data are also compared to prove the effectiveness of the models used in the simulations.

Fabrication of Composite Drug Delivery System Using Nano Composite Deposition System and in vivo Characterization

  • Chu, Won-Shik;Jeong, Suk-Yong;Pandey, Jitendra Kumar;Ahn, Sung-Hoon;Lee, Jae-Hoon;Chi, Sang-Cheol
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.81-83
    • /
    • 2008
  • The Rapid Prototyping (RP) technology has advanced in many application areas. In this research, two different types, cylinder and scaffold, of implantable Drug Delivery System (DDS) were fabricated using Nano Composite Deposition System (NCDS), one of the RP systems. The anti-cancer drug (5-fluorouracil, 5-FU), biodegradable polymer (PLGA(85: 15)), and bio ceramic (Hydroxyapatite, HA) were used to form drug-polymer composite material. Both types of DDS were evaluated in vivo environment for two weeks. For evaluation, the cumulative drug release and shape stability were measured. Test results showed that the scaffold DDS provide higher cumulative drug release and has better stability than cylinder DDS.

A Study on Effectiveness of Application of the IEC 61689 Standard to Ultrasonic Physiotherapy Systems with Frequency Range over 5MHz (5MHz 초과 초음파자극기에 대한 IEC 61689 규격 적용의 유효성에 관한 연구)

  • Youn, Ju-Shin;Choi, Gi Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.69-78
    • /
    • 2015
  • Ultrasonic physiotherapy systems should comply with IEC 60601-2-5(particular requirements for safety of ultrasonic physiotherapy equipment) standard for safety of patients and clinical performances. One of the most important parameters in the standard is the effective radiating area ($A_{ER}$). It has to be measured in accordance with IEC 61689 (field specifications and methods of measurement in the frequency range 0.5MHz to 5MHz). Typical ultrasonic physiotherapy system works in the frequency range 1MHz ~ 3MHz to comply with the IEC 61689. However, ultrasonic physiotherapy system using frequencies over 5MHz is out of the IEC 61689's scope. That is, even if such ultrasonic physiotherapy systems are developed by demands of the market, there is no standard to apply. It is the motivation for this study. Whereas there are other parameters to be considered, this study focuses on the effective radiating area and shows effectiveness of applying IEC 61689 in measuring effective radiating area of ultrasonic physiotherapy systems using frequency range over 5MHz by comparing the results of computer simulation and experiment. Results of this study shows that applying the IEC 61689 standard to ultrasonic physiotherapy system using frequency range over 5MHz is possible.

Pharmacist Education and National License Examination System in North Korea (북한의 약사교육 시스템과 시험제도(국가면허) 연구)

  • Lee, Hye Kyoung
    • Korean Journal of Clinical Pharmacy
    • /
    • v.25 no.4
    • /
    • pp.216-222
    • /
    • 2015
  • Unity, understanding our pharmacist pharmacy education and training and their ecosystems rather then overwrite the system will get you ready to integrate and balance searching for contacts. Since 2015 we started the 6-year pharmacy education in the North were already carried out (the current 5.5 years). This chemist (or pharmacist) educate university education and vocational school and health officials made in the training school in jimyeo. Duration of each is to the University of 5.5 years, college three years, health officer training school two years and various types of training methods (weekly, communication, special) is applied is positive. License test system is also in favor of the state graduation test graduation test committee of professors in the university college diploma than the national notification system, and pharmacists 'qualifications' - are licensed is granted. The North Korean education system pharmacists and pharmacist review and analysis test system for the future reunification of Korea oriented education system pharmacists and pharmacists in health care personnel office systems through correct understanding and awareness-will be a useful resource integration plan designed to pharmacists.