• Title/Summary/Keyword: K-point

Search Result 28,021, Processing Time 0.048 seconds

Stay Point Extraction Method that Improve Accuracy of Location and to Distinguish Between Indoors & Outdoors (실내·외 구분 및 위치의 정확성을 개선한 Stay Point 추출 기법)

  • Park, Jin-Gwan;Lee, Seong-Ro;Jung, Min-A
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.6
    • /
    • pp.95-104
    • /
    • 2015
  • Recently, collecting and analyzing method of users location has been studied due to the development of mobile devices. There is analyzing method using Semantic Location History in order to identify of characteristics and extract pattern and predict trajectory of users. We should extraction of Stay Point in order to use Semantic Location History. The Conventional extraction method of Stay Point is not accuracy of location of Stay Points because it does not specify the GPS log of users. Also, Conventional extraction method of Stay Point cannot distinguish indoors and outdoors. In this paper, we implement extraction method of Stay Point in which specify the GPS log of users and extraction of Stay Point at indoors only. Stay Point(nearSP) specifies the nearest GPS log of users from generated Stay Point by conventional extraction method. And, Stay Point(indoorSP) specifies the GPS log of users that user get into the building. Our experimental results, accuracy of Stay Point is improved, and capacity of output data decrease than Conventional extraction method. Also, we were able to distinguish Stay Point of indoors and outdoors.

Design of Improved Switch Point Heating System for Low Power and Simplified Equipment (저전력 및 설비간략화를 위한 선로전환기용 융설장치 설계)

  • Jang, Dongwan;Jeon, Taehyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.61-67
    • /
    • 2013
  • The turnout point system is installed to separate the main rail track from other tracks in rail load stations. It is also important to set up the switch point system to change the direction of the turnout point, to lead and change the direction of tracks. The switch point system can be negatively affected by heavy snow during winter seasons which can cause critical safety problems. Furthermore, the maintenance and repair of the conventional system is prohibitively expensive due to its complexity and high probability of failure. In this paper, an efficient switch point system is proposed which simplifies the equipment structure and lowers the cost for maintenance and repair, while improving safety and performance of the rail road system.

Flash Point Calculation for n-Octane+n-Decane and n-Octane+n-Dodecane by UNIFAC Group Contribution Model (UNIFAC 그룹 기여 모델에 의한 n-Octnae+n-Decane 계와 n-Octane+n-Dodecane 계의 인화점 계산)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.4
    • /
    • pp.86-91
    • /
    • 2015
  • The flash point is used to categorize inflammable liquids according to their relative flammability. Such a categorization is important for the safe handling, storage, and transportation of inflammable liquids. The flash point temperature of two binary liquid mixtures(n-octane+n-decane and n-octane+n-dodecane) has been measured for the entire concentration range using Seta-flash closed cup tester based on the ASTM D3278 method. The closed cup flash point temperature was estimated using the UNIFAC(Universal Functional Activity Coefficient) group contribution model. The experimentally derived flash point was also compared with the predicted flash point from the UNIFAC model. The UNIFAC model is able to estimate the flash point fairly well for n-octane+n-decane mixture and n-octane+n-dodecane mixture.

Extraction of Geometric Primitives from Point Cloud Data

  • Kim, Sung-Il;Ahn, Sung-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2010-2014
    • /
    • 2005
  • Object detection and parameter estimation in point cloud data is a relevant subject to robotics, reverse engineering, computer vision, and sport mechanics. In this paper a software is presented for fully-automatic object detection and parameter estimation in unordered, incomplete and error-contaminated point cloud with a large number of data points. The software consists of three algorithmic modules each for object identification, point segmentation, and model fitting. The newly developed algorithms for orthogonal distance fitting (ODF) play a fundamental role in each of the three modules. The ODF algorithms estimate the model parameters by minimizing the square sum of the shortest distances between the model feature and the measurement points. Curvature analysis of the local quadric surfaces fitted to small patches of point cloud provides the necessary seed information for automatic model selection, point segmentation, and model fitting. The performance of the software on a variety of point cloud data will be demonstrated live.

  • PDF

Change-point Approach for Analyzing Failure Trend in Repairable Generating Systems (수리 가능 발전기 시스템의 고장추세 분석을 위한 변화점 접근방법)

  • Hong, Min-Pyo;Bae, Suk-Joo
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.1
    • /
    • pp.11-19
    • /
    • 2009
  • A number of trend test methods, i.e., Military Handbook test and Laplace test etc., have been applied to investigate recurrent failures trend in repairable systems. Existing methods provide information about only existence of trend in the system. In this paper, we propose a new change-point test based on the Schwarz Information Criterion(SIC). The change-point approach is more informative than other trend test methods in that it provides the number of change-points and the location of change-points if it exists, as well as the existence of change-point for recurrent failures. The change-point test is applied to nine 300MW generating units operated in East China. We confirm that the change-point test has a potential for establishing optimal preventive maintenance policy by detecting change-point of failure rate.

Change-Point in the Recent (1976-2005) Precipitation over South Korea (우리나라에서 최근 (1976-2005) 강수의 변화 시점)

  • Kim, Chansoo;Suh, Myoung-Seok
    • Atmosphere
    • /
    • v.18 no.2
    • /
    • pp.111-120
    • /
    • 2008
  • This study presents a change-point in the 30 years (1976-2005) time series of the annual and the heavy precipitation characteristics (amount, days and intensity) averaged over South Korea using Bayesian approach. The criterion for the heavy precipitation used in this study is 80 mm/day. Using non-informative priors, the exact Bayes estimators of parameters and unknown change-point are obtained. Also, the posterior probability and 90% highest posterior density credible intervals for the mean differences between before and after the change-point are examined. The results show that a single change-point in the precipitation intensity and the heavy precipitation characteristics has occurred around 1996. As the results, the precipitation intensity and heavy precipitation characteristics have clearly increased after the change-point. However, the annual precipitation amount and days show a statistically insignificant single change-point model. These results are consistent with earlier works based on a simple linear regression model.

An Open-Loop Method for Point-to-Point Positioning of a Piezoelectric Actuator

  • Henmi, Nobuhiko;Tanaka, Michihiko
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.9-13
    • /
    • 2007
  • We describe how to control a piezoelectric actuator using the open-loop method for point-to-point positioning. Since piezoelectric actuators have nonlinear characteristics due to hysteresis and creep between the input voltage and the resulting displacement, a special method is required to eliminate this nonlinearity for an open-loop drive. We have introduced open-loop driving methods for piezoelectric actuators in the past, which required a large input voltage and an initializing motion sequence to reset the state of the actuator before each movement. In this paper, we propose a new driving method that uses the initializing state. This method also utilizes the overshoot from both the upward and downward stepwise drives. Applying this method., we obtained precise point-to-point positioning without the influence of hysteresis and creep.

A Novel Virtual Space Vector Modulation Strategy for the Neutral-Point Potential Comprehensive Balance of Neutral-Point-Clamped Converters

  • Zhang, Chuan-Jin;Tang, Yi;Han, Dong;Zhang, Hui;Zhang, Xiao;Wang, Ke
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.946-959
    • /
    • 2016
  • A novel Virtual Space Vector (VSV) modulation strategy for complete control of potential neutral point (NP) issues is proposed in this paper. The neutral point potential balancing problems of multi-level converters, which include elimination of low frequency oscillations and self-balancing for NP dc unbalance, are investigated first. Then a set of improved virtual space vectors with dynamic adjustment factors are introduced and a multi-objective optimization algorithm which aims to optimize these adjustment factors is presented in this paper. The improved virtual space vectors and the multi-objective optimization algorithm constitute the novel Virtual Space Vector modulation. The proposed novel Virtual Space Vector modulation can simultaneously recover NP dc unbalance and eliminate low frequency oscillations of the neutral point. Experiment results show that the proposed strategy has excellent performance, and that both of the neutral point potential issues can be solved.

An Analytical Study on the Optimal Set-point of the Hybrid Plant (복합열원설비 운전온도 최적 설정에 관한 해석적 연구)

  • Jeon, Jong-Ug;Lee, Sun-Il;Lee, Tae-Won;Kim, Yong-Ki;Hong, Dae-Hie;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.352-357
    • /
    • 2007
  • The objective of this study is to find the optimal set-point of a hybrid Plant, which is combined by renewable energy plant of the GSHP(Ground Source Heat Pump) and the conventional plant(chiller, boiler). The work presented in this study was carried out by using the EnergyPlus(Version 2.0). In order to validate the simulation model, field data were measured from a building. The GSHP was used as a base plant and the conventional plant as the assistant plant. Various temperatures were controlled (zone summer set-point, zone winter set-point, chilled water temperature, hot water temperature) to find the optimal set-point temperature of the system. The influence of the various set-points were analyzed seasonally.

  • PDF

A Study on the Acupuncture Point Resistance Characteristics(II) (경혈 저항특성에 관한 연구(II))

  • Kim, E.S.;Han, S.C.;Choi, T.J.;Kim, J.K.;Hur, Woong;Park, Y.B.
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.69-72
    • /
    • 2001
  • In this paper, we study about a acupuncture point and a non-acupuncture point resistance characteristics for acupuncture research. For this study, we devised resistance variation measurement system. This system is consist of 4-channel skin resistance measuring parts, filters, 12bit A/D convertor, 8051 micro-controller, and personal computer The developed system insert a low current to skin and obtains voltages from standard resistor that is convected to measurement circuit in series. The obtained voltage is converted to 12bit digital signal. Therefore the converted signal is changed to skin resistance by calculation in the personal computer. As the results of experiment, the resistance of acupuncture point and non-acupuncture point are different from each other. The acupuncture point has very fast current flows than the other non- acupuncture point.

  • PDF