• Title/Summary/Keyword: K-TAC

Search Result 223, Processing Time 0.023 seconds

A Study on Fisheries Management of Ecosystem-Based TAC using a Linear Programming (선형계획법을 이용한 생태계 기반 TAC 어업관리에 관한 연구)

  • Seo, Young-Il;Cheon, Seong-Hoon;Kim, Do-Hoon
    • The Journal of Fisheries Business Administration
    • /
    • v.45 no.2
    • /
    • pp.61-72
    • /
    • 2014
  • This study aimed to empirically investigate the applicability of ecosystem-based TAC (Total Allowable Catch) fisheries management targeting the large purse seine fishery where multi-species are regulated by TAC. Using a linear programming, the optimal fishing effort and the catch amount by species which maximize fishing profits were analyzed under the constraint condition of catch limits by species. Analytical results showed that an application of TAC on only chub mackerel would have negative impacts on fish stocks such as hairtail and jack mackerel by increasing the level of fishing effort to achieve its allocated catch limit. However, under the constraint condition of catch limits of all species, it was shown that optimal catches of all species were achieved within their catch limits. It implies the importance of ecosystem-based management considering biological and technical interactions of species those were excluded in the traditional single species fisheries management.

Effect of Poly(vinyl alcohol) Adhesives on the Dimensional Stability of LCD Polarizer (폴리(비닐 알코올) 접착제가 LCD 편광판의 치수안정성에 미치는 영향)

  • Suh, Ju-Hee;Shin, Jung-Woo;Kim, Hyo-Kap;Kim, Han-Sung;Kim, Yong-Won;Kang, Ho-Jong
    • Polymer(Korea)
    • /
    • v.34 no.6
    • /
    • pp.560-564
    • /
    • 2010
  • Dimensional stability of LCD polarization film consisted of triacetyl cellulose (TAC) and poly(vinyl alcohol) (PVA) film has been studied and especially, the effect of PVA adhesive on the dimensional stability has been considered as function of deacetylation and molecular weight of PVA adhesive. The maximum adhesion strength between TAC and PVA film was obtained in the laminate using PVA adhesive with 70% of OH content and the effect of molecular weight on the adhesion strength was only pronounced in the laminate using PVA adhesive with OH content above 70%. It was found that the optimum dimensional stability of TAC/PVA/TAC laminate (polarizing film) was obtained when applied PVA adhesive has low molecular weight and it was more dependent upon the OH content than the adhesion strength between TAC and PVA films.

Validation of Analytical Methods for Plasma Total Antioxidant Capacity by Comparing with Urinary 8-Isoprostane Level

  • Lee, Sang Gil;Wang, Taoran;Vance, Terrence M.;Hurbert, Patrice;Kim, Dae-Ok;Koo, Sung I.;Chun, Ock K.
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.2
    • /
    • pp.388-394
    • /
    • 2017
  • Although several analytical methods for measuring total antioxidant capacity (TAC) have been applied to biological samples, there were often dissimilar results due to the different principles of methods applied. Thus, this study aimed to validate four conventional analytical methods for measuring plasma TAC, including the ABTS assay, DPPH assay, FRAP assay, and ORAC assay, by comparing with urinary 8-isoprostane concentration. In addition, TAC results were compared with antioxidant enzyme activities including superoxide dismutase (SOD) and glutathione peroxidase in erythrocyte, and catalase in plasma. Plasma TAC measure by ABTS assay was strongly correlated with the result by FRAP assay. Plasma TAC by FRAP and ORAC assays were negatively correlated with erythrocyte SOD activity. The agreement among the four TAC assay methods and 8-isoprostane was determined using 95% prediction limits of linear regression, expressed as the mean of 8-isoprostane ${\pm}95%$ prediction limits. The ABTS method better agreed with 8-isoprostane than the other methods, demonstrating narrow prediction of limits. Furthermore, only plasma TAC determined by the ABTS assay was inversely correlated with urinary 8-isoprostane (r = -0.35, p < 0.05). In summary, the ABTS assay would be an appropriate method to measure overall plasma antioxidant capacity and predict the body's antioxidant status.

The Percentage of Consonants Correct and the Ages of Consonantal Aquisition for 'Korean-Test of Articulation for Children(K-TAC)' (`아동용 조음검사`를 이용한 연령별 자음정확도와 우리말 자음의 습득연령)

  • Kim, Min-Jung;Pae, So-Yeong
    • Speech Sciences
    • /
    • v.12 no.2
    • /
    • pp.139-149
    • /
    • 2005
  • The purpose of this study was to propose a preliminary norm for 'Korean-Test of Articulation for Children(K-TAC)'. The K-TAC was designed to test 19 Korean consonants in various phonetic contexts through 37 words. We collected the data of 220 normally developing children aged 2;6(years;months) to 6;5. We analyzed the mean percentage of consonants correct and the age of acquisition for K-TAC. The results were as follows: first, The mean percentage was over 60% at late 2 years of age, over 80% at th age of 3, and over 90% after the age of 4. There were significant differences among age groups. Second, based on the criterion of correct production by 75% of children, Korean children acquired stops and nasals except for SF velars, glottal fricative, SF liquid and affricates by late 2 or 3 years of age. After that they acquired SF velars at the age of 4 and SI liquid at the age of 5. However, they could not acquire alveolar fricatives by the age of late 6. Third, if the distorted sounds were scored as correct, they acquired SI liquid at 4 years of age and alveolar fricatives at 5 years of age.

  • PDF

Cure Characteristics of Foaming EVA Compounds: Influence of EVA Types and Cure Systems

  • Choi, Sung-Seen;Bae, Jong Woo;Kim, Jung-Soo;Han, Dong-Hun
    • Elastomers and Composites
    • /
    • v.51 no.3
    • /
    • pp.212-217
    • /
    • 2016
  • Influence of poly(ethylene-co-vinyl acetate) (EVA) types and cure systems on cure characteristics of foaming EVA compounds were investigated. Three kind EVAs with different VA contents were employed. Influence of triallyl cyanurate (TAC) and dicumylperoxide (DCP) content on the cure characteristics were examined. The minimum torque ($T_{min}$) and delta torque (${\Delta}T$) decreased as the VA content increased. The ${\Delta}T$ was increased by adding TAC and by increasing the DCP content. For the foaming EVA compounds without TAC, the cure times such as the minimum cure time ($t_{min}$), scorch time ($t_2$), and optimal cure time ($t_{90}$) did not show a specific trend according to the DCP contents. For the foaming EVA compounds containing TAC, the cure times decreased as the DCP content increased. From the experimental results, it was found that efficienct DCP/TAC ratio for improvement of the crosslink density was 1.1~2.0.

A Study on the Elements(MORT-TAC) of Situation Assessment at Disaster Sites (재난현장 상황평가 고려요소(MORT-TAC)에 관한 연구)

  • Kim, Sung-Geun;Lee, Young-Jai
    • Journal of Digital Convergence
    • /
    • v.15 no.1
    • /
    • pp.117-127
    • /
    • 2017
  • Even well trained personnel may fall victim to panic, and a wrong assessment of the situation can turn a small accident into a huge disaster. At the disaster site, the event is commonly broadcasted in real time and is unfiltered. Thus, the commander of the site must be able to accurately assess the scene while not missing out on key considerations. Despite the necessity of good situational assessment, there is barely any research on this topic. This study utilizes METT-TC(Mission, Enemy, Troops, Terrain and weather, Time available, and Civil considerations) which is used by militaries to assess combat situations, and proposes MORT-TAC(Mission, Object, Resources available, Terrain and weather, Time available, Ability, and Civil considerations) as factors to consider in effectively controlling the disaster site. The standard model is used for assessing disaster scenes by applying the Delphi analytical method on each sub-factor of MORT-TAC.

The Surface Energy Change of TAC Film Treated by an Atmospheric Pressure Plasma (대기압 플라즈마 처리에 의한 TAC 필름의 표면에너지 변화)

  • Lee, Chang-Ho;Jung, Do-Young;Park, Young-Jik;Song, Hyun-Jig;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.12
    • /
    • pp.184-190
    • /
    • 2009
  • Tri-acetyl-cellulose(TAC) film surface was modified by atmospheric-pressure plasma technique to obtain the hydrophilic functional groups and improve the contact angle. TAC film was modified with N2 plasma ionized in dielectric barrier discharge(DBD) reactor under atmospheric pressure. We measured the change of the contact angle and the surface energy with respect to the plasma treatment conditions such as plasma treatment power, discharge gap and N2 gas flow rate. As the plasma treatment speed of 100[mm/sec], the plasma treatment power of 1.5[kW], discharge gap 2[mm] and the $N_2$ gas flow rate 140[LPM], the best contact angle and the highest surface energy were obtained. The degree of hydrophilization depended strongly on the plasma-treating time and discharge power.

Seminal reactive oxygen species and total antioxidant capacity: Correlations with sperm parameters and impact on male infertility

  • Subramanian, Vidyalakshmi;Ravichandran, Aishwarya;Thiagarajan, Nivethitha;Govindarajan, Matheswari;Dhandayuthapani, Silambuchelvi;Suresh, Sujatha
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.45 no.2
    • /
    • pp.88-93
    • /
    • 2018
  • Objective: The aim of this study was to measure reactive oxygen species (ROS) production and total antioxidant capacity (TAC) in the seminal fluid of the male partners in couples undergoing intrauterine insemination and to evaluate correlations between these values and their semen parameters. Methods: The study was conducted at Vamsam Fertility Center, Coimbatore, India and enrolled 110 male patients from whom semen samples were collected. ROS production was measured by a thiobarbituric acid reactive species assay, and TAC was measured by a 2,2-diphenyl-2-picrylhydrazyl free radical assay. The differences in the TAC and malondialdehyde (MDA) levels between the subfertile and fertile groups were analysed. Correlations between sperm parameters and TAC and MDA levels were statistically analysed, and cutoff values with respect to the controls were determined. All hypothesis tests used were two-tailed, with statistical significance assessed at the level of p< 0.05. Results: A total of 87 subfertile and 23 fertile men were included in the study. The mean MDA level was significantly higher in the subfertile subjects than in the fertile subjects, and the mean antioxidant level was significantly lower in the subfertile subjects than in the fertile subjects. Seminal MDA levels were negatively associated with sperm concentration, motility, and morphology, whereas the opposite was seen with TAC levels. Conclusion: Measurements of seminal TAC and ROS are valuable for predicting semen quality, and hence predicting the outcomes of fertility treatment.

Heating and Cooling Load Evaluation Study with TAC Based BIN Data (TAC를 반영한 BIN 데이터 기반의 냉난방 부하 변화에 관한 연구)

  • Lee, Kwang Seob;Kim, Yu Jin;Min, Kyung Chon;Lee, Euy Joon;Kang, Eun Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.9
    • /
    • pp.463-471
    • /
    • 2017
  • According to the Korea industrial standard of air conditioning systems (KS C 9306), cooling and heating loads for buildings can be calculated by using maximum and minimum temperature in BIN data. Cooling and heating loads can be determined by building set temperature and ambient temperature. Cooling and heating system capacity of buildings can be normally designed according to determined heating and cooling loads. Cooling and heating system capacity can be reduced by updated BIN data, applying TAC (Technical Advisory Committee) values. In this study, updated BIN data have been analyzed using ambient temperature of 19 areas in Korea for the last 10 years (2005~2014) provided by KMA (Korea Meteorological Administration). Building cooling and heating loads have been calculated following TAC based BIN data. As a result, designed system capacity decreased depending on applying TAC. Those were reduced as 7.1% ($100m^2$ building), 8.7% ($1,000m^2$ building) in cooling capacity, 11.7% in heating capacity when TAC 2.5% applied. And also, it is expected system initial and operating cost by decreasing system capacity.

Weight Changes according to the Period of Chemotherapy Treatments for Breast Cancer (유방암 환자의 화학요법 치료시기에 따른 체중변화)

  • Park, Yun Hee;Yoo, Kyung Hee
    • Journal of Korean Biological Nursing Science
    • /
    • v.18 no.2
    • /
    • pp.94-101
    • /
    • 2016
  • Purpose: This study aimed to evaluate weight changes in women during the period of TAC (docetaxel-doxorubicin-cyclophosphamide) chemotherapy after breast surgery and the differences in weight changes by disease characteristics among Korean women with breast cancer. Methods: The design of this study was retrospective survey research. The subjects of this study were 130 patients with fully completed TAC chemotherapy between January 2012 and April 2015. Body weight before their operation, and at 3 weeks, 6 weeks, 9 weeks, 12 weeks, 15 weeks, and 18 weeks after surgery, as well as general and disease characteristics, were reviewed via their medical charts. Results: The mean age of the patients was 51.2 years. The preoperative (baseline) mean weight was $59.4{\pm}8.44$. Significant weight losses were observed in the initial (1st 3 week) period of TAC chemotherapy compared to the baseline and significant weight losses were observed with the exception of the period 6 weeks after breast surgery. There were significant differences in mean weight changes according to the stage of breast cancer, radiotherapy, and hormone therapy among disease characteristics. Conclusion: It is necessary to study weight changes after breast surgery for the long periods of TAC chemotherapy. Through the accumulated results of studies, nursing programs for breast cancer patients must be developed for the prevention of weight gain in the periods of TAC chemotherapy.