• Title/Summary/Keyword: K-S test

Search Result 24,629, Processing Time 0.053 seconds

Rheological Properties of Bundled Leaf Vegetables Held and Picked-up by Machine (줄기 엽채소의 기계적 파지시 리올로지 특성)

  • Jun, Hyeon-Jong;Kim, Sang-Hun
    • Journal of Biosystems Engineering
    • /
    • v.32 no.6
    • /
    • pp.395-402
    • /
    • 2007
  • This study was carried out as basic researches to develop the leaf vegetable harvester. This study was conducted to investigate physical and rheological properties of bundled leaf vegetables with stem (Chinese leek, Crown daisy and Chamnamul) as test materials held and picked-up by a machine. Stress-strain behavior, stress relaxation, and strain recovery for the bundled materials were analyzed using simple Maxwell model. Physical and rheological properties of the materials were investigated by measuring rupture load, deformation and stress experimentally. Also, strain recovery time when unloading was measured using super high speed camera. Recorded recovery time for stress-strain behavior was0.026 s for Chinese leek with liner strain recovery, 0.046 s for Crown daisy and 0.05 s for Chamnamul with non-linear strain recovery. Furthermore, the strain recovery time for permanent deformation was 0.026 s, 0.046 s, and 0.05 s for Chinese Leek, Crown daisy and Chamnamul, respectively. Finally, strain recovery time and strain recovery ratio for the test materials were 0.17 s, 60.4% in Chinese leek, 0.12 s, 55.3% in Crown daisy, 0.15 s, 58.7% in Chamnamul. Here strain recovery time means that how fast the test materials are recovered from initial deformation and strain recovery ratio means how much the test materials are recovered from initial deformation. The above results show that the test materials can be held enough and moved by the belts.

Development and Performance Test of a l00hp HTS Motor

  • Sohn, M.H.;Baik, S.K.;Lee, E.Y.;Kwon, Y.K.;Yun, M.S.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Ryu, K.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.27-31
    • /
    • 2004
  • This paper describes the development and fabrication of a high temperature superconducting motor which consists of HTS rotor and air-core stator. The machine was designed for the rated power of 100hp at 1800 rpm. The HTS field windings are composed of the double-pancake coils wound with AMSC's SUS-reinforced Bi-2223 tape conductor. These were assembled on the support structure and fixed by a bandage of glass-fiber composite. The cooling system is based on the heat transfer mechanism of the thermosyphon by using GM cryocooler as cooling source. The cold head is in contact with the condenser of a Ne-filled thermosyphon. The rotor assembly was tested independently at the stationary state and combined with stator. Characteristic parameters such as reactances, inductances, and time constants were determined to obtain a consistent overview of the machine operation properties. This motor has met all design parameters by demonstrating HTS field winding, cryogenic refrigeration systems and an air-core armature winding cooled with air. The HTS field winding could be cooled down below 30K. No-load test of open-circuit characteristics(OCC) and short-circuit characteristics(SCC) and load test with resistive load bank were conducted in generator mode. Maximum operating current of field winding at 30K was 120A. From OCC and SCC test results synchronous inductance and synchronous reactance were 2.4mH, 0.49pu, respectively. Efficiency of this HTS machine was 93.3% in full load(100hp) test. This paper will present design, construction, and basic experimental test results of the 100hp HTS machine.

Doppler Ultrasound guided modified Allen's Test in Volkmann's Ischemic Contracture Patient with Ulnar Artery Constriction (도플러 초음파 감시하 알렌 검사로 진단한 상지 볼크만 구축 환자의 척골 동맥 협착 - 1례 보고 -)

  • Kim, Chul Hong;Ha, Dong Ho;Kim, Bo Kun;You, Sung Gon
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.2
    • /
    • pp.84-87
    • /
    • 2011
  • We had applied Doppler ultrasound guided modified Allen's test for a Volkmann's ischemic contracture patient who had ulnar artery constriction which was not detected with acoustic Doppler and CT-angiogram preoperatively. We report this case of Volkmann's ischemic contracture with brief review of literatures for awareness of the Doppler-ultrasound guided modified Allen's test.

  • PDF

A Modified Test for the Hollander and Proschan's Test Against Decreasing Mean Residual Life Alternatives

  • Kim, Hwan-Joong;Kim, Jae-Joo
    • Journal of Korean Society for Quality Management
    • /
    • v.22 no.1
    • /
    • pp.152-161
    • /
    • 1994
  • In this paper we develop a test for alternatives representing decreasing mean residual life. The test statistic for decreasing mean residual life, $K_{1n}$, is a modified version of Hollander and Proschan's test $V^*$ and critical constants and large sample approximation are shown to make the test readily applicable. Consistency is also shown for the tests based on $K_{1n}$. And small sample powers for four alernatives are obtained.

  • PDF

A study on the key Issues for implementing the IEC61850 based Gateway (IEC61850 기반의 Gateway 개발을 위한 이슈에 관한 연구)

  • Oh, Moo-Nam;Lee, Suk-Bea;Woo, Chun-Hee;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.91_92
    • /
    • 2009
  • As the increasing integrity of VLSI, the BIST(Built-In Self Test) is used as an effective method to test chips. Generally the pseudo-random test pattern generation is used for BIST. But it requires too many test patterns when there exist random resistant faults. Therefore we propose a mixed test scheme which applies to the circuit under test, a deterministic test sequence followed by a pseudo-random one. This scheme allows the maximum fault coverage detection to be achieved, furthermore the silicon area overhead of the mixed hardware generator can be reduced.

  • PDF

A Numerical Analysis Study for Prototype Crushed-Stone Compaction Pile (실물크기 쇄석다짐말뚝에 대한 수치해석 연구)

  • Hwang, Geun-Bae;Jung, Sung-Min;Lee, Min-Hee;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.66-73
    • /
    • 2004
  • Prototype crushed-stone compaction pile(${\Phi}=700mm$) were constructed on specific test site. Static loading tests for crushed-stone compaction piles were performed. Based on the static loading test results, finite element analysis was performed using software PENTAGON 3D. Numerical analysis were done for the area replacement ratio($a_s$) of $20{\sim}70%$ and $a_s$ was varied as a step of 10%. In the single crushed-stone compaction pile, settlement was decreased as $a_s$ was increased. In the group pile, this tendency was similar. In the in-sit test and numerical analysis, as $a_s$ increased, the stress concentration ratio was increased. But $a_s$ in the numerical analysis were more than that of in-situ test, greatly.

  • PDF

COMS DATS Implementation and Test (통신해양기상위성 데이터 송수신 서브시스템의 구축 및 시험)

  • Park, Durk-Jong;Kim, Su-Jin;Ahn, Sang-Il
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.4
    • /
    • pp.459-470
    • /
    • 2008
  • DATS which is one of three subsystems of IDACS is responsible to receive Sensor Data, LRIT and HRIT in L-Band and transmit LRIT and HRIT in S-Band from/to COMS satellite. This paper shows detailed test procedures used to verify the performance and functionality of DATS after its implementation was completely finished. As a part of efforts to verify key DATS performance, G/T and EIRP were measured by using solar flux density as radio source. Regarding the verification of DATS functionality, RF loop-back test was conducted to validate if there is no BER degradation excepting MODEM/BB implementation loss occurred in the integrated DATS. Integrated with 13m antenna, DATS successfully restored image from received MTSAT-1R broadcasting data, LRIT and HRIT, of which frequencies are all L-Band. S-Band transmission was also verified through test antenna placed away from 13m antenna by measuring real LRIT and HRIT spectrum in S-Band. From those test results, DATS is determined to be fully ready to communicate with COMS in L-Band and S-Band.

Analysis of Comparison Test and Measurement Error Factor for I - V Performance of Photovoltaic Module (PV모듈 발전성능 비교시험과 계측편차 요인 분석)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.70-75
    • /
    • 2009
  • In this experiment, we did sampling 6 kinds of photovoltaic modules and analyzed the discrepancy of measurement results between l laboratory and 4 PV makers to have performance repeatability at Standard Test Condition(STC) condition. From the KIER's results, Korea's standard test laboratory, other laboratory showed -10% measurement variation. The causes came from correction of reference cell, test condition and the state of skill. Form the comparison test, we analyzed the problems. But three PV maker reduced measurement variation, other one PV maker and one test laboratory didn't improve the problems of correction of reference cell, test condition and the state of skill. Also, High Efficiency Module had a big discrepancy of -10.0$\sim$-6.2% among 3 laboratories which have a less than 10msec light pulse duration time. This made low spectrum response speed so the Fill Factor decreased maximum output power under 10msec light pulse duration time

Life Estimation of Organic Light Emission Diode by Accelerated Test (유기발광 다이오드의 가속 수명 시험에 관한 연구)

  • Choi, Young-Tea;Cho, Jai-Rip
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.61-66
    • /
    • 2010
  • Organic light emitting diode(OLED) has been developed fast from 1963 when electric light emitting phenomenon was discovered. PMOLED(passive matrix OLED) is producted earlier than AMOLED(active matrix OLED). PMOLED is mainly mounted at sub display, but AMOLED is mounted at main display. Nowadays AMOLED is expanded to PMP(portable multimedia players), navigation and TV market. Even thought OLED's market is opening to many applications, OLED's life is worried until now. If we know about OLED's real life, we need time to test so much time over 20,000hrs. Realistically, there is difficult to test such as long time with products from the information-technology sector having a short life cycle. In this paper, we study about OLED's accelerated test to reduce life test by current. We can design OLED's accelerated life model by the result of test. The model consists of design variables like ratio of light emitting, organic material structure, condition of aging, etc. In conclusion, this model can be applied to study about organic material, machine and manufacturing process etc, and also it's possible to develop a method of manufacturing process & materials, so we need to study on the subject of this paper continuously.

The Reliability and Validity of Korean Pediatric Functional Muscle Testing in Children with Motor Disorder

  • Seo, Hye-Jung;Kim, Joong-Hwi
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.4
    • /
    • pp.232-242
    • /
    • 2016
  • Purpose: This study was conducted to develop a Korean version of the pediatric functional muscle test (K-PFMT) for children with motor developmental disorders, and to verify its reliability and validity. Methods: The subjects were 40 children, aged below 5 years. Each was scored on the K-PFMT by 14 physical therapists to determine inter-rater reliability and internal consistency. Additionally, 3 of the 14 therapists tested 20 children again one or two weeks later to determine test-retest reliability. The internal consistency was calculated by Cronbach's alpha. The inter-rater and test-retest reliability were calculated using the intraclass correlation coefficient (ICC). One-way ANOVA and the paired t-test were used to compare differences among the three evaluator groups and between the test and retest group. Concurrent validity was evaluated by Pearson's correlation with a total score of GMFM. Results: Chronbach's alpha was over 0.98 for each test item and 0.99 for the total items. There was no significant differences in the score of K-PFMT among the three evaluator groups except for a few items. The test-retest ICC was from 0.89 to 1.00 and from 0.82 to 1.00, respectively. There was no significant difference between the test and retest group, except for a few items. There were high significant correlations between K-PFMT and GMFM. Conclusion: This study showed that a K-PFMT with relatively high reliability and validity was successfully developed. The K-PFMT will be a useful tool for measurement of muscle strength of children with motor developmental disorder.