• Title/Summary/Keyword: K Corporation

Search Result 9,846, Processing Time 0.042 seconds

Whitening Effects of Adamantyl Benzamide Derivatives (Adamantyl Benzamide 유도체의 미백효과)

  • Baek, Heung Soo;Ahn, Soo Mi;Woo, Byoung Young;Cho, Young Seok;Choi, Soo Jeong;Rho, Ho Sik;Byoun, Kyoung Hee;Shin, Song Seok;Park, Young Ho;Joo, Yung Hyup
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.39 no.2
    • /
    • pp.127-132
    • /
    • 2013
  • The structure activity relationship of polyhydroxylated benzamide derivatives for whitening effects was examined. The adamantyl benzamide derivatives with catechol (3,4-dihydroxyphenyl) of B-ring part showed good anti-melanogenesis activity, but the inhibitory activity of mono-hydroxyphenyl (3-OH or 4-OH) or 3,4-dimethoxyphenyl substituted derivatives was decreased or lost. Therefore the catechol unit was appeared to be the crucial factor for the inhibition of melanogenesis. And the existence of 2-OH of A-ring part had minor influence on the activity, the length of carbon chain between A-ring and B-ring was also not the major factor for the anti-melanogenesis activity.

Development of Wind Turbine Simulation System Based on IEC 61400-25 Standard

  • Lee, Jae-Kyung;Kim, Dong-Wook;Kim, Seok-Tae;Chae, Chang-Hun;Park, Joon-Young
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.349-359
    • /
    • 2019
  • This paper introduces a wind turbine simulation system based on the IEC 61400-25 standard to simulate different kinds of wind turbines. A unified communication protocol was required for monitoring and control of wind turbines, because manufacturers had used their own protocols for their turbines. As a result of such an effort, the international standard IEC 61400-25 was established. To implement the schema of IEC 61400-25, the IEC61850 SCL was modified and applied to the simulation system, which enabled the system to be compatible with heterogeneous wind turbine information models. The developed simulation system can be used for interoperability tests with a new type of wind turbine information model.

A Study on Repowering of Domestic Aged Coal-fired Power Plant

  • Baek, SeHyun;Kim, YoungJoo;Kim, HyunHee;Park, SangBin;Jang, JiHoon
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.1
    • /
    • pp.35-39
    • /
    • 2017
  • Recently, the public opinion is growing that the main cause of greenhouse gas, fine dust and nitrogen oxide, sulfuric acid emission is coal-fired power plant, and now the decommission or conversion to other clean fuel is being demanded. However, it is a huge national loss to decommission coal-fired power plant with remaining life, and also simple fuel converting to natural gas will lead to drastic rise on power generating cost. Therefore, this study aims to provide the analysis result about the reduction effect of $CO_2$, environment emission, and to influence to power plant performance and facilities when repowering with adding gas turbine is applied to domestic aged coal-fired power plant.

Study on DAS-Based Time Synchronization for Improving Reliability of Section Load Estimation

  • Lee, In-tae;Lee, Ji-Hoon;Jung, Nam-Joon;Jung, Young-Beom;Lee, Byung-sung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.61-65
    • /
    • 2015
  • For effective distribution planning and operation, we need a reliable estimation of operation capacity. But it is difficult to ensure reliability due to the low accuracy of section load data, which is used as a basis in estimating the operation capacity. This paper discusses how to improve the accuracy of section load data by analyzing the existing method of estimating the section load, using statistical techniques to adjust the acquired data, and using the section load estimation algorithm to estimate the section load based on the adjusted data.

Development of Noise Source Detection System using Array Microphone in Power Plant Equipment (배열형 음향센서를 이용한 발전설비 소음원 탐지시스템 개발)

  • Sohn, Seok-Man;Kim, Dong-Hwan;Lee, Wook-Ryun;Koo, Jae-Raeyang;Hong, Jin-Pyo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.99-104
    • /
    • 2015
  • In this study, it has been initiated to investigate the specific abnormal vibration signal that has been captured in the power equipment. Array Microphone can be used in order to detect the direction and the position of the noise source. It is possible to track the abnormal mechanical noise in the power plant by utilizing the program and the microphone array system developed from this research. Array microphone system can be operated as a constant monitoring system.

Development of Visualization Model for Probabilistic Analysis of Cascading Failure Risks (확률론적 연쇄사고 분석을 위한 시각화 모형 개발)

  • Choy, Youngdo;Baek, Ja-hyun;Kim, Taekyun;Jeon, Dong-hoon;Yoon, Gi-gab;Park, Sang-Ho;Goo, Bokyung;Hur, Jin
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.1
    • /
    • pp.13-17
    • /
    • 2018
  • According to the recent blackouts, large blackouts can be described by cascading outages. Cascading outage is defined by sequential outages from an initial disturbance. Sequential and probabilistic approach are necessary to minimize the blackout damage caused by cascading outages. In addition, conventional cascading outage analysis models are computationally complex and have time constraints, it is necessary to develop the new analytical techniques. In this paper, we propose the advance visualization model for probabilistic analysis of cascading failure risks. We introduce the visualization model for identifying size of cascading and potential outages and estimate the propagation rate of sequential outage simulation. The proposed model is applied to Korean power systems.

A study on Parallel running Hydroelectric power Generation breakdown through Reactive Current (무효횡류에 의한 병렬 운전 수력발전소 고장에 관한 연구)

  • Ha, Sung-Jong;Kim, Ji-Chan;Ahn, Jae-Hu;Byeon, Gyu-Yong;Pi, In-Seop;Ye, Cheol-Hae;Jeong, Ho-Un
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.214-215
    • /
    • 2011
  • 2대의 교류발전기 G1과 G2가 병렬운전 중 일 때 내부 기전력 E1, E2는 같은 위상이지만, 크기가 E1>E2로 될 때 두 발전기 사이에는 전위차가 있으므로 횡류 Ic가 흐르게 된다. 남강수력발전소는 주변압기(15MVA, 3.45/66kV) 한대에 수차발전기(7MVA) 2대가 병렬로 운전 중인데, 남강수력 제1호 수차발전기 AVR 시스템의 고장(RS 1기판)으로 G1 발전기의 내부 유기전압과 G2 발전기의 내부 유기전압에 차가 생기고, 이 양자의 차 전압을 전원으로 하여 발전기 G1과 G2를 환류하는 전류가 발생하여 발전 기동 중 비상정지 하였다. 본 논문에서는 고장원인 분석과정 및 AVR 시스템 보수 전 후 파형 비교 및 사고원인을 논하고자 한다.

  • PDF

The consideration of the Partial Discharge Diagnosis System in Chungju Hydro (충주 수력 부분방전 진단 시스템 신뢰성 고찰)

  • Ok, Yeon-Ho;Lim, Jae-Il;Park, Ji-Kun;Kwak, Won-Ku;Lee, Jae-Heung;Choi, Hyeong-Cheol;Lee, Nam-Hyung;Shin, Byoung-Chol
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2013_2014
    • /
    • 2009
  • 진단기술은 기기의 열화 현상 및 이상 현상으로 진전되는 특성을 측정하여 향후 발생이 예상되는 이상을 조기에 발견하는 것을 목적으로 한다. 기기를 정밀 진단, 분석하여 잔여 수명을 평가하고 적절한 대체계획을 수립함으로써 신뢰도 향상 및 경제적인 설비 운용이 가능하다. 본 논문에서는 수력 발전기 운전 중 부분방전 진단 시스템을 이용하여 수력 발전기의 운전 중에 발생하는 부분방전 신호를 실시간으로 측정, 분석하고 수력 발전기 권선의 절연 상태를 감시 진단하여 기기의 열화 및 이상 현상등을 조기에 발견하고 발전설비의 신뢰도를 향상시킬 수 있는 방안을 제시하고자 한다.

  • PDF

Effects of Stress Mismatch on the Electrical Characteristics of Amorphous Silicon TFTs for Active-Matrix LCDs

  • Lee, Yeong-Shyang;Chang, Jun-Kai;Lin, Chiung-Wei;Shih, Ching-Chieh;Tsai, Chien-Chien;Fang, Kuo-Lung;Lin, Hun-Tu;Gan, Feng-Yuan
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.729-732
    • /
    • 2006
  • The effect of stress match between silicon nitride ($SiN_2$) and hydrogenated amorphous silicon (a-Si:H) layers on the electrical characteristics of thin-film transistors (TFTs) has been investigated. The result shows that modifying the deposition conditions of a Si:H and $SiN_2$ thin films can reduce the stress mismatch at a-Si:H/SiNx interface. Moreover, for best a-Si:H TFT characteristics, the internal stress of gate $SiN_2$ layer with slightly nitrogen-rich should be matched with that of a-Si:H channel layer. The ON current, field-effect mobility, and stability of TFTs can be enhanced by controlling the stress match between a-Si:H and gate insulator. The improvement of these characteristics appears to be due to both the decrease of the interface state density between the a-Si:H and SiNx layer, and the good dielectric quality of the bottom nitride layer.

  • PDF