• Title/Summary/Keyword: Junction Detecting

Search Result 22, Processing Time 0.031 seconds

Anomalous Event Detection in Traffic Video Based on Sequential Temporal Patterns of Spatial Interval Events

  • Ashok Kumar, P.M.;Vaidehi, V.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.1
    • /
    • pp.169-189
    • /
    • 2015
  • Detection of anomalous events from video streams is a challenging problem in many video surveillance applications. One such application that has received significant attention from the computer vision community is traffic video surveillance. In this paper, a Lossy Count based Sequential Temporal Pattern mining approach (LC-STP) is proposed for detecting spatio-temporal abnormal events (such as a traffic violation at junction) from sequences of video streams. The proposed approach relies mainly on spatial abstractions of each object, mining frequent temporal patterns in a sequence of video frames to form a regular temporal pattern. In order to detect each object in every frame, the input video is first pre-processed by applying Gaussian Mixture Models. After the detection of foreground objects, the tracking is carried out using block motion estimation by the three-step search method. The primitive events of the object are represented by assigning spatial and temporal symbols corresponding to their location and time information. These primitive events are analyzed to form a temporal pattern in a sequence of video frames, representing temporal relation between various object's primitive events. This is repeated for each window of sequences, and the support for temporal sequence is obtained based on LC-STP to discover regular patterns of normal events. Events deviating from these patterns are identified as anomalies. Unlike the traditional frequent item set mining methods, the proposed method generates maximal frequent patterns without candidate generation. Furthermore, experimental results show that the proposed method performs well and can detect video anomalies in real traffic video data.

The Characteristics of UV Generation and Aging Materials in According to Surface Discharge (연면방전에 의한 폴리머애자의 자외선 발생과 열화특성)

  • Shong, Kil-Mok;Bang, Sun-Bae;Kim, Chong-Min;Kim, Young-Seok;Jung, Jin-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.9
    • /
    • pp.1606-1611
    • /
    • 2008
  • Recently, The diagnosis techniques of electric facilities are developed on live line. This paper describes the discharge characteristics of polymer insulator(EPDM A type). Keeping the facilities in good working order, the goal of this paper will provide the information to enable user to easily judge conditions of facilities on the spot. The performance of polymer insulator is assessed from the KS C IEC 60270 and CEA LWIWG-01(96)(Tracking Wheel Test). As the results, UV generation patterns of polymer insulator grow like a jellyfish shape follow the ramping voltage. Discharging UVs are detected at about 31.25% of breakdown voltage. Just then, dimension of UV image is about $0.84cm^{2}$. The dimension of max. UV image is about $297.4cm^{2}$ at $160kV(V_{bd})$. The position of UV generation due to surface discharge of polymer insulator is the center of insulator in the early, then moved the ground side and the last, UV image moved through the junction part of source side. Surface of aged polymer insulator is cracked and faded due to arc. UV absorption spectrum of polymer insulator are appeared the C-H bond of scissoring vib. at $1014cm^{-1}$ and C=O bond of recombination structure. Also, recombined UV absorption peak such as C-H, N-H, and O-H is detected at the $3321cm^{-1}$. Through the paper, there are inspection data which are the relations between surface discharge of polymer insulator and UV detecting image.

A Self-Organizing Angle-based Routing Protocol for Urban Environments (도심환경에서의 자율 군집적인 각도 기반 라우팅 프로토콜)

  • Oh, Seungyong;Cho, Keuchul;Kim, Junhyung;Yun, Jeongbae;Seong, Gihyuk;Han, Kijun
    • Journal of Digital Convergence
    • /
    • v.11 no.10
    • /
    • pp.379-385
    • /
    • 2013
  • MANET is not suitable to be applied to vehicle environments because of frequent path loss and path re-routing. To solve these problem, It is known that location-based routing protocol VANET is efficient. But, the VANET algorithm does not consider urban environments due to frequent vehicle movement and jamming by tall building. In this paper, we propose an efficient routing protocol to improve transfer efficiency and reduce transfer hop count. in urban networks.

Research of an On-Line Measurement Method for High-power IGBT Collector Current

  • Hu, Liangdeng;Sun, Chi;Zhao, Zhihua
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.362-373
    • /
    • 2016
  • The on-line measurement of high-power IGBT collector current is important for the hierarchical control and short-circuit and overcurrent protection of its driver and the sensorless control of the converter. The conventional on-line measurement methods for IGBT collector current are not suitable for engineering measurement due to their large-size, high-cost, low-efficiency sensors, current transformers or dividers, etc. Based on the gate driver, this paper has proposed a current measuring circuit for IGBT collector current. The circuit is used to conduct non-intervention on-line measurement of IGBT collector current by detecting the voltage drop of the IGBT power emitter and the auxiliary emitter terminals. A theoretical analysis verifies the feasibility of this circuit. The circuit adopts an operational amplifier for impedance isolation to prevent the measuring circuit from affecting the dynamic performance of the IGBT. Due to using the scheme for integration first and amplification afterwards, the difficult problem of achieving high accuracy in the transient-state and on-state measurement of the voltage between the terminals of IGBT power emitter and the auxiliary emitter (uEe) has been solved. This is impossible for a conventional detector. On this basis, the adoption of a two-stage operational amplifier can better meet the requirements of high bandwidth measurement under the conditions of a small signal with a large gain. Finally, various experiments have been carried out under the conditions of several typical loads (resistance-inductance load, resistance load and inductance load), different IGBT junction temperatures, soft short-circuits and hard short-circuits for the on-line measurement of IGBT collector current. This is aided by the capacitor voltage which is the integration result of the voltage uEe. The results show that the proposed method of measuring IGBT collector current is feasible and effective.

Development of a multiplex PCR method for identification of four genetically modified maize lines and its application in living modified organism identification

  • Park, Jin Ho;Seol, Min-A;Eum, Soon-Jae;Kim, Il Ryong;Lim, Hye Song;Lee, Jung Ro;Choi, Wonkyun
    • Journal of Plant Biotechnology
    • /
    • v.47 no.4
    • /
    • pp.309-315
    • /
    • 2020
  • Advances in biotechnology have led to progress in crop genetic engineering to improve agricultural productivity. The use of genetically modified (GM) crops has increased, as have consumers' and regulators' concerns about the safety of GM crops to human health, and ecological biodiversity. As such, the identification of GM crops is a critical issue for developers and distributors, and their labeling is mandatory. Multiplex polymerase chain reaction (PCR) has been developed and its use validated for the detection and identification of GM crops in quarantine. Herein, we established a simultaneous detection method to identify four GM maize events. Event-specific primers were designed between the junction region of transgene and genome of four GM maize lines, namely 5307, DAS-40278-9, MON87460, and MON87427. To verify the efficiency and accuracy of the multiplex PCR we used specificity analysis, limit of detection evaluation, and mixed certified reference materials identification. The multiplex PCR method was applied to analyze 29 living, modified maize volunteers collected in South Korea in 2018 and 2019. We performed multiplex PCR analysis to identify events and confirmed the result by simplex PCR using each event-specific primer. As a result, rather than detecting each event individually, the simultaneous detection PCR method enabled the rapid analysis of 29 GM maize volunteers. Thus, the novel multiplex PCR method is applicable for living modified organism volunteer identification.

Recognition Performance Improvement of QR and Color Codes Posted on Curved Surfaces (곡면상에 부착된 QR 코드와 칼라 코드의 인식률 개선)

  • Kim, Jin-soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.3
    • /
    • pp.267-275
    • /
    • 2019
  • Currently, due to the widespread use of a smartphone, QR codes allow users to access a variety of added services. However, the QR codes posted on curved surfaces tend to be non-uniformly illuminated and bring about the decline of recognition rate. So, in this paper, the block-adaptive binarization policy is adopted to find an optimal threshold appropriate for bimodal image like QR codes. For a large block, its histogram distribution is found to get an initial threshold and then the block is partitioned to reflect the local characteristics of small blocks. Also, morphological operation is applied to their neighboring boundary at the discontinuous at the QR code junction. This paper proposes an authentication method based on the color code, uniquely painted within QR code. Through a variety of practical experiments, it is shown that the proposed algorithm outperforms the conventional method in detecting QR code and also maintains good recognition rate up to 40 degrees on curved surfaces.

Diagnosis of Functional Nasolacrimal Duct Obstruction Using Dacryoscintigraphy (누비공신티그라피를 이용한 기능적 누도폐쇄의 진단)

  • Lim, Hyun-Wook;Sohn, Hyung-Sun;Kim, Euy-Neyng;Chung, Yong-An;Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.508-515
    • /
    • 2000
  • Purpose: To evaluate the value of dacryoscintigraphy in the assessment of patients with a clinical diagnosis of functional nasolacrimal duct obstruction. Materials and Methods: Dacryoscintigraphy was performed in symptomatic 35 lacrimal drainage systems in 18 patients (age range: $37{\sim}76$, 8 males, 10 females) that were patent on syringing. Results: Abnormalities were detected with dacryoscintigraphy in 75.8% of systems. The positive scintigrams were subdivided into those demonstrating prelacrimal sac delay (31.8%), delay at the lacrimal sac/junction (40.9%), or delay within the duct (21%). Conclusion: Dacryoscintigraphy is noninvasive useful technique in the assessment of the functional nasolacrimal duct obstruction and very sensitive at detecting abnormalities in patients with lid laxity caused by senile change and facial nerve palsy.

  • PDF

On-site Water Nitrate Monitoring System based on Automatic Sampling and Direct Measurement with Ion-Selective Electrodes

  • Kim, Dong-Wook;Jung, Dae-Hyun;Cho, Woo-Jae;Sim, Kwang-Cheol;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.350-357
    • /
    • 2017
  • Purpose: In-situ monitoring of water quality is fundamental to most environmental applications. The high cost and long delays of conventional laboratory methods used to determine water quality, including on-site sampling and chemical analysis, have limited their use in efficiently managing water sources while preventing environmental pollution. The objective of this study was to develop an on-site water monitoring system consisting mainly of an Arduino board and a sensor array of multiple ion selective electrodes (ISEs) to measure the concentration of $NO_3$ ions. Methods: The developed system includes a combination of three ISEs, double-junction reference electrode, solution container, sampling system consisting of three pumps and solenoid valves, signal processing circuit, and an Arduino board for data acquisition and system control. Prior to each sample measurement, a two-point normalization method was applied for a sensitivity adjustment followed by an offset adjustment to minimize the potential drift that could occur during continuous measurement and standardize the response of multiple electrodes. To investigate its utility in on-site nitrate monitoring, the prototype was tested in a facility where drinking water was collected from a water supply source. Results: Differences in the electric potentials of the $NO_3$ ISEs between 10 and $100mg{\cdot}L^{-1}$ $NO_3$ concentration levels were nearly constant with negative sensitivities of 58 to 62 mV during the period of sample measurement, which is representative of a stable electrode response. The $NO_3$ concentrations determined by the ISEs were almost comparable to those obtained with standard instruments within 15% relative errors. Conclusions: The use of the developed on-site nitrate monitoring system based on automatic sampling and two-point normalization was feasible for detecting abrupt changes in nitrate concentration at various water supply sites, showing a maximum difference of $4.2mg{\cdot}L^{-1}$ from an actual concentration of $14mg{\cdot}L^{-1}$.

Fabrication and Characteristics of Infrared Photodiode Using Insb Wafer with p-i-n Structure (p-i-n 구조의 InSb 웨이퍼를 이용한 적외선 광다이오드의 제조 및 그 특성)

  • Cho, Jun-Young;Kim, Jong-Seok;Son, Seung-Hyun;Lee, Jong-Hyun;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.239-246
    • /
    • 1999
  • A highly sensitive photovoltaic infrared photodiode was fabricated for detecting infrared light in $3{\sim}5\;{\mu}m$ wavelength range on InSb wafer with p-i-n structure grown by MOCVD. Silicon dioxide($SiO_2$) insulating films for the junction interface and surface of photodiode were prepared using RPCVD because InSb has low melting point and evaporation temperature. After formation of In ohmic contacts by thermal evaporation, the electrical properties of the photodiode were characterized in dark state at 77K. A product of zero-bias resistance and area($R_0A$) showed $1.56{\times}10^6\;{\Omega}{\cdot}cm^2$ that satisfied BLIP(background limited infrared photodetector) condition. When the photodiode was tested under infrared light, the normalized detectivity of about $10^{11}\;cm{\cdot}Hz^{1/2}{\cdot}W^{-1}$ was obtained. we successfully fabricated a unit cell with InSb IR array with good quantum efficiency and high detectivity.

  • PDF

Optimization of Soldering Process of Sn-3.0Ag-0.5Cu and Sn-1.0Ag-0.7Cu-1.6Bi-0.2In Alloys for Solar Combiner Junction Box Module (태양광 접속함 정션박스 모듈 적용을 위한 Sn-3.0Ag-0.5Cu 및 Sn-1.0Ag-0.7Cu-1.6Bi-0.2In 솔더링의 공정최적화)

  • Lee, Byung-Suk;Oh, Chul-Min;Kwak, Hyun;Kim, Tae-Woo;Yun, Heui-Bog;Yoon, Jeong-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.25 no.3
    • /
    • pp.13-19
    • /
    • 2018
  • The soldering property of Pb-containing solder(Sn-Pb) and Pb-free solders(Sn-3.0Ag-0.5Cu and Sn-1.0Ag-0.7Cu-1.6Bi-0.2In) for solar combiner box module was compared. The solar combiner box module was composed of voltage and current detecting modules, diode modules, and other modules. In this study, solder paste printability, printing shape inspection, solder joint property, X-ray inspection, and shear force measurements were conducted. For optimization of Pb-free soldering process, step 1 and 2 were divided. In the step 1 process, the printability of Pb-containing and Pb-free solder alloys were estimated by using printing inspector. Then, the relationship between void percentages and shear force has been estimated. Overall, the property of Pb-containing solder was better than two Pb-free solders. In the step 2 process, the property of reflow soldering for the Pb-free solders was evaluated with different reflow peak temperatures. As the peak temperature of the reflow process gradually increased, the void percentage decreased by 2 to 4%, but the shear force did not significantly depend on the reflow peak temperature by a deviation of about 0.5 kgf. Among different surface finishes on PCB, ENIG surface finish was better than OSP and Pb-free solder surface finishes in terms of shear force. In the thermal shock reliability test of the solar combiner box module with a Pb-free solder and OSP surface finish, the change rate of electrical property of the module was almost unchanged within a 0.3% range and the module had a relatively good electrical property after 500 thermal shock cycles.