The using of megavoltage computed tomography in image-guided brachytherapy for cervical cancer: a case report

  • Tharavichitkul, Ekkasit;Janla-or, Suwapim;Wanwilairat, Somsak;Chakrabandhu, Somvilai;Klunklin, Pitchayaponne;Onchan, Wimrak;Supawongwattana, Bongkot;Galalae, Razvan M.;Chitapanarux, Imjai
    • Radiation Oncology Journal
    • /
    • v.33 no.2
    • /
    • pp.155-159
    • /
    • 2015
  • We present a case of cervical cancer treated by concurrent chemoradiation. In radiation therapy part, the combination of the whole pelvic helical tomotherapy plus image-guided brachytherapy with megavoltage computed tomography of helical tomotherapy was performed. We propose this therapeutic approach could be considered in a curative setting in some problematic situation as our institution.

The association of rectal equivalent dose in 2 Gy fractions (EQD2) to late rectal toxicity in locally advanced cervical cancer patients who were evaluated by rectosigmoidoscopy in Faculty of Medicine, Chiang Mai University

  • Tharavichtikul, Ekkasit;Meungwong, Pooriwat;Chitapanarux, Taned;Chakrabandhu, Somvilai;Klunklin, Pitchayaponne;Onchan, Wimrak;Wanwilairat, Somsak;Traisathit, Patrinee;Galalae, Razvan;Chitapanarux, Imjai
    • Radiation Oncology Journal
    • /
    • v.32 no.2
    • /
    • pp.57-62
    • /
    • 2014
  • Purpose: To evaluate association between equivalent dose in 2 Gy (EQD2) to rectal point dose and gastrointestinal toxicity from whole pelvic radiotherapy (WPRT) and intracavitary brachytherapy (ICBT) in cervical cancer patients who were evaluated by rectosigmoidoscopy in Faculty of Medicine, Chiang Mai University. Materials and Methods: Retrospective study was designed for the patients with locally advanced cervical cancer, treated by radical radiotherapy from 2004 to 2009 and were evaluated by rectosigmoidoscopy. The cumulative doses of WPRT and ICBT to the maximally rectal point were calculated to the EQD2 and evaluated the association of toxicities. Results: Thirty-nine patients were evaluated for late rectal toxicity. The mean cumulative dose in term of EQD2 to rectum was 64.2 Gy. Grade 1 toxicities were the most common findings. According to endoscopic exam, the most common toxicities were congested mucosa (36 patients) and telangiectasia (32 patients). In evaluation between rectal dose in EQD2 and toxicities, no association of cumulative rectal dose to rectal toxicity, except the association of cumulative rectal dose in EQD2 >65 Gy to late effects of normal tissue (LENT-SOMA) scale ${\geq}$ grade 2 (p = 0.022; odds ratio, 5.312; 95% confidence interval, 1.269-22.244). Conclusion: The cumulative rectal dose in EQD2 >65 Gy have association with ${\geq}$ grade 2 LENT-SOMA scale.

An Experimental Dosimetry of Irregularly Shaped Fields Using Therapeutic Planning Computer (치료계획용 컴퓨터를 이용한 부정형조사면의 선량분포에 관한 실험)

  • Kwon Hyoung Cheol;Oh Yoon Kyeong;Yoon Sei Chul;Bahk Young Whee
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.281-285
    • /
    • 1984
  • The authors have intended to measure intrinsic dose distribution by Farmer dosimeter in irregularly shaped fields such as L.M and T shape models in order to determine dose inhomogeneity in those models. We made 2 off·axis points in each model and measured the depth dose at 1.5, 5 and 9cm below surface. The results showed $l\~3\%$ dose discrepancy between 2 points. We also measured the depth dose by geometric approximation and computer calculation in those models, and came to the conclusion that computer calculation using Clarkson's principle is simpler and the measurements are closer to the ideal data obtained by the experiment in three models of irregularly shaped fields than those of geometric approximation method.

  • PDF

Annual Statistics of Radiation Therapy -1990- (방사선 치료 전국 통계 -1990-)

  • 대한치료방사선과학회
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.361-367
    • /
    • 1991
  • This paper on the status of radiotherapy machine and related facilities, clinical activities and radiation safety management is based on the statistical data which collected through the questionaire sent to a total number of 37 hospitals holding the Department of Therapeutic Radiology in Korea. It is true that the quality of instruments installed in the hospitals equal to that of the instrument in the industrialized conuntries' hospitals. But the clinical specialists and physicists who can utilize such instruments fall short of the required number, which might be a main factor in hindering the development of therapeutic radiology of Korea. According to the nation-wide cancer statistics, we can estimate the number of annual cancer patients as 45,000 to 50,000. As a result, probably around 25,000 should receive radiation therapy. It is expected that in the future the number of cancer patients to whom radiation therapy should be applied will become twice as much as that of the cancer patients in 1990. Given such a condition, the problem facing the Korean Society of Therapeutic Radiology now is to increase the number of medical doctors and physicists.

  • PDF

Radiotherapy of Patient with Implanted Cardiac Pacemaker - Case Report - (심박조율기를 장착한 환자에서의 방사선치료 -증례 보고 -)

  • Wu Hong-Gyun;Kim Bo-Kyoung;Kang Wee-Saeng;Park Jin Hong
    • Radiation Oncology Journal
    • /
    • v.18 no.1
    • /
    • pp.46-50
    • /
    • 2000
  • A 70 years old female patient with thyroid cancer received palliative radiation therapy for neck swelling and hemoptysis. She had a cardiac pacemaker under her chest due to complete AV block since 8 years ago. We present clinical detail and review previously reported articles.

  • PDF

Total Body Irradiation Technique : Basic Data Measurements and In Vivo Dosimetry (방사선 전신 조사 : 기본 자료 측정 및 생체내에서 선량 측정)

  • Choi Dong-Rak;Choi Ihl Bohng;Kang Ki Mun;Shinn Kyung Sub;Kim Choon Choo
    • Radiation Oncology Journal
    • /
    • v.12 no.2
    • /
    • pp.219-223
    • /
    • 1994
  • This paper describes the basic data measurements for total body irradiation with 6 Mv photon beam including compensators design. The technique uses bilateral opposing fields with tissue compensators for the head, neck, lungs, and legs from the hip to toes. In vivo dosimetry was carried out for determining absorbed dose at various regions in 7 patients using diode detectors(MULTIDOSE,k Model 9310, MULTIDATA Co., USA). As a results, the dose uniformity of${\pm}3.5{\%}$(generally, within${\pm}10{\%}$can be achieved with out total body irradiation technique.

  • PDF

A Correction Method of Dose to Attenuation Rate of Transmitting Photon Beam Through Couch Top for Radiosurgery Using Novalis (노발리스를 이용한 방사선 수술시 치료테이블을 투과하는 광자선의 감쇠율에 따른 선량 보정방법)

  • Kim, Sung-Joon;Shin, Hyun-Soo;Ko, Seung-Young;Park, Hye-Li;Kim, Ja-Young;Lee, Bo-Mi;Yea, Ji-Woon;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.12-17
    • /
    • 2011
  • This study has its own goal to deliver the accurate dose on the target volume by calculating and modifying the attenuation rate of photon beam transmitting the couch top with geometric model. The experiment was that the transmission rate and attenuation rate of photon beam transmitting the couch top was predicted by the geometric model, then compared and analyzed with what was measured experimentally based on that. The result showed that the predicted value by the geometric model accorded closely with the experimental value. In addition, in order to judge whether the practical clinical application is available, the point dose, measured after modifying the attenuation rate modelinged according to the treatment plan of a patient of spine radiosurgery, was compared with the one done nothing. The result was that the former showed decreased error range with treatment planned one than the latter. This papers calculated the transmission and attenuation rate with the geometric model transmitting the couch top and verified it experimentally. This method is expected to be very useful in not only the radiosurgery using Novalis but also the general radiation therapy.

A Trial of 6-MV Linear Accelerator Radiation Therapy (RT) for Breast Cancer (6MV 선형가속기를 사용한 유방암 치료)

  • Yoon S. C.;Kwon H. C.;Oh Y. K.;Kim J. W.;Bahk Y. W.
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.303-309
    • /
    • 1984
  • Radiation therapy(RT) has been used in the treatment of breast cancer for over 80years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internal mammary nodes (IM) and supraclavicular nodes (SCL). Authors tried three-field technique for the treatment of breast cancer using 6-MV linear accelerator, exclusively the department of radiology. Kang-Nam St. Mary's Hospital, at Catholic Medical College. The field junction was checked by a Phantom study and radiation doses measured by film densitometry and TLD. The 3 fields we used in this study were two isocentric opposing tangential fields encompassing the breast, chest wall and occasionally IM and one single anterior field encompassing the axilla and SCL. sing appropriate beam blocks and boluses, we were able to avoid unwanted intrinsic divergency of photon beam. Blocking also enabled us to set-up precise radiation field with ease.

  • PDF

The Pattern of Failure after Definitive Radiotherapy for Squamous Cell Carcinoma of the Lung (편평상피 세포성 폐암의 방사선치료 실패 양상)

  • Jang Yang Suk;Kim Jae Cheol;Ryu Samuel;Park In Kyu
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.45-50
    • /
    • 1989
  • From Feb.1985 to Feb.1988,76 patients with squamous cell carcinoma of the lung treated at the Department of Therapeutic Radiology in Kyungpook National University Hospital were available for the analysis of this study. All patients received radiation of 4000cGy-6600cGy with curative aim. The overall rate of complete response was 25.0% and partial response was 452.6% The complete and partial regression of tumor was 14.3% in patients treated with dose below 5000cGy and 84.1% in the group treated with dose above 5000cGy (p<0.01). The complete response was seen only in the group of patients received radiation at least 6000cGy. The patterns of failure were as follows. The rate of initial intrathoracic recurrence was 52.6% in patients with complete response. The overall rate of failure was 68.8%. Distant metastasis was found in 47.4% of patients. Bone, contralateral lung, and brain were common metastatic sites in decreasing order All of the distant metastases and 80% of local recurrences were found within the first year after treatment.

  • PDF

Dose Characteristics for IORT Applicator of ML-15MDX Electron Beam (ML-15MDX 술중조사용 Applicator에 의한 전자선선량 특성)

  • Choi, Tae-Jin;Lee, Ho-Joon;Kim, Yeung-Ae;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.11 no.2
    • /
    • pp.455-461
    • /
    • 1993
  • Experimental measurements of dose characteristics with pentagonal applicator at nominal energy of 4, 6, 9, 12 and 15 MeV electron beam were performed for intraoperative radiotherapy (IORT) in ML-15MDX linear accelerator. This paper presents the percent depth dose, surface dose, beam flatness and output factors of using the IORT applicator in different electron beam energy. The output factor showed as a 24 percent higher in IORT applicator than that of reference $10{\times}10cm^2$ applicator. The surface dose of using the IORT applicator showed 7.7 and 2.7 percent higher than that of reference field in 4 and 15 MeV electron beam, respectively. In our experiments, the variation of percent depth dose was very small but the output factor and flatnees at 0.5 cm depth have showed a large value in IORT applicator.

  • PDF