• Title/Summary/Keyword: Joule-Thomson refrigerator

Search Result 17, Processing Time 0.023 seconds

Research of Cryogenic Helium Refrigerator System for SQUID (SQUID 냉각장치용 극저온 시스템 개발)

  • Lee, Kum-Bae;Baek, Il-Hyun
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.18 no.2
    • /
    • pp.121-129
    • /
    • 1989
  • 헬륨을 이용한 극저온 냉동기는 압축기(compressor)을 통하여 압력을 10-20 기압 정도로 높혀준후 여러 단계의 열교환기(heat exchanger)를 통하여 상전위온도(maximum inversion temperature) 이하로 떨어뜨린후 Joule-Thomson 밸브를 통하면 4K까지 온도가 떨어진다. 이때 압력은 1기압 정도이며 헬륨가스는 액체로 변한다. 본 연구의 목적은 Gifford-McMahon 냉동기와 Joule-Thomson 냉동기의 혼합형인 극저온 냉동기를 설계, 제작하여 죠셉슨(Josephson) 소자를 이용한 SQUID(초전도양자 간섭장치), 여러 종류의 탐지기, 컴퓨터 소자 개발 등을 위한 냉동기로 사용하는데 그 목적이 있다. 개발되는 법동기의 용량은 1 W이며, 최저온도는 4K 정도가 된다.

  • PDF

Optimal Design of a 3 Watt GM-JT Refrigeratior at 4 K (4 K, 3 Watt급 GM-JT냉동기의 최적설계)

  • Chang, H.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.1
    • /
    • pp.11-19
    • /
    • 1994
  • An optimal design for Gifford-McMahon/Joule-Thomson(GM-JT) refrigerators was performed by a numerical method. The design goal was to meet the cooling requirement for MRI systems, which was 3 Watt at 4 K. A general cycle analysis program was written to calculate the cooling capacity of the GM-JT refrigerators for the givenstage GM refrigerator. The program was executed for a specific refrigerator with various design parameters. The optimal values for the maximum cooling were found for the sizes of the heat exchangers, the mass flow rate of helium, and the compression pressure.

  • PDF

Miniature J-T Refrigerator Using Triplet Heat Exchanger (Triplet 열교환기를 사용하는 소형 J-T 냉동기)

  • Hwang, G.;Jeong, S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.60-63
    • /
    • 2009
  • Most J-T (Joule-Thomson) refrigerators use a Giaque-Hampson type heat exchanger due to its excellent thermal performance and compactness. The cryoprobe (cryosurgical probe) treating prostate cancer usually has a dimension of 17 gauge (1.6 mm diameter), so it does not have enough space to bear a Giaque-Hampson type heat exchanger. In this paper, the triplet heat exchanger is adopted as the heat exchanger of cryoprobe, and the performance is investigated with an experimental test. The result shows that the triplet heat exchanger can be substituted for Giaque-Hampson type heat exchanger in the application of cryosurgery.

Prediction of liquid amount in hydrogen liquefaction systems using GM refrigerator (GM냉동기를 이용한 수소액화 시스템의 액화량 예측)

  • 박대종;장호명;강병하
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.349-358
    • /
    • 1999
  • Thermodynamic cycle analysis has been performed to maximize the liquid amount for various hydrogen liquefaction systems using GM(Gifford-McMahon) refrigerator. Since the present authors' previous experiments showed that the liquefaction rate was approximately 5.1mg/s in a direct contact with a commercial GM refrigerator, the purpose of this study is to predict how much the liquefaction rate can be increased in different configurations and with improved heat exchanger performance. The optimal operating conditions have been analytically sought with real properties of normal hydrogen for the single-stage GM precooled L-H(Linde-Hampson) system, the two-stage GM direct contact system, the two-stage GM precooled L-H system and the two-stage helium GM-JT (Joule-Thomson) system. The maximum liquefaction rate has been predicted to be only about 7 times greater than the previous experiment, when the two-stage precooling is employed and the effectiveness of heat exchangers approaches to 99.0%. It is concluded that the liquefaction rate is limited mainly by the cooling capacity of the current GM refrigerators and a larger scale of hydrogen liquefaction is possible with a greater capacity of cryocooler at 60-70 K range.

  • PDF

Design and Analysis of Cryogenic Turbo Expander for HTS Power Cable Refrigeration System (초전도 전력 케이블 냉각 시스템 적용을 위한 극저온 터보 팽창기 설계 및 해석)

  • Lee, Changhyeong;Kim, Dongmin;Yang, Hyeongseok;Kim, Seokho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.3
    • /
    • pp.141-148
    • /
    • 2015
  • The cryogenic cooling system should maintain the HTS power cable below 77 K. As the length of HTS power cables has increased, there have been many efforts to develop large capacity cryocoolers. Brayton, Joule-Thomson, and Claude refrigerators were considered for the large capacity cryocooler. Among the various cryocoolers, the Brayton refrigerator is the most competitive in terms of the HTS power cable. At present, it is thought that a 10-kW class refrigerator will be able to be used as a unit cooling system for the commercialization of HTS power cables in the near future. The Brayton refrigerator is composed of recuperative heat exchangers, a compressor, and a cryogenic turbo expander. Among the various components, the cryogenic turbo expander is the part that decreases the temperature, and it is the most significant component that is closely related with overall system efficiency. It rotates at high speed using high-pressure helium or neon gas at cryogenic temperatures. This paper describes the design of a 300-W class Brayton refrigeration cycle and the cryogenic turbo expander as a downscale model for the practical 10-kW class cycle. Flow and structural analyses are performed on the rotating impeller and nozzle to verify the efficiency and the design performance.

Thermodynamic Analysis of Hydrogen Lquefaction Systems Using Gifford-McMahon Cryocooler

  • Chang, Ho-Myung;Park, Dae-Jong;Kang, Byung-Ha
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.8 no.2
    • /
    • pp.39-50
    • /
    • 2000
  • Thermodynamic cycle analysis is presented to estimate the maximum liquefaction rate of hydrogen for various systems using a Gifford-McMahon(GM) cryocooler. Since the present authors` previous experiments showed that the gaseous hydrogen was liquefied approximately at the rate of 5.1 mg/s from the direct contact with a commercial two-stage GM refrigerator, this study has been proposed to predict how much the liquefaction rate can be increased in different configurations using the GM cooler and with improved heat exchangers. The optimal operating conditions have been analytically sought with real properties of normal hydrogen for the Linde-Hampson(L-H) system precooled by single-stage GM, the direct-contact system with two-stage GM, the L-H system precooled by two-stage GM, and the direct-contact system with helium GM-JT (Joule-Thomson). The maximum liquefaction rate has been predicted to be only about 7 times greater than the previous experiment, even though the highly effective heat exchangers may be employed. It is concluded that the liquefaction rate is limited mainly because of the cooling capacity of the commercially available GM cryocoolers and a practical scale of hydrogen liquefaction is possible only if the GM cooler has a greater capacity at 70-100 K.

  • PDF

An Experimental Study of The J-T Cryocooler with Mixed Refrigerant (혼합 냉매를 이용한 극저온 J-T 냉동기 관한 실험적 연구)

  • 이경수;정상권
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.64-68
    • /
    • 2001
  • An experimental study on the Joule-Thomson cryocooler with the mixed refrigerant (MR) is described in this paper, J-T refrigeration experiment was performed with a single stage regular air-conditioning compressor The mixed refrigerant in the experiment was composed of 75% mol fraction of $N_2$. 30% moi fraction of CH$_4$. 30% moi fraction of $C_2$H$_{6}$. 10% mot fraction of $C_3$H$_{8}$ and 15% mot fraction of iso-C$_4$H$_{10}$. Oil mist in the MR stream could be eliminated completely by the glass microfiber filter. Since a single stage compressor that had been designed thor R22 is not appropriate for high Pressure ratio of the mixed refrigerant especially during the transient period. two modifications were incorporated to regular J-T refrigeration cycle. First. a Portion of the MR was by-passed at the inlet of the heat exchanger and transferred directly to 7he suction of the compressor in the modified system. Second, a buffer volume was Prepared to change the mass flow rate of refrigerant. The pressure ratio in J-T expansion device was relieved at the beginning of the operation due to the by-Pass scheme. but it gradually decreased during the transient Process as some of the MR component condensed at low temperature. The buffer volume at the suction side was used to increase the MR gas density in the system after the transient cool-down period. Form the experiment with the modified system, the refrigerator could reach the lowest temperature of -152$^{\circ}C$ without cooling load. and about -15$0^{\circ}C$ with 5 W of cooling load . . . .

  • PDF