• Title/Summary/Keyword: Joint location

Search Result 434, Processing Time 0.023 seconds

Discoid Meniscal Cyst -Report of 3 Cases- (원판형 연골 낭포 - 3예 보고 -)

  • Cho Sung-Do;Ko Sang-Hun;Hwang Soo-Yeon;Lee Ju-Yong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.220-225
    • /
    • 2003
  • The meniscal cyst of knee joint is a rare disease, and the discoid meniscal cyst has not been reported in Korea. We report 3 cases of the discoid meniscal cyst confirmed by MRI and arthroscopy. In physical examination, all cases have tenderness of the knee joint. One has palpable mass of knee joint and the other one has limitation of knee motion with knee flexion contracture of 10 degrees and positive McMurray test at external rotation of the knee. All cases are complete discoid meniscus, which are, one medial discoid meniscus and two lateral discoid meniscus through MRI. We confirmed horizontal tear of meniscus in all cases and the location of meniscal cysts are anterior hem of meniscus in one and body of meniscus in two. We could get excellent results in all 3 cases that return to normal knee range of motion.

  • PDF

Pathophysiology of Stiff Elbow (주관절 강직의 병태 생리)

  • Song, Hyun-Seok;Yoon, Hyung-Moon
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.286-292
    • /
    • 2010
  • Purpose: Stability of joints and maintenance of range of motion are needed for optimum function. The most common complaint about the elbow joint is joint stiffness. Recent articles have reported good outcomes in the treatment of stiff elbow joints. However, deciding which procedure to use is always difficult. Materials and Methods: Morrey et al. reported that the functional range of motion of the elbow joint is $30-130^{\circ}$ of flexion-extension and $50^{\circ}C$ of supination and pronation. About 90% of daily activities are done using this range of motion. Stiff elbow joints can be classified according to the traumatic events that caused the problem or the location of the main pathology. Intraarticular pathology includes severe articular mismatch, intraarticular adhesions, loss of articular cartilage, mechanical blockade by osteophytes, loose bodies, and hypertrophied synovium. Extraarticular pathology includes severe capsular adhesion due to the trauma or to dislocation, contracture of the collateral ligaments or muscles, bony bridge. Results and Conclusions: The main pathology underlying the loss of extension is the fibrous contracture of the anterior capsule. In this pathology, an anterior capsulectomy would be helpful. The main pathology underlying the loss of flexion is the contracture of the posterior band of medial collateral ligament.

Fatigue Analysis based on Kriging for Flaperon Joint of Tilt Rotor Type Aircraft (틸트 로터형 항공기의 플랩퍼론 연결부에 대한 크리깅 기반 피로해석)

  • Park, Young-Chul;Jang, Byoung-Uk;Im, Jong-Bin;Lee, Jung-Jin;Lee, Soo-Yong;Park, Jung-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.6
    • /
    • pp.541-549
    • /
    • 2008
  • The fatigue analysis is performed to avoid structural failure in aerospace structures under repeated loads. In this paper, the fatigue life is estimated for the design of tilt rotor UAV. First of all, the fatigue load spectrum for tilt rotor UAV is generated. Fatigue analysis is done for the flaperon joint which may have FCL(fracture critical location). Tilt rotor UAV operates at two modes: helicopter mode such as taking off and landing; fixed wing mode like cruising. To make overall fatigue load spectrum, FELIX is used for helicopter mode and TWIST is used for fixed wing mode. The other hand, the Kriging meta model is used to get S-N regression curve for whole range of material life when S-N test data are analyzed. And then, the second order of S-N curve is accomplished by the least square method. In addition, the coefficient of determination method is used to ensure how accuracy it has. Finally, the fatigue life of flaperon joint is compared with that obtained by MSC. Fatigue.

Radiographic Study of Cobey Method and Modified Cobey Method (Cobey 검사법과 Modified Cobey 검사법에 대한 방사선학적 연구)

  • Go, Yu-Rim;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.167-173
    • /
    • 2019
  • The Cobey method and the modified Cobey method are most commonly used in clinical practice. Therefore, the purpose of this study was to investigate the radiological differences between Cobey and modified Cobey and provide radiographic information about changes of hindfoot image with X-ray entrance center and tube angle change in modified Cobey. This study was performed on foot and ankle phantom. First, for image comparison of Cobey and modified Cobey, the images obtained by applying the same X-ray entrance center to the ankle joint were compared and analyzed. Second, in the modified Cobey, the X-ray entrance center is set as ankle joint and lateral malleolus. The X-ray tube angle was varied from $10^{\circ}$ to $40^{\circ}$ at $5^{\circ}$ intervals for each X-ray entrance center. The images obtained by varying the X-ray tube angle from $10^{\circ}$ to $40^{\circ}$ at intervals of $5^{\circ}$ for each X-ray entrance center were compared and analyzed. The irradiation conditions were the same with 110 kVp, 200 mA, 10 ms, and 110 cm of source - image receptor distance (SID). Image evaluation was performed by two radiologists. Measurements were made on the lateral point, middle point, and calcaneus width based on a hypothetical line parallel to the calcaneal tuberosity. Data were analyzed by using descriptive statistics as the mean of the distance to each measurement location. The modified Cobey was longer than the Cobey by an average of 3 to 4 mm lateral and medial points, and the calcaneus width was similar (ICC = 0.939). In modified Cobey method, when the X-ray entrance center is ankle joint, the lateral point is about 3 mm and the medial point is about 4.3 mm longer than lateral malleolus. Also, when the X-ray tube angle is more than $20^{\circ}$, the degree of distortion is large. The ICCs for the lateral, medial point, and calcaneus width were 0.998, 0.961, and 0.997, respectively, as the X-ray entrance center and tube angle were changed. There was no significant difference between Modified Cobey and Cobey. Modified Cobey showed no need to compensate the $20^{\circ}$ detector angle of the Cobey. In addition, we suggest that tube angle should be limited within $20^{\circ}$ when modified Cobey is performed.

Design of Parallel Input Pattern and Synchronization Method for Multimodal Interaction (멀티모달 인터랙션을 위한 사용자 병렬 모달리티 입력방식 및 입력 동기화 방법 설계)

  • Im, Mi-Jeong;Park, Beom
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.135-146
    • /
    • 2006
  • Multimodal interfaces are recognition-based technologies that interpret and encode hand gestures, eye-gaze, movement pattern, speech, physical location and other natural human behaviors. Modality is the type of communication channel used for interaction. It also covers the way an idea is expressed or perceived, or the manner in which an action is performed. Multimodal Interfaces are the technologies that constitute multimodal interaction processes which occur consciously or unconsciously while communicating between human and computer. So input/output forms of multimodal interfaces assume different aspects from existing ones. Moreover, different people show different cognitive styles and individual preferences play a role in the selection of one input mode over another. Therefore to develop an effective design of multimodal user interfaces, input/output structure need to be formulated through the research of human cognition. This paper analyzes the characteristics of each human modality and suggests combination types of modalities, dual-coding for formulating multimodal interaction. Then it designs multimodal language and input synchronization method according to the granularity of input synchronization. To effectively guide the development of next-generation multimodal interfaces, substantially cognitive modeling will be needed to understand the temporal and semantic relations between different modalities, their joint functionality, and their overall potential for supporting computation in different forms. This paper is expected that it can show multimodal interface designers how to organize and integrate human input modalities while interacting with multimodal interfaces.

LSTM Network with Tracking Association for Multi-Object Tracking

  • Farhodov, Xurshedjon;Moon, Kwang-Seok;Lee, Suk-Hwan;Kwon, Ki-Ryong
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.10
    • /
    • pp.1236-1249
    • /
    • 2020
  • In a most recent object tracking research work, applying Convolutional Neural Network and Recurrent Neural Network-based strategies become relevant for resolving the noticeable challenges in it, like, occlusion, motion, object, and camera viewpoint variations, changing several targets, lighting variations. In this paper, the LSTM Network-based Tracking association method has proposed where the technique capable of real-time multi-object tracking by creating one of the useful LSTM networks that associated with tracking, which supports the long term tracking along with solving challenges. The LSTM network is a different neural network defined in Keras as a sequence of layers, where the Sequential classes would be a container for these layers. This purposing network structure builds with the integration of tracking association on Keras neural-network library. The tracking process has been associated with the LSTM Network feature learning output and obtained outstanding real-time detection and tracking performance. In this work, the main focus was learning trackable objects locations, appearance, and motion details, then predicting the feature location of objects on boxes according to their initial position. The performance of the joint object tracking system has shown that the LSTM network is more powerful and capable of working on a real-time multi-object tracking process.

A Kidnapping Detection Using Human Pose Estimation in Intelligent Video Surveillance Systems

  • Park, Ju Hyun;Song, KwangHo;Kim, Yoo-Sung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.8
    • /
    • pp.9-16
    • /
    • 2018
  • In this paper, a kidnapping detection scheme in which human pose estimation is used to classify accurately between kidnapping cases and normal ones is proposed. To estimate human poses from input video, human's 10 joint information is extracted by OpenPose library. In addition to the features which are used in the previous study to represent the size change rates and the regularities of human activities, the human pose estimation features which are computed from the location of detected human's joints are used as the features to distinguish kidnapping situations from the normal accompanying ones. A frame-based kidnapping detection scheme is generated according to the selection of J48 decision tree model from the comparison of several representative classification models. When a video has more frames of kidnapping situation than the threshold ratio after two people meet in the video, the proposed scheme detects and notifies the occurrence of kidnapping event. To check the feasibility of the proposed scheme, the detection accuracy of our newly proposed scheme is compared with that of the previous scheme. According to the experiment results, the proposed scheme could detect kidnapping situations more 4.73% correctly than the previous scheme.

Detection of Second-Layer Corrosion in Aging Aircraft

  • Kim, Noh-Yu;Yang, Seun-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.6
    • /
    • pp.591-602
    • /
    • 2009
  • The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented for quantitative characterization of exfoliative corrosion through deconvolution procedure using a nonlinear least-square error minimization method. It produces practical information such as location and width of planar corrosion in layered structures of aircraft, which generally cannot be detected by conventional NDE techniques such as the ultrasonic method.

STRESS ANALYSIS OF ROOT AND SUPPORTING TISSUES BY VARIOUS POST CORE DESIGN (지대치 형태에 따른 Post core의 치근내부 및 지지조직의 응력분석)

  • Kim Jin;Vang Mong-Sook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.468-481
    • /
    • 1993
  • The Purpose of this study was to analyze the stresses and displacements of various post and core. The Finite element models of central incisors were divided into seven types according to the various amount of remaining tooth structures. $10kgf/mm^2$ force was applied respectively as follows : 1) Horizontal on the labial surface 2) $26^{\circ}$ diagonal direction on the lingual surface. Material property, geometry, and load condition of each model were inputted to the two dimensional ANSYS 4.4A finite element program : stresses and displacements were analyzed. Results were follows : 1. In the case of $130^{\circ}$ shoulder post and core, Maximum tensile and shear stresses were observed in the crown margin. 2. Maximum shear stress was about 29% reduced by contrabevel. 3. In the case of 1mm axial tooth structure, Maximum tensile stress observed in the dentin. 4. In the case of but joint of cervix, Maximum stress concentration was observed in the dentin by the inclined and horizontal force. 5. Horizontal force produced the extraordinary high stresses in dentin and supporting structures. 6. The amount of remaining tooth structure affected the level of stress significantly and it determined the location of stress concentration.

  • PDF

Assessment of Tunnel Displacement with Weak Zone Orientation using 3-D Numerical Analysis (3차원 수치해석을 이용한 연약대 방향에 따른 터널 거동 특성 평가)

  • Yim, Sung-Bin;Jeong, Hae-Geun;Seo, Yong-Seok
    • The Journal of Engineering Geology
    • /
    • v.19 no.1
    • /
    • pp.43-50
    • /
    • 2009
  • A 3-D numerical analysis was carried out to observe potential effects of orientation of inherent weak zones to tunnel behaviors and stress distributions during tunnel excavation. Weak zones used for the analysis were placed at the upper 1D part from crown, on the crown and on the center of face, using orientations derived from the 6th RMR parameter for assessment of joint orientation effect on tunnel. Mechanical properties of rock mass were derived through a in-situ displacement measurement-based back analysis. Finally, a classification chart for crown settlement with five ranks based on orientation and location of weak zones is suggested.