• Title/Summary/Keyword: Johnson Model

Search Result 154, Processing Time 0.021 seconds

Metal Matrix Composite(MMC) Layered Armour System (금속복합판재 적용 다층 구조 방호성능 평가)

  • Lee, Minhyung;Park, Sang-Won;Jo, Ilguk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.6
    • /
    • pp.752-757
    • /
    • 2017
  • Analysis has been performed for the penetration of a long-rod into MMC/Ceramic layered armour system with several shot test and a series of simulations. Two types of MMC plate have been fabricated by a liquid pressing method; A356/45%vol.%SiCp with a uniform distribution of SiC particle and Al7075/45%vol.B4Cp with B4C particle. The mechanical properties were measured with the high-speed split Hopkins bar test, hardness test and compression test. The popular Simplified Johnson-Cook model was adopted to represent the material characteristics for FEM simulations. The performance of the MMC applied armour system has been made by comparing with the semi-infinite mild steel target using the depth of penetration(DOP). The results show that placing ceramic front layer provides a certain gain in protection, and that placing another ductile front layer provides a further gain. The application of MMC is found to be attractive.

Homogenization of Plastic Behavior of Metallic Particle/Epoxy Composite Adhesive for Cold Spray Deposition (저온 분사 공정을 위한 금속입자/에폭시 복합재료 접착제의 소성 거동의 균질화 기법 연구)

  • Yong-Jun Cho;Jae-An Jeon;Kinal Kim;Po-Lun Feng;Steven Nutt;Sang-Eui Lee
    • Composites Research
    • /
    • v.36 no.3
    • /
    • pp.199-204
    • /
    • 2023
  • A combination of a metallic mesh and an adhesive layer of metallic particle/epoxy composite was introduced as an intermediate layer to enhance the adhesion between cold-sprayed particles and fiber-reinforced composites (FRCs). Aluminum was considered for both the metallic particles in the adhesive and the metallic mesh. To predict the mechanical characteristics of the intermediate bond layer under a high strain rate, the properties of the adhesive layer needed to be calculated or measured. Therefore, in this study, the Al particle/epoxy adhesive was homogenized by using a rule of mixture. To verify the homogenization, the penetration depth, and the thickness decrease after the cold spray deposition from the undeformed surface, was monitored with FE analysis and compared with experimental observation. The comparison displayed that the penetration depth was comparable to the diameters of one cold spray particle, and thus the homogenization approach can be reasonable for the prediction of the stress level of particulate polymer composite interlayer under a high strain rate for cold spray processing.

Kinematic Analysis of Airborne Movement of Dismount from High Bar(I) (철봉 내리기 공중 동작의 운동학적 분석(I))

  • Choi, Ji-Young;Kim, Youg-Ee;Jin, Young-Wan
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.159-177
    • /
    • 2002
  • The purpose of this study was to investigate the relations between the segments of the body, the three dimensional anatomical angle and the angular velocity of the air born phase and understand the control mechanism of the high-bar movement, the somersault, the double somersault, the double somersault with full twist. For this study seven well trained university gymnastic volunteered, Zatsiorky and Seluyanov(1983, 1985)'s sixteen segment system anatomical model was used for this study. For the movement analysis three dimensional cinematographical method(Arial Performance Analysis System : APAS) was used and for the calculation of the kinematic variables a self developed program was used with the LabVIEW 5.1 graphical profromming(Johnson, 1999) program. By using Eular's equations the three dimensional anatomical Cardan angles of the joint and angular velocity were defined. As a result of this study 1. As the rotation of the body increased in the air born phase the projection angle of the CM of the total increased, this resulted the increased of the max hight of the CM. 2. In three dimensional angular velocity the Z axis(vertical direction) projection angular velocity increased as the rotation of the body increased in the airborn phase, but the Y axis and the X axis projection angular velocity did not show significant differences. 3. As the rotation of the body increased in the air born phase the angular movement of the shoulder and the hip showed significant change. These movement act as the starter in the preparation phase. 4. The somersault angle, the twist angle, the tilt angle of the upper body related to the global reference frame in the releas phase the average somersault angle of the three types of high-bar movement was $57.7^{\circ}$, $38.8^{\circ}$, $39.7^{\circ}$, the average tilt angle was $-1.5^{\circ}$, $-5.4^{\circ}$, $-8.4^{\circ}$, the average twist angle was $13.4^{\circ}$, $10.6^{\circ}$, $23.3^{\circ}$. This result showed that the somersault with full twist had the largest movement.

Effects of Head-Down Tilt$(-6^{\circ})$ on Hemodynamics and Plasma Catecholamine Levels (도립$(-6^{\circ})$이 혈장 Catecholamine 및 심장혈관계에 미치는 영향)

  • Song, Dae-Kyu;Bae, Jae-Hoon;Park, Won-Kyun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.21 no.2
    • /
    • pp.211-223
    • /
    • 1987
  • Head-down tilt (HDT) at $-6^{\circ}$ has been commonly used as the experimental model in both man and animals to induce the blood shift toward the head or central protion of the body, demonstrating similar physiological effect encountered in the weightlessness in the orbital flight. There are few reports about the physiological response upon the cardiovascular regulatory system or the tolerance to the $(-6^{\circ})$ HDT within a relatively short period less than 1 hour. Therefore, the purpose of this study way to observe the effects of $-6^{\circ}$ HDT on cardiovascular system within 30 minutes and to evaluate early regulatory mechanism for simulated hypogravity. Ten mongrel dogs weighing 8-12 kg were anesthetized with the infusion of 1% ${\alpha}-chloralose$ (100 mg/kg) intravenously, and the postural changes were performed from the supine to the $-6^{\circ}$ head-down Position, then from the head-down to the supine (SUP), and each posture was maintained for 30 minutes. Blood flow $({\dot{Q}})$ through common carotid and femoral arteries were determined by the electromagnetic flowmeter. Mean arterial pressure (MAP), heart rate (HR), respiratory rate , and pH, $P_{O_2}$, $P_{CO_2}$ and hematocrit (Hct) of arterial and venous blood were also measured. The peripheral vascular resistance was calculated by dividing respective MAP values by ${\dot{Q}}$ through both sides of common carotid or femoral arteries. The concentration of plasma epinephrine and norepinephrine was determined by Peuler & Johnson's radioenzymatic method. The results are summarized as follows: In the initial 5 minutes in $-6^{\circ}$ HDT, HR was significantly (p<0.05) increased and MAP slightly decreased. Although ${\dot{Q}}$ and carotid peripheral artery resistance were not significantly changed, ${\dot{Q}}$ through femoral artery was diminished and femoral peripheral artery resistance was elevated. In the SUP, the initial changes of MAP and HR were increased (p<0.05), but those of ${\dot{Q}}$ and peripheral vascular resistance through both common carotid and femoral arteries were not significant. After 10 minutes of each postural change in both HDT and SUP, MAP was maintained almost equal to that of the level of pretilting control. During 60 minutes of both postural changes of HDT and SUP, $P_{O_2}$ and Hct were not changed significantly. However pH tended to increase slowly and $P_{CO_2}$ was gradually decreased. The pH and $P_{CO_2}$ seemed to be related to the increased respiratory rate. Plasma epinephrine concentration was not changed significantly and plasma norepinephrine concentration was slightly decreased in the course of HDT and also at 10 minutes of SUP. However these concentration changes were statistically insignificant. From these results, it may be concluded that the effect of $-6^{\circ}$ HDT for 30 minutes on the cardiovascular system and plasma catecholamine levels of the dog is minimum and it is suggestive that the cardiovascular regulatory mechanism, possibly mediated by so called gravity receptors including baroreceptor and volume receptor, has been properly and adequately operated.

  • PDF