• Title/Summary/Keyword: Jet length

Search Result 357, Processing Time 0.023 seconds

Reproductive Performance of Crossbred and Indigenous (Desi) Dairy Cows under Rural Context at Sirajgonj District of Bangladesh

  • Paul, Ashit Kumar;Al-Maruf, Abdullah;Jha, Pankaj Kumar;Alam, M. Golam Shahi
    • Journal of Embryo Transfer
    • /
    • v.28 no.4
    • /
    • pp.319-324
    • /
    • 2013
  • This study was conducted among 120 different breed cows at selected areas of Sirajgonj district from March to July 2010 to compare the reproductive performance of crossbred and Desi cows at farmer's level. The results showed that the average daily milk yield of Desi, Shahiwal ${\times}$ Desi, Friesian ${\times}$ Desi and Jersey ${\times}$ Desi cows was $2.3{\pm}0.2$, $4.9{\pm}0.9$, $6.0{\pm}1.0$ and $5.7{\pm}0.9$ liters, respectively. The milk yield of crossbred cows ($5.5{\pm}0.6$ liters/day) was significantly (p<0.01) higher than Desi cows ($2.3{\pm}0.2$ liters/day). The average age at puberty of Shahiwal ${\times}$ Desi, Friesian ${\times}$ Desi and Jersey ${\times}$ Desi was significantly (p<0.01) lower than that of Desi breed. The crossbred cows had significantly (p<0.01) lower pubertal age ($20.4{\pm}1.2$) than Desi ($25.9{\pm}1.1$). The age at first calving in Desi cows was significantly (p<0.01) higher ($37.6{\pm}1.1$ months) than crossbred cows ($31.2{\pm}1.3$ months). The average gestation length of Desi, Shahiwal ${\times}$ Desi, Friesian ${\times}$ Desi and Jersey ${\times}$ Desi was $289.9{\pm}1.4$, $285.0{\pm}0.0$, $285.0{\pm}4.2$ and $282.1{\pm}2.4$ days, respectively. It is suggested that the overall reproductive performance of Friesian ${\times}$ Desi, Jersey ${\times}$ Desi and Shahiwal ${\times}$ Desi cows were better than that of Desi cow.

Characteristics of Multi staged Combustion on a Double-cone Partial Premixed Nozzle (이중 콘형 부분 예혼합 GT 노즐의 다단 연소특성)

  • Kim, Han Seok;Cho, Ju Hyeong;Kim, Min Kuk;Hwang, Jeongjae;Lee, Won June
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.1
    • /
    • pp.49-55
    • /
    • 2020
  • Experimental investigations were conducted to understand the multi-staged combustion characteristics of a swirl-stabilized double cone premixed burner nozzle used for industrial gas turbines for power generation. Multi-staged combustion is implemented by injecting the fuel through the existing manifold of the side slots as well as through the apex of the cone with two fuel injection angles which are slanted or axial. NOx and CO emissions, and wall temperature distributions were measured for various fuel distributions and operating conditions. Results show that NOx emissions are decreased when the fuel distribution to the apex is 3% of the total amount of fuel, which is due to more uniform fuel distribution inside the nozzle, hence less hot spots at the flame. NOx emissions are rather increased when the fuel distribution to the apex is 8% of the total amount of fuel for axial fuel injection by occurrence of flash back in premixing zone of burner.

Combustion Characteristics of a Double-cone Partial Premixed Nozzle with Various Fuel hole Patterns (이중 콘형 부분 예혼합 GT 노즐의 연료 분사구 형상 변화에 대한 연소특성)

  • Kim, Han Seok;Cho, Ju Hyeong;Kim, Min Kuk;Hwang, Jeongjae;Lee, Won June
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.25-31
    • /
    • 2020
  • Experimental investigations were conducted to examine the combustion characteristics of a swirl-stabilized double cone premixed burner nozzle used for industrial gas turbines for power generation. Several variants with different fuel injection patterns are tested to compare the combustion characteristics such as NOx and CO emissions, stability, and wall temperature distributions. Main results show that NOx emissions and stability are decreased either when the fuel hole diameter is decreased with the same number of fuel holes, or when the number of fuel holes is reduced with the same total area of fuel holes, both of which are due to a higher penetration of fuel into the air stream. Not only is NOx reduced but also stability is enhanced when the fuel hole diameter varies in an alternating manner with the same total area of fuel holes, showing that NOx reduction is due to a higher penetration of mean fuel injection path while stability enhancement is due to a lowered penetration of minimum fuel injection path.

Patterns of Ovarian Changes Associated with Surge Mode Secretion of Gonadotropin in Dairy Cows with Cyclic Estrous Cycle

  • Kim, Seung-Joon
    • Journal of Embryo Transfer
    • /
    • v.33 no.4
    • /
    • pp.297-304
    • /
    • 2018
  • The purpose of the present study was to determine the elaborate characteristics of ovarian changes including follicles and corpus luteum, and hormonal patterns of gonadotropin surge mode secretions during the normal consecutive estrous cycle in three dairy cows. Non-lactating and multiparous Holstein cows (n=3) used as experimental animals. The cows were assigned to examine the relationship among ovarian changes (follicle, corpus luteum), ovarian steroids (estradiol, progesterone) and gonadotropin (LH, FSH) surge mode secretion during the successive estrous cycles by rectal palpation, ultrasonography and hormonal assay. The mean length of the estrous cycle for the three cows was $23.1{\pm}1.44days$ (${\pm}SEM$), with a range of 20-28 days. In six estrous cycles, the number of two follicular waves, three follicular waves and four follicular waves was 2, 3 and 1, respectively. The sequential ultrasonographic monitoring showed that the corpus luteum with ${\geq}10mm$ in diameter detected from Day 2 (Day 0 is ovulation) in six estrous cycles of all cows. Preovulatory increases in estradiol concentration reached $10.36{\pm}1.10pg/ml$ on the 2 days before ovulation of the last dominant follicle. All cows exhibited a preovulatory rise in estradiol concentration followed by a typical preovulatory LH and FSH surge. The mean interval from the peak of LH/FSH surge to ovulation of the last dominant follicle was $31.3{\pm}1.76h$ (${\pm}SEM$). In these results, each dairy cow showed that ovarian morphological changes and gonadotropin surge mode secretion will be regulated by various environmental factors including age, breeds, nutrition, breeding conditions, etc.

Investigation of three-dimensional deformation mechanisms of box culvert due to adjacent deep basement excavation in clays

  • Bu, Fanmin;Yu, Wenrui;Chen, Li;Wu, Erlu
    • Geomechanics and Engineering
    • /
    • v.30 no.6
    • /
    • pp.565-577
    • /
    • 2022
  • In this study, a series of three-dimensional numerical parametric study was conducted to investigate deformation mechanisms of an existing box culvert due to an adjacent multi-propped basement excavation in clays. Field measurements from an excavation case history are first used to calibrate a baseline Hardening Soil Small Strain (HS-small) model, which is subsequently adopted for parametric study. Results indicate that the basement-box culvert interaction along the basement centerline can be considered as a plane strain condition when the length of excavation (L) reaches 14 He (i.e., final excavation depth). If a plane strain condition (i.e., L/He=12.0) is assumed for analyzing the basement-box culvert interaction of a short excavation (i.e., L/He=2.0), the maximum settlement and horizontal movement of the box culvert are overestimated significantly by up to 15.7 and 5.1 times, respectively. It is also found that the deformation of box culvert can be greatly affected by the basement excavation if the distance between the box culvert and retaining wall is less than 1.5 He. The induced deformation in the box culvert can be dramatically reduced by improving the ground inside the excavation or implementing other precautionary measures. For example, by adding jet grouting columns within the basement and installing an isolation wall behind the retaining structures, the maximum settlements of box culvert are shown to reduce by 37.2% and 13.4%, respectively.

Study of hydrodynamics and iodine removal by self-priming venturi scrubber

  • Jawaria Ahad;Talha Rizwan ;Amjad Farooq ;Khalid Waheed ;Masroor Ahmad ;Kamran Rasheed Qureshi ;Waseem Siddique ;Naseem Irfan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.169-179
    • /
    • 2023
  • Filtered containment system is a passive safety system that controls the over-pressurization of containment in case of a design-based accidents by venting high pressure gaseous mixture, consisting of air, steam and radioactive particulate and gases like iodine, via a scrubbing system. An indigenous lab scale facility was developed for research on iodine removal by venturi scrubber by simulating the accidental scenario. A mixture of 0.2 % sodium thiosulphate and 0.5 % sodium hydroxide, was used in scrubbing column. A modified mathematical model was presented for iodine removal in venturi scrubber. Improvement in model was made by addition of important parameters like jet penetration length, bubble rise velocity and gas holdup which were not considered previously. Experiments were performed by varying hydrodynamic parameters like liquid level height and gas flow rates to see their effect on removal efficiency of iodine. Gas holdup was also measured for various liquid level heights and gas flowrates. Removal efficiency increased with increase in liquid level height and gas flowrate up to an optimum point beyond that efficiency was decreased. Experimental results of removal efficiency were compared with the predicted results, and they were found to be in good agreement. Maximum removal efficiency of 99.8% was obtained.

Rationale and criteria for excellent finishing (양호한 Finishing을 위한 이론적 근거 및 기준)

  • Ryu, Young-Kyu;Kim, Young-Joon
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.637-648
    • /
    • 1999
  • Finishing is usually accomplished about four to seven months before the removal of orthodontic appliance in order to achieve ideal occlusion and excellent aesthetics. This process, called finishing, is the key to obtain excellent final results. Some of orthodontists believe it can be accomplished at the final stage of orthodontic treatment, and they complete it without their special rationale and criteria for finishing. However, it should be considered as a part of the total treatment plan from the beginning to end, and a guideline for finishing, which is based on rationale and criteria for the removal of orthodontic appliance, is needed to obtain the desired results. The guideline should include a checklist for finishing. This checklist is divided into four categories: occlusal, aesthetic, periodontal, and habitual factors. Occlusal fators include alignment, marginal ridge discrepancy, interproximal contact, anterior inclination, posterior inclination, over-jet over-bite, arch fen and functional occlusion. Aesthetic factors include gingival form, crown fen crown width, and crown length. Periodontal factors include root angulation, bone level, and black hole in periodontal factors. Habitual factors consist of mouth breathing, tongue position at rest, tongue thrust, lip biting, nail biting, and finger sucking

  • PDF

Experimental Study of Flip-Bucket Type Hydraulic Energy Dissipator on Steep slope Channel (긴구배수로 감세공의 Filp Bucket형 이용연구)

  • 김영배
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.1
    • /
    • pp.2206-2217
    • /
    • 1971
  • Spillway and discharge channel of reservoirs require the Control of Large volume of water under high pressure. The energies at the downstream end of spillway or discharge channel are tremendous. Therefore, Some means of expending the energy of the high-velocity flow is required to prevent scour of the riverbed, minimize erosion, and prevent undermining structures or dam it self. This may be accomplished by Constructing an energy dissipator at the downstream end of spillway or discharge channel disigned to dissipated the excessive energy and establish safe flow Condition in the outlet channel. There are many types of energy dissipators, stilling basins are the most familar energy dissipator. In the stilling basin, most energies are dissipated by hydraulic jump. stilling basins have some length to cover hydraulic jump length. So stilling basins require much concrete works and high construction cost. Flip bucket type energy dissipators require less construction cost. If the streambed is composed of firm rock and it is certain that the scour will not progress upstream to the extent that the safety of the structure might be endangered, flip backet type energy dissipators are the most recommendable one. Following items are tested and studied with bucket radius, $R=7h_2$,(medium of $4h_2{\geqq}R{\geqq}10h_2$). 1. Allowable upstream channel slop of bucket. 2. Adequate bucket lip angle for good performance of flip bucket. Also followings are reviwed. 1. Scour by jet flow. 2. Negative pressure distribution and air movement below nappe flow. From the test and study, following results were obtained. 1. Upstream channel slope of bucket (S=H/L) should be 0.25<H/L<0.75 for good performance of flip bucket. 2. Adequated lip angle $30^{\circ}{\sim}40^{\circ}$ are more reliable than $20^{\circ}{\sim}30^{\circ}$ for the safety of structures.

  • PDF

EVALUATION OF CONDYLAR POSITION USING COMPUTED TOMOGRAPH FOLLOWING BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMY (전산화단층촬영법을 이용한 하악 전돌증 환자의 하악지 시상 골절단술후 하악과두 위치변화 분석)

  • Chol, Kang-Young;Lee, Sang-Han
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.570-593
    • /
    • 1996
  • This study was intended to perform the influence of condyle positional change after surgical correction of skeletal Class III malocclusion after BSSRO in 20 patients(males 9, females 11) using computed tomogram that were taken in centric occlusion before, immediate, and long term after surgery and lateral cephalogram that were taken in centric occlusion before, 7 days within the period intermaxillary fixation, 24hour after removing intermaxillary fixation and long term after surgery. 1. Mean intercondylar distance was $84.45{\pm}4.01mm$ and horizontal long axis of condylar angle was $11.89{\pm}5.19^{\circ}$on right, $11.65{\pm}2.09^{\circ}$on left side and condylar lateral poles were located about 12mm and medial poles about 7mm from reference line(AA') on the axial tomograph. Mean intercondylar distance was $84.43{\pm}3.96mm$ and vertical axis angle of condylar angle was $78.72{\pm}3.43^{\circ}$on right, $78.09{\pm}6.12^{\circ}$on left. 2. No statistical significance was found on the condylar change(T2C-T1C) but it had definitive increasing tendency. There was significant decreasing of the distance between both condylar pole and the AA'(p<0.05) during the long term(TLC-T2C). 3. On the lateral cephalogram, no statistical significance was found between immediate after surgery and 24 hours after the removing of intermaxillary fixation but only the lower incisor tip moved forward about 0.33mm(p<0.05). Considering individual relapse rate, mean relapse rate was 1.2% on L1, 5.0% on B, 2.0% on Pog, 9.1% on Gn, 10.3% on Me(p<0.05). 4. There was statistical significance on the influence of the mandibular set-back to the total mandibular relapse(p<0.05). 5. There was no statistical significance on the influence of the mandibular set-back(T2-T1) to the condylar change(T2C-T1C), the condylar change(T2C-T1C, TLC-T2C) to the mandibular total relapse, the pre-operative condylar position to the condylar change(T2C-T1C, TLC-T2C), the pre-operative mandibular posture to the condylar change(T2C-T1C, TLC-T2C)(p>0.05). 6. The result of multiple regression analysis on the influence of the pre-operative condylar position to the total mandibular relapse revealed that the more increasing of intercondylar distance and condylar vertical axis angle and decreasing of condyalr head long axis angle, the more increasing of mandibular horizontal relapse(L1,B,Pog,Gn,Me) on the right side condyle. The same result was founded in the case of horizontal relapse(L1,Me) on the left side condyle.(p<0.05). 7. The result of multiple regression analysis on the influence of the pre-operative condylar position to the pre-operative mandibular posture revealed that the more increasing of intercondylar distance and condylar vertical axis angle and decreasing of condylar head long axis angle, the more increasing of mandibular vertical length on the right side condyle. and increasing of vertical lengh & prognathism on the left side condyle(p<0.05). 8. The result of simple regression analysis on the influence of the pre-operative mandibular posture to the mandibular total relapse revealed that the more increasing of prognathism, the more increasing of mandibular total relapse in B and the more increasing of over-jet the more increasing of mandibular total relapse(p<0.05). Consequently, surgical mandibular repositioning was not significantly influenced to the change of condylar position with condylar reposition method.

  • PDF

CPFD Simulation of Bubble Flow in a Bubbling Fluidized Bed with Shroud Nozzle Distributor and Vertical Internal (CPFD 시뮬레이션을 통한 Shroud 노즐 및 수직 구조물이 설치된 기포 유동층 반응기 내에서의 기포 흐름 해석)

  • Lim, Jong Hun;Bae, Keon;Shin, Jea Ho;Lee, Dong Ho;Han, Joo Hee;Lee, Dong Hyun
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.678-686
    • /
    • 2016
  • The effect of internal and shroud nozzle distributor to bubbling fluidized beds which has the size of $0.3m-ID{\times}2.4m-high$ column was modeled by CPFD (Computational Particle-Fluid Dynamics). Metal-grade silicon particles (MG-Si) were used as bed materials which have $d_p=149{\mu}m$, ${\rho}_p=2,325kg/m^3$ and $U_{mf}=0.02m/s$. Total bed inventory and static bed height were 75 kg and 0.8 m, respectively. Effect of vertical internal on the bubble rising velocity was investigated. Bubbles were split by internal when the axial position of the internal from the distributor, z = 0.45 m. Bed pressure drop and axial solid holdup were not affected by internal. However, in the case that axial distance of internal from distributor was too close to jet penetration length, bubbles were not separated and bypassed internal, and faster than without internal or z = 0.45 m.