• Title/Summary/Keyword: Jeol

Search Result 138, Processing Time 0.026 seconds

A Freeze-fracture Study on the Odontoblast of Dental Pulp in the Rat Incisor (흰쥐 절치치수의 Odontoblast에 관한 Freeze-Fracture 연구)

  • Kim, Myung-Kook
    • Applied Microscopy
    • /
    • v.16 no.2
    • /
    • pp.1-13
    • /
    • 1986
  • The purpose of this study was to investigate the morphology and intercellular junctions of the odontoblast of dental pulp in the rat incisor by means of the freeze fracture electron microscopy. Twenty male Sprague-Dawley rats weighing $150{\sim}200g$ were used. After being anesthetized by an intraperitoneal injection of 0.5 ml sodium pentobarbital per kg in body weight(60 mg/ml) the animals were perfused with 2.5% glutaraldehyde-2% paraformaldehyde fixative in 0.1 M cacodylate buffer, pH 7.2 through the ascending aorta for one hour. The incisors were carefully extracted from the jaws and demineralized by suspending them in 0.1 M EDTA in 3% glutaraldehyde (pH 7.2) for two weeks. After demineralization, the specimens were obtained from the portion divided into five equal parts. For freeze-fracture replication, demineralized tissues were infiltrated for several hours with 10%, 25% glycerol in 0.1M cacodylate buffer as a cryoprotectant and then frozen in liquid Freon 22 and stored in liquid nitrogen. Fracturing and replication were done in Balzers BAF 400D high-vacuum freeze-fracture apparatus at $-120^{\circ}C$ under routine $5X10^{-7}$ Torr vacuum. The tissue was immediately replicated with platinum unidirectionally at $45^{\circ}$ angle and reinforced with carbon at $90^{\circ}$ angle unidirectionally or by using a rotary stage. The replication process was monitored by a quartz-crystal device. The replicas were immersed in 100% methanol overnight. The tissue was then digested from the replica by clorox (laundry bleach), placed into 5% EDTA, and washed repeatedly with distilled water. The replicas were picked up on 0.3% formvar-coated 75 mesh grids and examined in the JEOL 100B electron microscope. The results were as follows; 1. Both in thin sections and freeze-fracture replicas, three types of intercellular junctions were recognizable in the plasma membrane of odontoblast: gap junction, tight junction and desmosome-like junction. 2. The nuclear pores were evenly distributed over the nuclear envelope. The pore complex formed a ring about 70 nm in diameter. 3. Gap junctions were found between odontoblasts as well as odontoblasts and neighbouring pulp cells (fibroblast, subodontoblastic cell process, nerve-like fibre). Gap junctions, which were round, ellipsoid and pear-shaped and 600 nm in diameter, were observed in the odontoblast. 4. Numerous round and ellipsoid gap junctions could be frequently seen on the plasma membranes in cell body and apical part of the odontoblasts. On the P face, the junctions were recognized as a cluster of closely packed particles, measuring about 9 nm in diameter, and on the E face, the junctions were recognized as a shallow grooves.

  • PDF

A COMPARATIVE STUDY ON THE SHEAR BOND STRENGTH OF DICOR AND G-CERA PORCELAIN LAMINATE VENEER (DICOR와 G-CERA PORCELAIN LAMINATE VENEER의 전단결합강도에 관한 비교연구)

  • Cho Mi-Sook;Yang Jae-Ho;Lee Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.33-41
    • /
    • 1991
  • Cermic has been widely used because of its excellent esthetics and strength. The recently introduced castable ceramic system is regarded as the more esthetic and biocompatible restorative material. The purpose of this study was to compare the shear bond strength of Dicer & G-Cera porcelain laminate veneer according to the type of cement and surface treatment and to observe the surface of bonding failure with SEM. Total forty disks(3.5mm $diam.\times2.0mm$ thickness) were prepared. Forty extracted human maxillary central incisor teeth were stored in saline solution. Ten teeth were bonded to Dicer specimen with Dicer ZPC cement and ten teeth were bonded with Dicer resin cement. Ten silicoated G-Cera specimen and ten non-silicoated G-Cera specimen were bonded to teeth with G-Cera resin cement. Bonded units were mounted in a plastic tube with hard stone and stored in a humidor at $37^{\circ}C$ for 24 hours. Shear bond strength was measured by Instron Universal Testing Machine (Model 1125) and all the specimen were observed with SEM(JEOL, JSM-T2000)and modes of failure were recorded. The obtained results were as follows: 1. The mean shear bond strength of Dicer bonded with Dicer resin cement was 11.62 MPa and that bonded with Dicor ZPC cement was 0.88 MPa : Shear bond strength of Dicer bonded with Dicer resin cement was significantly increased(P<0.05). 2. The mean shear bond strength of silicoated G-Cera was 13.10 MPa and that of non silicoated G-Cera was 10.93 MPa : Shear bond strength of silicoated G-Cera was not significantly increased (P>0.05). 3. Shear bond strength of Dicer and G-Cera porcelain laminate veneer was not significantly different (P>0.05). 4. In observation of bond failure with SEM, Dicer bonded with Dicer ZPC cement exhibited adhesive failure. Dicer bonded with Dicer resin cement and silicoated and non silicoated G-Cera exhibited cohesive failure.

  • PDF

AN EXPERIMENTAL STUDY ON THE SHEAR BOND STRENGTHS OF COMPOSITE RESIN TO AIR-ABRADED ENAMEL AND DENTIN (표면처리방법에 따른 복합레진의 결합강도에 관한 실험적 연구)

  • Shin, Jae-Ho;Jang, Ki-Taeg;Hahn, Se-Hyun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.112-124
    • /
    • 1997
  • According to extensive use of composite resin which have superior esthetic property, every effort on improving bonding strength between a tooth and composite resin has been continued. Acid etching technique is a method that micro-etches the tooth surface which provides bonding with composite resin possible. Recently, there were several reports that mechanical treatment obtained from air-abrasion can provide similar bonding strength with acid etching technique. So, this experimental study was designed to compare the shear bonding strength between using air-abrasion technique and using acid etching technique. Initially, bovine teeth were divided into enamel and dentin experimental groups. Respectively each group was categorized into three subgroups. One subgroup was acid etched with 35% phosphoric acid, then bonded with composite resin. The other subgroup was air-abraded with $50{\mu}m$ $Al_2O_3$ particles sprayed with 160psi air pressure using air abrasion unit(KCP-1000, A.D.T., U.SA), and composite resin was bonded. In another subgroup, composite resin was bonded after acid etching following air-abrasion. So, enamel experimental groups were made of E1 (acid etched only), E2(air-abraded only), E3(acid etched following air-abraded), and dentin experimental groups were made of D1(acid etched only), D2(air-abraded only), D3(acid etched following air-abraded). Each subgroup had 10 specimens. Dentin bonding system(Scotchbond Multi-purpose, 3M Co., U.S.A.) and composite resin(Z-100, 3M Co., U.S.A.) were applied on treated surface using 5mm diameter gelatin capsule as manufacturer's direction. After 1200 times thermocycling between $5^{\circ}C$ and $55^{\circ}C$, shear bond strength was measured in 5mm/min crosshead speed with Instron(Instron Co., U.S.A.), and also treated enamel and dentin were observed with SEM(JEOL Co., Japan). The following results were obtained: 1. In the enamel experimental groups, acid etched following air-abraded group had highest shear bond strength, but there was no significant difference compared to acid etched group. Air-abraded only group had lowest shear bond strength, and there was significant difference compared to the rest of groups. 2. In the dentin experimental groups, acid etched following air-abraded group had highest shear bond strength, but there was no significant difference compared to acid etched group. Air-abraded only group had lowest shear bond strength, and there was significant difference compared to the rest of groups. 3. In the SEM study, air-abraded enamel and dentin had irregular and rough surfaces.

  • PDF

The effect of chlorhexidine varnish application on the shear bond strength of orthodontic brackets (클로르헥시딘 바니쉬의 적용이 교정용 브라켓의 전단접착강도에 미치는 영향)

  • Im, Dong-Hyuk;Kim, Tae-Woo;Chang, Young-Il;Nahm, Dong-Suk;Yang, Won-Sik;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.30 no.2 s.79
    • /
    • pp.215-222
    • /
    • 2000
  • The purpose of this study was to determine whether the application of chlorhexidine varnish affects the shear bond strength and failure pattern of orthodontic brackets or not. The experimental group consisted of 22 human premolars which extracted after chlorhexidine varnish application (4 times for 1 week interval) in vivo, and the control group consisted of 22 human premolars which extracted without any pre-treatment. After all teeth were etched with $37\%$ phosphoric acid gel, metal orthodontic brackets (Q-3002, RMO, USA) were bonded to each tooth using auto-polymerizing orthodontic resin (Ortho-One, Bisco, USA) with the same bonding procedure. The shear bond strength was measured with Instron universal testing machine (model 4466, Instron Ltd., England), and the failure pattern of each bracket was examined with Scanning Electron Microscope (SM 840A, JEOL, Japan). The data were analysed statistically with t-test. The results were as follows : 1. Application of chlorhexidine varnish had no significant effect on the shear bond strength of the orthodontic bracket. 2. There was no significant difference in the failure pattern of orthodontic bracket between the experimental group and the control group.

  • PDF

A Study on Ancient Korean Clothing and Ornaments Through Official Chinese History - focusing on hat and hair style - (중국정사(中國正史) 조선전(朝鮮傳)의 한국(韓國) 고대복식(古代服飾) - 관(冠)과 수발(修髮)을 중심으로 -)

  • Kim, Jin Seon;Koh, Bou Ja
    • Journal of the Korean Society of Costume
    • /
    • v.64 no.1
    • /
    • pp.106-122
    • /
    • 2014
  • This study is based on the official Chinese history of the ancient Korean(中國正史朝鮮傳) clothing and ornaments, and also tries to discover, study, and adjust the system of the ancient Korean clothing and ornaments. Ancient Korea has very poor official records of its clothing and ornaments. Therefore, this study had no choice but to rely on the official Chinese history to cover for the lack of resources. The official Chinese history documents are not only important for studying ancient Korean history, but also important for studying about the ancient Korean clothing and ornaments. This research selected historical documents about the ancient Korean clothing and ornaments from fifteen different Chinese dynasties' official documents, and then systematically classified the documents in order to compare them. All these processes confirmed the following subjects. In regards to the Kwan(冠: general hat), the hat types included Check, Byun(弁), Jeol-poong(折風), Jowoo-Kwan(鳥羽冠), So-gol(蘇骨), and Na-kwan(羅冠). These Kwan(冠) were influenced from Chinese clothing and ornaments. Gold and silver decorations on the Kwan(冠) were influenced from the Scythai culture. The feather decorations on the hat were residual of the bird worshiping culture or the hunting lifestyle. These things show that the ancient Korean clothing and ornaments originated the clothing and ornaments from the North. But the use of Jo-woo(bird feather) was common around the globe in many ways during the ancient times, regardless of area and period. The official Chinese history describes men's hair style as Choo-gyul (椎結) or sometimes pronounced, Choo-gyul(椎結). These seem to describe the topknot. Women had various types of hair styles such as Yu-byun-bal-su-hu (wear women's hair in a braid). The official Chinese history show that the ancient Korean clothing and ornaments originated the clothing and ornaments from the north. The ancient Korean clothing and ornaments influenced and were influenced by its neighboring countries.

The effect of low temperature aging on the mechanical property & phase stability of Y-TZP ceramics

  • Kim, Hyung-Tae;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jai-Bong;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.3
    • /
    • pp.113-117
    • /
    • 2009
  • STATEMENT OF PROBLEM. Recently Yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) has been introduced due to superior flexural strength and fracture toughness compared to other dental ceramic systems. Although zirconia has outstanding mechanical properties, the phenomenon of decrease in the life-time of zirconia resulted from degradation in flexural strength after low temperature aging has been reported. PURPOSE. The objective of this study was to investigate degradation of flexural strength of Y-TZP ceramics after various low temperature aging treatments and to evaluate the phase stability and micro-structural change after aging by using X-ray diffraction analysis and a scanning electron microscope (SEM). MATERIAL AND METHODS. Y-TZP blocks of Vita In-Ceram YZ (Vita Zahnfabrik, Bad $S\ddot{a}ckingen$, Germany) were prepared in 40 mm (length) $\times$ 4 mm (width) $\times$ 3 mm (height) samples. Specimens were artificially aged in distilled water by heat-treatment at a temperature of 75, 100, 125, 150, 175, 200, and $225^{\circ}C$ for 10 hours, in order to induce the phase transformation at the surface. To measure the mechanical property, the specimens were subjected to a four-point bending test using a universal testing machine (Instron model 3365; Instron, Canton, Mass, USA). In addition, X-ray diffraction analysis (DMAX 2500; Rigaku, Tokyo, Japan) and SEM (Hitachi s4700; Jeol Ltd, Tokyo, Japan) were performed to estimate the phase transformation. The statistical analysis was done using SAS 9.1.3 (SAS institute, USA). The flexural strength data of the experimental groups were analyzed by one-way analysis of variance and to detect statistically significant differences ($\alpha$= .05). RESULTS. The mean flexural strength of sintered Vita In-Ceram YZ without autoclaving was 798 MPa. When applied aging temperature at below $125^{\circ}C$ for 10 hours, the flexural strength of Vita In-Ceram YZ increased up to 1,161 MPa. However, at above $150^{\circ}C$, the flexural strength started to decrease. Although low temperature aging caused the tetragonal-to-monoclinic phase transformation related to temperature, the minimum flexural strength was above 700 MPa. CONCLUSION. The monoclinic phase started to appear after aging treatment above $100^{\circ}C$. With the higher aging temperature, the fraction of monoclinic phase increased. The ratio of monoclinic/tetragonal + monoclinic phase reached a plateau value, circa 75% above $175^{\circ}C$. The point of monoclinic concentration at which the flexural strength begins to decrease was between 12% and 54%.

COMPARATIVE STUDY ON THE FRACTURE STRENGTH OF EMPRESS 2 CERAMIC AND TARGIS-VECTRIS CROWN

  • Cha Young-Joo;Yang Jae-Ho;Lee Sun-Hyung;Han Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.599-610
    • /
    • 2001
  • Due to an increasing interest in esthetics and concerns about toxic and allergic reactions to certain alloys, patients and dentists have been looking for metal-free tooth-colored restorations. Recent improvement in technology of new all-ceramic materials and composite materials has broadened the options for esthetic single crown restorations. The aim of this investigation was to study the fracture strength of the metal-free posterior single crowns fabricated using two recently introduced systems, Empress 2 ceramic and Targis-Vectris. Forty premolar-shaped stainless steel dies with the 1mm-wide circumferential shoulder were prepared. Ten cylindrical crowns having a diameter of 8.0mm and total height of 7.5mm were fabricated for each crown system respectively(PFM, Empress staining technique, Empress 2 layering technique, and Targis- Vectris). The crowns were filled with cement and placed on the stainless steel dies with firm finger pressure. The crowns were then stored in distilled water at room temperature for 24 hours before testing. The crowns were tested for fracture strength in an Instron universal testing machine (Instron 6022). With a crosshead speed of 1mm/min the center of the occlusal surface of the crown was loaded using a 4-mm-diameter stainless steel ball until fracture occurred. The fracture surfaces of the crowns were gold coated and examined using scanning electron microscopy(Jeol JSM-840 Joel Ltd., Akishima, Tokyo, Japan). Within the parameters of this study the following conclusions were drawn: 1. The mean fracture strength for PFM crowns was 5829(${\pm}906$)N; for Empress staining technique the fracture strength was 1697(${\pm}604$)N; for Empress 2 Layering technique the fracture strength was 1781N(${\pm}400$)N, and the fracture strength for Targis- Vectris was 3093(${\pm}475$)N. 2. The fracture strength of the PFM crowns was significantly higher than that of the Empress 2 and the Targis-Vectris crowns (P<0.05). 3. The fracture strength of the Targis-Vectris crowns was significantly higher than that of the Empress 2 crowns (P<0.05). 4. No statistical difference was found when Empress staining technique was compared with Empress 2 layering technique. 5. The SEM image of fracture surface of Empress 2 crown showed a very dense microstructure of the lithium disilicate crystals and the SEM image of fracture surface of Targis-Vectris crown showed indentations of Vectris and some fibers tom off from Vectris.

  • PDF

AN EXPERIMENT STUDY ON THE BOND STRENGTH OF ADHESIVE RESINS TO SUEEXSSIVELY RECAST ALLOYS FOR REISN-BONDED RESTORATIONS (반복주조된 치과용 합금의 피착면 처리방법에 따른 접착성 수지와의 접착강도에 관한 실험적 연구)

  • Jung, Kum Tai;Yang, Jae Ho;Lee, Sun Hyung;Jung, Hun Yung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.53-76
    • /
    • 1990
  • The purpose of this study was to evaluate the tensile bond strength of adhesive resins to successively recast Rexillium III and Degudent-U. Recasting was done 4times successively. Specimen $A_1$, were cast by new metal, and $A_2$ by surpus of $A_1$, $A_3$ by surplus of, $A_2$ $A_4$ by surplus of $A_3$, $A_5$ by surplus of $A_4$ plus 50% new metal. The types of surface treatment for resinbonded restoration in this experiment were electrolytic etching by OXY-ETCH(Oxy dental products, Inc., Hillside, New Jersey, U.S,A.), aluminum oxide blasting, anodic oxidation by EZ-OXISOR( Towagiken Co., Kyoto, Japan), electrotinplating by Kura Ace(Kuralay Co., Kyoto, Japan). Three kinds of cementing resin used in this study were Comspan(K.P. Cauil Co, Milford Delaware, U.S.A.), Super Bond C&B(Sun-Medical Co. Ltd., Kyoto,Japan), Panavia EX(Kuralay Co., Ltd., Osaka, Japan). Tensile bond strength was measured by Instron Universal testing machineModel 1125) and all the specimen were observed with SEM(JEOL, JSM-T2000) and mode of bond failure were recorded. The obtained results were as follows : 1. In electrolytic etched group, tensile bond strength was decreassed when recast alloy was used, and tensile bond strength of Compan and panavia EX were not significantly different(P>0.05). 2. In remaining group treated by aluminum oxide blasting, EZ-OXIOR, Kura Ace, tensile bond strength were not changed when recast alloy were used, and tensile bond strength of SuperBond(C&B and Panavia EX were not significantly different(P>0.05). 3. IN SEM evaluation, electrolytic etched group and electrotinplated group exhibited different image when recast alloy was used, and remaining groups treated by aluminum oxide blasting, EZ-OXISOR exhibited the same. 4. IN observation of bond failure, electrolytic etched group exhibited adhesive failure and remaing groups treated by aluminium oxid blasting, EZ-OXISOR, Kura Ace exhibited adhesive and cohesive failure.

  • PDF

A Scanning electron microscopic study of the dentinal tubule obliteration effect by the different irradiations of a pulsed Nd:YAG laser (Nd:YAG 레이저의 조사방법의 차이에 따른 상아세관 폐쇄효과에 관한 주사전자현미경적 연구)

  • Ko, Eun-Young;Kim, Song-Wook;Yum, Chang-Yup;Kim, Byoung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.4
    • /
    • pp.829-844
    • /
    • 1997
  • Dentin hypersensitivity must be one of the most frequent postoperative complaints in periodontal patients. Obliterating the open dentinal tubules or decreasing the diameter of their orifices would, therefore, be an objective of treatment for hypersensitive teeth. The purpose of this study was to evaluate the effect of a pulsed Nd:YAG laser irradiation on obliteration of dentinal tubules and to determine any difference according to irradiation methods. The 45 posterior teeth that had been extracted due to periodontal disease were initially treated with tetracycline HCI(100 mg/ml, 4 min.) to remove the smear layer after root planing. The root surfaces were then irradiated by a pulsed Nd:YAG laser(EL.EN.EN060, Italy) by different laser beam spot size and different exposure condition: ${\cdot}$ group 1: irradiated group by small spot(beam diameter=1mm, lW, 2 sec) ${\cdot}$ group 2: irradiated group by large spot(beam diameter=10mm, 1W, 200 sec) ${\cdot}$ group 3: irradiated group by gradual increase of watt (from 0.3W to 1.0W), beam diameter=4mm ${\cdot}$ group 4: irradiated group by fixed watt(1.0 W), beam diameter=4mm ${\cdot}$ control group: no irradiation but root planing and tetracycline HCI conditioning only. Additionally, the specimens were retreated with tetracycline HCI(100mg/ml, 4min.) to evaluate the stability of obliteration effect by Nd:YAG laser. Specimens were examined under the scanning electron microscope(JEOL, JSM-840A, Japan). Photomicrographs were taken at ${\times}4,000$ magnification and were analyzed statistically. The results were as follows: l. Scanning electron micrographs of root surface treated by tetracycline HCI alone(control group) showed widened, funnel-shaped dentinal tubules, while those of the root surface irradiated by various methods showed partially or completely obliterated dentinal tubules and various surface alterations, eg, flat, multiple pitted, melted and resolidified surface at the same energy density. 2. There was no significant difference in the obliteration effect of dentinal tubules between group 1 and group 2, and between group 3 and group 4(p>0.05). 3. The obliteration effect of dentinal tubules by a Nd:YAG laser irradiation was relatively stable to tetracycline HCI. The results demonstrate that a pulsed Nd:YAG laser irradiation within 1.0W, regardless of irradiation methods, can obliterate dentinal tubules effectively.

  • PDF

Detection of Irradiated Milk Formulas using Electron Spin Resonance (전자스핀공명법(ESR)을 이용한 방사선조사 조제유류의 판별)

  • Woon, Jae-Ho;Park, Byeong-Ryong;Choi, Byung-Kook;Kim, Na-Young;Jeong, Hong-Jeom;Cheong, Ki-Soo;Kim, Hee-Sun;Kim, Chang-Seob
    • Journal of Dairy Science and Biotechnology
    • /
    • v.28 no.2
    • /
    • pp.13-18
    • /
    • 2010
  • Electron Spin Resonance (ESR) spectroscopy has been used to detect the presence of radiation-induced free radicals in biological samples since the mid 1950s and to irradiate foods containing cellulose, crystalline sugar, and bone. Therefore, we analyzed the ESR spectrum of irradiated infant formula and its ingredients in this study. Samples were irradiated with 2 different radiation sources of $^{60}Co$ gamma rays and electron beams (EBs), and the absorbed doses were 0, 1, 3, 5, and 7 kGy. ESR measurements were performed under normal atmospheric conditions using a JEOL JES-FA100 spectrometer equipped with an X-band bridge. Irradiated infant formula showed anunsymmetrical spectrum ($g_1$=2.0050, $g_2$=2.0006); in contrast, non-irradiated samples showed asymmetrical spectrum. The ingredients of irradiated samples showed a multi-component ESR signal in glucose and lactose and a singlet-type spectrum in milk powder (g=2.0050). $R^2$ of the dose-response curve showed a fine linearity of over 0.95 across the entire sample. We also compared the spectra of identical samples irradiated with $^{60}Co$ gamma rays and EBs, because EBs can be used for food irradiation in foreign countries, although this is not permitted in Korea. However, we could not find any significant differences according to the types of radiation source. Thus, ESR spectroscopy can be used to detect irradiated infant formula and several types of primary ingredients in this formula.

  • PDF