• Title/Summary/Keyword: JSME S 001-1981

Search Result 3, Processing Time 0.025 seconds

A Study on the Effect of Temperature on the Elastic-Plastic Fracture Toughness $J_{IC}$ of Materials (I) - A Comparative Study of $J_{IC}$ Test Methods Recommended by ASTM and JSME - (재료의 탄소성 파괴인성치 $J_{IC}$의 온도 의존성에 관한 연구 I - AST과 JSME의 $J_{IC}$ 시험법에 관한 비교연구 -)

  • 석창성;최용식;양원호;김영진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.4
    • /
    • pp.653-659
    • /
    • 1989
  • Elastic-plastic fracture toughness J$_{IC}$ can be used as an effective design criterion in elastic plastic fracture mechanics. In the J$_{IC}$ test methods approved by ASTM and JSME, there are discrepancies such as the definition of J$_{IC}$, the slope of the blunting line, curve fitting method and the measurement of crack extension etc. The objective of this paper is to evaluate the effect of these discrepancies on the determination of J$_{IC}$ values. Fracture toughness tests were performed on A516, SA508 and SCM415 steels, and test results were analyzed according to ASTM E 813-81, ASTM E 813-87 and JSME S 001-1981. Results showed significant differences depending on the analysis methods. Therefore, a conversion equation between two ASTM methods was proposed, and the conversion error was within acceptable range(less then 8.5%)en 8.5%)

An Evaluation of Cast Stainless Steel (CF8M) Fracture Toughness Caused by Thermal Aging at 43$0^{\circ}C$

  • Kwon, Jae-Do;Ihn, Jae-Hyuj;Park, Joong-Cheul;Park, Sung-Jong
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.7
    • /
    • pp.902-910
    • /
    • 2002
  • Cast stainless steel may experience embrittlement when it is exposed approximately to 300$\^{C}$ for a long period. In the present investigation, the three classes of the thermally-aged CF8M specimen were prepared using an artificially-accelerated aging method. After the specimens were held for 300, 1800 and 3600hrs. at 430$\^{C}$, respectively, the specimens were quenched in water which is at room temperature. Load versus load line displacement curves and J-R curves were obtained using the unloading compliance method. talc values were obtained using the ASTM E813-87 and ASTM E 813-81 methods. In addition to these methods, talc values were obtained using the SZW (stretch zone width) method described in JSME S 001-1981. The results of the unloading compliance method are J$\_$Q/=543.9kJ/㎡ for virgin materials. The values of J$\_$IC/ for the degraded materials at 300, 1800 and 3600hrs. are obtained 369.25kJ/㎡, 311.02kJ/㎡, 276.7kJ/㎡, respectively. The results obtained by the SZW method are compared with those obtained by the unloading compliance method. Both results are quite similar. Through the elastic-plastic fracture toughness test, it is found that the value of loc is decreased with an increase of the aging time.

A Study on the 43$0^{\circ}C$ Degradation Behavior of Cast Stainless Steel(CF8M) (III) - Evaluation of Elastic-Plastic Fracture Toughness - (주조 스테인리스강 CF8M의 43$0^{\circ}C$ 열화거동에 관한 연구 (III) - 탄소성 파괴인성 평가 -)

  • Gwon, Jae-Do;In, Jae-Hyeon;Park, Jung-Cheol;Choe, Seong-Jong;Park, Yun-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2405-2412
    • /
    • 2000
  • A cast stainless steel may experience an embrittlement when it is exposed to approximately 30$0^{\circ}C$ for long period. In the present investigation, The three classes of the thermally aged CF8M specimie n are prepared using an artificially accelerated aging method. Namely, after the specimen are held for 300, 1800 and 3600hrs. at 43$0^{\circ}C$ respectively, the specimens are quenched in water to room temperature. Load versus load line displacement curves and J-R curves are obtained using the unloading compliance method. $J_{IC}$ values are obtained following ASTM E 813-87 and ASTM E 813-81 methods. In addition to these methods, JIC values are obtained using SZW(stretch zone width) method described in JSME S 001-1981. The results of the unloading compliance method are $J_Q$=485.7 kJ/m$^2$ for virgin material, $J_{IC}$ of the degraded materials associated with 300, 1800 and 3600hrs are obtained 369.25 kJ/m$^2$, 311.02 kJ/m$^2$, 276.7 kJ/m$^2$, respectively. The results of SZW method are similar to those of the unloading compliance method. Through the elastic-plastic fracture toughness test, it is found that the value of $J_{IC}$ is decreased with increasing of the aging time. The results obtained through the investigation can provide reference data for a leak before break(LBB) of reactor coolant system of nuclear power plants.