• Title/Summary/Keyword: JEAC

Search Result 4, Processing Time 0.03 seconds

A Study on the Nonlinear Restoring Force Characteristics for Shear Wall Structures by JEAC 4601 (JEAC 4601에 의한 전단벽 구조물의 비선형 복원력 특성에 대한 고찰)

  • Lee, Won Hun;Kim, Hee Kyun;Song, Sung Bin;Hwang, Kee Tae
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.25 no.3
    • /
    • pp.121-128
    • /
    • 2021
  • Structures of domestic nuclear power plants are designed to perform elastic behavior against beyond design earthquakes, but studies on the nonlinear behavior of structures have been insufficient since the beyond design earthquake. Accordingly, it is judged that it will be necessary to develop an evaluation method that considers the nonlinear behavioral characteristics to check the safety margin for a standard nuclear power plant structure. It is confirmed that the restoring force characteristics for each member level can be identified through the calculation formula, and the lateral stiffness for each story can also be easily calculated by JEAC 4601. In addition, as a result of applying the evaluation method of JEAC 4601 as a nonlinear restoring force model of the nuclear power plant, a certain degree of safety margin can be identified.

A Study of Japan FRT Grid Interconnection Code Based JEAC 9701-2012 (JEAC 9701-2012 기반 일본 FRT 계통연계 규정에 대한 고찰)

  • Myung, Hong-Jae;Kim, Young-Min;Kim, Hee-Jung;Lee, Il-Yong;Do, Won-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1078-1079
    • /
    • 2015
  • 동일본 대지진 이후로 일본은 원자력 발전 가동을 점차 중단시켜 가고 있으며 이에 따라 신재생에너지 발전 비중은 높아지고 있다. 이러한 신재생 에너지원의 확대는 계통의 입장에서 외란의 요소로 작용할 수 있으므로 각 전력회사들은 계통 보호 협조에 관한 규정을 엄격히 적용해 가는 추세이다. 본 논문에서는 일본형 대용량 계통연계형 태양광 인버터들이 가져야 할 기능 중 계통보호 협조에 관한 FRT 기능에 대하여 일본 계통연계 규정인 JEAC 9701-2012[1] 를 기반으로 알아보고 이 규정이 적용되어 개발 된 LS산전의 250/500kW 태양광 PCU를 소개하고자 한다.

  • PDF

A Study on the Measurement Technique of the Grounding Mesh Resistance by Field Measurements (현장실측에 의한 메시(Mesh)접지저항 출정기법 연구)

  • 한기붕;김삼수;정세중;이상익
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.426-429
    • /
    • 1999
  • In this paper, we have provided the measurement technique of the grounding mesh resistance by field measurements. The standard of measurement is specified in the IEEE Std 81.2-1991 and JEAC 5001-1988, which is the the fall-of-potential method by test-current injection, but this method is difficult to apply at field, where is small around a electric power substation of domestic. For the convenient measurement method, space of assistant probe and quantity of test-current injection are changed step for step. As the result, ' the proposed measurement technique of grounding mesh resistance is that the space of current and potential probes must be fixed at 150rn from a grounding mesh, the test-current injection has to keep 5A or more.

  • PDF

A Study of Japan FRT Grid Interconnection Code (일본 FRT 계통연계 규정에 대한 고찰)

  • Myung, Hongjae;Oh, Pilkyoung;Heo, Woonyoung;Ahn, Kyungpil;Kim, Heejung
    • Proceedings of the KIPE Conference
    • /
    • 2013.11a
    • /
    • pp.113-114
    • /
    • 2013
  • 일본은 동일본 대지진 이후로 원자력 발전 가동을 점차 중단시켜 가고 있는 추세이고 이에 발 맞추어 신재생에너지 발전 비중은 높아지고 있다. 특히 태양광 발전에 대한 관심은 주택용 뿐 아니라 발전소 수준의 메가솔라 시장으로 확대 되어 가고 있다. 본 논문에서는 일본형 대용량 계통연계형 태양광 인버터들이 가져야 할 기능 중 FRT 기능에 관해 일본 계통연계 규정인 JEAC 9701-2010을 기반으로 알아보고자 한다.

  • PDF