• 제목/요약/키워드: J-tube Conduit

검색결과 7건 처리시간 0.019초

Riser Installation by a J-Tube Pulling Method

  • Park, H.S.;J. H. Jung
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.110-116
    • /
    • 2000
  • The analysis was carried out for a riser installation by a J-tube pulling method. The J-tube system components, mechanics of pull-in operation, and the theoretical background for the J-tube pull-in was investigated. A computer program was developed to calculate the pull-in force for a riser installation by a J-tube pulling method.

  • PDF

Development of the KSTAR Superconductor

  • Lim B.S.;Choi J.Y.;Lee S.I.;Kim D.J.;Park W.W.;Woo I.S.;Song Y.J.;Song N.H.;Kim C.S.;Lee D.G.;Kim K.P.;Park H.T.;Joo J.J.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권2호
    • /
    • pp.25-28
    • /
    • 2006
  • The magnet system of KSTAR(korean Superconducting Tokamak Advanced Research) is consisted of 16 TF (Toroidal Field) coils and 14 PF (Poroidal Field) coils. Internal cooling CICC(Cable in Conduit Conductor) type conductor is used for both of TF and PF coil systems. The conduit material for $Nb_3Sn$ cable is Incoloy 908 and 316LN stainless-steel was used as conduit material for NbTi cable. $Nb_3Sn$ CICC is used for all TF coils and PF1-5 coils while NbTi CICC is used for PF6 and 7 coils. $Nb_3Sn$ and NbTi strands were made for KSTAR superconducting strand. They are satisfied with KSTAR superconducotr requirements. The $Nb_3Sn$ strands supplied from three companies; MELCO (Mitsubishi Electric Co.), OAS (Outokumpu Advanced Superconductor) and KAT (Kiswire Advanced Technology) were used. A special CICC jacketing system is developed for the KSTAR CICC fabrication which uses the tube-mill process consisted of forming, welding, sizing and squaring procedures. The. procedures for cabling and jacketing of CICC for TF and PF coils and their results including the geometrical specification and characteristics of strands are described.

튜너 내장 자동차 조향호스의 해석 모델과 실용적 응용 (On the Analytical Model of Automotive Steering Hoses Containing Tuner and Its Practical Application)

  • 이재천;오상흔
    • 유공압시스템학회논문집
    • /
    • 제6권1호
    • /
    • pp.1-9
    • /
    • 2009
  • This study presents an analytical model of an automotive steering hose containing tuner(flexible spiral metal tube) to reduce the ripple pressure induced by steering vane pump. The double-wall side branch composed in a steering hose containing tuner was analogically considered as a filter in a conduit. Specialized test equipment was manufactured for the estimation of speed of sound in a conduit and measurement of amplitude ratio between the propagated ripple pressures of inlet and outlet of the steering hose. Experimental data of entire frequency ranges can be obtained through the test once in short time. The results of three points' measurement method and cross-correlation method to estimate the speeds of sound in a hose, tuner, and side branch respectively reveal that cross-correlation method can be used practically. The results of simulation and experiment were so close, especially in the range of engine idling speed, that the proposed analytical model in this study was validated. Sensitivity analyses and experiments show that longer tuner is preferable, and that the positive-positive composition of the steering hoses containing tuner is superior to others to attenuate ripple pressure.

  • PDF

NbTi 관내 3연선 도체의 안정성 (Stability of Triplet NbTi Cable-In-Conduit Conductor)

  • 장현만;오상수;하동우;하홍수;배준한;김상철;류강식;왕추량
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.82-84
    • /
    • 1998
  • The normal zone propagation velocity and minimum quench energy (MQE) of cable-in-conduit conductors (CICC) has been investigated at the different background magnetic fields and supercritical helium pressures. The sample CICC of 2 m in length was fabricated with triplet NbTi/Cu strands inserting into a round stainless-steel tube. The heat pulse disturbance with duration time about 400 ms was acted on the center region of the CICC to quench the strands. The normal zone propagation velocity increased with operating current of the CICC. The measured velocity with respect to operation current could be fitted with numerical results.

  • PDF

KSTAR PF Coil용 CICC 제작 (Fabrication of KSTAR PF CICC)

  • 임병수;이상일;최정열;정우호;박현기;추용;박갑래;백설희;김기만
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.301-303
    • /
    • 2003
  • The KSTAR(Korea Superconducting Tokamak Advanced Research) superconducting magnet system consist of 16 TF(Toroidal Field) and 14 PF(Poloidal Field) coils. Internally-cooled cabled superconductors will be used for the magnet system. The magnet system adopt a superconducting CICC (Cable-In-Conduit Conductor) type. The KSTAR PF 6, 7 CICCs use NbTi Superconducting cable with stainless steel 316LN conduit while the other PF CICC use Incoloy 908 conduit. For the fabrication of PF CICC, superconducting cables have been fabricated and the cable has the diameter of 22.3mm. A continuous CICC jacketing system is developed for the CICC jacketing and the jacketing system uses the tube-mill process, which consists of forming, welding, sizing and squaring procedures. The cabling and the jacketing process is described. The welding condition and design specification of CICCs are also discussed. The fabrication results including the geometrical specification and the void fraction will be discussed.

  • PDF

Modeling and simulation of air-water upward annular flow characteristics in a vertical tube using CFD

  • Anadi Mondal;Subash L Sharma
    • Nuclear Engineering and Technology
    • /
    • 제56권7호
    • /
    • pp.2881-2892
    • /
    • 2024
  • Annular flow refers to a special type of two-phase flow pattern in which liquid flows as a thin film at the periphery of a pipe, tube, or conduit, and gas with relatively high velocity flows at the center of the flow section. This gas also includes dispersed liquid droplets. The liquid film flow rate continuously changes inside the tube due to two processes-entrainment and deposition. To determine the liquid holdup, pressure drop, the onset of dryout, and heat transfer characteristics in annular flow, it is important to have proper knowledge of flow characteristics. Especially a better understanding of entrainment fraction is important for the heat transfer and safe operation of two-phase flow systems operating in an annular two-phase flow regime. Therefore, the objective of this work is to develop a computational model for the simulation of the annular two-phase flow regime and assess the various existing models for the entrainment rate. In this work, Computational Fluid Dynamics (CFD) in ANSYS FLUENT has been applied to determine annular flow characteristics such as liquid film thickness, film velocity, entrainment rate, deposition rate, and entrainment fraction for various gas-liquid flow conditions in a vertical upward tube. The gas core with droplets was simulated using the Discrete Phase Model (DPM) which is based on the Eulerian-Lagrangian approach. The Eulerian Wall Film (EWF) model was utilized to simulate liquid film on the tube wall. Three different models of Entrainment rate were implemented and assessed through user-defined functions (UDF) in ANSYS. Finally, entrainment for fully developed flow was determined and compared with the experimental data available in the literature. From the simulations, it was obtained that the Bertodano correlation performed best in predicting entrainment fraction and the results were within the ±30 % limit when compared to experimental data.

KSTAR PF 코일 시스템을 위한 CICC 제작 (Development of CICC for KSTAR PF coil system)

  • B. Lim;S. Lee;J. Choi;J. Kim;Y. Chu;H. Park;M. Kim;S. Baang;W. Chung
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.306-309
    • /
    • 2002
  • A superconducting CICC (Cable-In-Conduit-Conductor) is adopted the KSTAR (Korea Superconducting Tokamak Advanced Research) superconducting magnet system which consists of 16 TF coils and 14 PF coils. For the test of KSTAR CICC, an ambient magnetic field of $\pm$ 8 T With a maximum change rate of 20 T/s is required and a background-field magnet system is being developed for SSTF (Samsung Superconductor Test Facility). The CICC for PF1~5 is used as the conductor for background-field coils to check the validity of the PF CICC design. Two pieces of cables have been fabricated and the cable has the length of 870 m and the diameter of 20.3 mm. A continuous CICC jacketing system is developed for the KSTAR CICC fabrication and the jacketing system uses the tube-mill process, which consists of forming, welding, sizing and squaring procedures. The design specification of CICCs and the fabrication process is described.

  • PDF