• Title/Summary/Keyword: J-T refrigeration

Search Result 57, Processing Time 0.029 seconds

A Study on The Drying and Hot Water System Using Condensation Waste Heat (응축폐열을 이용한 건조 및 온수장치에 관한 연구)

  • Park N. H.;Koh H. Y.;Jeong J. W.;Kang T. S.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.15 no.4
    • /
    • pp.362-371
    • /
    • 1986
  • In the normal Refrigeration process, the condensation heat of refrigerant s not been used because of its low-temperature waste heat. To recover the condensation waste heat of R-12 refrigerator, a drying and hot water system was designed and experimented. The results obtained were summarized as follows: 1. As the temperature a temosphere was increased, the temperature of discharge gas of compressor was increased. And the temperature was $80-84^{\circ}C$ for air condensing type and was $68-71^{\circ}C$ for water condensing type during summer. 2. The condensation waste heat could be obtained up to $50-55^{\circ}C$ of drying heat-source and Hot water in summer. In this case, recovered rate was about $73\%$. And the more temperature of drying Heat-source and Hot water were increased, the more a recovered rate were decreased. 3. When comparing drying characteristics of Agro-products in dryer of waste heat utilization and Hot air, there was no quality difference in products. But drying time of the former was 3 Hours longer than the latter. 4. The condensation waste heat of compressor could be applied into the drying of marine products, the predrying of agro-products and making hot water. And showed high possibility of the waste heat using in low-temperature storage.

  • PDF

The Characteristics of Bubbles in a Column Heat Exchanger for the Application of Direct Contact LNG Evaporator (직접접촉식 LNG기화기 응용을 위한 칼럼 열교환기 기포특성에 관한 연구)

  • Kim, S.J.;Han, S.T.;Kim, J.B.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.2
    • /
    • pp.142-151
    • /
    • 1991
  • In the present investigation, it has been proposed to utilize a direct contact heat exchanger as an evaporator to solve the difficulties such as scaling, corrosion and law thermal efficiencies, associated with the conventional evaporator. Liquified nitrozen was utilized as a working fluid to investigate basic natures of bubble dynamics in the evaporator, and spray nozzles were adopted to inject liquified nitrozen into the spray column with varying flow rates of dispersed phase fluids. Experimentations were carried out in the range of $6.54{\times}10^{-4}kg/s$ - 0.030 kg/s for dispersed phase flow rates with one, three and five nozzle holes. Observing the bubble dynamics for the evaporator the feasibility of utilizing a direct contact heat exchanger as a LNG evaporator has been evaluated. The results show that no eruption phenomena was observed in the present investigation with $LN_2$ and the interface between $N_2$ bubbles and water was fully turbulent. It is believed that the high injection velocity of $LN_2$ through the spray nozzles provide good mixing effects for both heat and mass transfers between water and $N_2$ bubbles. Ice was formed on the surface of the spray nozzle for higher $LN_2$ flow rates. However, even in this case, it is observed that the ice was detached as soon as it was formed. Under the present experimental conditions, the shapes of $LN_2$ bubbles were in the spherical-cap region according to the Clift, Grace and Weber Graphs. The height of foam region caused by the breakup of larger bubbles keeps increasing with high injection velocities until it reaches it's maximum height.

  • PDF

Extraordinary Magnetomechanical Coupling as a Result of a Combined Magnetic Structural Transition in a New Class of Rare Earth Compound

  • Jiles, D.C.;Lee, S.J.;Han, M.;Lo, C.C.H.;Snyder, J.E.;Gschneidner, K.A.;Pecharsky, V.K.;Pecharsky, A.O.;Lograsso, T.;Schlagel, D.
    • Journal of Magnetics
    • /
    • v.8 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • The new class of $Gd_5(Si_xGe_{1-x})_4$ compounds undergoes a simultaneous magnetic/structural phase transition giving a high level of strain that can be induced either by change in temperature or by application of a magnetic field. Profound changes of structural, magnetic, and electronic changes occur in the $Gd_5(Si_xGe_{1-x})_4$ system lead to extreme behavior of the material such as the giant magnetocaloric effect, colossal magnetostriction, and giant magnetoresistance. These unique material characters can be utilized for various applications including magnetic solid refrigerants, sensors, and actuators.

An Experimental Study of Nucleate Boiling Heat Transfer With EHD Technique in CFC-11 and HCFC-123 (Chiller용 냉매 CFC-11과 대체냉매 HCFC-123의 전기장을 사용한 핵비등 열전달 촉진에 관한 연구)

  • Kwak, T.H.;Kim, J.H.;Jung, D.S.;Kim, C.B.;Cha, T.W.;Han, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.4
    • /
    • pp.365-379
    • /
    • 1994
  • Pool boiling experiments were carried out to study the effect of electric field on nucleate boiling heat transfer. CFC-11 and its alternative HCFC-123 were used as working fluids. Boiling on both single tube and a bundle of five tubes was investigated. Heat flux varied from 5 to $25kW/m^2$ while the applied voltage changed from 0 to 1kV. The results showed that at low heat flux where boiling was not present or very weak, electric field-induced forced convection helped increase the heat transfer coefficients of CFC-11 and HCFC-123 significantly(4-15 times increase). However, at higher heat flux, nucleate boiling of CFC-11 which is a highly dielectric fluid, was not affected significantly by the application of electric field. In contrast to CFC-11, even at high heat flux, nucleate boiling of CFC-11 which has a relatively larger electric conductivity than CFC-11, was vigorously increased up to 2-4 times. The additional power required to apply the electric field was 1-2% of the total power consumption by the heater. The increase in overall heat transfer coefficient of evaporators with HCFC -123 was about 40%, suggesting a considerable reduction in evaporator size with EHD technique.

  • PDF

Magnetocaloric Effect of LaPbMnO3 Alloy (LaPbMnO3 합금의 자기열량효과)

  • Min, Seong-Gi;Kim, Kyeong-Sup;Yu, Seong-Cho;Moon, Young-Mo
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.4
    • /
    • pp.236-240
    • /
    • 2005
  • The magnetocaloric effect and magnetization behaviors have been studied for $La_{1-x}Pb_{x}MnO_3$ (x=0.1, 0.2, 0.3) alloys. The Curie temperature increased from 195 K to 352 K with increasing Pb concentration. A large magnetic entropy change (${\Delta}S_M$), which is calculated from H vs M curves associated with the ferromagnetic-paramagnetic transitions, has been observed. The maximum ${\Delta}S_M$ of $La_{0.8}Pb_{0.2}MnO_3$ was 1.22 J/kg K at 294 K for an applied field of 1.5 T. Adiabatic temperature change (${\Delta}T_ad$) was measured directly by a special cryostat. The maximum ${\Delta}T_ad$ of $La_{0.7}Pb_{0.3}MnO_3$ was 1.00 K at 352 K for an applied field of 2 T.

olymerization behavior and thermal characteristics of two new composites at five temperatures: refrigeration to preheating

  • Jafarzadeh-Kashi, Tahereh Sadat;Mirzaii, Marzieh;Erfan, Mohmmad;Fazel, Akbar;Eskandarion, Solmaz;Rakhshan, Vahid
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.4
    • /
    • pp.216-220
    • /
    • 2011
  • PURPOSE. Heat of composite polymerization (HP) indicates setting efficacy and temperature increase of composite in clinical procedures. The purpose of this in vitro experimental study was to evaluate the effects of 5 temperatures on HP of two new composites. MATERIALS AND METHODS. From each material (Core Max II [CM] and King Dental [KD]), 5 groups of 5 specimens each were prepared and their total HPs (J/gr) were measured and recorded, at one of the constant temperatures $0^{\circ}C$, $15^{\circ}C$, $23^{\circ}C$, $37^{\circ}C$ and $60^{\circ}C$ ($2{\times}5{\times}5$ specimens) using a differential scanning calorimetry (DSC) analyzer. The data were analyzed using a two-way ANOVA, a Tukey's test, an independent-samples ttest, and a linear regression analysis (${\alpha}=0.05$). RESULTS. No polymerization reactions occurred at $0^{\circ}C$; then this temperature was excluded from statistical analyses. The mean HP of the remaining 20 KD specimens was $20.5{\pm}14.9$ J/gr, while it was $40.7{\pm}12.9$ J/gr for CM. The independent-samples t-test showed that there were significant differences between the HP of the two materials at the temperatures $15^{\circ}C$ (P=.0001), $23^{\circ}C$ (P=.0163), $37^{\circ}C$ (P=.0039), and $60^{\circ}C$ (P=.0106). Linear regression analysis showed statistically significant correlations between environment temperatures and HP of CM ($R^2=0.777$). CONCLUSION. Using CM is advantageous over conventional composite because of its better polymerization capacity. However due to its high HP, further studies should assess its temperature increase in vivo. Preheating KD is recommended. Refrigerating composites can negatively affect their polymerization potential.

Development and Performance Test of a l00hp HTS Motor

  • Sohn, M.H.;Baik, S.K.;Lee, E.Y.;Kwon, Y.K.;Yun, M.S.;Moon, T.S.;Park, H.J.;Kim, Y.C.;Ryu, K.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.27-31
    • /
    • 2004
  • This paper describes the development and fabrication of a high temperature superconducting motor which consists of HTS rotor and air-core stator. The machine was designed for the rated power of 100hp at 1800 rpm. The HTS field windings are composed of the double-pancake coils wound with AMSC's SUS-reinforced Bi-2223 tape conductor. These were assembled on the support structure and fixed by a bandage of glass-fiber composite. The cooling system is based on the heat transfer mechanism of the thermosyphon by using GM cryocooler as cooling source. The cold head is in contact with the condenser of a Ne-filled thermosyphon. The rotor assembly was tested independently at the stationary state and combined with stator. Characteristic parameters such as reactances, inductances, and time constants were determined to obtain a consistent overview of the machine operation properties. This motor has met all design parameters by demonstrating HTS field winding, cryogenic refrigeration systems and an air-core armature winding cooled with air. The HTS field winding could be cooled down below 30K. No-load test of open-circuit characteristics(OCC) and short-circuit characteristics(SCC) and load test with resistive load bank were conducted in generator mode. Maximum operating current of field winding at 30K was 120A. From OCC and SCC test results synchronous inductance and synchronous reactance were 2.4mH, 0.49pu, respectively. Efficiency of this HTS machine was 93.3% in full load(100hp) test. This paper will present design, construction, and basic experimental test results of the 100hp HTS machine.