• Title/Summary/Keyword: Izod impact strength

Search Result 73, Processing Time 0.027 seconds

Mechanical Properties of Paper Sludge-Polypropylene Composites (제지 슬러지-폴리프로필렌수지 복합재의 기계적 성질)

  • Lee, Phil-Woo;Son, Jung-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.51-62
    • /
    • 1999
  • The objective of this research is to develop paper sludge reinforced thermoplastic composites which incorporate the advantages of each component materials. The effects of paper sludge content(0, 10, 20, 30, 40----), mesh size(20~40, 60~80, less than 100mesh), and coupling agent(Epolene E-43 and Epolene G-3003) on the mechanical properties of paper sludge-polypropylene composites were investigated. Composite density increased with an increase in the paper sludge content. When paper sludge is incorporated into a polypropylene matrix, the flexural properties of the composite increase significantly with an increase in the paper sludge mixing ratio. Especially, flexural modulus was improved with increasing paper sludge content. The flexural strength of composites was improved, but flexural modulus reduced somewhat with decreasing paper sludge particle size. The flexural properties of paper sludge-polypropylene composites were improved by using coupling agents to enhance the bonding between reinforcing filler and matrix. Use of the epolene E-43 and G-3003 resulted in considerable improvement in the flexural strength over control specimens. The flexural strength of the G-3003 composite system is higher than that of the E-43 system. Generally, izod notched impact strength of paper sludge-polypropylene composite decreased slightly, whereas izod unnotched impact strength decreased significantly with increasing paper sludge contents. There was no effects of paper sludge particle size on impact strength of paper sludge-polypropylene composites. And izod unnotched impact strength of epolene E-43 composite system sharply decreased but that of G-3003 composite system was no tendency with increasing additive content.

  • PDF

Improvement research for impact strength of nylon66/silicate composites (나일론66/실리케이트 복합체의 충격특성 개선 연구)

  • Lee, Bom Yi;Kim, Youn Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4653-4658
    • /
    • 2014
  • A study of the improvement in the impact strength is required to apply Nylon 66/silicate composites as an automobile material. Nylon 66/silicate composites were prepared using a twin screw extruder in case of a silicate treatment by ${\gamma}$-APS (S-silicate) and the addition of an octene ${\alpha}$ olefin grafted by maleic anhydride (PE-g-MAH). The chemical structure of the silane treated silicate was measured by Fourier transform infra-red (FT-IR) spectroscopy. The chemical reaction was confirmed by the decrease in the FT-IR intensity of the OH stretching vibration. The thermal properties, intercalation structure, and Izod impact strength were measured by DSC, TGA, XRD, and Izod impact tester. There was no significant effect on the degradation temperature of the Nylon66/silicate composite, but the crystallization temperature and crystallinity increased slightly in the case of the Nylon66/silicate composites. This suggests that the additives act as heterogeneous nuclei on the Nylon 66 matrix. The Izod impact test indicated that S-silicate enhanced the impact performance by up to 24%.

Morphology and Impact Strength of High Density Polyethylene/Polyamide Alloy (HDPE/PA 알로이의 모포로지와 충격강도)

  • Lee, Yong-Moo;Kang, Doo-Whan
    • Elastomers and Composites
    • /
    • v.28 no.4
    • /
    • pp.283-292
    • /
    • 1993
  • The morphology and impact strength of alloys of high density polyethylene(HDPE) and nylon-6(PA) with modified $ethylene-{\alpha}-olefin$ copolymer(OCP) as compatibilizer and impact modifier were measured by the scanning electron microscope(SEM) and the notched Izod impact test(and the high rate impact test), respectively. HDPE is incompatible with PA and specimens obtained from simple mechanical mixing show the inferior properties. However, it was indicated that OCP played roles of not only impact modifier but also compatibilizer. High rate impact test results were different from those of the notched Izod impact test, but in both tests OCP was effective for HDPE/PA blends. From SEM observation, the size of the dispersed phase in alloys prepared with OCP is much smaller than that of alloys without OCP and the interfacial adhesion of alloys prepared with OCP is also better. Toughening mechanism of polymer blends was discussed by combining the morphology analysis with mechanical and thermal properties.

  • PDF

Impact Characteristics and Morphology of Nylon 6/Polypropylene Blends (Nylon 6/Polypropylene 블렌드의 충격특성 및 모폴로지)

  • Kim, Jong-Guk;Yun, Ju-Ho;Go, Jae-Song;Choe, Hyeong-Gi;Kim, Sang-Uk
    • Korean Journal of Materials Research
    • /
    • v.12 no.1
    • /
    • pp.10-15
    • /
    • 2002
  • Melt blends of maleic anhydride grafted polypropylerle(PP-g-MA) and Nylon 6 were prepared to study the influence of chemical reaction between the two polymer components. By adding the MA grafted polystyrene pold (ethylene/butadiene) and polystyrene[SEBS-g-MA] as the compatible modifiers to reinforce the impact resistance, the Izod impact strength, high rate impact strength and morphology were studied. The notched Izod impact strength increased with the content of PP-g-MA and SEBS- g-MA. The energy of high rate impact strength increased as the thickness of specimen increased, while, it increased as the specimen displacement decreased. In the morphology observed by SEM, finally, we confirmed the improvement of the compatibilization and interfacial adhesion with the content of SEBS-g-MA. The continuous phase of PP-g-MA was the main cause of the modified properties.

The Effect of Hot Isostatic Pressing on Mechanical Properties of Cast Aluminum Alloy (주조된 AI 합금의 기계적 성질에 미치는 HIP의 영향)

  • Kim, Gi-Tae;Yang, Hun-Cheol;Choe, Jae-Yun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.3
    • /
    • pp.461-470
    • /
    • 2002
  • The present paper investigates the effect of hot isostatic pressing (HIPing) on mechanical properties, e.g., tensile strength, ductility and impact absorption energy of sand and die casted aluminum alloys. After HIPing at various temperatures and pressure conditions, uniaxial tensile test and Izod impact test of the samples were carried out. The experimental results showed improvements in uniaxial tensile strength, elongation and Izod impact toughness of sand casted aluminum alloy, while deterioration of a tensile strength fur die casted aluminum alloy. The effect of HIPing for microstructure of the cast aluminum alloy was also investigated.

Study on the Physical and Rheological Properties of Nylon66/MWCNT Composites (나일론66/MWCNT 복합체 물성 및 유변학적 특성 연구)

  • Kim, Do Eui;Kim, Youn Cheol
    • Applied Chemistry for Engineering
    • /
    • v.24 no.2
    • /
    • pp.214-218
    • /
    • 2013
  • Nylon66/multi-walled carbon nano tube (MWCNT) composites were fabricated by twin screw extruder. The contents of MWCNT were 1, 3, 5, and 7 wt%. Thermal properties, dispersion, rheological and impact properties were measured by DSC, TGA, X-ray diffraction (XRD), SEM, Dynamic rheometer, and Izod impact tester. The effect of MWCNT on the non-isothermal crystallization of Nylon66 was confirmed by DSC. The complex viscosity at low frequency and the shear thinning tendency of the composites increased with MWCNT content. An increase in the elasticity was confirmed from the decrease in the slop of G'-G" plot. Izod impact strengths of the composites were analyzed as a measure of mechanical properties, which indicated that the composites exhibit a 60% enhancement for the impact strength when 3 wt% MWCNT was added. The dispersion of MWCNT within Nylon66/MWCNT composites was also checked by SEM.

Effect of fiber reinforcement on impact strength of heat polymerized polymethyl methacrylate denture base resin: in vitro study and SEM analysis

  • Mowade, Tushar Krishnarao;Dange, Shankar Pandurang;Thakre, Mrunali Balkrushna;Kamble, Vaibhav Deorao
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.1
    • /
    • pp.30-36
    • /
    • 2012
  • PURPOSE. The aim of this in-vitro investigation was to describe the effect of reinforcement with different fibers on impact strength of heat polymerized poly-methyl methacrylate (PMMA) denture base resin and to analyze the effect of surface treatment of the fibers on the impact strength. MATERIALS AND METHODS. The specimens were fabricated from the dies formed as per standard ASTM D4812. 2% by weight of glass, polyethylene and polypropylene fibers were incorporated in the PMMA resin. The Izod impact testing was performed on the unnotched specimens and the values obtained were analyzed using appropriate one way ANOVA, followed by unpaired t-test. Fractured ends of the samples were subjected to the SEM analysis. RESULTS. The polypropylene fibers with plasma treatment showed the highest impact strength ($9.229{\times}10^2$ J/m) followed by the plasma treated polyethylene fibers ($9.096{\times}10^2$ J/m), untreated polypropylene fibers ($8.697{\times}10^2$ J/m), untreated polyethylene fibers ($7.580{\times}10^2$ J/m), silane treated glass fibers ($6.448{\times}10^2$ J/m) and untreated glass fibers ($5.764{\times}10^2$ J/m). Also the surface treatment of all the fibers has shown the significant improvement in impact strength. Findings of the SEM analysis justified the improvement in impact strength after surface treatment. CONCLUSION. Reinforcement with the fiber is an effective method to increase the impact strength of PMMA denture base resin. The surface treatment of fibers further increases the impact strength significantly.

Properties of Poly(oxymethylene)/Modified Poly[styrene-b-(ethylene-1-butene)-b-styrene] Triblock Copolymer Blends (폴리(옥시메틸렌)/개질 폴리[스티렌-b-(에틸렌-1-부텐)-b-스티렌] 삼블록 공중합체 블렌드의 물성)

  • Jeon, Hyun-Uk;Kim, Seung-Woo;Kim, Gue-Hyun;Kim, Il;Ha, Chang-Sik
    • Polymer(Korea)
    • /
    • v.28 no.2
    • /
    • pp.162-169
    • /
    • 2004
  • Poly[styrene-b-(ethylene-1-butene)-b-styrene] triblock copolymer (SEBS) was functionalized with 0 to 3.0 phr maleic anhydride and the amount of dicumyl peroxide used as an initiator was varied from 0 to 0.3phr. The gel content of the modified SEBS was determined by xylene extraction and poly(oxymethylene) was blended with the modified SEBS. The impact, tensile, flexural strength and morphologies of the blends were investigated. The Izod impact strength of poly(oxymethylene) was improved through its blending with modified SEBS. However, the Izod impact strength of poly(oxymethylene)/modified SEBS blend decreased above 5% modified SEBS content. Regarding the effect of dicumyl peroxide content on the Izod impact strength, the blend had a maximum Izod impact strength when poly(oxymethylene) was blended with modified SEBS prepared with 0.1 phr dicumyl peroxide. It was also confirmed by SEM micrographs that the average particle size of modified SEBS in poly(oxymethylene)/modified SEBS blends was smaller than that of SEBS in poly(oxymethylene)/SEBS blends.

Properties of PA 6,6/Elastomer Blends with Various Elastomer Content (탄성중합체 함유량 변화에 따른 폴리아미드-6,6/탄성중합체 블랜드물의 특성)

  • Lee, Yoong;Lee, Chang-Woo;Cho, Yoon-Ho;Hahm, Yeong-Min
    • Elastomers and Composites
    • /
    • v.34 no.1
    • /
    • pp.20-30
    • /
    • 1999
  • In this study, binary polyamide 6,6(PA 6,6)/ethylene-propylene rubber(EPM) or EPM-g-maleic anhydride(EPM-g-MA) blends and ternary PA 6,6/EPM/EPM-g-MA blends with various elastomer content were prepared in order to investigate the degree of influence of elastomer content and average particle size, morphology, and distribution of dispersed elastomer on mechanical and thermal properties of blends. According to the results, notched Izod impact strength and relative crystallinity of binary blends modified with EPM-g-MA as well as average particle size and distribution of dispersed elastomer in such blends were more improved than those of binary blends modified with EPM. Notched Izod impact strength of blend whose composition ratio(wt % ) was 70:30(PA 6,6 : EPM-g-MA) was the highest among the binary PA 6,6/EPM-g-MA blends. The impact strength was increased by 25 times and its relative crystallinity was increased by 7 times when compared with those of polyamide 6,6. In the case of ternary PA 6,6/EPM/EPM-g-MA blend of which composition ratio was 70:15:15(PA 6,6:EPM:EPM-g-MA), the elastomer was finely distributed with the average particle size of $0.56{\mu}m$. The Izod impact strength of this blend was the highest of all blends prepared with different elastomer content.

  • PDF

Effect of TiO2 Particle Size and Content on the Mechanical Properties of TiO2/Epoxy Composites (TiO2 나노입자의 크기와 함량이 TiO2/Epoxy 복합재료의 기계적 물성에 미치는 영향)

  • Kim, Bu-An;Moon, Chang-Kwon
    • Journal of Power System Engineering
    • /
    • v.21 no.1
    • /
    • pp.11-17
    • /
    • 2017
  • This study is about the mechanical properties of epoxy composite reinforced with nano $TiO_2$ particle. Tensile strength, fracture toughness, vicker's hardness and Izod Impact test were carried out to investigate the effect of particle size and content of $TiO_2$ on the mechanical properties of $TiO_2$/epoxy composites. The results showed that the strength of the $TiO_2$/epoxy composites were higher than that of the pure epoxy. The best improvement of tensile strength was achieved in case of the particle size was 21 nanometer and the content was 3 weight percent. However, the Izod Impact value and the Vicker's hardness of $TiO_2$/epoxy composites showed no clear tendency.