• 제목/요약/키워드: Isothermal Chamber

검색결과 20건 처리시간 0.019초

등온화용기를 이용한 공기압 기기의 성능계측 (Characteristics Measurement of Pneumatic Elements Using Isothermal Chamber)

  • 장지성
    • 동력기계공학회지
    • /
    • 제4권1호
    • /
    • pp.20-25
    • /
    • 2000
  • In this study, methods for the characteristics measurement of pneumatic elements using isothermal chamber, the methods for the flow rate and dynamic characteristic measurement of pneumatic control valve, are proposed. An isothermal chamber is a chamber in which the steel wool is stuffed and isothermal condition can almost be realized. Therefore, the instantaneous flow rate could be measured only from the pressure response using the state equation of gas. Effectiveness and simplicity of the proposed method are confirmed by comparing the measured results obtained by proposed methods with the methods defined JIS and the ISO standards.

  • PDF

등온화용기를 이용한 누설유량 시뮬레이션에 관한 연구 (A Study on the Simulation of Leak Flow-rate Using Isothermal Chamber)

  • 지상원;장지성
    • 동력기계공학회지
    • /
    • 제14권5호
    • /
    • pp.71-75
    • /
    • 2010
  • Leak detection technology is a challenging research until nowadays, because it has wide and various applications in industry. Furthermore pneumatic component reliability test based on ISO requires air leakage measurement. The conventional measurement methods need a complex operation and the calibration of leak detector. Tracing the history of our study, we proposed a new method for measurement of leak flow rate using isothermal chamber. In this study, propose a simulation model of isothermal chamber by infinitesimal flow -rate, such as a leak flow-rate. The effectiveness of the proposed simulation model is proved by simulation and experimental results. Base on the comparison results, proposed simulation model is good agreement with experimental results.

An Isothermal Temperature Source with a Large Surface Area using the Metal-Etched Microwick-Inserted Vapor Chamber Heat Spreader

  • Go, Jeong-Sang;Kim, Kyung-Chun
    • Journal of Mechanical Science and Technology
    • /
    • 제18권4호
    • /
    • pp.681-688
    • /
    • 2004
  • For use of the thermal cycle of the biochemical fluid sample, the isothermal temperature source with a large surface area was designed, fabricated and its thermal characterization was experimentally evaluated. The comprehensive overview of the technology trend on the temperature control devices was detailed. The large surface area isothermal temperature source was realized by using the vapor chamber heat spreader. The cost-effectiveness and simple manufacturing process were achieved by using the metal-etched wick structure. The temperature distribution was quantitatively investigated by using IR temperature imaging system at equivalent temperatures to the PCR thermal cycle. The standard deviation was measured to be within 0.7$^{\circ}C$ for each temperature cycle. This concludes that the presented isothermal temperature source enables no temperature gradient inside bio-sample fluid. Furthermore it can be applied to the cooling of the electronic devices due to its slimness and low thermal spreading resistance.

압축성유체 유량계측장치 설계 및 제작 (Design and Building of Flow-rate Measurement Apparatus for Compressible Fluid)

  • 지상원;장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제10권4호
    • /
    • pp.29-33
    • /
    • 2013
  • Pneumatic system is widely applied in various industry because it have a many advantage(low cost, high safety, etc..). For design of pneumatic system, accurate flow measurement is required. In this study, compressible fluid flow measurement apparatus was designed and built. It uses an isothermal chamber that can approximate isothermal condition. Therefore, it can be measured for flow-rate using pressure response of isothermal chamber. As a result, this apparatus can be measured for sonic conductance and critical pressure ratio of pneumatic components and it required less time and energy than conventional flow meter. The effectiveness of the designed apparatus is proved by experimental result.

공기압실린더의 누설유량 계측에 관한 연구 (A Study on the Measurement Method of Leakage for Pneumatic Cylinder)

  • 장지성;지상원
    • 동력기계공학회지
    • /
    • 제11권4호
    • /
    • pp.98-102
    • /
    • 2007
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measured from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing the steel wool into it. Therefore, a wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

공압실린더의 누설유량 계측방법에 관한 연구 (A Study on the Measurement Method of Leakage Flow-rate for Pneumatic Cylinder)

  • 장지성;지상원;정지현;강보식
    • 유공압시스템학회논문집
    • /
    • 제3권1호
    • /
    • pp.15-19
    • /
    • 2006
  • In this study, a measurement method of leakage flow-rate for pneumatic driving apparatus is proposed. The existing measurement methods of leakage flow-rate of air need disassemble the test component. Therefore, there is no effective method to measure the leakage flow-rate while operating pneumatic driving apparatus. In this study, the leakage flow-rate is measure from the pressure change in an isothermal chamber that can realize isothermal conditions by stuffing steel wool into it. Therefore, wide range of flow-rate could be measured only from the pressure response and the leakage flow-rate can be measured during operating pneumatic driving apparatus. The effectiveness of the proposed method is proved by experimental results.

  • PDF

The Error Analysis of Leak Measurement for Pneumatic Cylinder Using Isothermal Chamber

  • Jang, Ji-Seong;Ji, Sang-Won;Kagawa, Toshiharu
    • 유공압시스템학회논문집
    • /
    • 제5권1호
    • /
    • pp.6-12
    • /
    • 2008
  • ISO pneumatic cylinder reliability test requires air leakage measurement. Air cylinder has many parts and the leakage shall be measured before, during and after endurance test, and, the leakage should smaller than the specified value. The existing measurement method needs complex operation and the calibration of leak detector, and, has to separate the testing cylinder from endurance test device, which causes the change of contact condition of seal in the cylinder. Therefore, it is hard to evaluate the air leakage during endurance test, and guarantee the reliability of the conventional measurement method. In this paper, a new method for air leakage measurement using isothermal chamber, which does not requires calibration or temperature compensation, and, can measure air leakage accurately with quite simple operations, is proposed. As a result, reliability of air leakage measurement can be improved because the proposed method does not have to separate the testing cylinder from the endurance test device for air leakage measurement. The effectiveness of the proposed method is proved by error analysis of leak measurement from experimental result.

  • PDF

소량 기록물의 효율적 보존을 위한 보존챔버 설계에 관한 연구 (A Study on Chamber Design for the Efficient Preservation of a Small Amount of Archives)

  • 봉춘근;박성진;이정주;신현창
    • 한국기록관리학회지
    • /
    • 제13권1호
    • /
    • pp.35-58
    • /
    • 2013
  • 기록물 보존챔버란 소량의 중요기록물을 안정성 높은 보존환경에서 영구보존하는 데 적합한 장비이다. 이 장비는 소량의 기록물을 영구보존하기 위한 공공기관이나 민간단체에서 기록물을 경제적이면서 안전하게 장기보존하기에 적합한 장비이다. 본 연구는 지방기록관의 기록물 보존현황 조사를 통해 보존챔버의 필요성을 분석한 후 보존챔버의 핵심부분을 설계함으로 기록물을 안정적이면서 경제적으로 보존할 수 있는 방안을 모색하였다. 기록물 보존챔버는 크게 기록물을 보존하는 보존공간, 보존환경 유지를 위한 공기정화장치부, 보존환경을 모니터링하기 위한 환경측정장치부로 구성된다. 기록물 보존공간은 외부 공기의 출입을 막고 내부공기가 순환함으로 항온항습 유지 및 유해가스 제거가 가능하도록 하였다. 이렇게 설계된 보존챔버는 소량의 기록물을 서고에서 보존할 때보다 더 경제적으로 보존할 수 있는 것으로 산출되었다.

Measurements of Ventilation Effectiveness in an Underfloor Air-Conditioned Space Using a Tracer Gas Technique

  • Han, Hwa-Taik;Seo, S.Y.;Kim, M.H.;Kim, Young-Il
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.91-100
    • /
    • 1999
  • This paper investigates ventilation characteristics of an environmental chamber simulating an under-floor air conditioning system for isothermal and cooling supply air conditions. The tracer gas sulfur-hexafluoride (SF$F_6$) was injected into a supply duct using step-up and step-down methods. Local mean and room mean ages were calculated from the concentrations measured at internal points and at the exhaust duct. The air change efficiency of the chamber has been found to be greater in cooling conditions than in isothermal conditions. Also the room air change efficiency is not significantly affected but slightly improved by the presence of a supply diffuser.

  • PDF

에어스프링 시스템의 성능 개선에 관한 연구 (A Study on the Performance Improvement of an Air Spring System)

  • 장지성
    • 드라이브 ㆍ 컨트롤
    • /
    • 제10권2호
    • /
    • pp.1-6
    • /
    • 2013
  • This study describes a method which can attenuate reaction force effectively for an air spring system composed of an air spring and auxiliary chamber. For the analysis, the nonlinear governing equation of the air spring system is derived. For a performance improvement of the system, change of the heat transfer effect and the mass flow rates is included in the analysis of the air spring system. The simulation study is presented to show the reaction force is changed by variations in heat transfer characteristics and the air spring system of isothermal process has the best performance. As a result, to improve attenuation characteristics of reaction force, a process in the air spring system should be maintained near isothermal process.