• Title/Summary/Keyword: Isometric voluntary contraction

Search Result 165, Processing Time 0.02 seconds

The Correlation of the Area of the Base of Support with the Maximal Voluntary Isometric Contraction of Upper Limb Muscles (기저면의 넓이와 상지 근육의 최대 수의적 등척성 수축의 상관관계)

  • Lee, Sang-Yeol;Jo, Marg-Eun
    • PNF and Movement
    • /
    • v.14 no.1
    • /
    • pp.49-52
    • /
    • 2016
  • Purpose: The purpose of the present study was to examine the effects of the area of the base of support formed by the human body on the maximal voluntary isometric contraction of upper limb muscles. Methods: The study was conducted with 20 normal adults. To identify changes in the base of support, the maximal voluntary isometric contraction of the biceps muscle was measured in a standing position, a sitting position, and a lying position for each subject. The sizes of the base of support formed in the standing, sitting, and lying positions were set to 1, 2, and 3 respectively, based on the sizes, to analyze the correlations. The maximal voluntary isometric contraction of the biceps muscle was measured using surface electromyograms (EMGs) (Noraxon DTS, Germany). Results: The results showed negative correlations in which, as the size of the base of support increased, the maximal voluntary isometric contraction of the biceps muscle decreased. Conclusion: Changes in the base of support of the body affect the maximal voluntary isometric contraction of the upper limbs. Therefore, when resistance exercises are applied for muscle strengthening, the positions should be changed considering the changes in muscle activity according to those positions. In addition, when EMGs are used to measure the maximal voluntary isometric contraction, the measurements should be conducted in the same positions, considering muscle activity that changes according to the base of support and positions, for data quantification.

What is the Optimal Contraction Intensity and Duration in the Performance of Relaxation Techniques for Maximal Increase of Range of Motion? (관절가동범위 증진을 위한 이완 기법의 적절한 수축강도와 수축시간은?)

  • Shin, Seung-Sub
    • PNF and Movement
    • /
    • v.14 no.1
    • /
    • pp.59-65
    • /
    • 2016
  • Purpose: The purpose of this study was to review articles in order to establish optimal contraction intensity and duration in the performance of relaxation techniques for maximal increase in range of motion. Methods: The Cochrane, EBSCO, Embase, Medline, ProQuest, PubMed, ScienceDirect, and Scopus databases were used to search articles from 1990 to January 2016. The search terms were "contract relax," "hold relax," "muscle energy technique (MET)," and "proprioceptive neuromuscular facilitation (PNF) stretching." Only experimental human studies (randomized controlled trials) that compared the effects of varying intensity and duration of isometric contraction were included. Non-English language and unpublished studies were excluded. Results: A total of 2,156 articles were initially identified, with only five eventually meeting the inclusion and exclusion criteria. Three studies compared the effects of varying intensity in isometric contraction and two studies compared the effects of varying duration in isometric contraction with regard to range of motion (ROM). Two articles suggested that submaximal voluntary isometric contraction was more effective than maximum voluntary isometric contraction (MVIC) in the improvement of ROM. One article showed that a longer contraction time led to greater increases in ROM. Conclusion: Submaximal voluntary isometric contraction was recommended during contract-relax exercises in healthy people. Lack of evidence makes it difficult to suggest the optimal duration of isometric contraction during relaxation techniques. For future research, high-quality evidence will be needed to establish the optimal contraction intensity for maximum improvement of ROM.

The Change of the Maximal Isometric Contracture of the Normal and Spastic Muscles in Voluntary Exercise (수의적 운동에 의한 정상근과 경직근의 최대 등척성 수축력 변화)

  • Lim, Sang-Wan;Choi, Eun-Young
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.3 no.1
    • /
    • pp.1-12
    • /
    • 2005
  • This study aimed at examining the maximal isometric contraction caused by voluntary exercise and at comparing its aspects of decrease and restoration in their different repeated application, as to the quadriceps muscles of thigh in the subjects composed of patients with spastic hemiplegia and normal adults. Using isokinetic exercise analyser(Biodex Medical Systems Inc., Biodex System 3PRO, U.S.A.), experiment was conducted as to the normal group composed of fifteen adults and the patient group composed of fifteen patients with spastic hemiplegia. As to each group, MVIC(maximal voluntary isometric contraction) of the quadriceps muscle of thigh caused by voluntary exercise and the aspects of decrease and restoration of the isometric contraction were examined with the method to induce isometric exercise, and their SDI(strength decrement index) and SRI(strength recovery index) were also calculated. The results can be summarized as follows: 1. As for decrease of maximal isometric contraction, both groups showed slow decrease in voluntary exercise, but the normal group showed rapid decrease later phase. 2. As for SDI, no significant differences could be observed in comparison between groups. 3. As for restoration of maximal isometric contraction, both groups showed slow restoration in voluntary exercise, but the normal group showed rapid restoration early phase. 4. As for SRI, comparison between groups showed significant differences in voluntary exercise. These results lead us to the conclusions that spastic muscle is characterized by slow decrease and restoration of MVIC in comparison with normal muscle in voluntary exercise.

  • PDF

Force Depression Following Active Muscle Shortening during Voluntary Contraction in Human Tibialis Anterior Muscle (인체 전경골근의 수의적 수축시 선행 동심성 근수축이 항정상태 등척성 근력에 미치는 영향)

  • Lee, Hae-Dong;Lee, Seung-Cheol
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.75-83
    • /
    • 2006
  • The purpose of this study was to investigate steady-state force depression following active muscle shortening in human tibialis anterior muscle during voluntary contractions. Subjects (n = 7; age $24{\sim}39$ years; 7 males) performed isometric reference contractions and isometric-shortening-isometric contractions, using maximal voluntary effort. Force depression was assessed by comparing the steady-state isometric torque produced following active muscle shortening with the purely isometric reference torque obtained at the corresponding joint angle. In order to test for effects of the shortening conditions on the steady-state force depression, the speed of shortening were changed systematically in a random order but balanced design. Ankle dorsiflexion torque and joint angle were continuously measured using a dynamometer. During voluntary contractions, muscle activation of the tibialis anterior and the medical gastrocnemius was recorded using surface electromyography. Force depression during voluntary contractions, with a constant level of muscle activation, was 12 %, on average over all subjects. Force depression was independent of the speeds of shortening ($13.8{\pm}2.9%$, $10.3{\pm}2.6%$ for 15 and 45 deg/sec over 15 deg of shortening, respectively). The results of this study suggest that steady-state force depression is a basic property of voluntarily-contracting human skeletal muscle and has functional implication to human movements.

The Effects of Microcurrent Electrical Neuromuscular Stimulation on Delayed Onset Muscle Soreness, Serum Creatine Kinase, and Maximal Voluntary Isometric Contraction: A Preliminary Report (미세전류신경근자극이 Delayed Onset Muscle Soreness, 혈청 Creatine Kinase, 최대 수의적 등척성 수축에 미치는 영향)

  • Kim, Tae-Youl;Choi, Eun-Young;Yoon, Hee-Jong
    • Journal of Korean Physical Therapy Science
    • /
    • v.2 no.3
    • /
    • pp.587-598
    • /
    • 1995
  • The purpose of this study was to test the microcurrent electrical neuromuscular stimulation on muscle soreness, serum creatine kinase levels and force deficits evident following a high-intensity eccentric exercise bout. 10 volunteer male subjects were randomly assigned to a treatment group or to a control group. Exercise consisted of high-intensity eccentric contractions of the elbow flexors. Resistance was reduced as subjects fatigued, until they reached exhaustion. Muscle soreness rating was determined using a visual analog scale. Serum creatine kinase levels were analyzed using a blood sample. Force deficits were determined by measures of maximal voluntary isometric contraction at $90^{\circ}$ of elbow flexion on a Orthotron II dynamometer. Muscle soreness rating, serum creatine kinase levels and maximal voluntary isometric contraction were determined at the before exercise and again at 24 and 48 hours postexericse. Treatments were applied immediately following exercise. The control group subjects rested following their exercise bout. Statistical analysis showed significant increases in muscle soreness rating and significant decreases in maximal voluntary isometric contraction when the before exercise was compared with 24 and 48 hour measures(p<0.01). No significant effects were observed between groups in muscle soreness rating and maximal voluntary isometric contraction(p>0.05). Highly significants differences in serum creatine kinase levels were found using on Analysis of variance(ANOVA) repeated measures between groups for each time cycles(p<0.001). This modality may have benefits when used early stage in the muscle damage.

  • PDF

Power Spectal Analysis of Masticatory Muscles during Sustained Isometric Contraction and Recovery at Various Contraction Times (저작근의 등척성 수축시간 변화에 따른 Power Spectrum 분석에 관한 연구)

  • Wook Kim;Heung-Sang Lee;Young-Ku Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.269-281
    • /
    • 1995
  • To study the characteristics of EMG power spectrum of masticatory muscles during sustained isometric contraction and recovery at various contraction times, the author analysed the EMG signals of anterior temporal and masseter muscles before, during, and after sustained isometric contraction at 50% level of maximum voluntary contraction (MVC) for 15,30,60 seconds. Twelve normal subjects were included in this study. The author came to following conclusions from the results. 1. MMF of anterior temporal muscle in the contraction period was significantly higher than that of masseter muscle during sustained isometric contraction regardless of isometric contraction times (p<0.05). 2. MMF in the contraction period decreased as the contraction time increased during sustained isometric contraction in both temporal and masseter muscles(p<0.05). 3. SMF in the contraction period increased as the contraction tie increased during sustained isometric contraction in both temporal and masseter muscles(p<0.01). 4. MMF in the first part of recovery period (20 seconds) decreased as the contraction time increased during sustained isometric contraction(p<0.05). However, MMF in the later parts of recovery period (20-120 seconds) showed no significant differences. 5. MMF of anterior temporl muscle in the recovery period was significantly higher than that of masseter muscle after sustained isometric contraction regardless of isometric contraction times (p<0.05). 6. The recovery rate of MF reached 100% in 100 seconds after the isometric contraction regardless of isometric contraction times.

  • PDF

Changes of Action Potential of Central Neuron by Maximal Voluntary Isometric Contraction (최대 수의적 등척성 수축력에 의한 중추신경원의 활동전위 변화)

  • Moon, Dal-Ju;Kim, Kye-Yoep;Jeong, Jin-Gyu;Kim, Sue-Hyun;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.18 no.3
    • /
    • pp.37-45
    • /
    • 2006
  • Purpose: This study analyzed changes in spinal neuron and action potential of motor unit depending on voluntary contraction on spinal neuron adaptation. Methods: It selected 80 university students in their twenties and divided into experimental groups of 25% MVIC (I), 50% MVIC (II), 75% MVIC (III) and 100% MVIC (IV) depending on maximum voluntary isometric contraction (MVIC) and performed isometric exercise of plantar flexor muscle to each experimental group with given contraction for 20 times. It measured Mmax, H/Mmax, Hmax latency, V/Mmax, V wave latency before and after exercise, compared method and volume of contraction. Results: H/Mmax ratio showed significant difference in comparison among groups (p<0.01) and there was difference in I and IV groups. V/Mmax ratio showed significant difference in comparison among experimental groups (p<0.05) and there was difference in I and IV groups. When voluntary contraction level was maximum, changes were greatest. However, no significantly difference was to Mmax, H latency and V wave latency. Conclusion: These results suggest that amplitude changes of voluntary contraction level, spinal neuron and supra-spinal neuron had a dose connection that the more contraction level, the better central activation seem to decrease highly for a short time.

  • PDF

Quantitative Analysis of EMG Amplitude Estimator for Surface EMG Signal Recorded during Isometric Constant Voluntary Contraction (등척성 일정 자의 수축 시에 기록한 표면근전도 신호에 대한 근전도 진폭 추정기의 정량적 분석)

  • Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.5
    • /
    • pp.843-850
    • /
    • 2017
  • The EMG amplitude estimator, which has been investigated as an indicator of muscle force, is utilized as the control input to artificial prosthetic limbs. This paper describes an application of the optimal EMG amplitude estimator to the surface EMG signals recorded during constant isometric %MVC (maximum voluntary contraction) for 30 seconds and reports on assessing performance of the amplitude estimator from the application. Surface EMG signals, a total of 198 signals, were recorded from biceps brachii muscle over the range of 20-80%MVC isometric contraction. To examine the estimator performance, a SNR(signal-to-noise ratio) was computed from each amplitude estimate. The results of the study indicate that ARV(average rectified value) and RMS(root mean square) amplitude estimation with forth order whitening filter and 250[ms] moving average window length are optimal and showed the mean SNR improvement of about 50%, 40% and 20% for each 20%MVC, 50%MVC and 80%MVC surface EMG signals, respectively.

EMG Power Spectral Analysis on Masticatory Muscle Fatigue in Chronic Muscle Pain Patients (근전도 power spectrum을 이용한 만성근육동통 환자에 있어서의 저작근 피로에 관한 연구)

  • 이채훈;김영구;임형순
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.1
    • /
    • pp.145-155
    • /
    • 1997
  • The purpose of this study was to compare differences in endurance time and EMG power spectral characteristics of the masticatory muscles during sustained isometric contraction between patients and controls. 15 CMD patients{8 women and 7 men, aged 15 to 38 years(24.1$\pm$7.5)}, and 15 healthy volunteers{8 women and 7 men, aged 15 to 30 years(24.7$\pm$3.4)} without past history or present symptoms of CMD were included in this study. Sustained isometric contractions of masticatory muscles were perfomeed as long as possible at 50% level of maximum voluntary contraction(MVC) of EMG activity via visual feedback, and the duration of sustained isometric contraction(endurance time) was examined. The author perfomed EMG power spectral analysis in the myoelectric signals of masseter and anterior temporal muscle during sustained isometric contraction in CMD patients with chronic muscle pain and healthy controls. The author came to following conclusions from the results. 1. The endurance time of the patient group was shorter than the control group in sustained isometric contraction of masticatory muscles(p<0.01). 2. MF values of masticatory muscles with sustained isometric contraction during endurance time were decreased following regression line in both groups(p<0.01, r>0.9). 3. The amount of MF shift to lower frequency range exhibited no significant differences between the patients and the control group in sustained isometric contraction during endurance time. 4. SMF to lower frequency range of the patient group was steeper than the control group in sustained isometric contraction during endurance time(p<0.05).

  • PDF

Reproducibility analysis of surface EMG spike variables during isometric voluntary contraction of the biceps brachii muscle (이두박근의 등척성 자의 수축시 표면근전도 신호에서 검출한 스파이크 변수들의 재현성 분석)

  • Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1246-1254
    • /
    • 2009
  • The reproducibility of initial value and change over time of surface EMG spike variables(MSA, MSF, MSS, MSD) was investigated in the biceps brachii muscle of 11 healthy subjects. Surface EMG signals were recorded during sustained isometric voluntary contractions for 30 seconds at three contraction levels, 20%, 50%, and 80%MVC, respectively. Each contraction was repeated three times in each of three different days for a total of nine contractions and 99 contractions per %MVC level across the eleven subjects. A total of 297 EMG signals across the different trials, days, subjects, and %MVC levels was saved for the subsequent analysis. The degree of reproducibility was investigated using the intraclass correlation coefficient(ICC) and the standard error of the mean(SEM) based upon the analysis of variance(ANOVA), Results for intercept showed higher reproducibility of the spike variables with about 60%-98% ICC than the variable(ARV, MNF) which had been analyzed before in other researches. And results for slope showed poor reproducibility of the spike variables with about 30%-70% ICC and they were comparable with the variables of other researches.