• Title/Summary/Keyword: Isolation ward

Search Result 33, Processing Time 0.019 seconds

A Development of Design Guidelines for the Negative Pressured Isolation Units Controlling Severe Respiratory Infectious Disease (중증 호흡기 감염병 진료를 고려한 음압격리병동부의 건축계획)

  • Kwon, Soon Jung;Yoon, Hyungjin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.22 no.3
    • /
    • pp.45-56
    • /
    • 2016
  • Purpose: The MERS(Middle East Respiratory Syndrome) outbreaks in Korea highlighted dramatically the failings of traditional hospital environment for controlling or preventing infections among both patients and healthcare workers. MERS is transmitted by droplets that can be airborne over a limited area. The point should be emphasized that MERS in South Korea was predominantly a hospital-acquired (not a community-acquired) infection, because approximately 93% of MERS cases were resulted from exposure in hospital settings. This paper tries to suggest the design guidelines of negative pressured isolation ward for the sake of proper control of severe respiratory infectious diseases. Methods: Literature survey on the design guideline and regulations of airborne infection wards in Korea, Europe U.K. and CDC of U.S. have been carries out. 4 special infection wards in Hongkong, Germany, Japan and Korea have been surveyed in order to make the best use of the experiences related to facility design and operations. Results: Operating system influencing the facility design, space organizations of infectious ward including required space and zoning, and circulations of patients, staffs and materials are proposed. Implications: The results of this paper can be the basic data for the design of the airborne infection ward and relevant regulations. Afterwards in-depth study such as the development of space standards for the single bedroom, locker room and so on could be explored.

A Study on the Architectural Planning of a Maternity Ward Focused on Rooming-in System (모자동실 개념을 중심으로 한 산과 병동의 건축계획에 관한 연구)

  • Kim, Eon-Hwa;Yu, Young-Min
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.8 no.2
    • /
    • pp.25-33
    • /
    • 2002
  • The effects and necessity of the breast milk are well known, but the breast-feeding rate in our country is very low. One of the reason is due to the separation policy of mother and baby after delivery. The mother is in the inpatient-room and the baby is in the new-born baby room. This isolation operation of hospital get increased according to the decreasing ratio of breast feeding in Korea. Only a few hospital operates and provides the space for a new-born baby in the mother's room. The system of baby and mother in one room is adopted and operated due to the breast feeding campaign. It is very encouraging, but the space for the baby and the mother is not enough in multi-bed rooms. We should reconsider the relationship between the new-born baby unit and the obstetric ward, and design the patient's room for the baby and the mother.

  • PDF

Comparative Evaluation of Measures against the Spread of Air-borne Infections in a Large National Hospital and Small and Medium-sized Clinics in Korea (국내 대형병원과 중·소규모 의원의 공기감염 확산 방지 대책의 비교 평가)

  • An, Jiwon;Yang, Young Kwon;Won, An-Na;Hwang, Jung Ha;Park, Jin Chul
    • Journal of Korean Living Environment System
    • /
    • v.25 no.1
    • /
    • pp.90-97
    • /
    • 2018
  • The purpose of this study is to compare and analyze the air infections in middle and small hospitals with the facilities of large national hospitals that have air-borne infection isolation (AII) wards through actual condition investigation and airflow analysis simulation (CFD) and to provide basic data for prevention. The method and scope of the study are as follows. First, through literature review, data related to prevention of infection spread in domestic medical institutions were investigated. Second, we conducted a survey on the status of isolation facilities to prevent the spread of infectious diseases in large hospitals and small and medium - sized clinics in Korea. Third, airflow analysis simulation (CFD) was carried out using the isolation ward of the nationally designated inpatient ward and the data of the plane and facility system of the small clinic. As a result of the study, it is found that regulations applicable to small and medium-sized clinics are insufficient. In addition, the simulation results show that the infectious disease virus is likely to spread to other patients in the hospital.

A Study for Establishment of High Dose Radioiodine Therapy Patients' Release Standard

  • Park, Hoon-Hee;Kim, Hyun-Soo;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.153-156
    • /
    • 2011
  • This study, which is proceeded in the department of nuclear medicine, aims at preventing unnecessary radiation exposure to the patients and the people near the patients by understanding and presenting the realities about the isolating period for the high dose radioiodine patients after total thyroidectomy in the 7 general hospitals in metropolitan area. Theoretically, the physical half-life of the high dose radioiodine is 8 days. Radioiodine lower than 100 mCi usually is eliminated all in 2 days 1 night considering the biological half-life and the amount of excreting radioiodine The hospitalization standard of the patients treated with high-dose radioiodine therapy has been established according to the fact above. Investigation of the data and questionnaire from the hospital have proven that some hospitals didn't even measure the acceptable dose because of the faith in the vague data. Besides, the some of those inevitably let the readmitting patients exceeding the acceptable dose be in the general ward, not in the isolation ward, because the number of the isolation rooms is relatively smaller than the patients. Thus, we want to contribute that patients understand the realities and the hospitals consider the relevant problem actively so that the problem will be settled by this journal.

  • PDF

Implementation of A Hospital Information System in Ubiquitous and Mobile Environment

  • Jang, Jae-Hyuk;Sim, Gab-Sig
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.12
    • /
    • pp.53-59
    • /
    • 2015
  • In this paper, we developed a Hospital Information System in which the business process is formalized and a wire/wireless integrated solution is used. This system consists of the administration office program, the medical office program, the ward management program and the rounds management program. The administration office program can enroll and accept patients, issue and reissue the RFID card. The medical office program inputs a medical examination and treatment, outputs a diagnosis, requests a hospitalization, retrieves the record of a medical examination and treatment, assigns the corresponding examination room to the accepted patients, and updates the number of an waiting patient and a patient number according to the examination room on real time. The ward management program handles hospitalizations and leaving hospital, a nurse's note, and an isolation ward monitoring. The rounds management program handles a medical examination and treatment, and a leaving hospital using PDA. This developed system can be built at low cost and increase the quality of the medical services highly by making it automated the medical administration automation. Also the small number of the medical staffs can manage the inpatients efficiently by using the monitoring functions.

The Effect on COVID-19 Infection Control Practice of Nurses who Work in Working Sites with Negative Pressure Isolation Rooms (음압격리병실이 있는 부서에서 근무하는 간호사의 코로나19 감염관리 수행에 영향을 미치는 요인)

  • Park, Min Ji;Lee, Yun Mi
    • Journal of Korean Critical Care Nursing
    • /
    • v.15 no.1
    • /
    • pp.35-46
    • /
    • 2022
  • Purpose : This study aimed to identify the factors affecting coronavirus disease 2019 (COVID-19) infection control practices of nurses in negative pressure isolation rooms. Methods : The participants were 150 nurses working in three hospitals with negative pressure isolation rooms. Data were collected using structured questionnaires and analyzed using an independent t-test, one-way ANOVA, Scheffé test, Pearson correlation coefficients, and multiple regression analysis using the SPSS/WIN 26.0 program. Results : Factors significantly influencing the subject's COVID-19 infection control practice include Being married (𝛽=.18, p =.016), working in a ward with negative pressure isolation rooms (𝛽=.44, p <.001), working in an ICU with negative pressure isolation rooms (𝛽=.27, p =.010), COVID-19 infection control attitude (𝛽=.28, p =.001), anxiety for COVID-19 (𝛽=.30, p <.001). The explanatory power of these variables for COVID-19 infection control practice was 24.6% (F=8.67, p <.001). Conclusion : It is expected that strategies that utilize positive attitudes which believe that COVID-19 disease may be overcome by COVID-19 infection control practice will help improve emerging infectious diseases infection control practice.

Measurement and Analysis of Indoor Environment in Emergency Switching Type Temporary Negative Pressure Isolation Ward that Use Portable Negative Pressure Units (이동형 음압기를 적용한 긴급 전환형 임시음압격리병실의 실내 환경 측정 분석)

  • Lee, Wonseok;Lee, Sejin;Kim, Heegang;Yeo, Myoungsouk
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.89-97
    • /
    • 2022
  • Purpose: Because of the recent COVID-19 pandemic, there have been many cases of using portable negative pressure unit to convert general wards into temporary negative pressure isolation wards. The purpose of this study is to analyze the indoor environment of the switching type wards. Methods: Field measurements and experiments were conducted in a medical facility. Air volume, wind speed and pressure difference were measured in non-occupant state. Dispersion tests were performed with gas and particle matter. Results: The pressure difference between the wards and the corridor was higher than -2.5 Pa in normal situation. However, in the gas and particle dispersion tests, it was found that there were concerns about the spread through leakages in low-airtight walls or ceilings. In addition, it was confirmed that the pressure imbalance in ducts through the non-sealed diffusers could cause back flow during portable unit operation. Furthermore, when there was a pressure difference between adjacent wards planned to be at same pressure level, the possibility of the spread through the leakages was found. Implications: When using portable units for making switching type wards, it is necessary to create airtight space and seal the non-operation diffusers. In case of operating the air handling unit, T.A.B must be performed to adjust the duct balancing.

Patient Management to Improve the Efficiency of Infectious U-MAS System Design (전염성 환자관리의 효율성을 개선하기 위한 U-MAS 시스템 설계)

  • Shin, Yoon-Hwan;Shin, Ye-Ho;Ryu, Keun-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.9
    • /
    • pp.75-84
    • /
    • 2009
  • In this paper, the EPC Network as the most important technologies in the field of applied technology research and special attention to the use of RFID to better manage the disease in infected U-MAS (U-Medical Administrative Services) system was designed. U-MAS system, the Center for Disease Control in the illness, depending on the type of isolate and treat infected patients, recovery, discharge, isolation wards and intensive italian to manage and increase efficiency, manual and use a simple computer program improve the qualify of the current level, using RFID tags to improve the management of the patient everything that a little more and be out of the isolation ward, if competent disease management districts, such as the location to respond more quickly to facilitate the purpose is to contribute to. First, EPC Network and related technology for mobile RFID systems and related technology research. U-MAS system design offers. If you take advantage of the proposed U-MAS system for monitoring infectious disease patients and patients in the isolation ward, when the unauthorized departure location to shorten the time it takes to improve the effectiveness of disease management and present the elected effects was.

Staphylococcus Species in the Dental and Medical Environment

  • Han, Seung-Ho;Kim, Shin-Moo;Jeong, Seung-Il;Kim, Kang-Ju
    • International Journal of Oral Biology
    • /
    • v.38 no.1
    • /
    • pp.1-4
    • /
    • 2013
  • Staphylococcus species are one of prevalent pathogens found in hospitals. Microbes that are a primary cause of nosocomial infection were isolated from a dental and medical environment it may assist the reader to explain what this is and how it differs from the 'dental health care providers and ward health care providers'. To investigate the distribution of staphylococcus species in this environment, we used vitek II to measure drug sensitivity, and further performed biochemical testing. The isolation rate of staphylococcus species from the dental and medical environment was 100% but from dental health care providers and ward health care providers were 44.4% and 33.3%, respectively. In the analyses, staphylococcus species showed resistance to diffusion of cefoxitin and oxacillin discs. These staphylococci may be sufficiently positive for the mecA gene. Our results suggest that staphylococci might be an important cause of nosocomial infection in the dental clinic.

Comparison of Standards for healthcare Facilities and Environmental Investigation to Analyze Guidelines and Current Status of Healthcare Facilities (의료시설 관련 기준 비교와 환경 조사를 통한 의료시설 지침 및 현황 분석)

  • Jo, Yelim;Kim, Gihoon;Sung, Minki
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.51-60
    • /
    • 2022
  • Purpose: This study aims to analyze and supplement the standards related to healthcare facilities, negative pressure isolation wards, and emergency treatment facilities. In addition, through environmental investigations, analysis of emergency remodeling cases centered on the structural and HVAC characteristics of healthcare facilities is conducted. Methods: Domestic and foreign standards related to healthcare facilities were analyzed. Field investigations and architectural drawing analysis of general and emergency treatment facilities were conducted. Results: Healthcare facilities have different space classifications and air conditioning methods depending on the site situation. Emergency treatment facilities are classified into cases where the HVAC system is remodeled and portable negative pressure unit is installed, and some facilities did not meet the standards for differential pressure and air change rate. Implications: When developing emergency remodeling technology, remodeling and safety evaluation guidelines, it is considered possible to propose clearer guidelines for emergency remodeling treatment facilities for infectious diseases in Korea by referring to the results of this study.