• Title/Summary/Keyword: Isolation unit

Search Result 231, Processing Time 0.027 seconds

Isolation of Pigment Overproducing Mutant from Monascus purpureus and Optimization of Pigment Production (Monascus purpureus로부터 다량의 색소생성 변이주의 분리 및 색소생성의 최적조건)

  • Park Chi Duck;Jung Hyuck Jun;Yu Tae Shick
    • Korean Journal of Microbiology
    • /
    • v.41 no.2
    • /
    • pp.130-134
    • /
    • 2005
  • Isolation of a pigment overproducing mutant, P-57, by ultraviolet irradiation of Monascus purpureus KCCM 60016 and investigation of the optimal conditions for pigment production of the mutant were carried out. P-57 mutant produced pigment on solid state culture. Unpolished rice was the best cereal source for pigment production among eight kinds of tested cereal sources for the solid culture of the mutant. The optimal culture condition for pigment production were obtained from the cultivated at $30^{\circ}C,\;90\%$ humidity for 30 days. The P-57 mutant strain showed the best pigment productivity of 160.0 unit at red pigment, 193.6 unit at orange pigment, and 141.6 unit at yellow pigment on solid state culture under optimal condition.

Improving the Infection and Isolation Alarm Program: a Case Study (감염 및 격리 알람 프로그램 개선: 사례 연구)

  • Min-Ju Nam;Young-Sook Moon;Hee-Ok Kim;Minsu Ock
    • Quality Improvement in Health Care
    • /
    • v.28 no.2
    • /
    • pp.39-49
    • /
    • 2022
  • Purpose:The infection and isolation program used at a university hospital in A city was assessed and improved to provide medical staff with easy-to-understand information on isolation precautions and infectious diseases. Methods: Based on the results of the root cause analysis, the infection and isolation alarm computer program was improved. Subsequently, a survey was conducted with infection control leaders and unit managers (n=98) within the department to evaluate the degree of improvement. Results: The isolation registration and release procedures were simplified and unified to prevent confusion among the relevant departments. Additionally, the screen composition was improved so that various information related to infection can be easily accessed. After improvement in the program, the rate of isolation registration (53.0% to 100.0%, p<.001) and user satisfaction (67.6% to 92.2%) improved. Conclusion: This study will help improve the program so that other medical institutions can comply with the isolation precautions in accordance with the type of infections.

Nurses' experiences of caring for severe COVID-19 patients (COVID-19 중환자를 돌보는 간호사들의 경험)

  • Kang, Myoung Mi;Park, Ye Na;Park, Seong Young;Kim, Ju Hyun
    • Journal of Korean Critical Care Nursing
    • /
    • v.15 no.2
    • /
    • pp.14-26
    • /
    • 2022
  • Purpose : This study aimed to understand and describe the nurses' experiences caring for severe COVID-19 patients at isolation room with negative pressure in South Korea. Methods : Data were collected through individual in-depth interviews from February 16 to March 31, 2021 with 11 nurses who had been caring for severe COVID-19 patients at isolation room. Verbatim transcripts were analyzed according to Colaizzi's phenomenological analysis. Results : As a result, 5 theme clusters were extracted about nurses' experiences. The 5 theme clusters, "Adapting to unexpected adversity", "Accepting unresonable and heavy work", "Dulness and disconnection from the outside world", "Changing in perception of new infectious diseases", and "Pathetic isolated patients" emerged. Conclusion : The results of this study provided a deeper understanding of nurses struggling to care for COVID-19 severe patients. This study is expected to be useful in providing basic evidence for improving intensive care practices and for preparing policies in other infection disease situations.

Measurement and Analysis of Indoor Environment in Emergency Switching Type Temporary Negative Pressure Isolation Ward that Use Portable Negative Pressure Units (이동형 음압기를 적용한 긴급 전환형 임시음압격리병실의 실내 환경 측정 분석)

  • Lee, Wonseok;Lee, Sejin;Kim, Heegang;Yeo, Myoungsouk
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.4
    • /
    • pp.89-97
    • /
    • 2022
  • Purpose: Because of the recent COVID-19 pandemic, there have been many cases of using portable negative pressure unit to convert general wards into temporary negative pressure isolation wards. The purpose of this study is to analyze the indoor environment of the switching type wards. Methods: Field measurements and experiments were conducted in a medical facility. Air volume, wind speed and pressure difference were measured in non-occupant state. Dispersion tests were performed with gas and particle matter. Results: The pressure difference between the wards and the corridor was higher than -2.5 Pa in normal situation. However, in the gas and particle dispersion tests, it was found that there were concerns about the spread through leakages in low-airtight walls or ceilings. In addition, it was confirmed that the pressure imbalance in ducts through the non-sealed diffusers could cause back flow during portable unit operation. Furthermore, when there was a pressure difference between adjacent wards planned to be at same pressure level, the possibility of the spread through the leakages was found. Implications: When using portable units for making switching type wards, it is necessary to create airtight space and seal the non-operation diffusers. In case of operating the air handling unit, T.A.B must be performed to adjust the duct balancing.

A Study on the Room Conversion Type when Converting a Patient Bed-Room into a Negative Pressure Isolation Room - Focused on Nationally designated Isolation Wards and Urgent Isolation Wards (일반병실을 음압격리병실로 전환 시 병실 전환 방식에 관한 연구 - 국가지정입원치료병상과 긴급치료병상을 중심으로)

  • Kim, Jiyoon;Lee, Hyunjin;Kwon, Soonjung
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.4
    • /
    • pp.29-35
    • /
    • 2023
  • Purpose: The 2015 Middle East Respiratory Syndrome (MERS) outbreak and the recent COVID-19 pandemic have highlighted the lack of negative pressure isolation rooms and the fragility of the healthcare system. The need for healthcare facility transformation for respiratory infectious diseases has become more prominent due to COVID-19, and the purpose of this study is to provide a foundation for the rapid, economical, and safe construction of negative pressure isolation wards. Methods: This study analyzes the current status of hospitals that have been converted to negative pressure isolation rooms, and provides architectural plans and examples to provide a reference for bedroom change. Research data of this study have been obtained by analyzing the drawings of negative pressure isolation wards of nationally designated inpatient treatment beds and urgent isolation beds. In addition, the relevant literature of urgent isolation beds has been analyzed to derive bedroom change type. Result: In this study, a total of 21 isolation bed conversion methods have been presented. Implications: In order to change efficiently from a general ward to an isolation ward, it is necessary to consider the actual hospital's infectious disease transmission patterns and facility conditions.

Isolation Enhancement between Two Dual-Band Microstrip Patch Antennas Using EBG Structure without Common Ground Plane (독립된 접지면을 갖는 EBG 구조를 이용한 이중 대역 마이크로스트립 패치 안테나 사이의 격리도 향상)

  • Choi, Won-Sang;Lee, Hong-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.3
    • /
    • pp.306-313
    • /
    • 2012
  • In order to enhance the isolation level between two dual-band E-slot microstrip patch antennas, EBG structure which operates in UMTS Tx(1.92~1.98 GHz) and Rx(2.11~2.17 GHz) band is proposed. The proposed EBG structure made with a periodic array of two different size EBG unit cells which has a modified mushroom-type for isolation improvement between two antennas. They do not share a common ground plane of the microstrip patch antenna. Overall size of the fabricated antenna is $210.5mm{\times}117mm$. The two different EBG unit cell sizes are $15.6mm{\times}4mm$ and $17.4mm{\times}4mm$, respectively. It was etched on the FR-4 substrate(thickness=3.93 mm, ${\varepsilon}_r$=4.6). The experiment results show that the isolation level between antennas in Tx/Rx band were improved by about 9 dB and 12 dB, respectively, through the use of the proposed EBG structure.

Architectural Planning Study on Spatial Composition of Mobile Seclusion Module - Based on Modular Construction System (이동형 안정실 모듈의 공간구성에 대한 건축계획적 연구 - 모듈러 건축 공법을 기반으로)

  • Kim, Sung Hyun;Yang, Nae-won
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.2
    • /
    • pp.49-60
    • /
    • 2023
  • Purpose: This study aims to establish detailed spatial planning by identifying the needs for a seclusion module for emergency psychiatric patients. Methods: The necessity of medical space with seclusion function was analyzed from spatial, medical, and social perspectives. The needs for a space capable of performing three medical functions: protection, isolation, and treatment, was analyzed. Among various types of mobile medical facilities, seclusion space was considered suitable for utilizing modular construction methods, as it is the most rational method that can satisfy the environmental level of fixed healthcare facilities' space. Therefore, seclusion modules based on modular construction were planned, consisting of two protective units for stabilizing patients with psychiatric illness, one for treatment unit that can accommodate both internal and external treatment, and another one for an infectious disease isolation unit equipped with negative pressure equipment. Implications: This study analyzed the necessary medical functions of the interior space of the mobile stabilization module based on the spatial analysis of existing medical facilities, and proposed alternative spatial configurations according to treatment, seclusion, isolation functions.

An Instrument Fault Diagnosis Scheme for Direct Torque Controlled Induction Motor Driven Servo Systems (직접토크제어 유도전동기 구동 서보시스템을 위한 장치고장 진단 기법)

  • Lee, Kee-Sang;Ryu , Ji-Su
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.6
    • /
    • pp.241-251
    • /
    • 2002
  • The effect of sensor faults in direct torque control(DTC) based induction motor drives is analyzed and a new Instrument fault detection isolation scheme(IFDIS) is proposed. The proposed IFDIS, which operated in real-time, detects and isolates the incipient fault(s) of speed sensor and current sensors that provide the feedback information. The scheme consists of an adaptive gain scheduling observer as a residual generator and a special sequential test logic unit. The observer provides not only the estimate of stator flux, a key variable in DTC system, but also the estimates of stator current and rotor speed that are useful for fault detection. With the test logic, the IFDIS has the functionality of fault isolation that only multiple estimator based IFDIS schemes can have. Simulation results for various type of sensor faults show the detection and isolation performance of the IFDIS and the applicability of this scheme to fault tolerant control system design.

A TX Leakage Canceller using Micro Controller (마이크로 컨트롤러를 이용한 TX Leakage Canceller)

  • Park, Kyong-Tae;Jung, Jin-Woo;Roh, Hyoung-Hwan;Park, Jun-Seok;Kim, Hyeong-Seok
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.93-96
    • /
    • 2008
  • A transmitter (TX) leakage cancellation scheme using a Micro Controller Unit (MCU) is introduced. This paper highlights an adaptive anti-leakage signal generation via an MCU, which plays the key role in reducing the TX leakage signal level. High transmitter-to-receiver (TX-to-RX) isolation is verified with measurement results.

  • PDF