• 제목/요약/키워드: Islanding Detection

검색결과 98건 처리시간 0.033초

디지털 위상검출기법을 적용한 능동적 주파수 변화 정궤환기법 (Active Frequency Drift Positive Feedback Method for Anti-islanding using Digital Phase-Locked-Loop)

  • 이기옥;정영석;최주엽;최익;송승호;고문주
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.37-44
    • /
    • 2007
  • As photovoltaic(PV) power generation system becomes more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive power of the load and PV system are closely matched, islanding detection by Passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

향상된 고조파 검출 능력을 갖는 계통연계 인버터의 하이브리드 단독운전 방지기법 (A Hybrid Anti-islanding Detection Scheme for Utility Interactive Inverter with Enhanced Harmonic Extraction Capability)

  • 강성욱;김경화
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.312-319
    • /
    • 2014
  • When distributed generation such as a wind power system is connected to the grid, it should meet grid requirements like IEEE Std. 1547, which regulates the anti-islanding method. Since the islanding may cause damage on electrical equipments or safety hazards for utility line worker, a distributed generation should detect it as soon as possible. This paper proposes a hybrid anti-islanding method coupled with the active and passive detection methods. To enhance the harmonic extraction capability for an active harmonic injection method, cascaded second-order band-pass filter and signal processing scheme are employed. Simulation and experiments are carried out under the islanding test condition specified in IEEE Std. 1547. Passive over/under voltage and over/under frequency methods are combined with the active method to improve the detection speed under certain condition. The simulation and experimental results are presented to verify that the proposed hybrid anti-islanding method can effectively detect the islanding.

사고위치를 고려한 분산전원의 단독운전 상태 검출에 관한 연구 (A Study on Islanding Detection of Distributed Generation Considering Fault Location)

  • 정승복;김재철
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.118-123
    • /
    • 2004
  • 분산전원의 단독운전 검출에 관한 기존의 연구들은 사고위치에 따른 다양한 상황을 고려하지 않고 조건들만 만족되면 분산전원측을 무조건 분리시켰다. 하지만 분산전원이 연계되어 있지 않은 인근선로사고의 경우에는 인근선로측 보호기기의 동작으로 전원 측으로부터 정상적인 전원이 공급되기 때문에 분산전원을 분리시킬 필요가 없다. 또한 연계선로 사고의 경우일지라도 분산전원이 즉시 분리돼야 하는 경우인지, 단독운전인지, 정상운전의 경우인지 과부하차단에 의한 보호기기 동작의 경우인지를 고려해야 한다. 본 논문에서는 이러한 고려사항들을 계통의 전력상태 변화를 통해 구분하고 단독운전 시 및 분산전원을 분리해야 되는 상황을 찾아서 분산전원을 분리시키는 단독운전 상태 검출 알고리즘을 제안하였다. 고립운전 상태 검출 알고리즘을 검증하기 위하여 PSCAD/EMTDC를 이용하여 사례별로 시뮬레이션을 수행하였다.

태양광발전 시스템의 단독운전법 비교 (Comparision for Islanding Method of Grid-connected PV System)

  • 은석준;최종우;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.92-96
    • /
    • 2004
  • Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and active powers of RLC load and PV system are closely matched, islanding detection by passive methods becomes difficult. Active methods enables islanding detection by forcing the frequency of the voltage in the island to drift up/down. This paper shows the simulation and comparision by Matlab for the active methods.

  • PDF

단독운전검출을 위한 능동적 주파수 변화 정궤환기법 (Active Frequency Drift Positive Feedback Method for Anti-islanding)

  • 소정훈;정영석;유권종;유병규;이기옥;최주엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1684-1686
    • /
    • 2005
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive power of load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop(DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment in IEEE Std 929-2000 islanding test.

  • PDF

계통 연계형 PV 시스템의 고립운전 검출기법의 성능개선 (Performance Improvement of Islanding Detection Technique in Photo-Voltaic System)

  • 최철훈;최종우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.378-379
    • /
    • 2011
  • PV system's islanding occurs when the uitilty grid is removed but local sources continue to operate and provide power to local loads. Islanding is one of the serious problems in an electric power system connected with dispersed power sources. Also, this can present safety hazards and the possibility of damage to other electric equipments. If the real and reactive power of RLC load and PV system are closely matched, islanding detection by passive methods becomes difficult. Novel islanding detection method is proposed for grid-connected PV system.

  • PDF

계통연계형 PV 시스템의 주파수 변동에 의한 새로운 단독운전 검출기법 (Novel Islanding Detection Method using Frequency Drift for Grid-connected PV System)

  • 은석준;최종우;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 추계학술대회 논문집
    • /
    • pp.133-137
    • /
    • 2004
  • PV system's islanding occurs when the uitilty grid is removed but local sources continue to operate and provide power to local loads. Islanding is one of the serious problems m an electric power system connected with dispersed power sources. Also, this can present safety hazards and the possibility of damage to other electric equipments. If the real and reactive power of RLC load and PV system are closely matched, islanding detection by passive methods becomes difficult. Novel islanding detection method using frequency drift is proposed for grid-connected PV system.

  • PDF

연계점에서의 복소전력을 이용한 단독운전 판단기법 (Islanding Detection Based on Complex Power at the Intertie)

  • 강용철;차선희;장성일;강해권;김용균;박군철
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2167-2172
    • /
    • 2008
  • A large scale embedded generator or a micro-grid is usually interconnected to the grid through the dedicated line. Immediately after the removal of the grid supply, it must be disconnected and remain disconnected until the normal grid supplies are restored. This paper proposes an islanding detection algorithm based on complex power at the intertie. Complex power at the intertie delivered to the grid has a value depending on power flow during normal operation. When loss of mains occurs, complex power at the intertie moves to a value depending on the parameters of the dedicated line. The performance of the proposed algorithm was investigated under various operating and fault conditions. The proposed algorithm can detect an islanding operation even if no power is exchanged prior to loss of mains and discriminate the fault condition from islanding.

Islanding Prevention Method for Photovoltaic System by Harmonic Injection Synchronized with Exciting Current Harmonics of Pole Transformer

  • Yoshida, Yoshiaki;Fujiwara, Koji;Ishihara, Yoshiyuki;Suzuki, Hirokazu
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권3호
    • /
    • pp.331-338
    • /
    • 2014
  • When large penetration of the distributed generators (DGs) such as photovoltaic (PV) systems is growing up in grid system, it is important to quickly prevent islanding caused by power system fault to ensure electrical safety. We propose a novel active method for islanding prevention by harmonic injection synchronized with the exciting current harmonics of the pole transformer to avoid mutual interference between active signals. We confirm the validity of the proposed method by performing the basic tests of islanding by using a current source superimposed the harmonic active signal. Further, we carry out the simulation using PSCAD/EMTDC, and verify the fast islanding detection.

A Study of Islanding Detection of Grid-connected Three-phase Photovoltaic Power Conditioning System

  • Jung Y.S.;Yu G.J.;Choi J.Y.;Choi J.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.761-764
    • /
    • 2003
  • Islanding phenomenon of a grid-connected photovoltaic (PV) power conditioning system (PCS) is said to occur if the PCS continues to power a section of the utility system after that section has been disconnected from the utility source. Since islanding creates hazards for personnel and equipment, PCSs are required to detect and prevent Et. In this paper, several islanding detection methods (IDMs) and reactive power variation method are described. Islanding test results for 9kW PCS are presented for verification.

  • PDF