• Title/Summary/Keyword: Islanding

Search Result 189, Processing Time 0.026 seconds

Performance Analysis for the UPQC(Unified Power Quality Conditioner) Interconnected to the Distributed Generation System (분산전원 연계형 UPQC(Unified Power Quality Conditioner)의 성능해석)

  • 김희중;배병열;한병문
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.152-160
    • /
    • 2004
  • A novel UPQC(Unified Power Quality Conditioner), which consists of series inverter, shunt inverter, distributed generation system, is proposed. The proposing system can compensate reactive power, harmonics, voltage sag and swell, voltage interruption etc. through the change of paralleling operation mode and islanding operation mode. The control strategy for the proposing system was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the PSCAD/EMTDC simulation and the experimental work with the hardware prototype. The proposing system has the ultimate capability of improving power quality at the point of installation on power distribution systems or Industrial power systems and can be utilized for the custom power device in th future distribution system.

RPV Anti-islanding Method Using DPLL (DPLL을 이용한 무효전력변동 단독운전기법)

  • Yu, B.G.;Lee, K.O.;Yu, G.J.;Choi, J.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.308-310
    • /
    • 2008
  • 향후 가까운 미래에 정부에서 주도하고 있는 10만호 보급사업 등을 포함한 대규모 태양광발전산업의 보급에 따라 특정지역에서는 계통연계형 태양광 전력변환기(PV PCS)의 고밀도 연계가 예상된다. 이 때 지금까지는 이론적으로만 가능할 것으로 여겨졌던 현상 인 단독운전 현상이 발생할 수 있는 확률이 높아지게 된다. 본 논문에서는 전력변동기법 중 하나인 무효전력변동기법에 대하여 단독운전검출 성능을 향상시키기 위한 한 방법으로 Digital Phase-Locked-Loop(DPLL)의 주파수계산을 이용하여 그 효용성을 PSIM 시뮬레이션을 통하여 검증하였다.

  • PDF

A Novel Anti-islanding Method of a Grid-connected Inverter for a PMSG-based Wind Power Generation System (PMSG 기반 풍력발전 시스템 계통연계 인버터의 새로운 단독운전방지 기법)

  • Kang, Sung-Wook;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.427-428
    • /
    • 2013
  • 풍력발전과 같은 분산전원이 계통에 연계되어 운전될 경우, 계통연계 규정에 따라 운전해야 한다. 특히 계통사고에 의해 계통과 분리되었음에도 불구하고, 지속적으로 운전하는 것을 단독운전 이라 한다. 이러한 단독운전은 전기설비의 손상을 일으킬 수 있으므로 계통연계 규정에 따라 이를 빠르고 정확하게 검출하여야 한다. 본 논문에서는 이러한 단독운전을 검출하기 위해서 NDZ(Non-Detecton Zone)를 갖지 않는 고조파 주입 기법의 새로운 고조파 계산 및 검출 알고리즘 제안한다.

  • PDF

Control Strategy for Hybrid Module with Energy Storage for Island Mode (에너지 저장 장치를 갖는 태양광 하이브리드 모듈의 제어 전략)

  • Choi, Bong-Yeon;Jang, Jin-Woo;Lee, Soon-Ryung;Kim, Young-Ho;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.477-478
    • /
    • 2013
  • This paper presents the control mehtod of a photovoltaic(PV) hybrid generation with energy storage system(ESS). To stabilize power control between PV generation system with ESS and local load, the proposed control method performs grid-connected and islanding operations. Through the simulation results the theoretical analysis of proposed method is verified.

  • PDF

Evaluation the Non-Detection Zone of Anti-Islanding Methods (단독운전검출기법의 불검출 영역에 대한 비교 고찰)

  • Lee K.O;So J.H;Jung Y.S;Yu G.J;Choi J.Y;Jung S.G;Choy I.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1480-1482
    • /
    • 2004
  • 계통연계형 태양광발전 시스템의 확대보급에 따라 단독운전 검출기법의 검출 성능에 대한 검증의 필요성이 대두되고 있다. 본 논문에서는 단독운전검출기법의 대표적인 능동적 검출기법인 무효전력변동기법 (reactive power variation method)과 주파수 쉬프트기법(active frequency drift method)을 IEEE Std 929-2000에서 명시된 단독운전검출 시험방법을 이용하여 단독운전검출기법의 성능 및 불검출 영역(non-detection zone)에 대하여 비교 분석하였다.

  • PDF

Wireless Paralleled Control Strategy of Three-phase Inverter Modules for Islanding Distributed Generation Systems

  • Guo, Zhiqiang;Sha, Deshang;Liao, Xiaozhong
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.479-486
    • /
    • 2013
  • This paper presents a control strategy for distributed systems, which can be used in islanded microgrids. The control strategy is based on the droop method, which uses locally measured feedback to achieve load current sharing. Instead of the traditional droop method, an improved one is implemented. A virtual inductor in the synchronous frame for three-phase inverters is proposed to deal with the coupling of the frequency and the amplitude related to the active and reactive power. Compared with the traditional virtual inductor, the proposed virtual inductor is not affected by high frequency noises because it avoids differential calculations. A model is given for the distributed generation system, which is beneficial for the design of the droop coefficients and the value of the virtual inductor. The effectiveness of the proposed control strategy is verified by simulation and experiment results.

The New Modeling of Solar Cell for Virtual Implement Of Solar Cell (태양전지 가상구현 장치를 위한 새로운 태양전지 모델링에 관한 연구)

  • Lee B. I.;Ryu T. G.;Han J. M.;Choe G. H.
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.69-73
    • /
    • 2002
  • A study on photovoltaic system has a lot of problems. Such as repetition experiment in the same condition, development of MPPT(Maximum Power Point Tracking) algorithm, development of islanding detection algorithm and so forth. The reason Is that solar cell output characteristics are varied by insolarion and surface temperature of solar cell. Therefore, the assistance equipment is required which emulates the solar cell characteristics. In this paper, propose the new modeling of solar cell and verify this modeling using MATLAB simulation. And experiment virtual implement of solar cell system using this modeling.

  • PDF

New Adaptive Linear Combination Structure for Tracking/Estimating Phasor and Frequency of Power System

  • Wattanasakpubal, Choowong;Bunyagul, Teratum
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.28-35
    • /
    • 2010
  • This paper presents new Adaptive Linear Combination Structure (ADALINE) for tracking/estimating voltage-current phasor and frequency of power system. To estimate the phasors and frequency from sampled data, the algorithm assumes that orthogonal coefficients and speed of angular frequency of power system are unknown parameters. With adequate sampled data, the estimation problem can be considered as a linear weighted least squares (LMS) problem. In addition to determining the phasors (orthogonal coefficients), the procedure estimates the power system frequency. The main algorithm is verified through a computer simulation and data from field. The proposed algorithm is tested with transient and dynamic behaviors during power swing, a step change of frequency upon islanding of small generators and disconnection of load. The algorithm shows a very high accuracy, robustness, fast response time and adaptive performance over a wide range of frequency, from 10 to 2000 Hz.

Unit Commitment of a Microgrid Considering Islanded Operation Scenarios (독립운전 시나리오를 고려한 마이크로그리드의 최적 발전기 기동정지 계획)

  • Lee, Si Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.6
    • /
    • pp.708-714
    • /
    • 2018
  • Islanded operation of a microgrid can ensure the reliable operation of the system when a large accident occurs in the main grid. However, because the generation capability of a microgrid is typically limited, a microgrid operator should take islanded operation risk into account in scheduling its generation resources. To address this problem, in this paper we have proposed two unit commitment formulations based on the islanding scenario that reflect the expected and worst-case values of the islanded operation risk. An optimal resource scheduling strategy is obtained for the microgrid operator by solving these optimization problem, and the effectiveness of the proposed method is investigated by numerical simulations.

Frequency Shift Scheme with Positive-feedback for Anti-islanding of Grid-connected PVPCS Modeling and Analysis (계통 연계형 태양광 발전 시스템의 단독운전 방지를 위한 Positive-feedback을 가지는 주파수 변동 기법의 모델링 및 분석)

  • Jo, Yeong-Min;Choi, Ju-Yeop;Choy, Ick;Lee, Dong-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.225-226
    • /
    • 2014
  • 본 논문에서는 최악의 상황에서도 계통 연계형 태양광 발전 시스템에서의 단독운전 현상을 신속히 검출하여 시스템을 정지시킬 수 있게 하기 위해 Positive-feedback을 가지는 주파수 변동 기법에 대한 설계와 시뮬레이션을 바탕으로 단독운전 검출 성능 보장과 출력 전력의 품질 보장을 위한 제어기 설계 방법에 대하여 제시하고, 이를 시뮬레이션을 통해 타당성을 검증한다.

  • PDF