• Title/Summary/Keyword: Irradiation test

Search Result 689, Processing Time 0.026 seconds

Effects of Microwave Irradiation for Elutriated Acid Fermentation of Sewage Primary Sludge (하수 일차슬러지의 세정산발효 특성에 대한 Microwave 전처리의 영향)

  • Kwon, Koo-Ho;Lee, Won-Sic;Min, Kyung-Sok
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.498-503
    • /
    • 2007
  • The performance of elutriated acid fermentation to evaluate the effects of microwave irradiation and pH control as pretreatment was investigated. The MW pH 7 reactor which was used the pretreated primary sludge as microwave irradiation was operated at pH 7 and $35^{\circ}C$. The EAF pH 9 reactor was operated at pH 9 and $35^{\circ}C$ without pretreatment. The SCOD and VFAs production rate were 0.17 gSeOD/gVSrem. and 0.27 gVFAs as COD/gVSrem. in MW pH 7 reactor, 0.16 gSCOD/gVSrem. and 0.24 gVFAs as COD/gVSrem. in EAF pH 9 reactor, respectively. VS and Volume reduction were 54% and 48% in MW pH 7 reactor, 54.6% and 36% in EAF pH 9 reactor, respectively. A comparison of the microwave irradiation and controlled pH in elutriated acid fermentation showed that the former is more efficient in SCOD and VFAs production and it rises to slightly higher reduction in the volume of the sludge. In addition, E. coli. was not detected in the wasting sludge of MW pH 7 reactor. Based on the results, microwave irradiation appeared to be one of the viable options for generating class A sludge. According to the batch tests, sequencing batch test which was used the pretreated primary sludge as microwave was performed at pH 7 and $35^{\circ}C$, SCOD production was 0.16 gSCOD/gVSrem., VS reduction and volume reduction were 64% and 63%, respectively.

Comparison of inactivation and sensitivity of antibiotic resistance bacteria by ultrasound irradiation (초음파 조사에 의한 항생제 내성균 불활성화 및 감수성 변화)

  • Lee, Sunghoon;Nam, Seong-Nam;Oh, Jeill
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.3
    • /
    • pp.191-204
    • /
    • 2019
  • The 20-kHz ultrasonic irradiation was applied to investigate bacterial inactivation and antibiotic susceptibility changes over time. Applied intensities of ultrasound power were varied at 27.7 W and 39.1 W by changing the amplitude 20 to 40 to three bacteria species (Escherichia coli, Enterococcus faecalis, and Staphylococcus aureus). By 15-min irradiation, E. coli, a gram-negative bacterium, showed 1.2- to 1.6-log removals, while the gram-positive bacteria, Enterococcus faecalis and Staphylococcus aureus, showed below 0.5-log removal efficiencies. Antibiotic susceptibility of penicillin-family showed a dramatic increase at E. coli, but for other antibiotic families showed no significant changes in susceptibility. Gram-positive bacteria showed no significant differences in their antibiotic susceptibilities after ultrasound irradiation. Bacterial re-survival and antibiotic susceptibility changes were measured by incubating the ultrasound-irradiated samples. After 24-hour incubation, it was found that all of three bacteria were repropagated to the 2- to 3-log greater than the initial points, and antibiotic inhibition zones were reduced compared to ones of the initial points, meaning that antibiotic resistances were also recovered. Pearson correlations between bacterial inactivation and antibiotic susceptibility showed negative relation for gram-negative bacteria, E. coli., and no significant relations between bacterial re-survival and its inhibition zone. As a preliminary study, further researches are necessary to find practical and effective conditions to achieve bacteria inactivation.

The Effect of Elector Spine Muscle Tone Using Irradiation According to the Angular Motion of a Proprioceptive Neuromuscular Facilitation (PNF) Arm Pattern (PNF 팔 패턴의 각도 변화가 척추세움근의 근 긴장도 변화와 방산의 효과에 미치는 영향)

  • Yang, Jae-Man;Lee, Sang-Moo;Lee, Jung-Hoon
    • PNF and Movement
    • /
    • v.18 no.3
    • /
    • pp.435-444
    • /
    • 2020
  • Purpose: This study aimed to compare the elector spine muscle tone using the irradiation of the proprioceptive neuromuscular facilitation (PNF) arm pattern according to angular motion. Methods: Thirty subjects participated in this study. Elector spine muscle tone was measured using a Myotonpro device while in the sitting position according to the angular motion (70°, 100°, 130°) of the PNF arm pattern using a D1 flexion pattern. Each angular motion of the PNF arm pattern was performed with a continuous passive motion (CPM). The change in elector spine muscle tone was statistically evaluated using a repeated one-way ANOVA test. Post-hoc analysis was performed using the Bonferroni method. Results: The results revealed a significant change in elector spine muscle tone when performing the PNF arm pattern using D1 flexion pattern. Specifically, the elector spine muscle tone had significantly increased at 100° and 130° motion in the PNF arm pattern when compared to the initial muscle tone (p < 0.05). No significant muscle tone changes were noted for any of the angular motions of the PNF upper arm pattern (p > 0.05). Conclusion: The results of this study indicate a positive increase in elector spine muscle tone with irradiation of the PNF upper arm pattern exercise with 100° or 130° angular motion. The minimum angle at which the effect of the irradiation of the PNF arm pattern could be seen was 100°.

Direct Microwave Sintering of Poorly Coupled Ceramics in Electrochemical Devices

  • Amiri, Taghi;Etsell, Thomas H.;Sarkar, Partha
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.390-397
    • /
    • 2022
  • The use of microwaves as the energy source for synthesis and sintering of ceramics offers substantial advantages compared to conventional gas-fired and electric resistance furnaces. Benefits include much shorter processing times and reaching the sintering temperature more quickly, resulting in superior final product quality. Most oxide ceramics poorly interact with microwave irradiation at low temperatures; thus, a more complex setup including a susceptor is needed, which makes the whole process very complicated. This investigation pursued a new approach, which enabled us to use microwave irradiation directly in poorly coupled oxides. In many solid-state electrochemical devices, the support is either metal or can be reduced to metal. Metal powders in the support can act as an internal susceptor and heat the entire cell. Then sufficient interaction of microwave irradiation and ceramic material can occur as the sample temperature increases. This microwave heating and exothermic reaction of oxidation of the support can sinter the ceramic very efficiently without any external susceptor. In this study, yttria stabilized zirconia (YSZ) and a Ni-YSZ cermet support were used as an example. The cermet was used as the support, and a YSZ electrolyte was coated and sintered directly using microwave irradiation without the use of any susceptor. The results were compared to a similar cell prepared using a conventional electric furnace. The leakage test and full cell power measurement results revealed a fully leak-free electrolyte. Scanning electron microscopy and density measurements show that microwave sintered samples have lower open porosity in the electrode support than conventional heat treatment. This technique offers an efficient way to directly use microwave irradiation to sinter thin film ceramics without a susceptor.

In vitro Test of Mycelial Growth Inhibition of 5 Fungi Pathogenic to Strawberries by Ultraviolet-C (UV-C) Irradiation (자외선(UV-C) 조사에 의한 딸기병원균의 균사생장억제)

  • Kim, Seon Ae;Ahn, Soon-Young;Oh, Wook;Yun, Hae Keun
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.634-637
    • /
    • 2012
  • In strawberry production, among others, the high incidence of diseases by pathogenic fungi resulting in the reduction of fruit yield and quality requires the development of eco-friendly management systems rather than chemical sprays to control them. The diameter of colonies grown in media at $25^{\circ}C$ for 5 days was measured to evaluate the in vitro inhibition of mycelial growth of 5 pathogenic fungi by irradiation with ultraviolet (UV-C, 264 nm). The mycelial growth of 5 pathogenic fungi was inhibited in potato dextrose agar (PDA) by the irradiation of UV-C for 1 hour a day, and was dramatically inhibited by the irradiation of UV-C for 9-12 h a day. The irradiation of UV-C for 9-12 h a day inhibited completely the growth of the late blight pathogen, Phytophthora cactorum. The irradiation distance of 40 to 50 cm was effective for the inhibition of mycelial growth of fungi. The mycelial growth of fungi without pre-incubation was inhibited strongly by UV-C irradiation compared to fungi pre-incubated for 2 days without light. The mycelia growth of Colletotrichum gloeosprioides and Fusarium oxysporum was inhibited strongly by UV-C irradiation in vegetable 8 juice agar compared to PDA.

Screening of Sterilized Ramen Soup by DEFT/APC Method and Its Quality Properties as Affected by Irradiation (DEFT/APC 측정에 의한 시판 분말수프의 살균처리여부 확인 및 감마선 처리에 따른 품질특성 평가)

  • Ahn, Jae-Jun;Kim, Kwang-Hoon;Park, Sung-Hyun;Kwon, Joong-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.41 no.5
    • /
    • pp.515-521
    • /
    • 2009
  • The DEFT (direct epifluorescent filter technique)/APC (aerobic plate count) test was utilized to screen powdered Ramen soup samples (RS-1, RS-2) whether or not they have been microbial-decontaminated. The initial microbial loads of commercially-packaged samples were log DEFT 6.46 (RS-1) and 7.05 (RS-2), but the viable bacterial counts were log APC 2.74 (RS-1) and 1.95 (RS-2), respectively; this finding showed that they have been already decontaminated by methods other than irradiation. The same samples were then subjected to gamma irradiation at 0, 5 and 10 kGy in order to evaluate the microbial and physicochemical changes during post-irradiation storage for 6 months under room conditions ($10{\pm}3^{\circ}C$). The DEFT count was constant in irradiated samples even at different doses, but APC decreased with dose increases; this implies that the log DEFT/APC increased in a linear fashion with dose. No coliforms, yeasts and molds were detected in any of the samples, whereas the initially detected aerobic bacteria ($5.49{\times}10^2CFU/g$) were inactivated by 5 kGy or more and no growth was observed during the subsequent storage period. The pH of RS-1 was reduced by irradiation (p<0.01), but increased (p<0.01) with increasing storage time. Irradiation induced a reduction in volatile basic nitrogen (VBN), whereas an increase in thiobarbituric acid (TBA) values was observed. The storage time proved more influential than irradiation up to 10 kGy in terms of changes in the VBN and Hunter’s color values of powdered Ramen soups.

Swelling and Drug Release Characteristics of PVP Hydrogel Polymerized by $\gamma$-Irradiation Method (김마선 조사법으로 합성한 PVP하이드로겔의 팽윤과 약물방출특성)

  • 심창구;오정숙;신병철
    • YAKHAK HOEJI
    • /
    • v.37 no.5
    • /
    • pp.511-519
    • /
    • 1993
  • The short and variabke transit of drug throught GI tracj and the inter-and intra-subject variations of the transit restrict the sustained drug absorption after oral adminstration. These restrictions may be solved by retaining the dosage forms in the stomach. Then the dosage form will act as a platform which releases the drug slowly and makes the GI absorption occur for a long time. In this study, as the platforms, PVP hydrogels were synthesized by chemical and y-irradiation method in the cylindrical test tube. The chemical method means the synthesis of the hydrogel by heating the mixed solution of N-vinyl-2-pyrrolidone [monomer], acrylated albumin [crosslinking agent], 2, 2'-agobis(2-methylpropionitrile) [initiator] and proxyphylline [drug] at $65^{\circ}C$ for 5 hr. The $\gamma$-irradiation method means the synthesis of the hydrogel by irradiation with $^{60}$ Co $\gamma$-ray of the mixed solution of the monomer, acrylated albumin, and flurbiprofen [drug] at room temperature with total 0.2 Mrad for 3 hr. Our intention is to design the hydrogel tablet (diameter : 1.20 cm, thickness : 0.60 cm) which swells in the gastric fluid after oral administration to such a size that passing through the pylorus could be inhibited during the period of drug release. After releasing drug, the hydrogel should be degraded by the enzymeatic digestion in the stomach, or by hydrolysis and eventually solubilized. Thus, in votro tests were performed to examine the factors that affect swelling and drug release from the PVP hydrogels. Experimental results show that the hydrogels swell to a size larger than the diameter of the pylorus(l.3$\pm$0.7 cm) and the hydrogel prepared by the chemical method is digested by pepsin. But the hydrogel prepared by the $\gamma$-irradiation method was not digested by the pepsin and just collapsed with time. Thus, the swelling of the hydrogel synthesized by $\gamma$-irradiation was independent albumin acrylation time and pepsin concentration. But drug content and radiation dose affected the swelling and drug release kinetics of the hydrogel. Drug release from the hydrigels was prolonged up to about 24 hr. Therefore, it was concluded that by adjusting these factors, the albumin-crosslinked PVP hydrogel synthesized by $\gamma$-irradiation method is expected to be retained in the stomach for up to 60hr and be a potential platform of drugs for long-term GI absorption.

  • PDF

THE EFFECT OF IRRADIATION MODES ON POLYMERIZATION AND MICROLEAKAGE OF COMPOSITE RESIN (광조사 방식이 복합레진의 중합과 누출에 미치는 영향)

  • Park, Jong-Jin;Park, Jeong-Won;Park, Sung-Ho;Park, Ju-Myong;Kwon, Tae-Kyung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.2
    • /
    • pp.158-174
    • /
    • 2002
  • The aim of this study was to investigate the effect of light irradiation modes on polymerization shrinkage, degree of cure and microleakage of a composite resin. VIP$^{TM}$ (Bisco Dental Products, Schaumburg, IL, USA) and Optilux 501$^{TM}$ (Demetron/Kerr, Danbury, CT, USA) were used for curing Filtek$^{TM}$ Z-250 (3M Dental Products, St. Paul., MN, USA) composite resin using following irradiation modes: VIP$^{TM}$ (Bisco) 200mW/$\textrm{cm}^2$ (V2), 400mW/$\textrm{cm}^2$ (V4), 600mW/$\textrm{cm}^2$ (V6), Pulse-delay (200 mW/$\textrm{cm}^2$ 3 seconds, 5 minutes wait, 600mW/$\textrm{cm}^2$ 30seconds, VPD) and Optilux 501$^{TM}$ (Demetron/Kerr) C-mode (OC), R-mode (OR). Linear polymerization shrinkage of the composite specimens were measured using Linometer (R&B, Daejeon, Korea) for 90 seconds for V2, V4, V6, OC, OR groups and for up to 363 seconds for VPD group (n=10, each). Degree of conversion was measured using FTIR spectrometer (IFS 120 HR, Bruker Karlsruhe, Germany) at the bottom surface of 2 mm thick composite specimens V2, Y4, V6, OC groups were measured separately at five irradiation times (5, 10, 20, 40, 60 seconds) and OR, VPD groups were measured in the above mentioned irradiation modes (n=5 each). Microhardness was measured using Digital microhardness tester (FM7, Future-Tech Co., Tokyo, Japan) at the top and bottom surfaces of 2mm thick composite specimens after exposure to the same irradiation modes as the test of degree of conversion(n=3, each). For the microleakage test, class V cavities were prepared on the distal surface of the ninety extracted human third molars. The cavities were restored with one of the following irradiation modes : V2/60 seconds, V4/40 seconds, V6/30 seconds, VPD , OC and OR. Microleakage was assessed by dye penetration along enamel and dentin margins of cavities. Mean polymerization shrinkage, mean degree of conversion and mean microhardness values for all groups at each time were analyzed using one-way ANOVA and Duncan's multiple range test, and using chi-square test far microleakage values. The results were as follows : . Polymerization shrinkage was increased with higher light intensity in groups using VIP$^{TM}$ (Bisco) : the highest with 600mW/$\textrm{cm}^2$, followed by Pulse-delay, 400mW/$\textrm{cm}^2$ and 200mW/$\textrm{cm}^2$ groups, The degree of polymerization shrinkage was higher with Continuous mode than with Ramp mode in groups using Optilux 501$^{TM}$ (Demetron/Kerr). . Degree of conversion and microhardness values were higher with higher light intensity. The final degree of conversion was in the range of 44.7 to 54.98% and the final microhardness value in the range of 34.10 to 56.30. . Microleakage was greater in dentin margin than in enamel margin. Higher light intensity showed more microleakage in dentin margin in groups using VIP$^{TM}$ (Bisco). The microleakage was the lowest with Continuous mode in enamel margin and with Ramp mode in dentin margin when Optilux 501$^{TM}$ (Demetron/Kerr) was used.

High Heat Flux Test of Cu/SS Mock-up for ITER First Wall (ITER 일차벽의 Cu/SS Mock-up에 대한 고열부하 시험)

  • Lee, D.W.;Bae, Y.D.;Hong, B.G.;Lee, J.H.;Park, J.Y.;Jeong, Y.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.3
    • /
    • pp.325-330
    • /
    • 2006
  • In order to verify the integrity of the first wall (FW) of the International Thermonuclear Experimental Reactor (ITER), the fabricated Cu/SS mock-up is tested in the JAEA Electron Beam Irradiation Test Stand (JEBIS). To fabricate the Cu/SS mock-up, CuCrZr and 316L authentic stainless steel (SS316L) are used for Cu alloy and steel, respectively The hot isostatic pressing (HIP) is used as a manufacturing method with a $1050^{\circ}C$ and 150 MPa. The high heat flux (HHF) test is performed using an electron beam with a heat flux of $5MW/m^2$ and a cycle of 15-sec on time and 30-sec off time. The temperature measurement in the HHF test shows good agreement with the results obtained from ANSYS code analysis, which is used for determining the HHF test conditions.

A STUDY ON A COMPARISON BETWEEN IN-VIVO AND IN-VITRO PHOTOTOXICITY TEST (IN-VIVO와 IN-VITRO에서의 광독성 시험법의 비교에 대한 연구)

  • Lee, Ho;Koh, Jae-Sook;Park, Won-Jae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.19 no.1
    • /
    • pp.57-76
    • /
    • 1993
  • Phototoxicity is a complex phenomenon which may involve photochemical reaction and biological response mechanism. This complexicity and iii mal protecting tendency has led to the development of various in-vitro approaches as sensitive, alternative test to the in-vivo phototoxicity test. In this study, we investigated not only the sensitivity of two microorganism, (C. albicans and 5. typhimurium TA 98 about UV) but also a correlation between in-vitro and in-vivo phototoxicity test using UV A and 1 Furthermore, we studied the effect of irradiation method which were as follows 1) irradiate to material and microorganism, simultaneously 2) irradiate to only material 3) irradiate to material and microorganism, respectively In each irradiation method, it showed no significant difference, However we were able to observe the more sensitive phototoxicity in S. typhimurium TA 98 than C. albicans, and the results of in-vitro test using 5. typhimurium TA 98 had a good correlation with those of in-vivo test.

  • PDF