• 제목/요약/키워드: Irradiation Growth

검색결과 660건 처리시간 0.033초

Comparative Study of Toxic Effects of Anatase and Rutile Type Nanosized Titanium Dioxide Particles in vivo and in vitro

  • Numano, Takamasa;Xu, Jiegou;Futakuchi, Mitsuru;Fukamachi, Katsumi;Alexander, David B.;Furukawa, Fumio;Kanno, Jun;Hirose, Akihiko;Tsuda, Hiroyuki;Suzui, Masumi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권2호
    • /
    • pp.929-935
    • /
    • 2014
  • Two types of nanosized titanium dioxide, anatase ($anTiO_2$) and rutile ($rnTiO_2$), are widely used in industry, commercial products and biosystems. $TiO_2$ has been evaluated as a Group 2B carcinogen. Previous reports indicated that $anTiO_2$ is less toxic than $rnTiO_2$, however, under ultraviolet irradiation $anTiO_2$ is more toxic than $rnTiO_2$ in vitro because of differences in their crystal structures. In the present study, we compared the in vivo and in vitro toxic effects induced by $anTiO_2$ and $rnTiO_2$. Female SD rats were treated with $500{\mu}g/ml$ of $anTiO_2$ or $rnTiO_2$ suspensions by intra-pulmonary spraying 8 times over a two week period. In the lung, treatment with $anTiO_2$ or $rnTiO_2$ increased alveolar macrophage numbers and levels of 8-hydroxydeoxyguanosine (8-OHdG); these increases tended to be lower in the $anTiO_2$ treated group compared to the $rnTiO_2$ treated group. Expression of $MIP1{\alpha}$ mRNA and protein in lung tissues treated with $anTiO_2$ and $rnTiO_2$ was also significantly up-regulated, with $MIP1{\alpha}$ mRNA and protein expression significantly lower in the $anTiO_2$ group than in the $rnTiO_2$ group. In cell culture of primary alveolar macrophages (PAM) treated with $anTiO_2$ and $rnTiO_2$, expression of $MIP1{\alpha}$ mRNA in the PAM and protein in the culture media was significantly higher than in control cultures. Similarly to the in vivo results, $MIP1{\alpha}$ mRNA and protein expression was significantly lower in the $anTiO_2$ treated cultures compared to the $rnTiO_2$ treated cultures. Furthermore, conditioned cell culture media from PAM cultures treated with $anTiO_2$ had less effect on A549 cell proliferation compared to conditioned media from cultures treated with $rnTiO_2$. However, no significant difference was found in the toxicological effects on cell viability of ultra violet irradiated $anTiO_2$ and $rnTiO_2$. In conclusion, our results indicate that $anTiO_2$ is less potent in induction of alveolar macrophage infiltration, 8-OHdG and $MIP1{\alpha}$ expression in the lung, and growth stimulation of A549 cells in vitro than $rnTiO_2$.

들깻잎(Perilla frutescens)으로부터 U937 세포에 apoptosis를 유도하는 광과민성 물질의 분리 및 구조동정 (Isolation and Structure Identification of Photosensitizer from Perilla frutescens Leaves Which Induces Apoptosis in U937)

  • 하준영;김미경;이준영;최은비;홍창오;이병원;배창환;김근기
    • 생명과학회지
    • /
    • 제25권1호
    • /
    • pp.53-61
    • /
    • 2015
  • 본 연구에서 우리는 들깻잎(Perilla frutescens)으로부터 U937 세포에 대해 apoptosis를 유도하는 광과민성 물질을 분리하기 위해 연구를 시작하였다. 들깻잎은 한국의 대중적인 쌈채소로 바타민, GABA, 미네랄 등이 풍부하다고 알려져 있다. 건조한 들깻잎을 메탄올로 추출하여 다양한 크로마토그래피법을 이용하여 광과민성 물질을 순수 분리하였다. 순수 분리한 광과민성 물질을 PL9443으로 명명하고, 구조동정을 위하여 1D-NMR, 2D-NMR, FAB-mass spectroscopy 분석을 실시하였다. 순수 분리한 PL9443 compound의 흡광도를 측정한 결과 410 nm에서 최대 흡수를 보였고, 330, 410, 680 nm에서 흡수 peak를 나타내었다. PL9443 compound는 분자량 620.7의 pheophorbide a ethyl ester로 동정하였다. 구조동정한 물질은 porphyrin환을 갖는 구조에서 Mg이온이 탈리된 pheophorbide 유도체화합물이었다. PL9443 compound의 처리에 따른 U937 세포의 형태학적 변화를 관찰한 결과, 광조건에서 apoptosis의 전형적인 현상인 apoptotic body와 소낭구조물이 형성되는 것을 확인할 수 있었다. 또한 PL9443 compound를 0.08 nM로 처리하였을 때 99%의 caspase-3/7 activity가 나타났고, 세포손상 역시 광의존적으로 나타내는 것을 확인하였다. PL9443 compound를 처리하고 광을 조사한 처리구와 광을 조사하지 않은 처리구의 세포로부터 DNA를 분리하여 전기영동을 실시한 결과 광을 조사한 곳에서 DNA ladder현상을 관찰할 수 있었다. 따라서 PL9443 compound는 광의존적 apoptosis 유도에 의한 세포손상을 일으키는 것을 확인하였다.

선형가속기를 이용한 뇌종양 46예의 뇌정위다방향방사선치료 성적 (Clinical Report of 46 Intracranial Tumors with LINAC Based Stereotactic Radiosurgery)

  • 윤세철;서태석;김성환;강기문;김연실;최병옥;장홍석;최규호;김문찬;신경섭
    • Radiation Oncology Journal
    • /
    • 제11권2호
    • /
    • pp.241-247
    • /
    • 1993
  • 가톨릭 의과대학 강남성모병원 치료방사선과에서는 1988년 7월부터 1992년 12월 사이에 뇌종양 환자 45명의 뇌내 46개 병소에 대한 뇌정위다방향방사선치료를 실시하였으며, 이들에 대한 영상학적 및 임상적 추적조사 결과를 후향적으로 분석하였다. 뇌종양에 대한 뇌정위다방향방사선치료는 병소가 생명중추에 인접되어 있거나 다른 전신질환과 함께 있어 종양의 수술적 제거가 어려운 경우, 수술후 잔류 병소가 남아 있거나 재발된 경우, 또는 종래 부터 해오던 방사선치료에도 불구하고 잔류병소가 남아있거나 환자가 수술을 거부할 경우 등에서 실시하게 된다. 이는 수술이나 유사한 다른 치료와 비교하여 동일한 치료효과를 얻으면서도 간편하고 비침습적 이며 또한 상대적으로 저렴한 치료 경비가 소요됨으로, 최근 방사선치료장비 및 치료계획 프로그램의 개발과 함께 그 치료성적이 관심의 대상이 되고 있다. 환자 분포는 남녀 비가 22:33 이며, 연령 분포는 5-74세 (중앙값 : 43세)이었고, 추적조사 기간은 2-55개월 (중앙값 : 35개월)이었다. 6 MV 선형 가속기를 사용하여 조사야 용적은 $0.13-42.88\;cm^3$(중앙값 : $7.26\;cm^3)$이었으며, 최대치료선량은 5-35.5 Gy(중앙값 : 20.9 Gy)이었다. 종양 별로는 뇌하수체종양15예, 청각신경종 8예, 수막종 7예, 뇌교종 6예, 두개인두종 4예, 송과선종 3예, 혈관아세포종 2예, 및 뇌전이 암 1예 씩이었다. 총 46예 중 18예$(39.1\%)$에서 추적 영상검사상 종양의 소실 및 위축을 관찰하였으며, 10예$(34.8\%)$에서는 종양크기의 정지상태를 나타냈다. 임상적으로는 34예$(73.9\%)$에서 방사선치료 전보다 양호한 전신상태 및 수행능력을 유지하고 있었으며, 이중 4예 $(8.7\%)$에서는 추적 검사상 종양 크기가 약간 커졌음에도 불구하고 임상적으로는 안정된 상태이었다. 영상학적으로나 임상적으로 악화된 경우는 2예$(4.4\%)$에서 있었다. 치료에 따르는 부작용으로는 치료 직후, 일시적 두통을 호소하였으나 스테로이드 및 진통제 투여로 개선되었으며 경미한 일시적 탈모를 3예$(6.6\%)$에서 경험하였으며 향후 좀더 정밀 추적검사가 필요할 것으로 생각된다.

  • PDF

X-선 저장 BaFBr1-xIx:Eu2+, Na+ 형광체의 제조 및 특성 (Preparation and Properties of the X-ray Storage Phosphors BaFBr1-xIx:Eu2+, Na+)

  • 천종규;김성환;김찬중;김완;강희동;김도성;서효진;도시홍
    • 센서학회지
    • /
    • 제11권1호
    • /
    • pp.9-17
    • /
    • 2002
  • X-선 저장 형광체 $BaFBr_{1-x}I_x:Eu^{2+}$, $Na^+$의 조성 조건을 조사하고, 제조한 형광체의 광자극발광 강도, 스펙트럼, fading 특성 및 선량의존성을 조사하였다. 그리고 이 특성을 상업적으로 시판하고 있는 일본 부사(富士)사진필름회사 제품 영상판(ST-III)의 특성과 비교하였다. $BaFBr_{1-x}I_x:Eu^{2+}$, $Na^+$ 형광체의 최적 제조 조건은 $Eu_F3$ 0.5mol%, NaF 4.0mol% 그리고 조성비 x=0.3 이었으며, 소결온도는 수소 분위기에서 $950^{\circ}C$이었다. 조성비 x=0일 때 $BaFBr_{1-x}I_x:Eu^{2+}$, $Na^+$ 형광체의 스펙트럼영역은 $365{\sim}420\;nm$이었고, 최대 발광강도는 390 nm 이었다. $x{\neq}0$일 때 스펙트럼의 파장영역과 피이크 파장은 조성비 x가 증가할수록 장파장쪽으로 이동하였다. X-선 조사선량과 PSL 강도 사이에는 좋은 직선성을 나타내었다. 형광체의 fading 특성은 x=0.3일 때 가장 좋았으며, $I^-$ 이온의 농도가 증가할수록 저하되는 경향을 나타내었다. 또한 $BaFBr_{1-x}I_x:Eu^{2+}$ 격자상수는$I^-$이온의 농도가 증가할수록 커졌다.

흑국균(黑麴菌)의 인공변이(人工變異)에 관(關)한 연구(硏究) (Studies on the Mutation of Aspergillus niger)

  • 박윤중;손천배
    • 한국식품과학회지
    • /
    • 제14권1호
    • /
    • pp.72-79
    • /
    • 1982
  • Aspergillus niger CF를 최초(最初)의 균주(菌株)로 하고 이것에 자외선조사처리(紫外線照射處理)를 하여 돌연변이균주(變異菌株) Asp. niger CF-11을 얻었으며 이어서 NTG 처리(處理)에 의(依)하여 Asp. neger CF-11 균주(菌株)에서 변이균주(變異菌株) Asp. niger CF-22 및 CF-21를 분리(分離)하였다. 변이균주(變異菌株)의 특징(特徵)을 조사(調査)하고 밀기울국(麴) 및 밀가루국(麴)에서의 효소생산(酵素生産) 및 산생성(酸生成)을 검토(檢討)한 결과(結果)는 아래와 같다. 1. Asp. niger CF-22 변이균주(變異菌株)는 포자두(胞子頭)의 색(色)이 변(變)한 tan type의 균주(菌株)였으며 CF-22는 최초(最初)의 친주(親株) CF에 비(比)하여 밀기울국배양(麴培養)의 최적조건(最適條件)에서 글루코아밀라아제활성(活性)이 약(約) 2배(倍), ${\alpha}-$아밀라아제활성(活性)은 약(約) 50% 증가(增加)되었다. 2. Asp. niger CF-21 변이균주(變異菌株)는 포자두(胞子頭)의 색(色)은 변(變)하지 않았으나 밀기울국(麴)에서 생육(生育)과 포자착성(胞子着性)이 최초(最初)의 친주(親株) CF보다 늦었다. 이 변이균주(變異菌株)의 산생성력(酸生成力)은 최초(最初)의 친주(親株)보다 약(約) 4배(倍) 많았다. 3. Asp. niger CF-22 변이균주(變異菌株) 및 CF-21 변이균주(變異菌株)는 최초(最初)의 친주(親株)보다 클루코아밀라아제 및 ${\alpha}-$아밀라아제활성(活性)은 증강(增强)되었으나 단백질 가수분해효소의 활성(活性)은 오히려 떨어졌다. 4. 밀기울국(麴)에서 Asp. niger CF-22 변이균주(變異菌株)의 글루코아밀아제 생성(生成)의 최적조건(最適條件)은 $30{\sim}35^{\circ}C$에서 $2{\sim}3$일간(日間)이었으며 ${\alpha}-$아밀라아제의 경우는 $30{\sim}35^{\circ}C$에서 2일간(日間)이었다. 5. Asp. neger CF-21 변이균주(變異菌株)의 산생성력(酸生成力)은 밀기울국(麴)에서 $30^{\circ}C$로 2일후(日後)에 최고(最高)에 달(達)하였으며 밀가루국(麴)에서는 $30^{\circ}C$로 3일후(日後)에 최고(最高)값을 나타내었다. 최적조건(最適條件)에서의 산생성력(酸生成力)은 밀기울국(麴)과 밀가루국(麴) 사이에 차(差)가 별(別)로 없었다.

  • PDF

P. thunbergiana 잎으로부터 SK-HEP-1세포에 대한 apoptosis를 유도하는 광과민성물질의 분리 및 구조동정 (Isolation and Identification of a Photosensitizer from Pueraria thunbergiana Leaves that Induces Apoptosis in SK-HEP-1 Cells)

  • 이준영;김미경;하준영;김용균;홍창오;김소영;김충환;김근기
    • 생명과학회지
    • /
    • 제24권3호
    • /
    • pp.242-251
    • /
    • 2014
  • 국내에서 자생하는 P. thunbergiana 잎의 메탄올 추출물로부터 사람의 간암세포주, SK-HEP-1에 apoptosis를 유도하는 광과민성물질을 찾기 위해 연구를 시작하였다. Apoptosis를 유도하는 광과민성물질을 순수분리하기 위해 column chromatography법과 TLC법을 이용하였으며, 순수분리한 물질의 구조동정을 위하여 1D-NMR과 2D-NMR 및 FAB-MS분석을 실시하였다. P. thunbergiana 잎으로부터 크로마토그래피법을 이용해 순수분리한 M4-3 화합물의 흡광도를 측정한 결과 410 nm에서 최대 흡수를 보였고, 668, 502, 533, 607 nm에서 흡수 peak가 나타나는 녹색의 물질로 chlorophyll a, b와는 다른 물질이었다. FAB-MS 분석결과와 NMR 분석결과, 분자량 622의 132-hydroxy pheophorbide a methyl ester($C_{36}H_{28}N_2O_6$) 화합물로 porphyrin 환으로부터 Mg이온이 떨어져나간 pheophorbide a유도체화합물로 동정되었다. M4-3화합물을 SK-HEP-1세포에 대한 세포독성을 조사한 결과, 0.04 ${\mu}M$ 농도로 처리한 곳에서는 40% 세포증식 억제효과가 나타났고, 0.08 ${\mu}M$ 농도로 처리한 곳에서는 80% 세포증식 억제효과가 나타나 농도의존적이었다. 그리고 M4-3화합물을 동일한 농도로 처리하고, 광의 조사 유무에 따른 활성차이를 조사한 결과, 광을 조사한 곳에서만 세포독성이 나타났기 때문에 M4-3화합물은 광과민성물질이라는 것을 알 수 있었다. M4-3화합물을 처리하고 세포의 형태학적 변화를 관찰한 결과, 핵이 응축되었고, 소낭이 형성되었으며, DNA 단편화가 일어나는 등 apoptosis의 대표적인 현상들이 일어났기 때문에 M4-3화합물의 세포사멸은 광역학활성에 의한 apoptosis유도로 확인하였다.

K562 세포주에서 Genistein에 의해 억제되는 Radiation-induced Apoptosis의 조절 유전자 (Smad6 Gene and Suppression of Radiation-Induced Apoptosis by Genistein in K562 Cells)

  • 정수진;진영희;유여진;도창호;정민호;허기영;배혜란;양광모;문창우;오신근;허원주;이형식
    • Radiation Oncology Journal
    • /
    • 제19권3호
    • /
    • pp.245-251
    • /
    • 2001
  • 목적 : K562 세포를 대상으로 PTK inhibitor (herbimycinA와 genistein)에 의한 방사선 유도 apoptosis의 변화에 따른 관련 유전자를 탐색하고자 하였다. 대상 및 방법 : K562 세포는 $2\times10^5\;cells/mL$의 비율로 준비하여 대수증식기로 성장한 세포를 각각의 실험조건에 따라 처리하여 사용하였다. 방사선 조사는 6-MV X-Ray 10 Gy (Clinac 1800C, Varian, USA)를 $200\~300\;cGy/min$의 선량율로 상온에서 일정하게 조사하였다. Herbimycin A (HMA, Calbiochem, UK)와 genistein (Calbiochem, UK)은 dimethylsulfoxide (DMSO, Sigma, UK)에 녹여서 각각 1 mM과 10 mM의 농축용액으로 조제한 각각 250 nM과 $25\;{\mu}M$의 최종농도로 처리하였다. 내성 변화의 조절에 관여하는 유전자를 찾고자 PCR-select cDNA subtractive hybridization을 실시하여 128개의 차별 발현되는 clones을 재선별하였다. DNA sequencing을 통하여 염기서열을 분석하였으며, GenBank database를 이용하여 이미 밝혀진 유전자들과의 상동성을 비교하였다. 상동성을 갖는 clone을 확인하여 이를 probe로 사용하여 방사선 단독조사한 실험군과 방사선과 HMA 또는 genistein을 동시 처리한 실험군들간의 mRNA 발현의 차이를 Northern hybridization을 통하여 확인하였다. 결과 : homo sapiens Smad6 유전자와 $95\%$의 상동성을 갖는 clone을 확인하였다. 이를 probe로 사용하여 방사선 단독 조사한 실험군과 방사선과 HMA 또는 genistein을 동시 처리한 실험군들간의 mRNA 발현의 차이를 비교 분석한 결과, 방사선과 genistein을 동시 처리한 실험군의 mRNA 발현이 방사선 단독 조사한 실험군과 방사선과 HMA를 처리한 실험군들에 비하여 현저히 높았다. 결론 : Smad6와 방사선에 의해 유도되는 apoptosis의 억제에 관한 연관성을 보고한 문헌은 없으나, Smad6가 일부세포에서 apoptosis를 억제한다는 보고들과, 본 연구에서 관찰한 genistein에 의한 방사선에 의해 유도되는 apoptosis의 억제에서 그 발현이 두드러지게 증가한 점 등을 미루어 보아 방사선에 의하여 유도된 apoptosis의 억제 및 방사선 내성의 조절에도 관여할 것으로 생각된다.

  • PDF

생쥐에서 과립구 집락형성인자(Granulocyte-Colony Stimulating Factor)의 공장점막에 대한 방사선 보호효과 (Radioprotective Effects of Granulocyte-Colony Stimulating Factor in the Jejunal Mucosa of Mouse)

  • 유미령;정수미;계철승;김연실;윤세철
    • Radiation Oncology Journal
    • /
    • 제19권1호
    • /
    • pp.45-52
    • /
    • 2001
  • 목적 : 최근 항암 화학요법이나 두경부의 방사선치료 후 나타나는 백혈구감소증을 치료하기 위해 조혈세포 성장인자인 과립구 집락형성인자를 투여한 결과, 백혈군감소증과 더불어 구강 점막염의 완화가 몇몇 임상연구에서 보고되고 있다. 그러나 그 기전이나 적절한 투여 방법에 대해서는 뚜렷이 밝혀지지 않았으며, 다른 위장관 점막에 대한 보호효과에 대해서도 아직 알려진 바가 없다. 이에 저자는 생쥐 공장 점막에 대한 과립구 집락형성인자의 방사선 보호제로서의 가능성을 알아보고자 하였다. 대상 및 방법 : 실험 동물은 체중 20 g 내외의 생후 $4\~5$주된 BALB/c 생쥐 105 마리로 각각 정상 대조군, 과립구 집락형성인자 단독투여군(제 I 군 : $10\;{\mu}g/kg/$일, 제 II 군 $100\;{\mu}g/kg/$일), 방사선 단독조사군(7.5 Gy 또는 12 Gy 전신조사), 그리고 방사선조사와 과립구 집락형성인자 병행 처치군(G-CSF I 또는 II+7.5 Gy, G-CSF I 또는 II+12 Gy)의 아홉군으로 구분하였다. 과립구 집락형성인자는 과립구 집락형성인자 단독투여군 및 방사선조사와 과립구 집락 형성인자 병행처치군 모두에서 방사선조사 2일 전부터 24시간 간격으로 방사선조사일까지 3일 동안 매일 1회 피하 주사하였고, 방사선조사는 6 MV 선형 가속기를 이용하여 7.5 Gy와 12 Gy를 각 군별로 1회 전신조사하였다. 각 군별로 생쥐를 방사선조사 후 1, 3, 7일에 희생하여 공장을 적출하고 H&E 염색 및 PAS 염색을 시행한 후, 공장 조직 표본에서 소낭선의 수, 융모의 길이 및 조직학적 손상등급을 측정하고 조직학적 변화를 관찰하였다. 결과 : 방사선조사없이 과립구 집락형성인자 만을 투여한 군(제 I 군 : $10\;{\mu}g/kg/$ 및 제 II 군: $100\;{\mu}g/kg/$) 에서는 정상 대조군에 비해 생쥐 공장 점막 변화에 유의한 차이가 없었다(p>0.05). 7.5 Gy 및 12 Gy 방사선 단독조사군에서는 정상 대조군에 비해 공장 점막의 소낭선 수의 감소와 높은 조직학적 손상등급을 관찰하였다(p<0.05). 12 Gy 방사선조사와 과립구 집락형성인자 병행처치군에서는 공장 점막의 손상이 7.5 Gy 방사선 단독조사군에 비해 1일 군에서는 차이가 없었으나(p>0.05), 3일 군에서 유의하게 높은 소낭선 수 및 낮은 조직학적 손상등급을 관찰하였고, 7일 군에서 낮은 조직학적 손상등급을 관찰하였다(p<0.05). 12 Gy 방사선조사와 과립구 집락형성인자 병행처치군에서의 공장 점막 손상은 12 Gy 방사선 단독조사군에 비해 소낭선의 수와 융모의 길이, 조직학적 손상등급의 차이가 유의하지 않았으며(p>0.05), 두 마리를 제외한 대부분의 생쥐가 방사선조사 후 5일 이내에 모두 사망하였다. 결론 : 한계 선량 이내의 전신 방사선조사시 과립구 집락형성인자는 생쥐의 공장 점막에 대한 방사선보호작용이 있는 것으로 사료된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF