• 제목/요약/키워드: Iron surface

검색결과 1,092건 처리시간 0.036초

브로칭 가공된 회주철 소재 표면의 마찰 및 마모 특성 (Friction and Wear Characteristics of Gray Cast Iron Surface Processed by Broaching Method)

  • 권문성;강경희;김대은
    • Tribology and Lubricants
    • /
    • 제34권6호
    • /
    • pp.262-269
    • /
    • 2018
  • In this work the friction and wear characteristics of the gray cast iron surface processed by broaching method, which is widely used in the machinery industry, were investigated. The broaching process is mainly used for mass production because it has high dimensional accuracy and processing speed, but the defects on surface can be easily generated. In order to improve the tribological characteristics, the approach was to reduce the roughness and hardness of the surface by adding a machining process to the broaching specimen. The secondary machining process using abrasive grains produces low roughness and hardness than broaching because it has high tool accuracy and removes the work hardened surface. The friction coefficient and the wear rate were assessed using a reciprocating-type tribotester to analyze the effects of surface finishing on the tribological properties. The friction tests were conducted under dry and lubricated conditions. The test results showed that the reduction of surface roughness and hardness through secondary machining process in lubricated condition improved the friction and wear characteristics. The reason why the same results did not appear in a dry condition was that wear occurred more rapidly than in lubricated condition. Thus, the positive effect of roughness and hardness of the surface obtained through the secondary machining process was not observed.

Study on Poly(3,4-ethylenedioxythiophene) Thin Film Vapour Phase-Polymerized with Iron(III)Tosylate on AcOH-Catalyzed 3-Aminopropyltriethoxysilane Self-Assembled Monolayer

  • Choi, Sangil;Kim, Wondae;Kim, Sungsoo
    • 통합자연과학논문집
    • /
    • 제5권4호
    • /
    • pp.233-236
    • /
    • 2012
  • In this study, PEDOT thin films polymerized with Iron(III)tosylate ($Fe(PTS)_3$) and grown on acetic acid-catalyzed 3-aminopropyltriethoxysilane self-assembled monolayer (APS-SAM) surfaces by VPP method have been investigated. PEDOT thin films were synthesized on APS self-assembled $SiO_2$ wafer surface at two different concentrations (20 wt% and 40 wt%) and growth time (3 and 30 minutes), and then they were compared. PEDOT vapour phase-polymerized with 40 wt% $Fe(PTS)_3$ oxidant completely formed a thin film on acetic acid-catalyzed APS-SAM surface while with 20 wt% $Fe(PTS)_3$ did not at all. It means that the oxidant can be uniformly coated on acetic acid-catalyzed APS-SAM surface at the 40 wt% concentration, which gives rise to the uniform growth of PEDOT thin film on it.

펄스반복율의 가변에 의한 대기압 아크방전중의 고효율 금속산화물 제거 특성 (High Efficient Metal-oxide Removing Characteristics as Pulse Repetition Rates in the Atmospheric Arc Discharge)

  • 이윤수;송우정;김수원;정종한;김용철;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권4호
    • /
    • pp.179-184
    • /
    • 2003
  • The pulsed power system is widely used for many industries and environments. Generally, we call the "RUST", the reddish brown surface, that was made on iron surface or some other metals, when they are contacted by water and air the main substance of rust is oxide-ionization. In other words, the chemical symbol of rust on iron surface is iron oxide(III) hydrate Fe203.nH2O. In this study, we have designed and fabricated our system which has a compact pulse generator with switching MOSFET. Also we have studied the metal-oxide removing characteristics using in the atmospheric arc discharge. It has been investigated their removing characteristics by the change of charging voltage and pulse repetition rates. From this result, we can find out that the removal area Is increased from 3.80 to 8.04[$\textrm{cm}^2$], when pulse duration is increased from 100[pps] to 400[pps]. 400[pps].

영가금속에 의한 Endosulfan I과 II의 환원분해에 미치는 계면활성제의 영향 (Effect of surfactants on reductive degradation of Endosurfan I and II by ZVM)

  • 김진영;김영훈;신원식;전영웅;송동익;최상준
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.187-190
    • /
    • 2002
  • Reductive dechlorination of endosulfans was studied with zero valent metals (ZVMs) and bimetals in aqueous batch reactors. The effect of surfactants was evaluated. Endosulfan was successfully dechlorinated with zero valent iron. However, a bimetal, palladium coated iron (Pd/Fe) showed a highly enhanced reactivity for both endosulfan I and II indicating palladium act as a dechlorination catalyst on the iron. The effect of surfactants on degradation with ZVM has been very controvertible. Variable concentration of a nonionic surfactant, Triton X-100 and an anionic surfactant, SDS were added into the reactor with ZVM. The reaction rates of endosulfan were increased with both surfactants. In the case of Triton X-100, the reaction rate was increased with the increasing surfactant concentration up to 400 mg/L. Addition of small amount of surfactant under the CMC, the reaction rate was increased. However, the enhancing effect was diminished when a higher concentration of surfactant (1,000 mg/L) was used. Current study implicate that the surfactant adsorbed on the metal surface might increase the surface concentration of endosulfan resulting in the increased reaction rate. However, partitioning of endosulfan into the micelle formed at the high concentration of surfactant diminish the enhancing effect by reducing the contact chance between target compound and the metal surface.

  • PDF

Preparation of Fe-ACF/TiO2 Composites and their Photocatalytic Degradation of Waste Water

  • Oh, Won-Chun;Bae, Jang-Soon
    • 한국세라믹학회지
    • /
    • 제45권11호
    • /
    • pp.667-674
    • /
    • 2008
  • In this study, we prepared Fe-activated carbon fiber(ACF)/$TiO_2$ composites with titanium (VI) n-butoxide (TNB) as the titanium source for ACF pre-treated with iron compounds through the impregnation method. In terms of textural surface properties, the composites demonstrate a slight decrease in the BET surface area of the samples and an increase in the amount of iron compounds treated. The surface morphology of the Fe-ACF/$TiO_2$ composites was characterized by means of SEM. The composites have a porous texture with homogenous compositions of Fe and titanium dioxide distributed on the sample surfaces. The phase formation and structural transition of the iron compounds and titanium dioxide were observed in X-ray diffraction patterns of the Fe-ACF/$TiO_2$ composites. The chemical composition of the Fe-ACF/$TiO_2$ composites, which was investigated with EDX shows strong peaks for the C, O, Fe and Ti elements. The photo degradation results confirm that the Fe-ACF/$TiO_2$ composites show excellent removal activity for the COD in piggery waste due to photocatalysis of the supported $TiO_2$, radical reaction by Fe species, and the adsorptivity and absorptivity of ACF.

Corrosion of Carbon Steel with and without Aluminized Coating in (O, S, H)-containing Gases at 500-800℃

  • Lee, Dong Bok;Abro, Waheed Ali;Lee, Kun Sang;Abro, Muhammad Ali
    • 한국표면공학회지
    • /
    • 제50권2호
    • /
    • pp.85-90
    • /
    • 2017
  • The carbon steel formed the thick, somewhat porous, loosely adherent iron oxide scale when oxidized at $500-800^{\circ}C$ for 15 h in air. It formed the thicker, more porous, nonadherent scale consisting of FeS plus iron oxides in $Ar/1%SO_2$-mixed gas. It formed the much thicker, more porous, nonadherent scale consisting of FeS plus iron oxides in Ar/0.1% $H_2S$-mixed gas. However, the aluminized carbon steel formed the thin, protective $Al_2O_3$ surface scale even in $Ar/1%SO_2$-, and $Ar/0.1%H_2S$-mixed gas. Aluminizing drastically improved the corrosion resistance in (O, S, H)-containing gas.

Comparison of the Characteristics in the Surface Mounted Permanent Magnet and Flux Concentrating Coaxial Magnetic Gears Having the Solid Cores

  • Shin, Ho-Min;Chang, Jung-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1275-1284
    • /
    • 2018
  • The coaxial magnetic gear with the flux concentrating structure is known that it has the torque performance advantage over the coaxial magnetic gear having surface mounted permanent magnet, thanks to the flux focusing effect. But, if the solid cores are used in the modulating pieces and rotor cores to consider the mechanical reliability and cost reduction, the operating torque of the flux concentrating coaxial magnetic gear can be significantly diminished because the iron losses at the solid cores affect the actual transmitted torque. Furthermore, the modulating pieces and rotor cores have different characteristics of the iron losses from one another, because the space harmonic components of the magnetic flux density, which cause the iron losses, are different. Thus, in this paper, we focused on the analysis of the characteristics of the space harmonic components of the magnetic flux density and resultant eddy current losses in the surface mounted PM and flux concentrating coaxial magnetic gears, when these coaxial magnetic gears have the solid cores at the modulating pieces and rotor cores. The characteristics of pull-out torque (static torque), operating torque (dynamic torque), and efficiency are also researched, and compared by the 3D finite element analysis (FEA) and experiment.

복합오염물질 제거를 위한 철과 개량 벤토나이트의 복합층에 관한 연구 (Hybrid Barriers of Iron and Modified-bentonite for the Remediation of Multi-contaminated Water)

  • 조현희;박재우
    • 한국물환경학회지
    • /
    • 제20권5호
    • /
    • pp.512-519
    • /
    • 2004
  • Hybrid barriers using reduction and immobilization were tested to remediate the groundwater contaminated with multi-pollutants in this study. Iron filings and HDTMA(hexadecyltrimethylammonium)-bentonite were simulated in columns to assess the performance of hybrid barriers for remediation of trichloroethylene(TCE)-contaminated water. TCE reduction rate for the mixture of iron filings and HDTMA-bentonite was about 7 times higher than that for iron filings, only suggesting the reduction of TCE was accelerated when HDTMA-bentonite was mixed with iron filings. TCE reduction rate for the two layers of iron and HDTMA-bentonite was nearly similar to that for iron filings alone, but the partition coefficient($K_d$) for the two layers was 4.5 times higher than for that iron filings only. TCE was immobilized in the first layer with HDTMA-bentonite, and then dechlorinated in the second layer with iron filings. HDTMA-bentonite may contribute to the increase in TCE concentration on iron surface so that more TCE can be reduced. Also, TCE removal in the hybrid barriers was not affected by chromate and naphthalene while the reduction rate of TCE with the co-existing contaminants by iron filings was significantly decreased. Significant TCE removal in this research indicates that the proposed hybrid barrier system has the potential to become the effective remediation alternative during the occurrence of oil shock. Also, if subsurface environments are contaminated with multi-pollutants that contain non-reducible compounds as well as reducible compounds such as TCE, the conventional reactive barriers cannot be applied to this subsurface environment, while the proposed hybrid system can be applied successfully.