• Title/Summary/Keyword: Iron saturation

Search Result 254, Processing Time 0.03 seconds

An Iron-cored CT Design Considering Overdimensioning Factor (과단면적 계수를 고려한 철심 변류기 설계 방법)

  • Lee, J.H.;Kang, S.H.;Lee, S.J.;Kang, Y.C.;Bae, J.C.;Ahn, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.834-836
    • /
    • 1998
  • Current transformer (CT) saturation may cause a variety of protective relays to malfunction. The conventional CT is designed that it can carry up to 20 times the rated current. However, the possibility of CT saturation still remains, because the fault current may have substantial amounts of ac and/or de components. This paper presents a iron-cored CT design method to prevent CT saturation. The proposed method employs the overdimensioning factor $(K_{ta})$ considering dc components contained as well as symmetrical ac components in the fault current.

  • PDF

Effects of Dietary Animal Protein and Plant Protein on Iron Bioavailability in Young Korean Women (동물성과 식물성단백질이 한국인 젊은여성의 체내 철분이용도에 미치는 영향)

  • 곽충실
    • Journal of Nutrition and Health
    • /
    • v.27 no.5
    • /
    • pp.451-459
    • /
    • 1994
  • This study was performed to investigate the effect of sources of protein on iron bioavailability in 10 healthy young Korean women. The 18-day metabolic study consisted of a 6-day adaptation period, 6-day moderate protein(60g protein/day, 18mg Fe/day) and 6-day high protein period(90g protein/day, 18mg Fe/day). During the moderate and high protein period, 5 subjects were fed the high plant protein meals(80% plant protein). Fecal excretion of dietary iron was significantly higher(p<0.05) in high protein high plant diet group(HPP, 9.48$\pm$1.61mg/day) than in high protein high animal diet group (HPA, 14.40$\pm$0.89mg/day). Apparent absorption and bioavailability of iron was also significantly higher(p<0.10) in HPA(40.7$\pm$5.3%, 6.46$\pm$1.61mg/day) than in HPP(14.4$\pm$5.3%, 2.39$\pm$0.89mg/day). But there was no significant difference between the high animal protein group and high plant protein group in moderate protein period. Serum iron concentration and transferrin saturation increased as animal protein intake increased, from 106.0$\pm$5.1ug/이 and 30.6$\pm$1.5% for MPA to 129.1$\pm$6.7ug/이 and 37.1$\pm$1.3% for HPA. Statistically positive correlations were shown not only between the level of dietary heme iron and apparent absorption(r=0.95, p<0.05), but also between serum iron concentration and apparent absorption(r=0.64, p<0.05). Negative iron balance was shown in two subjects fed the moderate protein meals. These results suggest that recommanded dietary allowances of iron may be under the need to maintain the positive balance, and iron bioavaliability increase by only high level of animal protein intake.

  • PDF

Magnetic Saturation and Iron Loss Influence on Max Torque per Ampere Current Vector Variation of Synchronous Reluctance Machine (동기형 릴럭턴스 전동기 MTPA 제어시 자기포화 및 철손의 영향)

  • Liu, Huai-Cong;Hong, Hyun-Seok;Hanm, Sang-Hwan;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.667-668
    • /
    • 2015
  • Synchronous Reluctance Motor (SynRM) has a simple structure with high efficient and without rotor conductor loss. Therefore, it is better than induction motor for electric vehicle (EV) on aspect of efficiency. SynRM usually operates on the constant torque region using maximum torque per ampere (MTPA)control which is adopted due to rotor structure limitation. Thus, the accurate current angle is crucial for motor control. However, finite element analysis (FEA) program is not sufficient exactly to regard how the iron loss and magnetic saturation influences on the current angle. Consequently, this paper proposed a method to calculate the current angle with consideration of iron loss.

  • PDF

EMTP-RV Modeling of CT Saturation (EMTP-RV를 이용한 CT포화 모델링)

  • Kang, Yong-Cheol;Choi, Jae-Sun;Zheng, Tai-Ying;Kang, Hae-Gweon;Jang, Sung-Il;Kim, Yong-Gyun;Ryu, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.9-11
    • /
    • 2008
  • A protection current transformer (CT) has been widely used for protection devices. When a fault occurs, a CT should provide the faithful reproduction of the primary fault current. However, a CT may saturates due to the magnitude of fault current, dc component primary time constant and the remanent flux of the iron core, and the secondary current of a CT is distorted. The distorted current can cause mal-operation or the operating time delay of a protection relay. This paper provides a modeling of CT saturation using EMTP-RV. The performance of the proposed CT saturation modeling was investigated under various fault conditions varying the fault distance, fault inception angle, and remanent flux of the iron core. The results indicate that the proposed EMTP-RV modeling can operate correctly, and the reasons for CT saturation are verified by EMTP-RV simulations.

  • PDF

Physical Properties of Fe Particles Fine-dispersed in AlN Thin Films (Fe 입자를 미세 분산 시킨 AlN 박막의 물리적 성질)

  • Han, Chang-Suk;Kim, Jang-Woo
    • Korean Journal of Materials Research
    • /
    • v.21 no.1
    • /
    • pp.28-33
    • /
    • 2011
  • This paper describes the fabrication of AlN thin films containing iron and iron nitride particles, and the magnetic and electrical properties of such films. Fe-N-Al alloy films were deposited in Ar and $N_2$ mixtures at ambient temperature using Fe/Al composite targets in a two-facing-target DC sputtering system. X-ray diffraction results showed that the Fe-N-Al films were amorphous, and after annealing for 5 h both AlN and bcc-Fe/bct-$FeN_x$ phases appeared. Structure changes in the $FeN_x$ phases were explained in terms of occupied nitrogen atoms. Electron diffraction and transmission electron microscopy observations revealed that iron and iron nitride particles were randomly dispersed in annealed AlN films. The grain size of magnetic particles ranged from 5 to 20 nm in diameter depending on annealing conditions. The saturation magnetization as a function of the annealing time for the $Fe_{55}N_{20}Al_{25}$ films when annealed at 573, 773 and 873 K. At these temperatures, the amount of iron/iron nitride particles increased with increasing annealing time. An increase in the saturation magnetization is explained qualitatively in terms of the amount of such magnetic particles in the film. The resistivity increased monotonously with decreasing Fe content, being consistent with randomly dispersed iron/iron nitride particles in the AlN film. The coercive force was evaluated to be larger than $6.4{\times}10^3Am^{-1}$ (80 Oe). This large value is ascribed to a residual stress restrained in the ferromagnetic particles, which is considered to be related to the present preparation process.

Iron deficiency anemia as a predictor of coronary artery abnormalities in Kawasaki disease

  • Kim, Sohyun;Eun, Lucy Youngmin
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.8
    • /
    • pp.301-306
    • /
    • 2019
  • Purpose: Coronary artery abnormalities (CAA) are the most important complications of Kawasaki disease (KD). Iron deficiency anemia (IDA) is a prevalent micronutrient deficiency and its association with KD remains unknown. We hypothesized that presence of IDA could be a predictor of CAA. Methods: This retrospective study included 173 KD patients, divided into 2 groups according to absence (group 1) and presence (group 2) of CAA. Odds ratios (ORs) with 95% confidence intervals (CIs) were calculated using a logistic regression model to estimate the association between CAA and other indicators. Due to collinearity between indicators of IDA, each indicator was paired with anemia in 3 models. Results: Serum iron, iron saturation, and ferritin concentration, the 3 indicators of IDA, were significantly higher in group 1 than in group 2. Three sets of models including anemia with iron indicators produced the OR of CAA of 3.513, 3.171, and 2.256, respectively. The 3 indicators of IDA were negatively associated with CAA, by OR of 0.965, 0.914, and 0.944, respectively. The areas under the curve (AUCs) of ferritin concentration, iron saturation, serum iron, anemia, and Kobayashi score were 0.907 (95% CI, 0.851-0.963), 0.729 (95% CI, 0.648-0.810), 0.711 (95% CI, 0.629-0.793), 0.638 (95% CI, 0.545-0.731), and 0.563 (95% CI, 0.489-0.636), respectively. Conclusion: Indicators of IDA, especially ferritin, were highly associated with CAA; therefore, they were stronger predictors of CAA than Kobayashi scores. IDA indicators can be used to predict CAA development and to suggest requirements for early interventions.

Active Cancellation of PMSM Torque Ripple Caused by Magnetic Saturation for EPS Applications

  • Lee, Geun-Ho
    • Journal of Power Electronics
    • /
    • v.10 no.2
    • /
    • pp.176-180
    • /
    • 2010
  • This paper deals with a control method to reduce the torque ripple of a permanent magnet synchronous motor (PMSM) for electric power steering (EPS) systems. Such an application requires a very low torque ripple in order to maintain a good steering feel. However, because of spatial limitations, it cannot help having a partial saturation in the iron core of the PMSM for an EPS system, and this saturation results in a significant torque ripple. Thus, this paper analyzes the torque ripple caused by the magnetic saturation of a PMSM and proposes a method with respect to inductance measurement to verify the partial saturation. In addition, it is shown that a compensation current is needed in order to minimize the torque ripple when a PMSM is driven in the high torque region. The estimation process of the current and the torque ripple decreased by the current are presented and verified with test results.

A Design Method of Iron-cored CTs To Prevent Satruation (포화를 방지하기 위한 보호용 철심 변류기 설계 방법)

  • Lee, Ju-Hun;Gang, Sang-Hui;Gang, Yong-Cheol;Lee, Seung-Jae;Bae, Ju-Cheon;An, Jun-Gi;Lee, Cheong-Hak;Lee, Jeong-Taek
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.2
    • /
    • pp.119-126
    • /
    • 1999
  • Current transformer (CT) saturation may cause a variety of protective relays to malfunction. The conventional CT is designed that it can carry up to 20 times the rated current without exceeding 10% ratio error. However, the possibility of CT saturation still remains if the fault current contains substantial amounts of ac and/or dc components. This paper presents a design method of iron-cored CTs for use with protective relays to prevent CT saturation. The proposed design method determines the core cross section of the CT; it employs the transient dimensioning factor to consider relay's operating time (duty cycle) and dc component as well as ac components contained in the fault current, and symmetrical short-circuit current factor to consider as well as ac components contained in the fault current, and symmetrical short-circuit current factor to consider the biggest fault current. The method designs the cross section of CTs in cases of reclosure and no reclosure.

  • PDF

Associations of Serum Ferritin and Transferrin % Saturation With All-cause, Cancer, and Cardiovascular Disease Mortality: Third National Health and Nutrition Examination Survey Follow-up Study

  • Kim, Ki-Su;Son, Hye-Gyeong;Hong, Nam-Soo;Lee, Duk-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.45 no.3
    • /
    • pp.196-203
    • /
    • 2012
  • Objectives: Even though experimental studies have suggested that iron can be involved in generating oxidative stress, epidemiologic studies on the association of markers of body iron stores with cardiovascular disease or cancer remain controversial. This study was performed to examine the association of serum ferritin and transferrin saturation (%TS) with all-cause, cancer, and cardiovascular mortality. Methods: The study subjects were men aged 50 years or older and postmenopausal women of the Third National Health and Nutrition Examination Survey 1988-1994. Participants were followed-up for mortality through December 31, 2006. Results: Serum ferritin was not associated with all-cause, cancer, or cardiovascular mortality for either men or postmenopausal women. However, all-cause, cancer, and cardiovascular mortality were inversely associated with %TS in men. Compared with men in the lowest quintile, adjusted hazard ratios for all-cause, cancer, and cardiovascular mortality were 0.85, 0.86, 0.76, and 0.74 ($p$ for trend < 0.01), 0.82, 0.73, 0.75, and 0.63 ($p$ for trend < 0.01), and 0.86, 0.81, 0.72, and 0.76 ($p$ for trend < 0.01), respectively. For postmenopausal women, inverse associations were also observed for all-cause and cardiovascular mortality, but cancer mortality showed the significantly lower mortality only in the 2nd quintile of %TS compared with that of the 1st quintile. Conclusions: Unlike speculation on the role of iron from experimental studies, %TS was inversely associated with allcause, cancer and cardiovascular mortality in men and postmenopausal women. On the other hand, serum ferritin was not associated with all-cause, cancer, or cardiovascular mortality.

Anemia and Iron Deficiency according to Feeding Practices in Infants Aged 6 to 24 Months

  • 김순기
    • Journal of Nutrition and Health
    • /
    • v.31 no.1
    • /
    • pp.96-101
    • /
    • 1998
  • The prevalence of iron deficiency in later infancy and the toddler years(25% to 40% at 1 year of age) has not decreased remarkably , except in Western countries. The purpose of this study was to 1) determine the relationship between current feeding practices and iron status, and 2) assess compliance to infant feeding instructions. Two groupsof infants were examined. The first group of 302 infants aged 6 to 24months was seen at a well baby clinic while the second group of 135 infants of the same age group was assessed by venipuncture. Cutoff values for laboratory tests were as follows ; hemoglobin<11g/dL, mean corpuscular volume (MCV) <72fl ; red cell distribution width(RDW)>15% ; serum ferritin level<10ng/ml ; and transferrin saturation (serum iron(TIBC)<10%. The diagnosis of iron deficiency anemia (IDA) was made when a low hemoglobin level was associated with either low ferritin orlow transferrin saturation . Of the 302 children brought to the well baby clinic , 12.3%(n=37) were found to have anemia (hemoglobin<11.0/dL). In terms of children grouped according to feeding practices, it was found that children with anemial comprised 32.0% (24/75) of the prolonged breast-fed group (Group A), significantly more than the 4.0%(7/176) of the artificial milk feeding group(Group B). and 3.9%(2/51) of the switched from breast milk to iron -fortified weaning foods group(Group C).Among the 107 children with IDA , iron deficiency in 105 children(98.1%) was suggested by their dietary histories ; exclusive or prolonged breast-feeding for more than 6 months without iron fortification in 98 infants ; cow's milk consumption> 500ml/day without iron fortification during infancy(n=12), or >800ml without iron-fortified foods after infancy(n=15) ; and the use of unfortified forumula or unbalanced diets, mainly limited to rice gruel. Despite the relatively high (79.6%) motivation on the part of the infants mothers and supervison by professional personnel, the poor results in the infants receiving iron fortified foods were due to poor compliance(85.75). Among the mothers of 98 IDA patients who were contacted by telephone , it was revealed that 29% did not give the oral iron preparation for more than 2 months. Furthermore, negligence or disregard by the parents occurred in 14% of the case , discontinuance of the oral iron preparation by the parents due to side effects occurred in 6%, and the children's refusal or poor oral intake and no further trial occurred in 6%. The dietary history of a large group of infants was highly predictive of their risk for anemia . Continued consumption of breast milk until the age of 1 year is not warranted unless iron-fortified foods are given concomitantly. Because there is a problem with compliance, more successful and safe strategies for preventing iron deficiency woold included dual coverage in the from of therapeutic iron supplementation as well use of iron-fortified foods for teddlers who are at risk of iron deficiency.

  • PDF