• Title/Summary/Keyword: Iridium

Search Result 260, Processing Time 0.028 seconds

Synthesis and Oxidation Behavior of Pd-Ir@CeO2 Core-shell Nanoparticles for Hydrogen Gas Sensor

  • Gi-Seung Shin;Dong-Seog Kim;Tuong Van Tran;Geun-Jae Oh;Seok-Yong Hong;Ho-Geun Song;Yeon-Tae Yu
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.288-297
    • /
    • 2024
  • Currently, numerous studies are being conducted on metal oxide semiconductor (MOS) gas sensors for hydrogen detection, using Palladium (Pd) and Pd-based alloy nanoparticles (NPs) owing to their hydrogen absorption ability. Furthermore, several studies have reported that Pd-Iridium (Ir) alloys possess high hydrogen absorption capabilities in their bulk state. However, Ir growth is limited to above 2 nm and it does not mix extensively with other metals. Furthermore, as the hydrogen absorption capacity decreases with the reduction in particle size, it is necessary to synthesize nanoparticles of an appropriate size. Therefore, the synthesis of Pd-Ir alloy NPs larger than 10 nm is challenging. In this study, we report the synthesis of Pd-Ir NPs with an average diameter of 19 nm using a hydrothermal technique for the first time and fabricated Pd-Ir alloy NPs through calcination at 500℃ in Ar and air. To confirm alloy formation and oxidation behavior, X-ray diffraction (XRD) and X-ray photoelectron spectroscopy (XPS) were performed. In addition, we synthesized Pd-Ir@CeO2 core-shell nanoparticles (CSNPs) as hydrogen gas-sensing materials. The Pd-Ir core was partially oxidized during heat treatment at 500℃ in air, and Pd-Ir@CeO2 CSNPs were finally changed into Pd-Ir(alloy)/PdO-IrO2@CeO2 CSNPs, which exhibited higher sensitivity and selectivity toward H2 gas compared to totally oxidized PdO-IrO2@CeO2 CSNPs and pure CeO2 NPs. The enhanced gas-sensing performance was attributed to the hydrogen absorption effect of the Pd-Ir(alloy) NPs.

Comparison between the Calculated and Measured Doses in the Rectum during High Dose Rate Brachytherapy for Uterine Cervical Carcinomas (자궁암의 고선량율 근접 방사선치료시 전산화 치료계획 시스템과 in vivo dosimetry system 을 이용하여 측정한 직장 선량 비교)

  • Chung, Eun-Ji;Lee, Sang-Hoon
    • Radiation Oncology Journal
    • /
    • v.20 no.4
    • /
    • pp.396-404
    • /
    • 2002
  • Purpose : Many papers support a correlation between rectal complications and rectal doses in uterine cervical cancer patients treated with radical radiotherapy. In vivo dosimetry in the rectum following the ICRU report 38 contributes to the quality assurance in HDR brachytherapy, especially in minimizing side effects. This study compares the rectal doses calculated in the radiation treatment planning system to that measured with a silicon diode the in vivo dosimetry system. Methods : Nine patients, with a uterine cervical carcinoma, treated with Iridium-192 high dose rate brachytherapy between June 2001 and Feb. 2002, were retrospectively analysed. Six to eight-fractions of high dose rate (HDR)-intracavitary radiotherapy (ICR) were delivered two times per week, with a total dose of $28\~32\;Gy$ to point A. In 44 applications, to the 9 patients, the measured rectal doses were analyzed and compared with the calculated rectal doses using the radiation treatment planning system. Using graphic approximation methods, in conjunction with localization radiographs, the expected dose values at the detector points of an intrarectal semiconductor dosimeter, were calculated. Results : There were significant differences between the calculated rectal doses, based on the simulation radiographs, and the calculated rectal doses, based on the radiographs in each fraction of the HDR ICR. Also, there were significant differences between the calculated and measured rectal doses based on the in-vivo diode dosimetry system. The rectal reference point on the anteroposterior line drawn through the lower end of the uterine sources, according to ICRU 38 report, received the maximum rectal doses in only 2 out of the nine patients $(22.2\%)$. Conclusion : In HDR ICR planning for conical cancer, optimization of the dose to the rectum by the computer-assisted planning system, using radiographs in simulation, is improper. This study showed that in vivo rectal dosimetry, using a diode detector during the HDR ICR, could have a useful role in quality control for HDR brachytherapy in cervical carcinomas. The importance of individual dosimeters for each HDR ICR is clear. In some departments that do not have the in vivo dosimetry system, the radiation oncologist has to find, from lateral fluoroscopic findings, the location of the rectal marker before each fractionated HDR brachytherapy, which is a necessary and important step of HDR brachytherapy for cervical cancer.

A Study on the Liability for Damage caused by Space Activity - With reference to Relevant Cases - (우주활동에 의하여 발생한 손해배상책임에 관한 연구 - 관련 사례를 중심으로 -)

  • Lee, Kang-Bin
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.26 no.1
    • /
    • pp.177-213
    • /
    • 2011
  • The purpose of this paper is to research on the liability and cases for space damage with reference to the space activity under the international space treaty and national space law of major countries. The United Nations has adopted two treaties relating to the liability for space damage as follows: the Outer Space Treaty of 1967 and the Liability Convention of 1972. Korea has enacted the Outer Space Damage Compensation Act of 2008 relating to the liability for space damages. The Outer Space Treaty of 1967 regulates the international responsibility for national activities in outer space, and the national tort liability for damage by space launching object. The Liability Convention of 1972 regulates the absolute liability by a launching state, the faulty liability by a launching state, the joint and several liability by a launching state, the person claiming for compensation, the claim method for compensation, the claim period of compensation, the claim for compensation and local remedy, the compensation amount for damage by a launching state, and the establishment of the Claims Commission. The Outer Space Damage Compensation Act of 2008 in Korea regulates the definition of space damage, the relation of the Outer Space Damage Compensation Act and the international treaty, the non-faulty liability for damage by a launching person, the concentration of liability and recourse by a launching person, the exclusion of application of the Product Liability Act, the limit amount of the liability for damage by a launching person, the cover of the liability insurance by a launching person, the measures and assistance by the government in case of occurring the space damage, and the exercise period of the claim right of compensation for damage. There are several cases with reference to the liability for damage caused by space accidents as follows: the Collision between Iridium 33 and Cosmos 2251, the Disintegration of Cosmos 954 over Canadian Territory, the Failure of Satellite Launching by Martin Marietta, and the Malfunctioning of Westar VI Satellite. In the disputes and lawsuits due to such space accidents, the problems relating to the liability for space damage have been settled by the application of absolute(strict) liability principle or faulty liability principle. The Liability Convention of 1972 should be improved as follows: the clear definition in respect of the claimer of compensation for damage, the measure in respect of the enforcement of decision by the Claims Commission. The Outer Space Damage Compensation Act of 2008 in Korea should be improved as follows: the inclusion of indirect damage into the definition of space damage, the change of the currency unit of the limit amount of liability for damage, the establishment of joint and several liability and recourse right for damage by space joint launching person, and the establishment of the Space Damage Compensation Review Commission. Korea has built the space center at Oinarodo, Goheung Province in June 2009. Korea has launched the first small launch vehicle KSLV-1 at the Naro Space Center in August 2009 and June 2010. In Korea, it will be the possibility to be occurred the problems relating to the international responsibility and the liability for space damage in the course of space activity. Accordingly the Korean government and launching organization should make the legal and systematic policy to cope with such problems.

  • PDF

Rectal Complication Following Radical Radiotherapy in Carcinoma of the Uterine Cervix (자궁경부암에서 근치적 방사선치료 후의 직장 합병증)

  • Kim Won-Dong;Park Woo-Yoon
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.44-50
    • /
    • 2006
  • Puroose: This study evaluated the late rectal complications in cervix cancer patients following treatment with external beam radiotherapy (EBRT) and high dose rate intracavitary radiation (HDR ICR). The factors affecting the risk of developing late rectal complications and its incidence were analyzed and discussed. Materials and Methods: The records of 105 patients with cervix cancer who were treated with radical radiotherapy using HDR ICR between July, 1995 and December, 2001 were retrospectively reviewed. The median dose of EBRT was 50.4Gy $(41.4{\sim}56.4 Gy)$ with a daily fraction size of 1.8Gy. A total of $5{\sim}7$ (median: 6) fractions of HDR ICR were given twice weekly with a fraction size of $4{\sim}5 Gy$ (median: 4Gy) to A point using an Ir (Iridium)-192 source. The median dose of ICR was 24 Gy $(20{\sim}35 Gy)$. During HDR ICR, the rectal dose was measured in vivo by a semiconductor dosimeter. The median follow-up period was 32 months, ranging from 5 to 84 months. Results: Of the 105 patients, 12 patients (11%) developed late rectal complications: 7 patients with grade 1 or 2, 4 patients with grade 3 and 1 patient with grade 4. Rectal bleeding was the most frequent chief complaint. The complications usually began to occur $5{\sim}32$ (median: 12) months after the completion of radiotherapy. Multivariate analysis revealed that the measured cumulative rectal BED over 115 Gy3 (Deq over 69 Gy) and the depth (D) of a 5 Gy isodose volume more than 50 mm were the independent predictors for late rectal complications. Conclusion: With evaluating the cumulative rectal BED and the depth of a 5 Gy isodose volume as predictors, we can individualize treatment planning to reduce the probability of late rectal complications.

Intraluminal High-Dose-Rate Brachytherapy for the Tumors of Gastrointestinal Tract (위장관 종양의 고선량율 강내 방사선치료)

  • Choi Byung Ock;Choi Ihl Bhong;Chung Su Mi;Kim In Ah;Choi Myoung Gyu;Chang Suk Kyun;Shinn Kyeong Sub
    • Radiation Oncology Journal
    • /
    • v.13 no.3
    • /
    • pp.243-252
    • /
    • 1995
  • Purpose : Intraluminal high dose rate brachytherapy is an accepted treatment for the tumors of GI tract. However, there is only some limited clinical data for intraluminal high dose rate brachytherapy for the tumors of GI tract. Materials and Methods : Between February 1991 and July 1993, 18 Patients who have the tumors of GI tract (esophageal cancer-8 cases, rectal cancer-10 cases) were treated with high dose rate Iridium-192 afterloading system (Microselectron-HDR, Nucletron CO, Netherland) at the department of therapeutic radiology, St. Mary's hospital, Catholic university medical college. Age range was 47-87 years with a mean a9e 71 years. All patients were treated with intraluminal high dose rate brachytherapy within two weeks after conventional external radiation therapy and received 3-5 Gy/fraction 3-4 times per week to a total dose 12-20 Gy (mean 17 Gy). Standard fractionation and conventional dose were delivered for external radiation therapy. Total dose of external radiation therapy ranged 41.4-59.4 Gy (mean 49.6 Gy). Median follow up was 19 months Results : The analysis was based on 18 patients, The complete response and partial response in esophageal cancer was similar (38%). Two year rates for survival and median survival were 13% and 10 months, respectively. Among 10 patients of rectal cancers, partial response was obtained in 6 patients (60%). There was no complete response in the patients with rectal cancer, but good palliative results were achieved in all patients. Conclusion : Although the number of patients was not large and the follow-up period was relatively short, these findings suggested that intraluminal high dose rate brachytherapy could be useful in the treatment of the patients with advanced tumors of GI tract.

  • PDF

The Role of Intraluminal Brachytherapy in Management of Esophageal Cancer (식도암 치료에 있어 관내근접치료의 역할)

  • Lee Chang Geol;Suh Chang Ok;Kim Gwi Eon;Chu Sung Sil;Chung Eun Ji;Kim Woo Cheol
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.331-338
    • /
    • 1995
  • Purpose : To evaluate our clinical experience with the combination of teletherapy and intraluminal brachytherapy in patients with unresectable or inoperable esophageal cancers. Materials and Methods : From Nov 1989 to Mar 1993, twenty patients with esophageal cancer were treated with radical radiotherapy and intraluminal brachytherapy at Yonsei Cancer Center. All patients had squamous histolgy and stage distribution was as follows: stage II, 4($20{\%}$)patients; III, 15 ($75{\%}$)patients; IV, 1($5{\%}$)patients. A dose of S-12Gy/1-3weeks with intraluminal brachytherapy (3-5Gy/fraction) to 5mm from the outside of the esophageal tube using high dose rate Iridium-192 remotely afterloading brachytherapy machine was given 2 weeks after a total dose of 59-64Gy with external radiotherapy. Induction chemotherapy using cisplatin and 5-FU was performed in 13 patients with median 3 cycles(1-6 cycles), Response rate, local control rate, survival and complications were analysed retrospectively. Results : Two-year overall survival rate and median survival were $15.8{\%}$ and 13.5 months. Response rates were as follows complete remission(CR) 5($25{\%}$): partial remission a(PRa) 7($35{\%}$): partial remission b(PRb) 7($35{\%}$), no response(NR) 1($5{\%}$). Patterns of failure were as follows; local failure 13($65{\%}$), local and distant failure 3($15{\%}$), distant failure 0($0{\%}$). Ultimate local control rate was $20{\%}$. Treatment related complications included esophageal ulcer in two patients and esophageal stricture in one. Conclusion : Though poor local conrol rate, median survival was improved as compared with previous results of radiation therapy alone(8months) and chemoradiation combined treatment(11 months) in Yonsei Cancer Center High-dose-rate intraluminal brachytherapy following external irradiation is an effective treatment modality with acceptable toxicity in esophageal cancer.

  • PDF

The Role of the Soft Law for Space Debris Mitigation in International Law (국제법상 우주폐기물감축 연성법의 역할에 관한 연구)

  • Kim, Han-Taek
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.30 no.2
    • /
    • pp.469-497
    • /
    • 2015
  • In 2009 Iridium 33, a satellite owned by the American Iridium Communications Inc. and Kosmos-2251, a satellite owned by the Russian Space Forces, collided at a speed of 42,120 km/h and an altitude of 789 kilometers above the Taymyr Peninsula in Siberia. NASA estimated that the satellite collision had created approximately 1,000 pieces of debris larger than 10 centimeters, in addition to many smaller ones. By July 2011, the U.S. Space Surveillance Network(SSN) had catalogued over 2,000 large debris fragments. On January 11, 2007 China conducted a test on its anti-satellite missile. A Chinese weather satellite, the FY-1C polar orbit satellite, was destroyed by the missile that was launched using a multistage solid-fuel. The test was unprecedented for having created a record amount of debris. At least 2,317 pieces of trackable size (i.e. of golf ball size or larger) and an estimated 150,000 particles were generated as a result. As far as the Space Treaties such as 1967 Outer Space Treaty, 1968 Rescue Agreement, 1972 Liability Convention, 1975 Registration Convention and 1979 Moon Agreement are concerned, few provisions addressing the space environment and debris in space can be found. In the early years of space exploration dating back to the late 1950s, the focus of international law was on the establishment of a basic set of rules on the activities undertaken by various states in outer space.. Consequently environmental issues, including those of space debris, did not receive the priority they deserve when international space law was originally drafted. As shown in the case of the 1978 "Cosmos 954 Incident" between Canada and USSR, the two parties settled it by the memorandum between two nations not by the Space Treaties to which they are parties. In 1994 the 66th conference of International Law Association(ILA) adopted "International Instrument on the Protection of the Environment from Damage Caused by Space Debris". The Inter-Agency Space Debris Coordination Committee(IADC) issued some guidelines for the space debris which were the basis of "the UN Space Debris Mitigation Guidelines" which had been approved by the Committee on the Peaceful Uses of Outer Space(COPUOS) in its 527th meeting. On December 21 2007 this guideline was approved by UNGA Resolution 62/217. The EU has proposed an "International Code of Conduct for Outer Space Activities" as a transparency and confidence-building measure. It was only in 2010 that the Scientific and Technical Subcommittee began considering as an agenda item the long-term sustainability of outer space. A Working Group on the Long-term Sustainability of Outer Space Activities was established, the objectives of which include identifying areas of concern for the long-term sustainability of outer space activities, proposing measures that could enhance sustainability, and producing voluntary guidelines to reduce risks to long-term sustainability. By this effort "Guidelines on the Long-term Sustainability of Outer Space Activities" are being under consideration. In the case of "Declaration of Legal Principles Governing the Activities of States in the Exp1oration and Use of Outer Space" adopted by UNGA Resolution 1962(XVIII), December 13 1963, the 9 principles proclaimed in that Declaration, although all of them incorporated in the Space Treaties, could be regarded as customary international law binding all states considering the time and opinio juris by the responses of the world. Although the soft law such as resolutions, guidelines are not binding law, there are some provisions which have a fundamentally norm-creating character and customary international law. In November 12 1974 UN General Assembly recalled through a Resolution 3232(XXIX) "Review of the role of International Court of Justice" that the development of international law may be reflected, inter alia, by the declarations and resolutions of the General Assembly which may to that extend be taken into consideration by the judgements of the International Court of Justice. We are expecting COPUOS which gave birth 5 Space Treaties that it could give us binding space debris mitigation measures to be implemented based on space debris mitigation soft law in the near future.

High-Dose-Rate Brachytherapy for Uterine Cervical Cancer : The Results of Different Fractionation Regimen (자궁경부암의 고선량률 근접치료 : 분할선량에 따른 결과 비교)

  • Yoon, Won-Sup;Kim, Tae-Hyun;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.228-236
    • /
    • 2002
  • Purpose : Although high-dose-rate (HDR) brachytherapy regimens have been practiced with a variety of modalities and various degrees of success, few studies on the subject have been conducted. The purpose of this study was to compare the results of local control and late complication rate according to different HDR brachytherapy fractionation regimens in uterine cervical cancer patients. Methods and Materials : From November 1992 to March 1998, 224 patients with uterine conical cancer were treated with external beam irradiation and HDR brachytherapy. In external pelvic radiation therapy, the radiation dose was $45\~54\;Gy$ (median dose 54 Gy) with daily fraction size 1.8 Gy, five times per week. In HDR brachytherapy, 122 patients (Group A) were treated with three times weekly with 3 Gy to line-A (isodose line of 2 cm radius from source) and 102 patients (Group B) underwent the HDR brachytherapy twice weekly with 4 or 4.5 Gy to line-A after external beam irradiation. Iridium-192 was used as the source of HDR brachytherapy. Late complication was assessed from grade 1 to 5 using the RTOG morbidity grading system. Results : The local control rate (LCR) at 5 years was $80\%$ in group A and $84\%$ in group B (p=0.4523). In the patients treated with radiation therapy alone, LCR at 5 years was $60.9\%$ in group A and $76.9\%$ in group B (p=0.2557). In post-operative radiation therapy patients, LCR at 5 years was $92.6\%$ In group A and $91.6\%$ in group B (p=0.8867). The incidence of late complication was $18\%$ (22 patients) and $29.4\%$ (30 patients), of bladder complication was $9.8\%$ (12 patients) and $14.7\%$ (15 patients), and of rectal complication was $9.8\%$ (12 patients) and $21.6\%$ (22 patients), in group A and B, respectively. Lower fraction sized HDR brachytherapy was associated with decrease in late complication (p=0.0405) (rectal complication, p=0.0147; bladder complication, p=0.115). The same result was observed in postoperative radiation therapy patients (p=0.0860) and radiation only treated patients (0=0.0370). Conclusion : For radiation only treated patients, a greater number of itemized studies on the proper fraction size of HDR brachytherapy, with consideration for stages and prognostic factors, are required. In postoperative radiation therapy, the fraction size of HDR brachytherapy did not have much effect on local control, yet the incidence of late complication increased with the elevation in fraction size. We suggest that HDR brachytherapy three times weekly with 3 Gy could be an alternative method of therapy.

Removing High Concentration Organic Matters by Using Electrolysis (전기분해에 의한 고농도 유기물질 제거 특성)

  • Gil, Dae-Soo;Lee, Byung-Hun;Lee, Jea-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.251-264
    • /
    • 2000
  • Organic removal from synthetic wastewater by electrochemical methods was investigated with various operating parameters, such as current density, retention time, electrode gap and $Cl^-/COD_{Cr}$ ratio. In electrolysis, dioxide iridium coated titanium ($IrO_2/Ti$) and stainless steel plate were used for anode and cathode respectively. The $COD_{Cr}$ removal efficiencies between plate type anode and net type anode were about same effect, but electrolytic power using net type anode is low than plate type anode. The $Cl^-/COD_{Cr}$ ratio was about $1.3kgCl^-/kgCOD_{Cr}$ when organic removal obtained 70 %, $Cl^-/COD_{Cr}$ ratio needs $2.2kgCl^-/kgCOD_{Cr}$ so as to organic completely remove. The removal efficiency of organics increased with current density, retention time and $Cl^-/COD_{Cr}$ ratio, but decreased with increasing electrode gap. The relationship of operating conditions and $COD_{Cr}$ removal efficiencies are as follows. $$COD_{Cr}(%)=80.0360(Current\;density)^{0.4451}{\times}(HRT)^{0.8102}{\times}(Gap)^{-0.4915}{\times}(Cl^-/COD_{Cr})^{0.5805}$$ There existed a competition between the removals for $COD_{Cr}$ and ammonium during electrolysis, the removal of ammonium was shown to be dominant and $COD_{Cr}$ removal was low. But $COD_{Cr}$ removal was raised as addition of alkalinity.

  • PDF

Platinum complex oxide electrode catalyst for the solubilization of sewage sludge (하수슬러지 가용화 위한 백금족 복합 산화물 촉매 전극 개발)

  • Yoo, Jaemin;Kim, Hyunsook;pak, Daewon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.352-360
    • /
    • 2016
  • The purpose of this study was to determine the electrochemical properties develop DSA electrode for sewage sludge solubilization. Using Ir as a main catalyst, the catalyst selected for the sewage sludge solubilization durability and proceeds to functional electrode suitable for sewage sludge electrolysis experiment were obtained the following results. Less mass reduction of the sintering temperature of the main catalyst, Ir coated electrodes, the endothermic reaction zone $300^{\circ}C$ to $500^{\circ}C$, which was selected from a range of experiments. The efficiency of the catalyst results came up to $350^{\circ}C$ best. Each Binder stars (Ta, Sn, W) in this experiment was the biggest catalyst efficiency at $350^{\circ}C$. Used as a binder, $TaCl_5$, $SnCl_4$, $WCl_6$ of the Ta and without affecting the other characteristics of the main catalyst than Sn, W. For the 50% $IrO_2$ electrode is 1.4 V (vs. Ag / AgCl) in a current of about $29mA/cm^2$ was caused to evaluate the effectiveness of the electrode.