고(高) 에너지 전자선(電子線) 치료시(治療時) 체내(體內) 공동(空洞)으로 인(因)한 선량분포(線量分布)의 변동(變動) (Perturbation of Dose Distributions for Air Cavities in Tissue by High Energy Electron)

  • 추성실;이도행;최병숙
    • Journal of Radiation Protection and Research
    • /
    • 제1권1호
    • /
    • pp.22-30
    • /
    • 1976
  • The perturbation of dose distribution adjacent to cavities in high energy electron has shown that the percentage of dose increase varies markedly as a function of the build-up layer, the length and thickness of the cavities, and the electron energy. The dose distribution showed that cavities similar in size to those encountered in the head and neck measured by industrial film dosimetry and corrected by ionization chambers. The most increased doses by measuring are resulted in a localized dose of up to 130% of that measured at the depth of maximum dose within a homogeneous tissue equivalent phantom. The measured values and correction factors of dose perturbation due to air cavities showed in diagrams and would be summarized as follows. 1. In $8{\sim}12MeV$ electron beams, the most marked dose is observed when the build-up layer thickness is 0.5cm and cavity volume is $2{\times}2{\times}2cm^3$. 2. The highest dose point is located under cavity when the energy is increased and cavity length is longer. 3. The cavity length at which the maximum percentage dose occurs decreases with increasing energy. 4. The highest percentage cavity doses are obtained when the energy is high, the build-up layer is thin, the thickness of the cavity is large, and the length of the cavity is approximately 1 to 3cm. 5. The doses of upper portion of cavity are less than the standard dose distribution as 5 to 10%. 6. The maximum range of electron beam are extended as much as thickness of cavity. 7. A cavity having a length of 5cm closely approximates a cavity of infinite length.

  • PDF

Comparison of Air Kerma and Absorbed Dose to Water Based Protocols for High Energy Photon Beams: Theoretical and Experimental Study

  • Shin, Dong-Oh;Kim, Seong-Hoon;Seo, Won-Seop;Park, Sung-Yong;Park, Jin-Ho;Kang, Jin-Oh;Hong, Seong-Eon;Ahn, Hee-Kyung
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.241-243
    • /
    • 2002
  • New types of protocols have been recently in development, all based on an absorbed dose-to-water with the aim of improving the accuracy of measurements of absorbed dose to water. IAEA TRS-277, the air-kerma standard-based present protocol, and IAEA TRS-398 and AAPM TG-51, the absorbed dose-to-water standard-based new one, were studied and compared theoretically and experimentally for photon beams of 6, 10, and 15 MV. NE 2571 and 3 Farmer types of ionization chambers in widely commercial use were used to determine an absorbed dose to water at the reference depth in water. Two different kinds of calibration factors were given respectively for every chamber calibrated in $\^$60/CO gamma ray beams from a Korean Secondary Standard Dosimetry Laboratory (KFDA). This work shows that there is around 1 % of difference of absorbed doses measured between two different types of calibration systems owing to different physical parameters and reference conditions used. We hope this work to help form the basis on development of new type of protocol in Korea.

  • PDF

Proton Beam Dosimetry Intercomparison

  • Fukumura, Akifumi;Kanai, Tatsuaki;Kanematsu, Nobuyuki;Yusa, Ken;Maruhashi, Akira;Nohtomi, Akihiro;Nishio, Teiji;Shimbo, Munefumi;Akagi, Takashi;Yanou, Toshihiro;Fukuda, Shigekazu;Hasegawa, Takashi;Kusano, Yohsuke;Masuda, Yasutaka
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.252-254
    • /
    • 2002
  • A new protocol for dosimetry in external beam radiotherapy is published by the Japan Society of Medical Physics (JSMP) in 2002. The protocol deals with proton and heavy ion beams as well as photon and electron beams, in accordance with IAEA Technical Report Series No. 398. To establish inter-institutional uniformity in proton beam dosimetry, an intercomparison program was carried out with the new protocol. The absorbed doses are measured with different cylindrical ionization chambers in a water phantom at a position of 30-mm residual range for a proton beam, that had range of 155 mm and a spread out Bragg peak (SOBP) of 60-mm width. As a result, the intercomparison showed that the use of the new protocol would improve the +/- 1.0 % (one standard deviation) and 2.7 % (maximum discrepancy) differences in absorbed doses stated by the participating institutions to +/- 0.3% and 0.9 %, respectively. The new protocol will be adopted by all of the participants.

  • PDF

모니터 전리함 시작품 개발과 기초 성능 평가 (Development of Monitor Chamber Prototype and Basic Performance Testing)

  • 이무진;임희진;이만우;이준규;이동주;강상구;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제26권2호
    • /
    • pp.99-105
    • /
    • 2015
  • 모니터 전리함은 의료용 선형가속기에서 방출되는 방사선의 세기와 출력 제어를 위하여 사용된다. 본 연구에서는 가속기 기반 방사선 발생장치의 제어 시스템 개발에 사용하기 위하여 모니터 전리함 시작품을 개발하였다. 개발한 모니터 전리함은 평행 평판형 전리함 형태로서 독립적 작동이 가능한 두 개의 전리함으로 구성되어 있으며, 전극의 재료는 방사선의 감쇠를 최소화하기 위하여 얇은 연성인쇄회로기판이 사용되었다. 전리함의 시험을 위하여 코발트-60 방사선원을 이용하여 측정된 전하의 포화특성과 선형성과 같은 선량학적 특성을 평가하였다. 결과적으로 개발된 시작품이 기본 성능을 만족하며 추가 연구의 가능성을 확인하였다.

6MV 광자선에서 측정조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교 (The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams)

  • 김회남
    • 대한방사선치료학회지
    • /
    • 제10권1호
    • /
    • pp.11-22
    • /
    • 1998
  • The absolute absorbed dose can be determined according to the measurement conditions ; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of $10{\times}10cm$ field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations on phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG2l and IAEA protocol. The differences between two protocols are within $1\%\;while\;the\;average\;value\;of\;IAEA\;protocol\;was\;0.5\%$ smaller than TG2l protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within $1\%,\;but\;individual\;discrepancies\;are\;in\;the\;range\;of\;-2.5\%\;to\;1.2\%$ depending upon the choice of measurement combination. The largest discrepancy of $-25\%$ was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coefficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, It shows that absorbed dose could be affected by phantom material other than water.

  • PDF

평행평판형이온함의 교차교정 시 전자선 선질에 따른 흡수선량 결정에 대한 연구 (Study on Absorbed Dose Determination of Electron Beam Quality for Cross-calibration with Plane-parallel Ionization Chamber)

  • 라정은;신동오;박소현;정호진;황의중;안성환;임영경;김동욱;윤명근;신동호;이세병;서태석;박성용
    • 한국의학물리학회지:의학물리
    • /
    • 제20권2호
    • /
    • pp.97-105
    • /
    • 2009
  • 물 흡수선량표준을 기반으로 하는 선량측정 프로토콜에서는 전자선의 선질결정 지표는 $R_{50}$이며, 선량측정의 정확성을 향상시키기 위하여 전자선의 기준 에너지가 $R_{50}$>7 $g/cm^2$ (E${\gtrsim}$16 MeV)인 고에너지 전자선에서 표준기관에 소급성이 있는 원통형이온함의 물흡수선량교정계수을 이용한 평행평판형이온함의 교차교정을 권고하고 있다. 그러나 이러한 조건을 만족하는 고에너지 전자선은 모든 치료기관에서 보유하기가 어려운 실정이다. 따라서 본 연구에서는 평행평판형이온함의 교차교정 시 16 MeV 이상의 고 에너지 전자선뿐 아니라 12 MeV 이하의 전자선 에너지에서 얻은 평행평판형이온함의 교정계수를 이용하여 선량차이를 각각 비교하였다. 전자선 선량측정은 PTW 30013, Wellhofer FC65G의 Farmer형 원통형이온함과 PTW 34001, Wellhofer PPC40의 Roos형 평행평판형이온함을 이용하였으며 물팬텀내 기준깊이 $Z_{ret}=0.6R_{50}-0.1$(cm)에 원통형이온함과 평행평판형이온함을 같은 위치에 놓고 교차교정을 실시하였다. 교차교정 선질 20 MeV에서 결정된 교정계수를 적용한 물 흡수선량과 전자선에너지 12, 16 MeV에서의 물 흡수선량 차이는 0.2% 이내로 비교적 잘 일치하는 연구결과를 보였다. 그러므로 교차교정 선질 차이에 의한 흡수선량 값 상호 비교한 결과는 측정 불확도내에서 잘 일치하고 있어 각 기관에서 보유하고 있는 의료용가속기의 최고 전자선 선질에서의 교차교정도 유효하다고 사료된다.

  • PDF

사이버나이프 출력인자 분석: 전리함, 다이오드 검출기 및 필름 (Analysis of Relative Output Factors for Cyberknife: Comparison of Son Chambers, Diode Detector and Films)

  • 장지선;신동오;최병옥;이태규;최일봉;김문찬;권수일;강영남
    • 한국의학물리학회지:의학물리
    • /
    • 제17권1호
    • /
    • pp.47-53
    • /
    • 2006
  • 사이버나이프에 대한 정확한 선량측정은 정위방사선수술 전 과정에서 중요한 역할을 하고 있다. 본 연구에서는 여러 가지 검출기를 이용하여 사이버나이프의 상대적인 출력인자 값에 대하여 평가하고자 하였다. 사이버나이프는 12개 조준기를 사용하고 있으며, 이들 조준기에 대한 출력인자 값은 6개의 검출기(다이오드 검출기, X-Omat V 필름, Gafchromic EBT 필름, 0.015 cc, 0.125 cc, 0.6 cc 전리함)를 사용하여 측정하였다. 다이오드 검출기와 전리함은 물팬텀을 이용하여 선원과 표면 간의 거리 80 cm, 최대선량깊이인 1.5 cm에서 측정하였고 필름은 고체팬텀을 이용하여 물팬텀과 동일한 위치에서 측정하였다. 각 조준기의 출력인자는 사이버나이프의 최대 조사면의 크기인 직경 60 mm 조준기의 출력인자 값에 대하여 규격화하였다. 조준기의 크기가 30 mm 이상인 경우 0.6 cc 전리함을 제외하고 다른 검출기에서 0.5% 이내로 상호 잘 일치하였다. 그러나 15 mm 이하의 조준기에서는 출력인자 값이 검출기의 종류에 따라 다소 차이가 있음을 확인하였다. 즉, 다이오드 검출기와 Gafchromic 필름 경우 5 mm 조준기의 출력인자는 각각 $0.656{\pm}0.009$$0.777{\pm}0.013$이었다. 전리함과 다이오드 검출기에서 이러한 차이는 깊이에 따라 선량률 변화가 급격하고 측방쪽으로의 전자평형상태(lateral electronic equilibrium)가 이루어지지 않은 것으로 기인된다. 그러므로 Gafchromic EBT 필름이 사이버나이프 출력인자 값을 결정하는데 다른 검출기에 비하여 보다 정확하다고 사료된다.

  • PDF

선량 중첩 방식을 이용한 동적 배기 조사면의 특성 연구 (Commissionning of Dynamic Wedge Field Using Conventional Dosimetric Tools)

  • 이병용;나상균;최은경;김종훈;장혜숙;김미화
    • Radiation Oncology Journal
    • /
    • 제15권1호
    • /
    • pp.71-78
    • /
    • 1997
  • 목적 :동적 쐐기 조사면 측정을 다중 검출기 시스템과 같은 특수한 장치없이 보편적인 방사선 측정 방법을 사용하여 시행할 수 있는 방법을 고안, 수행하였다. 대상 및 방법 : $15^{\circ},\;30^{\circ},\;45^{\circ},\;60^{\circ}$의 동적 쐐기각(dynamic wedge angle)과 6MV와 15MV인 광자선을 발생시키는 선형 가속기(CL 2100 C/D)를 이용하여 wedge transmission factor 및 percentage depth dose(PDD, 선량 프로파일을 측정하였다. Wedge transmission factor는 6MV, 15MV인 광자선과 $15^{\circ},\;30^{\circ},\;45^{\circ},\;60^{\circ}$의 4개의 동적 쐐기각에 대해서 $4\times4cm^2-20\times20cm^2$까지 1-2cm간격의 정사각형 조사면과 Y-field가 4cm, 20cm일 때 여러개의 X-field에 대한 각각의 직사각형 조사면에서 측정하였다. 또한 동적 쐐기의 구간별 치료표(Segmented Treatment Table, STT)값을 이용하여 wedge factor를 계산해 내었다. PDD는 필름 dosimetry로 구하였는데 개방 조사면에 대해 전리함과 필름으로 PDD를 구한 후 필름의 환산값을 알아내어 쐐기 조사면에 대한 필름 dosimetry로 PDD를 구하여 필름 환산값으로 전리함을 통해 얻을 수 있는 실제 PDD를 구하였다. 선량 프로파일은 비대칭 정지 조사면을 선택적으로 전리함을 이용하여 측정하고 이때 얻은 측정치인 소구간 프로파일과 STT를 이용하는 선량 분포 중칩 방식으로 구하였다. 결과 : wedge transmission factor의 측정치와 STT를 이용하여 구한 계산치를 비교한 결과 실험 오차 범위내에서 거의 일치하였다. 또한 직사각형 조사면에서의 wedge transmission factor 변화를 측정한 결과 동일한 Y-field에 대해서 직사각형 조사면은 정사각형 조사면에서의 wedge factor와 같았다. PDD는 필름 방사선 측정값의 보정으로 개방 조사면에서 PDD와 동적 쐐기 조사면에서 PDD 사이의 차이는 무시될 수 있다. 그리고 전리함의 측정으로부터 중칩 방식으로 얻어진 동적 쫴기의 선량 프로파일은 필름 dosimetry로 얻은 동적 쐐기의 선량 프로파일과 비교한 결과 최대 2% 이내 정확도의 허용 오차 영역에 들어옴을 볼 수 있었다. 결론 :동적 조사면의 특성으로 동적 쐐기 측정에서의 정보 수집을 위하여 모든 조사면에서의 방대한 측정과 그로인한 장시간의 소비, 또한 동적 쐐기 측정을 위한 특수한 장치가 필요하지만 보편적으로 사용하는 측정 장치, 즉 단일 검출기와 필름 방사선 측정 방법으로 충분히 용이하게 행할 수 있었다.

  • PDF

$N_{dw}{^{Co-60}}$이 정의되지 않은 원통형 이온전리함을 이용한 고에너지 광자선의 임상적 출력선량 결정 (Practical Output Dosimetry with Undefined $N_{dw}{^{Co-60}}$ of Cylindrical Ionization Chamber for High Energy Photon Beams of Linear Accelerator)

  • 오영기;최태진;송주영
    • 한국의학물리학회지:의학물리
    • /
    • 제23권2호
    • /
    • pp.114-122
    • /
    • 2012
  • 선형가속기의 출력선량의 평가는 표준선원에 의한 조사선량교정인수 $N_x$나 공기커마교정인수 $N_k$또는 더 나아가 물흡수 선량교정인수를 가진 공동전리함을 이용하여 이루어지며, 선량프로토콜에 따라 교정인수가 다르다. $N_x$를 사용하는 TG-21 프로토콜은 Bragg-Gray 공동이론에 근거하여 기체흡수교정인수를 구하고 공동전리함의 내경과 벽재질과 두께, 공동길이 등에 따라 보정인수가 정해지므로 다소 복잡한 계산절차를 가지므로 누적오차가 발생할 수 있다. TG-51은 물 흡수선량교정인수를 이용하므로써 복잡한 절차를 크게 줄여 계산오차를 피할 수 있게 되었다. 대개 1차표준국에서는 $N_x$$N_k$$N_{dw}{^{Co-60}}$을 제공하여 왔으므로, $N_{dw}$가 정해지지 않은 TM31010 계열의 공동전리함에 대해 $N_x$ 또는 $N_k$로 TG-21을 이용하여 $N_{dw}$를 결정하는 프로그램을 준비했으며, 기존 $N_x$$N_{dw}$가 제공된 IC-15 전리함의 것과 비교하여 좋은 일치결과를 얻었다. 반면에 TM31010은 이차표준국(SSDL, Secondary Standard Dosimetry Laboratory)에서 제공된 $N_k$$N_{dw}$를 구한 결과 우송형 열형광소자(TLD, Thermo Luminescence Device)에 의한 출력선량모니터 결과 불안정한 결과를 계기로 한국 표준과학연구원의 1차 표준선량시험(PSDL)의 교정인수와 비교한 결과 0.4%와 -2.8%로 각각 나타나 SSDL의 교정인수와 차이를 보여, $N_{dw}$가 정해져 있지 않거나 평가선량이 의심스러울 때는 선량프로토콜의 절차에 과한 세밀한 검토와 전리함의 교정계수에 대한 교차점검이 필요함을 알았다.

Cs-137 감마선의 선량측정을 위한 TRS-398 선질인자 결정에 관한 연구 (Determination of TRS-398 Quality Factors for Cs-137 Gamma Rays in Reference Dosimetry)

  • 강상구;이동주;강영록;김정기;정동혁
    • 한국의학물리학회지:의학물리
    • /
    • 제25권3호
    • /
    • pp.123-127
    • /
    • 2014
  • Cs-137 방사선 조사기는 방사선생물 연구 분야에서 시료에 방사선 조사장치로 널리 사용되고 있다. 이러한 방사선 조사기 사용에 있어 시료에 조사되는 흡수선량의 평가는 향상된 연구 결과를 얻기 위하여 중요하다. 국제원자력기구의 TRS-277 또는 TRS-398 같은 선량측정 프로토콜은 이러한 목적에 적합하다. 그러나 현재 가장 실용적인 선량측정 프로토콜로 알려진 TRS-398의 경우에 Cs-137 선원에 대한 선질인자가 제공되지 않는 단점이 있다. 본 연구에서는 이전에 보고된 고에너지 방사선치료용 광자선에 대한 계산방법을 이용하여 Cs-137 선원의 선질인자를 결정하였으며 15종의 파머형 전리함에 대하여 선질인자를 결정하였다. 결과로서 대상전리함에 대한 Cs-137 선원에서 선질인자는 0.998에서 1.002 범위를 보였다. 이 결과는 Cs-137 선원을 사용하는 분야에서 물흡수선량 측정과 선량계의 교정에 유용하게 사용할 수 있을 것으로 본다.