• 제목/요약/키워드: Ion selective electrodes

검색결과 102건 처리시간 0.029초

Beryllium(II) Recognition by Allosteric Effects in 1,2-Ethylenedioxybenzene Based Ditopic Receptors

  • Kim, Dong-Wan;Kim, Jung-Hwan;Hwang, Jae-Young;Choi, Myong-Yong;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권8호
    • /
    • pp.2643-2647
    • /
    • 2011
  • Efficient ditopic receptor, uranyl(II) N,N'-(ethylenedioxy)benzenebis(salicylideneimine) (3) for beryllium ion has been obtained upon functionalization of 1,2-ethylenedioxybenzene (1) with a uranyl-salphen (salphen = N,N'-phenylenebis(salicylideneimine)) unit. Binding affinities of the receptor, 3 in AN-DMSO (v/v 95:5) solution have been measured for alkali and alkaline earth metal ions by conductometry comparing 1. The results showed that both monotopic 1 and ditopic receptor 3 were selective for $Be^{2+}$ ions over other cations, while especially 3 that can complex both with cations (coordinated to basic oxygen of ethylenedioxybenzene) and anions (coordinated to the Lewis acidic uranyl center) results in an increase of the stability constants by a factor of $10^{2.42}$ with respect to 1. Furthermore, the $Be^{2+}$-3 interactions are demonstrated by $^1H$ NMR experiments in highly polar solvent medium, DMSO-$d_6$. Higher selectivities were also observed for $Be^{2+}$ when the ditopic receptor, 3 was incorporated into PVC membranes and tested as ion selective electrodes at neutral pH.

The Potentiometric Performance of Mercury (II) Ion-Selective Electrode Based on Tetracycline Antibiotics

  • Baek, Jong-Gyu;Rhee Paeng, In-Sook
    • 전기화학회지
    • /
    • 제11권1호
    • /
    • pp.59-63
    • /
    • 2008
  • Poly (vinylchloride) (PVC) membrane electrodes based on neutral carrier, tetracycline was prepared as an active sensor for Hg(II) ion, and tested in different contents of the potassium tetrakis (4-chlorophenyl) borate (KTpClPB) as lipophilic salt. Bis (2-ethylhexyl) sebacate (DOS), bis(l-butylpentyl) adipate (BBPA), 2-nitrophenyl octyl ether (NPOE) and dibutyl phthalate (DBP) were used as diverse plasticizing solvent mediators. This electrode shows excellent potentiometric response characteristics and display good linearity with log $[Hg^{+2}]$ versus EMF response, over a range of concentrations between $10^{-7}$ and $10^{-3}M$. With 30.8mV/decade Nernstian slope, the detection limit was $6.9{\times}10^{-9}M$ and the response time was less than 20s. The proposed electrode yields very good selectivity for mercury (II) ion over many cations such as alkali, alkaline earth, transition and heavy metal ions. And it shows a very stable potential values in a wide pH range. This reliable electrode prepared was kept at least a month without considerable alteration in their response to Hg (II) ion.

중성운반체를 이용한 K+ 이온선택성 PVC막 전극 (K+ Ion-Selective PVC Membrane Electrodes with Neutral Carriers)

  • 김용렬;조경섭;강안수
    • 공업화학
    • /
    • 제9권5호
    • /
    • pp.734-741
    • /
    • 1998
  • 본 연구에서는 전극전위 분석법을 사용하여 중성운반체로 dibenzo-18-crown-6(D18Cr6)와 valinomycin(Val)을 이용하여 $K^+$ 이온선택성 PVC막 전극의 막과 용액계면에서의 전극특성을 검토하였다. PVC막에서 감응물질(운반체)에 기본전해질의 혼입 (doping)여부, 감응물질의 종류와 함량, 가소제, 막두께 및 이온의 활동도변화에 따른 전극의 기울기, 선형응답범위 한계측정농도 및 방해이온에 따른 선택계수 등 전극특성을 검토하였다. 중성운반체로 D18Cr6, Val을 $K^+$ 이온으로 착체형성하여 사용하였고, 가소제로 dibutylphthalate(DBP), dioctyl sebacate(DOS) 및 dibutyl sebacate(DBS)를, 혼입제인 기본전해질로 potassium tetraphenylborate (KTPB) 및 용매로 THF를 지지체로 PVC를 이용하여 막을 제조하였다. 운반체의 최적 함량은 D18Cr6와 Val의 경우 3.23 wt %이었고, 가소제는 DBP가 가장 적절한 가소제이었다. 막두께에 대한 영향은 최적 막두께 이상에서는 막두께가 얇아질수록 전극특성이 좋아졌으나, 막두께가 이 이하로 얇아지면 운반체의 용출, 막의 강도 등이 작용하여 전극특성이 나빠짐을 알 수 있었다. D18Cr6의 경우 $K^+$ 이온에 대한 혼합용액법에 의한 선택계수 서열은 다음과 같았다: $NH_4{^+}>Ca^{2+}>Mg^{2+}>Na^+$.

  • PDF

The Composition Dependence Selectivity Changes by Plasticizer at the Cation Sensors Based on Tetracycline Antibiotics

  • Baek, Jong-Gyu;Kim, Jin-San;Paeng, Insook Rhee;Paeng, Ki-Jung
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권1호
    • /
    • pp.165-167
    • /
    • 2008
  • The performances of tetracycline based cation selective polymeric membrane electrodes of many sets with different plasticizers were investigated as the selectivity of ion-selective electrodes and optodes are greatly influenced by membrane solvent and also controlled by plasticizers. The membrane 1 with Bis(2-ethylhexyl) sebacate (DOS) and additive shows good potentiometric performance toward Ca2+ (slope: 27.8 mV per decade; DL: -4.52) including selectivity. Contrastingly, membrane 4 with Dibutyl phthalate (DBP) shows near-Nernstian response, it has also shown the best measuring range and detection limit for Ca2+ (29.5 mV and -5.10) and Mg2+ (24.4 mV and -5.04) and the least selectivity has been also observed between Ca2+ and Mg2+. When the membrane 1 and 4 were used together to flow system, we could determine the concentration of Ca2+ and Mg2+, simultaneously.

${\beta}-Ag_3SI$ 단결정막 전극에 관한 연구 (${\beta}-Ag_3SI$ Single Crystal Membrane Electrode)

  • 신두순;이선천
    • 대한화학회지
    • /
    • 제28권2호
    • /
    • pp.86-94
    • /
    • 1984
  • ${\beta}-Ag_3SI$의 단결정을 만들어 막전극으로의 응용을 살펴보았다. 그 결과 할로겐 이온들에 대해 감응함을 알았고, 분리용액법과 혼합용액법으로 할로겐 이온들에 대한 선택계수를 얻어 이론값과 비교검토 하였으며, 전위시간 곡선으로 부터 이 전극이 유리 전극기구에 의해 전도함을 알았고, 넓은 pH 범위에서 전위가 일정한 값을 가짐을 알았다. 한편 분석화학에의 응용을 살펴 본 결과 할로겐이온의 혼합용액에서 좋은 지시전극으로 사용할 수 있음을 알았다

  • PDF

금 입자 증착된 탄소나노튜브의 커패시턴스 증가 및 박막형 이온 선택성 전극으로서의 특성 평가 (Capacitance Enhancement and Evaluation of Gold-Deposited Carbon Nanotube Film Ion-Selective Electrode)

  • 김도연;손한별;임효령
    • 한국분말재료학회지
    • /
    • 제30권4호
    • /
    • pp.310-317
    • /
    • 2023
  • Small-film-type ion sensors are garnering considerable interest in the fields of wearable healthcare and home-based monitoring systems. The performance of these sensors primarily relies on electrode capacitance, often employing nanocomposite materials composed of nano- and sub-micrometer particles. Traditional techniques for enhancing capacitance involve the creation of nanoparticles on film electrodes, which require cost-intensive and complex chemical synthesis processes, followed by additional coating optimization. In this study, we introduce a simple one-step electrochemical method for fabricating gold nanoparticles on a carbon nanotube (Au NP-CNT) electrode surface through cyclic voltammetry deposition. Furthermore, we assess the improvement in capacitance by distinguishing between the electrical double-layer capacitance and diffusion-controlled capacitance, thereby clarifying the principles underpinning the material design. The Au NP-CNT electrode maintains its stability and sensitivity for up to 50 d, signifying its potential for advanced ion sensing. Additionally, integration with a mobile wireless data system highlights the versatility of the sensor for health applications.

안트라센을 포함하는 15-Crown-5 유도체를 이온선택성 물질로 이용한 칼륨이온의 전위차법 정량 (Potentiometric Determination of Postssium Ion Using 15-Crown-5 Derivatives with Anthracene for the Selective Material)

  • 배준용;이상봉;장승현;김의락
    • 대한화학회지
    • /
    • 제45권1호
    • /
    • pp.31-39
    • /
    • 2001
  • 새로이 합성한 15-Crown-5 유도체들을 칼륨이온의 전위차법 정량을 위한 중성운반체로 사용하였다. 다섯 가지 화합물 중에서N-(4'-benzo-15-crown-5-ether)-anthracene-9-imine이 가장 좋은 선택성과 안정성을 보였다. 칼륨이온을 전위차법으로 정량하기 위한 이온선 택성 막의 조성을 조사한 결과, 최적 조성은 중성운반체: PVC:가소제의 조성비가 1.0:33.0:66.0 wt% 이었다. 친유성 첨가제로 0.2wt% KTpClPB를 사용했을 때에 Nernstian 기울기가 많이 좋아졌고, 또 알칼리 및 알칼리 토류 금속에 대한 칼륨이온의 선택성이 크게 개선되었다. 특히 암모늄이온에 대한 칼륨 이온의 선택성은 $logK^{pot}_(K^+,NH_4^+}$=-2.59로 아주 좋은 값을 보였다. 이 전극의 감응시간은 $t_{100}$=5sec로서 짧은 시간에 많은 시료를 분석할 수 있고, 3주 이상 사용하여도 선택성과 분석 특성에 별다른 변화가 없었다.

  • PDF

아릴아민계의 중성운반체를 이용한 수소이온선택성 막전극 (Hydrogen ion-selective membrane electrodes based on arylamines as neutral carriers)

  • 정성숙;조동희;김재우;정구춘;박면용
    • 분석과학
    • /
    • 제9권1호
    • /
    • pp.78-83
    • /
    • 1996
  • Tribenzylamine(TBA), tetrabenzylethylenediamine(TBEDA), pentabenzyldiethylenetriamine(PBDETA)을 중성운반체로 이용한 막전극은 각각 pH 1~pH 9, pH 2~pH 12, pH 4~pH 12 범위에서 수소이온에 선택적이고 선형적인 감응을 나타내었다. TBA, TBEDA, PBDETA로 만든 막전극은 비공유전자쌍 수의 증가와 수소이온 선택성 사이에는 무관 하였고 각각에 대한 기울기는 43.8mV/pH, 46.9mV/pH, 43.6mV/pH를 나타냈다. 각 전극에 대하여 알칼리금속이온($Li^+$, $Na^+$, $K^+$) 및 알칼리토금속이온($Ba^{2+}$, $Ca^{2+}$, $Mg^{2+}$), 전이금속이온($Mn^{2+}$, $Co^{2+}$, $Ni^{2+}$, $Cu^{2+}$, $Zn^{2+}$)에 대한 방해이온을 측정하였다. 선택계수는 분리용액법을 이용하여 측정하였고 TBEDA를 이용한 막이 가장 좋은 결과를 나타내었다.

  • PDF