• Title/Summary/Keyword: Ion components

Search Result 583, Processing Time 0.031 seconds

A Study on Water-soluble Components in the Dustfall Matter at Cheju and Ullung Island (제주도와 울릉도의 강하분진중 수용성 성분에 관한 연구)

  • Choi, Jae-Cheon;Kim, San;Lee, Min-Young;Lee, Sun-Ki
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.331-337
    • /
    • 1995
  • This study was carried out to investigate the chemical composition of dustfall at Cheju(mean sea level; 71.7m, 33$^{\circ}$17'N, 126$^{\circ}$10'E) and Ullung island(mean sea level; 22.1m, 38$^{\circ}$29'N, 130$^{\circ}$54'E) from October 1993 to september 1994. The dustfall matter samples were collected by deposit gauges. The ionic components of each samples was analyzed by Ion Chromatograpy (Dionex 4000i), While heavy metals by Inductively Coupled Plasma Atomic Emission Spectrometry(ICP/AES; Shimadzu ICP-4). The results for seasonal variation of dustfall matter matter total amount, water-soluble ionic components and water-soluble ionic components total deposition amount to two sites were compared each other. The seasonal variations of dustfall amount at Ullung and Cheju island were found in order of Spring>Winter>Fall>Summer, and the maximum of dustfall amount were during the Yellow Sand period. Also, Total amount of water-soluble components except for $F^{[-10]}$ were high in Cheju more than Ullung island.more than Ullung island.

  • PDF

Development of Hard-wired Instrumentation and Control for the Neutral Beam Test Facility at KAERI

  • Jung Ki-Sok;Yoon Byung-Joo;Yoon Jae-Sung;Seo Min-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.359-365
    • /
    • 2006
  • Since the start of the KSTAR (Korea Superconducting Tokamak Advanced Research) project, Instrumentation and Control (I&C) of the Neutral Beam Test Facility (NB-TF) has been striving to answer diverse requests arising from various facets during the project's development and construction phases. Hard-wired electrical circuits have been designed, tested, fabricated, and finally installed to the relevant parts of the system. In relation to the vacuum system I&C, controlling functions for the rotary pumps, a Roots pump, two turbomolecular pumps, and four cryosorption pumps have been constructed. I&C for the ion source operation are the temperature and flow rate signal monitoring, Langmuir probe signal measurements, gradient grid current measurements, and arc detector circuit. For the huge power system to be monitored or safely operated, many temperature measurement functions have also been implemented for the beam line components like the neutralizer, bending magnet, ion dump, and calorimeter. Nearly all of the control and probe signals between the NB test stand and the control room were made to be transmitted through the optical cables. Failures of coolant flow or beam line vacuum pressure were made to be safely blocked from influencing the system by an appropriate interlock circuit that will shut down the extraction voltage application to the system or prevent damages to the vacuum components. Preliminary estimation of the beam power through the calorimetric measurement shows that 87.9% of the total power of the 60kV/18A beam with 200 seconds duration is absorbed by the calorimeter surface. Most of these I&C results would be highly appropriate for the construction of the main NBI facility for the KSTAR national fusion research project.

The Aerosol Characteristics in Coexistence of Asian Dust and Haze during 15~17 March, 2009 in Seoul (짙은 황사와 연무가 공존한 대기의 에어러솔 특성 - 2009년 3월 15~17일 -)

  • Lee, Hae-Young;Kim, Seung-Bum;Kim, Su-Min;Song, Seung-Joo;Chun, Young-Sin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.2
    • /
    • pp.168-180
    • /
    • 2011
  • The variation of the physicochemical properties of atmospheric aerosols in coexistence of the heavy Asian Dust and Haze observed from $15^{th}$ to $17^{th}$ March 2009 in Seoul was scrutinized through the mass and ion concentration observations and synoptic weather analysis. Although the ratio of PM1.0/PM10 was constant at 0.3 (which is typical during Asian Dust period in Korea) during the measurement period, both PM10 and PM1.0 mass concentrations were 3~6 times and 2~4 times higher than that of clear days, respectively. Water-soluble ion components accounted for 30~50% of PM10 and 50~70% of PM1.0 mass concentration. One of the secondary pollutants, $NO_3^-$ was found to be associated with $Ca^{2+}$ and $Na^+$ in coarse mode indicating that the aerosol derived from natural source was affected by anthropogenic pollutants. While the acidity of the aerosols increased in fine mode when the stagnation of weather patterns was the strongest (March $16^{th}$), the alkalinity increased in coarse mode when new air masses arrived with a southwestern wind after ending a period of stagnation (March $17^{th}$). In the selected case, SOR (Sulfur Oxidation Ratio, $nSO_4^{2-}/[nSO_4^{2-}+nSO_2]$) and NOR (Nitrogen Oxidation Ratio, $nNO_3^-/[nNO_3^-+nNO_2]$) values of ion components were higher than the general values during Asian Dust period. These results imply that dust aerosols could be mixed with pollutants transported from China even in heavy Asian Dust cases in Korea.

Near IR Luminescence Properties of Er-doped Sol-Gel Films (Er이 도핑된 졸-겔 코팅막의 발광특성)

  • Lim, Mi-Ae;Seok, Sang-Il;Kim, Ju-Hyeun;Ahn, Bok-Yeop;Kwon, Jeong-Oh
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.136-136
    • /
    • 2003
  • In fiber optic networks, system size and cost can be significantly reduced by development of optical components through planar optical waveguides. One important step to realize the compact optical devices is to develop planar optical amplifier to compensate the losses in splitter or other components. Planar amplifier provides optical gain in devices less than tens of centimeters long, as opposed to fiber amplifiers with lengths of typically tens of meters. To achieve the same amount of gain between the planar and fiber optical amplifier, much higher Er doping levels responsible for the gain than in the fiber amplifier are required due to the reduced path length. These doping must be done without the loss of homogeniety to minimize Er ion-ion interactions which reduce gain by co-operative upconversion. Sol-gel process has become a feasible method to allow the incorporation of Er ion concentrations higher than conventional glass melting methods. In this work, Er-doped $SiO_2$-A1$_2$ $O_3$ films were prepared by two different method via sol -Eel process. Tetraethylorthosilicate(TEOS)/aluminum secondary butoxide [Al (OC$_4$ $H_{9}$)$_3$], methacryloxypropylcnethoxysaane(MPTS)/aluminum secondary butofde [Al(OC$_4$ $H_{9}$)$_3$] systems were used as starting materials for hosting Er ions. Er-doped $SiO_2$-A1$_2$ $O_3$ films obtahed after heat-treating, coatings on Si substrate were characterized by X-ray din action, FT-IR, and N-IR fluorescence spectroscopy. The luminescence properties for two different processing procedure will be compared and discussed from peak intensity and life time.

  • PDF

Altered Pharmacokinetics and Hepatic Uptake of TBuMA in Ethynylestradio-Induced Cholestasis

  • Hong Soon-Sun;Choi Jong-Moon;Jin Hyo-Eon;Shim Chang-Koo
    • Archives of Pharmacal Research
    • /
    • v.29 no.4
    • /
    • pp.323-327
    • /
    • 2006
  • The objective of this study was to examine the pharmacokinetics of organic cations in intrahepatic cholestatic rats. A pretreatment with $17{\alpha}$-ethynylestradiol was used to induce intrahepatic cholestasis, and tributylmethylammonium (TBuMA) was used as a representative model organic cation. When $[^3H]$TBuMA was intravenously administered, the AUC value for TBuMA was significantly increased by $79\%$ in cholestasis, and its total systemic clearance was consequently decreased by $46\%$. In addition, the in vivo hepatic uptake clearance of TBuMA from the plasma to the liver was decreased by $50\%$ in cholestasis. The concentration of bile salts in plasma was increased by 2.1 fold in cholestatic rats. Since TBuMA forms ion-pair complexes with anionic components such as bile salts, the decreased hepatic uptake of TBuMA in cholestasis may be due to a change in endogenous components, e.g., bile salts in the plasma. In isolated normal hepatocytes, the uptake clearance for TBuMA in the presence of cholestatic plasma was decreased by $20\%$ compared with normal plasma. Therefore, we conclude that the inhibition of the hepatic uptake process by the cholestasis may be in part due to the increased formation of ion-pair complexes of TBuMA with bile salts in the plasma.

A Study on the Quality Assuranc of Chemical Analysis Data of Precipitation Samples (강수 분석자료의 신뢰성 검토에 관한 연구)

  • 강공언
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.3
    • /
    • pp.85-98
    • /
    • 1995
  • In order to ensure that all major cations and anions were accurately measured, the quality assurance checks of chemical analysis data by considering ion and conductivity balance of each precipitation sample were performed. To check the quality assurance of chemical analysis data, precipitation samples were collected by wet- only precipitation sampler at Seoul site and their chemical components were analyzed. By checking the problems for the screening methods of chemical analysis data used until recently, the f value expressed as the ratio of the sum of cations and anions equivalent concentration( $\Sigma $C/$\Sigma $A ) was found to be not ap priorate for data screening. Also, the scattering plot between cation and anion equivalent concentrations in each sample was found to show the general tendency of ion balance but was proved to not quantitate the standard of data screening at a set of samples of various concentration levels.4 more appropriate value was therefore required, h value is defined as (A-C)/C for C≥A and ( A-C)/A for C<4. This value was showed to check the ion balance in a viewpoint of quantitative as well as qualitative and to be useful in applying this expression to a measurement data set. However, the standard o( data screening must vary in response to the ion concentration of sample. In this study, the quality assurance of chemical analysis data was checked by considering both the ion balance evaluating by h value and the electrical conductivity. As these quality assurance checks were applied to Seoul data serf 67 valid samples were obtained. The result of statistical summary in the analytical parameter of precipitation samples collected for a certain period was found to be computed in the precipitation volume- weighted mean( VWM) rather than the arithmetic mean( AM), but PH In the VWM of hydrogen ion concentration. The annual VWM of pH values was 5.0(4.9 ∼ 5.1).

  • PDF

Determination of isoquinoline alkaloids by UPLC-ESI-Q-TOF MS: Application to Chelidonium majus L.

  • Jeong, Won Tae;Lim, Heung Bin
    • Analytical Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.379-389
    • /
    • 2017
  • In this study, we set up an analytical method that can be used for rapid and accurate determination of representative isoquinoline alkaloids in medicinal plants using UPLC-ESI-Q-TOF MS (ultra pressure liquid chromatography-electrospray ionization-quadrupole-time-of-flight mass spectrometry). The compounds were eluted on a C18 column with 0.1 % formic acid and acetonitrile, and separated with good resolution within 13 min. Each of the separated components was characterized by precursor ions (generated by ESI-Q-TOF) and fragment ions (produced by collision-induced dissociation, CID), which were used as a reliable database. We also performed method validation: analytes showed excellent linearity ($R^2$, 0.9971-0.9996), LOD (5-25 ng/mL), LOQ (17-82 ng/mL), accuracy (91.6-97.4 %) as well as intra- and inter-day precisions (RSD, 1.8-3.2 %). In the analysis of Chelidonium majus L., magnoflorine, coptisine, sanguinarine, berberine and palmatine were detected by matching retention times and characteristic fragment ion patterns of reference standards. We also confirmed that, among the quantified components, coptisine was present in the highest quantity. Furthermore, alkaloid profiling was carried out by analyzing the fragment ion patterns corresponding to peaks of unknown components. In this manner, protopine, chelidonine, stylopine, dihydroberberine, canadine, and nitidine were tentatively identified. We also proposed the molecular structure of the fragment ions that appear in the mass spectrum. Therefore, we concluded that our suggested method for the determination of major isoquinoline alkaloids by UPLC-Q-TOF can be useful not only for quality control, but also for rapid and accurate investigation of phytochemical constituents of medicinal plants.

A Study on the Ionic Components of Rain Water in Samchok-City Area (삼척지역 우수의 이온성분농도에 관한 연구)

  • 이승일;김승호;조기철;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.1
    • /
    • pp.23-28
    • /
    • 1996
  • In order to investigate the chemical components of acid precipitation at Samchok City in Korea, the rainwater was collected according to 3mm rainfall from september 1994 to december 1994. pH, electric conductivity were measured and ionic components were analyzed by Ion chromatography. As the analytical results, the average value were 6.27 for pH, 53.16 S/cm for E.C., the average concentration were 393.42 eq/1 for C $l^{[-10]}$ , 18.41 eq/1 for N $O_{3}$$^{[-10]}$ , 91.44 eq/1 for S $O_{4}$$^{2-}$, 335.92 eq/1 for N $a^{+}$, 65.66 eq/1 for N $H_{4}$$^{+}$, 18.22 eq/1 for $K^{+}$, 120.49 eq/1 for $Mg^{2+}$ and 147.04 eq/1 for $Ca^{2+}$. pH value correlated negatively with rainfall amount and the component of C $l^{[-10]}$ and N $a^{+}$ were transported to urban air by the seasalt. It showed that S $O_{4}$$^{2-}$ and N $O_{3}$$^{[-10]}$ had influence on acidity of precipitation, 73% and 27%, respectively, in this area. Ion Concentration of N $O_{3}$$^{[-10]}$ was higher than S $O_{4}$$^{2-}$ in the early rain, S $O_{4}$$^{2-}$ was higher than N $O_{3}$$^{[-10]}$ in the succeeding rain by multi-regration analysis. the percentages of removal by percipitation were higher in N $O_{3}$$^{[-10]}$ than in S $O_{4}$$^{2-}$./TEX> 2-/.

  • PDF

Changes in aerosol characteristics during 2006 ~ 2008 Asian dust events in Cheonan, Korea (2006 ~ 2008년 황사기간 중 천안시 대기 입자의 특성 변화)

  • Oh, Se-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.7
    • /
    • pp.1642-1647
    • /
    • 2009
  • Changes in aerosol characteristics during 2006 ${\sim}$2008 Asian dust events in Cheoan were investigated by measuring mass, ion and elemental concentrations of fine and coarse particles. The average mass concentrations of daily TSP, PM10, PM2.5 were 214.9, 160.3, and 95.9${\mu}\;g/m^3$during Asian dust events, which were 3.08, 2.58, and 1.95 times higher than Non-asian dust events. The maximum concentrations of TSP, PM10, and PM2.5 were 850.1, 534.4, and 233.3${\mu}\;g/m^3$, which were 12.19, 8.60, and 4.76 times higher, respectively. Increases in ion concentrations were not significant during Asian dust events, but elemental concentrations including soil components such as Fe, Al, Ti increased by 17.1 and 43.4 times for fine and coarse particles, respectively. The results clearly indicate that metallic components from soil constituents were the major components in Asian dusts sampled at Cheonan.

Effect of Acclimation Methods on Physiological Status of Pacific White Shrimp Litopenaeus vannamei Bred in Low Salinity Biofloc (저염분 바이오플락에서 사육한 흰다리새우(Litopenaeus vannamei)의 해수 순치방법에 따른 혈장성분 및 혈장삼투압 비교)

  • Jeon, Yu-Hyeon;Lee, Jong-Min;Kim, Su Kyung;Kim, Su-Kyoung
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.5
    • /
    • pp.761-768
    • /
    • 2021
  • This study was carried out to identify an effective method to acclimate low-salinity (4 psu) bred Litopenaeus vannamei (mean body weight 16±3.3 g) to sea water. The fast acclimation group (FA) was directly exposed to filtered sea water (32 psu) while the slow acclimation group (SA) was exposed to a slow increase in salinity. Shrimps were sampled at 0, 1, 3, 6, 12, 24 and 48 h for plasma analyses. The plasma components between experimental groups did not show significant differences. The hemolymph osmolality (HO) in FA increased significantly after 1 h (P<0.05), while in SA it started to increase slowly only at 24 h and reached a similar level to that of FA at 48 h. The levels of Na+ and Mg2+ ions were significantly different between the two treatments (P<0.05), but there was no significant difference in Ca2+ ion levels. We found that the different methods of acclimation of L. vannamei to sea water do not affect the plasma components significantly, but lead to changes in the HO and ion levels, it is considerable to acclimate gradually for at least two days.