• Title/Summary/Keyword: Ion chromatography (IC)

검색결과 75건 처리시간 0.03초

Degradation Phenomena of Wooden Pillars in the Main Hall of the Fengguo Monastery, Yixian, Liaoning, China - Scientific Investigation with XRD, IC, and FTIR Analysis -

  • Zhou, Yishan;Matsui, Toshiya;Liu, Cheng;Wang, Fei
    • 보존과학회지
    • /
    • 제36권1호
    • /
    • pp.15-27
    • /
    • 2020
  • The Main Hall of the Fengguo monastery in Yixian county, Liaoning province, China, is the best preserved and largest wooden Buddhist structure, typical of the Liao dynasty style, in China. However, some degradation to the timber frame of the Main Hall has been noted, and this is causing concern in terms of the long-term preservation of the structure. In this study, wooden pillars showing the degradation phenomena of whitening, for areas in contact with the stone floor, and extensive surface damage at higher locations(mostly above 1 m) have been examined. Samples taken from wooden pillar surfaces were analyzed using X-ray powder diffraction, Fourier-transform infrared spectroscopy(FTIR), ion chromatography, and pH measurements. With respect to the whitening phenomenon, we found inorganic calcium precipitates and oxalate ions, along with higher pH values. These symptoms indicated that chemical changes were taking place in response to alkaline conditions, suggesting that alkaline mixtures with calcium content in the foundations may be responsible. Regarding the upper surface-damaged areas, no valid evidence for chemical degradation was found using FTIR analysis, while damaged areas exhibited the presence of more bat guano-related materials than which were apparent in undamaged areas. The occurrence of this surface-damaged phenomenon has therefore been attributed to physical damage caused by bat activity over long periods of time.

Continuous Flow Analyzer(CFA)를 이용한 담배 주류연 중 Hydrogen Cyanide(HCN)의 최적 분석방법 구명 (Characteristics of Optimized Analytical Method of Hydrogen Cyanide in Cigarette Mainstream Smoke by Using Continuous Flow Analyzer(CFA))

  • 나승주;어성재;김도연;복진영;황건중
    • 한국연초학회지
    • /
    • 제31권1호
    • /
    • pp.39-44
    • /
    • 2009
  • Hydrogen cyanide (HCN) is present in both the particulate and vapor phase of cigarette mainstream smoke. It is one of the 44 harmful substances on Hoffmann's list and is known to be a major ciliatoxic agent in cigarette mainstream smoke. Typically the determination of HCN in cigarette mainstream smoke has been done through colorimetric and electrochemical techniques, such as UV-spectrophotometry (UV), continuous flow analyzer (CFA), ion chromatography (IC) and capillary GC-ECD. In particular, CFA commonly has been using analysis hydrogen cyanide in cigarette smoke and the basic principle is pyridine-pyrazolone reaction. In this study, the more optimized analytical method is suggested isonicotinic acid-pyrazolone reaction method than previous pyridine-pyrazolone reaction method, a commonly used method for the determination of cyanide in water and air, by CFA. Sample collection was optimized by trapping particulate and vapor phase of smoke separately. The optimum NaOH concentration of the trapping solution was shown to be 0.2 M. HCN was stable up to 6 hours in this concentration but only 3 hours in 0.1 M solution. The sensitivity of this method was fairly good and it might be used in analysis of HCN in cigarette mainstream smoke.

Optimization of Analytical Procedure for Hydrogen Cyanide in Mainstream Smoke

  • Lee, John-Tae;Kim, Hyo-Keun;Hwang, Keon-Joong;Jang, Gi-Chul;Lee, Jeong-Min;Kim, Ick-Joong
    • 한국연초학회지
    • /
    • 제29권2호
    • /
    • pp.125-131
    • /
    • 2007
  • Hydrogen cyanide(HCN), formed from pyrolysis of various nitrogenous compounds such as protein, amino acids and nitrate in tobacco, is present in both the particulate phase and vapor phase of cigarette smoke. Typically the determination of HCN in cigarette smoke has been done through colorimetric and electrochemical techniques, such as fluorescence spectrometry, UV-spectrophotometry (UV), continuous flow analyzer (CFA), capillary GC-ECD and ion chromatography (IC). Most of these techniques are known to be time-consuming and some of them lack specificity or sensitivity. The available results from both our laboratory and reported literatures for 2R4F Kentucky reference cigarette, smoked under ISO condition, show a relatively wide variation ranging from 100 to 120 ug/cig of HCN. Especially, the precision and accuracy of the analytical results of HCN tend to get worse in low tar cigarettes and under intense smoking condition. In this paper, a more optimized analytical methods than previous ones are suggested. This method shows lower detection limit and has improved precision and accuracy, so it is applicable for wide tar level cigarettes under intense smoking condition as well as under ISO smoking condition. Important features of this method are improved sample collection and quantification systems such as the number of trapping units, volume, temperature and type of trapping solution. To avoid volatilization loss of HCN in analyzing mainstream smoke, it is highly recommended that pH values of trapping solutions should be maintained over 11 and cold traps should be used in collecting mainstream smoke.

축산물 중 천연유래 질산염 및 아질산염 함유량 조사 (The Naturally Occurring Levels of Nitrate and Nitrite in Livestock Products)

  • 최재천;박소라;임호수;고경육;김미혜
    • 한국식품위생안전성학회지
    • /
    • 제30권3호
    • /
    • pp.265-271
    • /
    • 2015
  • 본 연구에서는 축산물 및 축산가공품에서 천연적으로 유래되는 질산염과 아질산염의 함유량을 조사하였다. 식육 223건, 식육가공품 51건, 원유 30건, 유가공품 142건, 알류 5건 및 알가공품 7건으로 총 458건에 대해 이온크로마토그래피(IC)를 이용하여 질산염과 아질산염을 분석하였다. 이 때, 축산물 가공기준 및 성분규격의 전처리법과 기기조건을 이용하여 분석하였으며 축산물 및 축산가공품에 적용하여 시험법 검증(직선성, 검출한계, 정량한계, 회수율, 재현성 및 측정불확도)을 실시한 결과, 모두 양호한 값으로 나타났다. 총 458건을 분석한 결과, 질산염이 167건에서 아질산염이 40건에서 검출되어 질산염이 아질산염에 비해 검출된 건수가 많았다. 질산염의 경우, 조제분유류에서 ND~40.23 mg/kg으로, 양념육류에서 ND~37.97 mg/kg으로, 가공치즈류에서 ND~32.40 mg/kg으로, 알가공품에서 4.92~31.50 mg/kg으로, 분유류에서 ND~27.73 mg/kg으로, 소시지류에서 ND~22.45 mg/kg으로, 베이컨류에서 ND~22.45 mg/kg으로, 자연치즈류에서 ND~21.55 mg/kg으로, 햄류와 발효유류에서 ND~20.82 mg/kg으로, 알류에서 ND~13.57 mg/kg으로, 버터류에서 ND~12.77 mg/kg으로, 우유류에서 ND~9.31 mg/kg으로, 식육류에서 ND~3.88 mg/kg의 순으로 나타났다. 한편, 아질산염은 알가공품에서 1.84~17.35 mg/kg으로 나타났으며 식육류에서는 ND~1.92 mg/kg의 범위로 검출되었다.

자외선/가시선 분광법을 이용한 토양 중 6가 크롬 분석방법의 방해요인 분석 및 이온크로마토그래피 적용에 관한 연구 (A Study of Interference Factor of Analysis Method of Hexavalent Chromium in Soil using UV/VIS Spectrometry and Application of Ion Chromatography)

  • 노회정;이명규;이현석;김미라;김동호;김태승
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제17권6호
    • /
    • pp.33-42
    • /
    • 2012
  • This study was performed to find the problems according to interference factors (organic matter, pH, Cr, Mn, Fe, clay, and etc.) when we analyzed the hexavalent chromium [Cr(VI)] in soils using UV/VIS spectrometer (US EPA 7196A), attempted to evaluate the domestic applicability of analytical method (US EPA 7199) using IC-UV/VIS spectrometer as alternative method. The recovery rate of certified reference materials was 75.0% (US EPA 7196A) and 101.4% (US EPA 7199) by the analytical methods. As the results of performing QA/QC about US EPA 7199, method detection limit (MDL) and limit of quantification (LOQ) were 0.062 mg/kg, 0.196 mg/kg, respectively. The LOQ of US EPA 7199 was lower than that of the current soil official testing method in Korea (0.5 mg/kg). Cr(VI) contents in 23 soil samples were compared by the analytical methods of EPA 7196A and 7199. Cr(VI) was detected in 13 of 23 soil samples by EPA 7196A, while EPA 7199 was not detected in any soil samples. The Cr(VI) content in 23 soil samples by EPA 7196A was not clearly correlated with Cr, Fe, Mn and clay content in the soil samples. However, the contents of Cr(VI) and organic matter of the soil samples had the highest coefficient of determination ($R^2$) of 0.80. In order to evaluate the correlation between the recovery rates of Cr(VI) and organic matter contents in the soil samples, the recovery rates of 5 soil samples added Cr(VI) standard solution were analyzed by the analytical methods. According to the results, the higher the organic matter contents in soil samples, the lower the recovery rates of Cr(VI) by US EPA 7196, while in case of US EPA 7199, the recovery rates were stable regardless of the organic matter contents.

북한산국립공원 내 초미세먼지 농도 및 화학적 특성 (Characterization of Aerosol Composition, Concentration, and Sources in Bukhansan National Park, Korea)

  • 강석원;강태원;박태현;박규태;이준홍;홍제우;홍진규;이재홍;이태형
    • 한국대기환경학회지
    • /
    • 제34권3호
    • /
    • pp.457-468
    • /
    • 2018
  • To improve understanding of the physico-chemical characteristics of aerosols in the national park and comparing the air pollution between national park and the urban area nearby national park, the aerosol characterization study was conducted in Bukhansan National Park, Seoul, from July through September 2017. Semi-continuous measurements of $PM_{2.5}$ using PILS (Particle Into Liquid System) coupled with IC (Ion Chromatography) and TOC (Total Organic Carbon) analyzer allowed quantification of concentrations of major ionic species($Cl^-$, $SO_4{^{2-}}$, $NO_3{^-}$, $Na^+$, $NH_4{^+}$, $K^+$, $Mg{^{2+}}$ and $Ca{^{2+}}$) and water soluble organic carbon (WSOC) with 30-minute time resolution. The total mass concentration of $PM_{2.5}$ was measured by T640 (Teledyne) with 5-minute time resolution. The black carbon (BC) and ozone were measured with a minute time resolution. The timeline of aerosol chemical compositions reveals a strong influence from urban area (Seoul) at the site in Bukhansan National Park. Inorganic aerosol composition was observed to be dominated by ammoniated sulfate at most times with ranging from $0.1{\sim}32.6{\mu}g/m^3$ (6.5~76.1% of total mass of $PM_{2.5}$). The concentration of ammonium nitrate, a potential indicator of the presence of local source, ranged from below detection limits to $20{\mu}g/m^3$ and was observed to be highest during times of maximum local urban (Seoul) impact. The total mass of $PM_{2.5}$ in Bukhansan National Park was observed to be 10~23% lower than the total mass of $PM_{2.5}$ in urban area (Gireum-dong and Bulgwang-dong, Seoul). In general, ozone concentration in Bukhansan National Park was observed to be similar or higher than urban sites in Seoul, suggesting additional biogenic VOCs with $NO_x$ from vehicle emission were to be precursors for ozone formation in Bukhansan National Park.

포항분지 제3기 이암의 산성배수 발생 능력 (Acid Rock Drainage Generation Capacity of Tertiary Mudstone in Pohang Basin)

  • 백인우;김재곤;송영석;김태형
    • 한국지반신소재학회논문집
    • /
    • 제19권2호
    • /
    • pp.23-33
    • /
    • 2020
  • 본 연구에서 포항 제3기 이암의 실내시험을 통해 기본적인 특성과 산성배수 발생능력을 파악하였다. XRF 분석 결과 SiO2 성분이 약 60%로 가장 많이 포함되어 있으며, 다음으로 Al2O3와 Fe2O3 순으로 산성배수 발생 개연성이 높은 산화물이 많이 존재함을 알 수 있다. XRD 분석 결과 이암이 황철석(FeS2)을 포함하고 있어 산성배수 발생 개연성이 높은데, 유도결합플라즈마 분광분석기(ICP)로 분석 결과에서도 이암 시료에서 Fe2+ 이온이 높게 측정되었다. 이온 크로마토그래피(IC)로 측정한 음이온 분석 결과 모든 이암 시료 SO2-4 농도가 높게 측정되었다. 원소 분석결과 총 황(S) 함량이 높아 최대 산 발생량(MPA) 계산 결과 1% 이상으로 산성배수 발생 위험이 높게 나타났다. 결론적으로 제3기 이암은 시료에 따라 다소 차이가 있으나 전반적으로 산성배수 발생능력이 높은 것으로 나타났다.

옥외 철제문화재 적용을 위한 탈염처리 방법 연구 (A Study on Desalination Methods for Application of Outdoor Iron Artefacts)

  • 이혜연;조남철;김우현
    • 보존과학회지
    • /
    • 제25권1호
    • /
    • pp.49-60
    • /
    • 2009
  • 옥외 철제문화재는 외부에 노출되어 있으므로 환경오염인자나 산성비에 의한 염($Cl^-$)의 영향으로 부식이 발생되기 때문에 탈염처리 등 보존처리가 필요하다. 그러나 현재 옥외 철제문화재의 보존처리는 강화처리에 한정되어 있어 염에 대한 손상정도나 염을 제거하는 탈염처리 방법에 대한 연구는 거의 없는 실정이다. 기존에 사용하고 있는 탈염방법은 주로 매장 철제문화재를 대상으로 하여 탈염용액에 침적시키는 방법이기 때문에 옥외 철제문화재에 적용하기에는 어려움이 있다. 이러한 점을 감안하여 탈염용액을 재료에 흡수시켜 철제문화재에 흡착시키고 증발을 막기 위해 방수 필름으로 포장하는 탈염 방법을 실험해 보았다. 옥외 철제문화재에 적용 가능한 탈염처리 방법을 알아보기 위하여 우선 매장 철제문화재를 대상으로 실험하였으며, 탈염흡수재료로는 전통한지, 거즈, cotton wipers, 흡습지를 선정하였고, 탈염용액은 NaOH 0.1M를 사용하였다. 또한 기존의 침적탈염방법을 함께 실행하여 흡착탈염방법과의 효율성을 비교해 보았다. 본 탈염실험에 대한 안정성 평가를 위하여 실체현미경과 SEM-EDS, XRD, pH측정과 이온크로마토그래피분석(IC)을 실시하였다. 실험 결과 흡습지가 기존 탈염 방법과 유사한 탈염 효과를 얻을 수 있음을 확인 할 수 있었다.

  • PDF

조선시대 철비(鐵碑)의 보존처리와 탈염방법 비교 연구 (A Study of Conservation and Desalination Methods for an Iron Stele of the Joseon Dynasty)

  • 이혜연;조남철
    • 보존과학회지
    • /
    • 제25권4호
    • /
    • pp.399-409
    • /
    • 2009
  • 외부 환경에 노출된 철제문화재는 환경오염요인에 직접적으로 영향을 받아 부식에 취약하다. 특히 철제유물에 있어서 활성부식을 일으키는 염화이온($Cl^-$)은 반드시 제거되어야 하지만 옥외 철제문화재는 유물의 특성상 탈염의 대상에서 제외되고 있다. 그러므로 본 연구에서는 조선시대 철비를 대상으로 보존처리 및 탈염실험을 실시하였으며, 탈염은 흡습지를 이용한 탈염방법과 기존의 침적탈염방법을 함께 실시하여 그 효율성을 비교하였다. 탈염의 평가는 실체 금속 현미경, SEM-EDS, pH측정과 이온크로마토그래피(IC), XRD분석을 통하여 알아보았다. 실체 금속현미경으로 조사된 결과 부식은 층을 이루고 있으며 금속조직은 백주철로 확인된다. 또한 탈염 전 부식물에 대한 SEM-EDS분석결과 Fe와 O가 주로 검출되었으며 특히 Cl이 2.48wt%까지 측정되었다. 탈염용액에 대한 pH와 음이온을 분석한 결과에서는 흡습지를 이용한 탈염방법도 침적탈염방법과 유사한 탈염효과를 볼 수 있었다. 마지막으로 탈염 전 후 부식물에 대한 XRD분석 결과 탈염전에는 goethite, magnetite, lepidocrocite와 akaganeite가 검출되었으나 탈염 후에는 akaganeite가 검출되지 않아 흡습지를 이용한 탈염의 효과를 확인할 수 있었다. 그러므로 본 연구를 통하여 흡습지를 이용한 탈염방법에서도 기존의 침적탈염방법과 유사한 탈염효과를 확인할 수 있었다.

  • PDF

재난을 대비한 새만금지역의 강우특성에 관한 연구 (The Study on Characteristics of Rainwater in Saemangeum)

  • 임익현;황의진;류지협
    • 한국재난관리표준학회지
    • /
    • 제4권2호
    • /
    • pp.65-72
    • /
    • 2011
  • 본 연구는 새만금지역에서 재난관리 및 우수이용을 목적으로 강우를 채취하여 pH 측정과 이온성분을 분석하고 강우의 특성 파악과 용수부족에 따른 수자원 대체 가능성 등을 파악하기 위한 기초 자료를 제공하고자 한다. 새만금지역의 강우시료 채취를 위해 안정적 시료 채취와 장비관리의 효율성, 접근성이 높은 지점을 선정하여 1개소의 측정소(수동형 우수채취기(R-100형) 2기 설치)를 운영하였다. 시료채취의 기간은 강수량이 풍부한 2009년 3월부터 2009년 9월까지로 7차에 걸쳐 월별로 1회 이상의 시료를 채취하였다. 강우시료의 음이온 분석결과, 음이온은 $SO{_4}^{2-}$>$NO_3{^-}$>$Cl^-$ 순으로 강우의 pH에 높은 영향을 미치는 것으로 나타났다. 양이온은 $Ca^{2+}$>$K^+$>$NH_4{^+}$>$Na^+$>$Mg^{2+}$ 순으로 영향을 미치는 것으로 나타났으며, $Mg^{2+}$이온은 영향이 거의 없는 것으로 분석되었다. 강우중 이온성분의 농도는 초기강우에서 높게 나타났고, 강수량이 증가함에 따라 대기중 이온성분이 감소되어 중기 이후 강우는 농도가 감소되는 것으로 나타났다. 강우의 월별 pH는 5월이 가장 낮고 다음은 3월로 나타났으며, 황사가 발생한 4월과 강우량과 강우빈도가 높은 6월, 7월 8월과 건조한 9월의 pH는 모두 유사한 분포특성을 나타내었다. 새만금지역의 강우는 외부에서 유입되는 대기오염물질의 영향으로 pH 5.6이하로 약산성을 나타내는 것으로 분석되었다.

  • PDF