• Title/Summary/Keyword: Ion Loss

Search Result 386, Processing Time 0.025 seconds

Constant inversion black box model of EDFAs including various loss mechanisms (Loss mechanism을 고려한 밀도 반전이 고정된 EDFA의 black box 모델링에 대한 연구)

  • 민범기;이원재;박재형;박남규
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.3
    • /
    • pp.205-211
    • /
    • 2001
  • We propose a constant inversion black box model of erbium-doped fiber amplifiers (EDFAs) for exact performance predictions for EDFAs operated in the gain-flattened condition. The validity of the newly proposed model was experimentally verified by predicting the performance of EDFAs for the L band, within 1.9% required pump power discrepancy. The role of ion pairing effects on the power conversion efficiency is also discussed. ussed.

  • PDF

Analysis on capacity loss caused by air oxidation of $V^{2+}$ ion using UV-Visible spectrophotometer for vanadium redox flow battery (공기 중 바나듐 2가 이온 산화에 의한 바나듐 레독스 흐름전지의 내구성 영향 분석)

  • Kwon, Soonkwan;Kim, Hansung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.175.2-175.2
    • /
    • 2011
  • 바나듐 3, 4, 5가 이온은 공기 중에서 안정하지만, 바나듐 2가 이온은 쉽게 산화된다. 그러므로 바나듐 2가 이온이 담겨져 있는 음극 탱크가 공기와 접촉하지 않게 하는 것이 중요하다. 충전 중 음극 탱크에 공기가 침투되면, 바나듐 2가 이온은 3가 이온으로 산화되기 때문에 음극과 양극의 전해질에 불균형을 초래한다. 이러한 불균형은 바나듐 레독스 흐름전지 용량저하의 원인이 된다. 본 연구에서는 공기 중 2가 이온 산화에 의한 전해질의 불균형 현상을 쉽게 보여주기 위해, 공기노출과 차단조건에서 충방전 중에 발생한 음극과 양극의 바나듐 이온 상태변화량을 UV-Visible spectrophotometer를 이용해 정량적으로 분석하였다. 분석 결과, 공기노출 조건에서 음극의 충전 시, 충방전 cycle이 진행 될수록 바나듐 2가 이온의 양이 현격히 줄어들었지만, 공기차단 조건에서는 2가 이온의 양이 공기노출 조건보다 훨씬 더 적게 줄어들었다. 즉, 공기차단 조건에서는 바나듐 2가 이온이 3가로 산화되지 않아서 음극의 충전 후 바나듐 3가에서 2가로 전환되는 양이 공기노출 조건보다 더 많은 것을 확인할 수 있었다. 이러한 영향으로 인해, 충방전 10th cycle을 진행해 본 결과, 공기차단 조건에서는 충방전 용량감소가 거의 없었지만 공기노출 조건에서는 현격한 충방전 용량 감소를 보였다.

  • PDF

Determinant Involved in the Loss of Pathogenicity in Wilt - Inducing Pseudomonas solanacerum (마름병 병원균 Pseudomonas solanacearum의 병원성 상실요인에 관하여)

  • 김을제;윤경란;이영하;이청호;박지창;최광태
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.12 no.1
    • /
    • pp.9-18
    • /
    • 1990
  • To study the determinants which are involved in the loss of pathogenicity in wilt-inducing Pseudomoms solamcewum, several physlologica I functions were compared in a virulent P. solanacearum strain and an avirulent, spontaneously derived mutant strain. The polyacrylamide gel electrophoresis showed the distinction between two strains in the patterns and the relative intensity of proteins produced intracellularly or extracellularly. Enzyme assays showed that the level of polygalacturonase activity in the culture filtrate of the avirulent mutant was markedly reduced, while carboxymethylcellulase(rondoglucanase) activity in both strains were nearly negligible. These results suggest that the loss of pathogenicity in mutant strain is attributed in part to the reduced production of polygalacturonase. In audit ion, comparative analyses by agarose gel electrophoresis of DNA molecules isolated from both strains show that the pathogenicity genes of p. solanaceerum are not located on plasmid but are on chromosome.

  • PDF

Activation energy for the loss of substitutional carbon in $Si_{0.984}C_{0.016}$ grown by solid phase epitaxy

  • Kim, Yong-Jeong;Kim, Tae-Joon;Park, Byungwoo;Song, Jong-Han
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.4 no.2
    • /
    • pp.50-54
    • /
    • 2000
  • We studied the synthesis of S $i_{1-x}$ Cx (x=0.016) epitaxial layer using ion implantation and solid phase epitaxy (SPE). The activation energy Ea was obtained for the loss of substitutional carbon using fourier transform-infrared spectroscopy (FTIR) and high-resolution x-ray diffraction (HR-XRD). In FTIR analysis, the integrated peak intensity was used to quantify the loss of carbon atoms from substitutional to interstitial sites during annealing. The substitutional carbon contents in S $i_{0.984}$ $C_{0.016}$ were also measured using HR-XRD. By dynamic simulations of x-ray rocking curves, the fraction of substitutional carbon was obtained. The effects of annealing temperature and time were also studied by comparing vacuum furnace annealing with rapid thermal annealing (RTA))))))

  • PDF

Thermal Behavior of LixCoO2 Cathode and Disruption of Solid Electrolyte Interphase Film

  • Doh, Chil-Hoon;Kim, Dong-Hun;Lee, Jung-Hun;Lee, Duck-Jun;Jin, Bong-Soo;Kim, Hyun-Soo;Moon, Seong-In;Hwang, Young-Gi;Veluchamy, Angathevar
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.783-786
    • /
    • 2009
  • Thermogravimetric analysis (TGA), differential scanning calorimetry (DSC) and ion chromatography(IC) were employed to analyze the thermal behavior of $Li_xCoO_2$ cathode material of lithium ion battery. The mass loss peaks appearing between 60 and 125 ${^{\circ}C}$ in TGA and the exothermic peaks with 4.9 and 7.0 J/g in DSC around 75 and 85 ${^{\circ}C}$ for the $Li_xCoO_2$ cathodes of 4.20 and 4.35 V cells are explained based on disruption of solid electrolyte interphase (SEI) film. Low temperature induced HF formation through weak interaction between organic electrolyte and LiF is supposed to cause carbonate film disruption reaction, $Li_2CO_3\;+\;2HF{\rightarrow}\;2LiF\;+\;CO_2\;+\;H_2O$. The different spectral DSC/TGA pattern for the cathode of 4.5 V cell has also been explained. Presence of ionic carbonate in the cathode has been identified by ion chromatography and LiF reported by early researchers has been used for explaining the film SEI disruption process. The absence of mass loss peak for the cathode washed with dimethyl carbonate (DMC) implies ionic nature of the film. The thermal behavior above 150 ${^{\circ}C}$ has also been analyzed and presented.

Theoretical Calculation on Alpha Track Density by Using an Electrostatic Ion Spectrometer (정전기분광분석방법에 의한 알파입자비적밀도의 이론적 계산연구)

  • Yoon, Suk-Chul;Ha, Chung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.25-35
    • /
    • 1993
  • To develop a technique of theoretical alpha track density calculation for comparison with measured track density, an electrostatic ion spectrometer was specially designed and fabricated. The mobility spectrum of first radon daughter(Po-218) in the range of $0.07{\sim}5.0cm^2/V\;s$ from the radon chamber was measured using-the electrostatic ion spectrometer. Measurement was taken in a radon chamber operated using dry particle free air passed through silica gel, activated charcoal and molecular sieve filters. The mobility of a new-born Po-218 ion measured by the electrostatic ion spectrometer was determined to be $1.92cm^2/V\;s$. A comparison of the theoretical and measured alpha track densities was completed and uncertainties concerning the shape of the spectrum were analyzed. It was found that the discrepancies in track densities are primarily Que to the neglect of wall loss of ions in the theoretical track density calculation.

  • PDF

Lithium Recovery from NCM Lithium Ion Battery by Hydrogen Reduction Followed by Water Leaching (NCM계 리튬이온 배터리 양극재의 수소환원과 수침출에 의한 리튬 회수)

  • So-Yeong Lee;So-Yeon Lee;Dae-Hyeon Lee;Ho-Sang Sohn
    • Resources Recycling
    • /
    • v.33 no.1
    • /
    • pp.15-21
    • /
    • 2024
  • The demand for electric vehicles powered by lithium-ion batteries is continuously increasing. Recovery of valuable metals from waste lithium-ion batteries will be necessary in the future. This research investigated the effect of reaction temperature on the lithium recovery ratio from hydrogen reduction followed by water leaching from lithium-ion battery NCM-based cathode materials. As the reaction temperature increased, the weight loss ratio observed after initiation increased rapidly owing to hydrogen reduction of NiO and CoO; at the same time, the H2O amount generated increased. Above 602 ℃, the anode materials Ni and Co were reduced and existed in the metallic phases. As the hydrogen reduction temperature was increased, the Li recovery ratio also increased; at 704 ℃ and above, the Li recovery ratio reached a maximum of approximately 92%. Therefore, it is expected that Li can be selectively recovered by hydrogen reduction as a waste lithium-ion battery pretreatment, and the residue can be reprocessed to efficiently separate and recover valuable metals.

텍스쳐 형성 방식에 따른 실리콘 태양전지의 모듈화에 의한 효율 손실에 대한 연구

  • No, Jun-Hyeong;Son, Chan-Hui;Kim, Dong-Hae;Seo, Il-Won;Yun, Myeong-Su;Jo, Tae-Hun;Jo, Lee-Hyeon;Gwon, Gi-Cheong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.438-438
    • /
    • 2012
  • 결정질 실리콘 태양전지 공정 중 텍스쳐 공정은 표면에서 반사되는 반사광을 줄여 단락전류(Isc)를 증가시킨다. 표면 텍스쳐 형성 방식으로는 일반적으로 습식 식각(Wet etching) 공정과 건식 식각(Reactive ion etching:RIE) 공정이 있다. 습식 식각 공정은 식각 용액을 사용하는 공정이며 건식 식각 공정은 플라즈마를 통하여 식각하는 공정으로 습식 식각 공정의 경우 식각 용액에 의한 공정상 위험도가 높으며, 용액의 폐기물에 의한 환경오염 문제가 크다. 건식 식각공정의 경우 습식 식각과 달리 공정상 위험도가 낮으며 불규칙적인 결정방향에 영향 받지 않는 비등방성 식각이 가능하여 다결정 실리콘 태양전지의 경우 습식 식각 공정보다 반사광이 적어 단락전류가 증가하게 된다. 그리고 태양전지를 Photovoltaic module로 만들게 되면 태양전지의 효율이 떨어지는데 이것을 Cell to module loss (CTM loss)라 부르며 이는 태양전지의 발전량을 줄이는 큰 원인이 된다. CTM loss의 경우 습식 식각 공정보다 건식 식각 공정에서 더 크게 나타나며 건식 식각 공정한 PV module의 경우 CTM loss로 인해 습식 식각 공정을 통한PV module와 비슷한 효율을 내게 된다. 본 연구에서는 식각 공정의 방식에 따라 나타나는CTM loss 중 광 손실 원인을 외부양자효율(External Quantum Efficiency)과 투과율(Transmittance), 반사율(Reflectance) 등 광 특성 통하여 분석한다.

  • PDF

Suppression of the Methyl Radical Loss from Acetone Cation within (CH3COCH3)n{CH3COCH3}+ Clusters

  • Lee, Yong-Hoon;Oh, Myoung-Kyu;Choi, Sung-Chul;Ko, Do-Kyeong;Lee, Jong-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.8
    • /
    • pp.1519-1524
    • /
    • 2008
  • We have investigated the photophysics of the acetone radical cation in the vacuum ultraviolet energy region by multiphoton ionization combined with time-of-flight mass spectrometry in a cluster beam. We have found that the loss of methyl radical from the acetone radical cations is remarkably suppressed at 10.5 eV when they are solvated by a few neutral acetone molecules. The cluster ion mass spectra obtained by nanosecond and picosecond laser pulses reveal that there are intermolecular processes, occurring in several tens of picoseconds, which are responsible for the survival of the acetone cations in clusters. This remarkable solvation effect on the yield of the methyl radical loss from the acetone cation can be rationalized by the intracluster vibrational energy redistribution and the self-catalyzed enolization which compete with the methyl radical loss process.

Performance Modeling of Single-Chamber Micro SOFC (단실형 마이크로 고체 산화물 연료전지의 작동특성 전산모사)

  • Cha, Jeong-Hwa;Chung, Chan-Yeup;Chung, Yong-Chae;Kim, Joosun;Lee, Jongho;Lee, Hae-Weon
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.12 s.283
    • /
    • pp.854-859
    • /
    • 2005
  • Performance of micro scale intermediate temperature solid oxide fuel cell system has been successfully evaluated by computer simulation based on macro modeling. Two systems were studied in this work. The one is designed that the ceria-based electrolyte placed between composite electrodes and the other is designed that electrodes alternately placed on the electrolyte. The injected gas was composed of hydrogen and air. The polarization curve was obtained through a series of calculations for ohmic loss, activation loss and concentration loss. The calculation of each loss was based on the solving of mathematical model of multi physical-phenomena such as ion conduction, fluid dynamics and diffusion and convection by Finite Element Method (FEM). The performance characteristics of SOFC were quantitatively investigated for various structural parameters such as distance between electrodes and thickness of electrolyte.