• Title/Summary/Keyword: Ion Exchange Membrane

Search Result 467, Processing Time 0.026 seconds

Alkali Recovery by Electrodialysis Process: A Review (전기투석 공정에 의한 알칼리 회수: 총설)

  • Sarsenbek Assel;Rajkumar Patel
    • Membrane Journal
    • /
    • v.33 no.3
    • /
    • pp.87-93
    • /
    • 2023
  • Electrodialysis (ED) is essential in separating ions through an ion exchange membrane. The disposal of brine generated from seawater desalination is a primary environmental concern, and its recycling through membrane separation technology is highly efficient. Alkali is produced by several chemical industries such as leather, electroplating, dyeing, and smelting, etc. A high concentration of alkali in the waste needs treatment before releasing into the environment as it is highly corrosive and has a chemical oxygen demand (COD) value. The concentration of calcium and magnesium is almost double in brine and is the perfect candidate for carbon dioxide adsorption, a major environmental pollutant. Sodium hydroxide is essential for the metal carbonation process which, is easily produced by the bipolar membrane electrodialysis process. Various strategies are available for its recovery, like reverse osmosis (RO), nanofiltration (NF), ultrafiltration (UF), and ED. This review discusses the ED process by ion exchange membrane for alkali recovery are discussed.

Synthesis and Characterization of Vinylbenzyl Chloride-co-Styrene-co-Hydroxyethyl Acrylate (VBC-co-St-co-HEA) Anion-Exchange Membrane for All-Vanadium Redox Flow Battery (전바나듐계 레독스-흐름 전지용 Vinylbenzyl Chloride-co-Styrene-co-Hydroxyethyl Acrylate (VBC-co-St-co-HEA) 음이온교환막의 합성 및 특성)

  • Baek, Young-Min;Kwak, Noh-Seok;Hwang, Taek-Sung
    • Polymer(Korea)
    • /
    • v.35 no.6
    • /
    • pp.586-592
    • /
    • 2011
  • In this study, we synthesized vinylbenzyl chloride-co-styrene-co hydroxyethyl acrylate (VBC-co-St-co-HEA) copolymer that can be applied to redox the flow battery process. The anion exchange membrane was prepared by the amination and crosslinking of VBC-co-St-co-HEA copolymer. The chemical structure and thermal properties of VBC-co-St-co-HEA copolymer and aminated VBC-co-St-co-HEA(AVSH) membrane were characterized by FTIR, $^1H$ NMR, TGA, and GPC analysis. The membrane properties such as ion exchange capacity(IEC), electrical resistance, ion conductivity and efficiency of all-vanadium redox flow battery were measured. The IEC value, electrical resistance, and ion conductivity were 1.17 meq/g, $1.9{\Omega}{\cdot}cm^2$, 0.009 S/cm, respectively. The charge-discharge efficiency, voltage efficiency and energy efficiency from all-vanadium redox flow battery test were 99.5, 72.6 and 72.1%, respectively.

Stoichiometry of $Ns^+/Ca^{2+}$ Exchange Quantified with Ion-selective Microelectrodes in Giant Excised Cardiac Membrane Patches

  • kang, Tong Mook;Hilgemann, Donald W.
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 2003.06a
    • /
    • pp.30-30
    • /
    • 2003
  • Without a definitive resolution of stoichiometry of cardiac Na$^{+}$-Ca$^{2+}$exchange (NCX), we cannot proceed to any quantitative analysis of exchange function as well as cardiac excitation-contraction coupling. The stoichiometry of cardiac NCX, however, is presently in doubt because reversal potentials determined by various groups range between those expected for a 3-to-1 and a 4-to-1 flux coupling. For a new perspective on this problem, we have used ion-selective microelectrodes to quantify directly exchanger-mediated fluxes of $Ca^{2+}$and Na$^{+}$in giant membrane patches. $Ca^{2+}$- and Na$^{+}$-selective microelectrodes, fabricated from quartz capillaries, are placed inside of the patch pipettes to detect extracellular ion transients associated with exchange activity. Ion changes are monitored at various distances from the membrane, and the absolute ion fluxes through NCX are determined via simulations of ion diffusion and compared with standard ion fluxes (Ca$^{2+}$ fluxes mediated by $Ca^{2+}$ ionophore, and Na$^{+}$ fluxes through gramicidin channels and Na$^{+}$/K$^{+}$pumps). Both guinea pig myocytes and NCX1-expressing BHK cells were employed, and for both systems the calculated stoichiometries for inward and outward exchange currents range between 3.2- and 3.4-to-1. The coupling ratios do not change significantly when currents are varied by changing cytoplasmic [Ca$^{2+}$] or by adding cytoplasmic Na$^{+}$. The exchanger reversal potentials, measured in both systems under several ionic conditions, range from 3.1- to 3.3-to-1. Taken together, a clear discrepancy from a NCX stoichiometry of 3-to-1 was obtained. Further definitive experiments are required to acquire a fixed number, and the present working hypothesis is that NCX current has an extra current via ‘conduction mode’.ent via ‘conduction mode’.

  • PDF

Synthesis and Characteristics of Partially Fluorinated Poly(vinylidene fluroide)(PVDF) Cation Exchange Membrane via Direct Sulfonation (직접술폰화반응에 의한 부분불소화 Poly(vinylidene fluroide)(PVDF) 양이온교환막의 합성 및 특성)

  • Kang, Ki Won;Hwang, Taek Sung
    • Membrane Journal
    • /
    • v.25 no.5
    • /
    • pp.406-414
    • /
    • 2015
  • In this study, partially fluorinated cation exchange membranes were prepared by direct sulfonation of Poly(VDF-co-hexafluoropropylene) copolymers (PVDF-co-HFP) followed by a casting method for application in the Membrane capacitive deionization (MCDI). The structure of sulfonated PVDF-co-HFP (SPVDF) was confirmed by Fourier-transform infrared (FT-IR) and $^1H$ Nuclear magnetic resonance ($^1H$ NMR) analysis. For quantitative analysis of the chemical composition, the X-ray Photoelectron Spectroscopy (XPS) was used. The membrane properties such as water uptake, ion exchange capacity and electrical resistance were measured. It was suggested that the optimum direct sulfonation condition of PVDF-co-HFP ion exchange membranes was $60^{\circ}C$ and 7 hours for temperature and duration of sulfonation, respectively. The water uptake of the SPVDF ion exchange membrane was 21.5%. The ion exchange capacity and electrical resistance were 0.89 meq/g and $3.70{\Omega}{\cdot}cm^2$, respectively. It was investigated that if it is feasible to apply these membranes in MCDI at various cell potentials (0.9~1.5 V) and initial flow rates (10~40 mL/min). In the MCDI process, the maximum salt removal rate was 62.5% in repeated absorption-desorption cycles.

Preparation of Heterogeneous Bipolar Membranes Using Poly (phenylene oxide, PPO) Polyelectrolyte and Their Water Splitting Properties (Poly (phenylene oxide, PPO) 고분자 전해질을 이용한 불균질 바이폴라막 제조 및 물분해 특성)

  • Kim, In Sik;Hwang, Seong Yeon;Kang, Byung Gwan;Hwang, Taek Sung
    • Korean Chemical Engineering Research
    • /
    • v.57 no.1
    • /
    • pp.65-72
    • /
    • 2019
  • In this study, heterogeneous ion exchange membranes were prepared by casting method with various mixing ratios of PPO ion-selective solution and ion exchange resin. Then heterogeneous bipolar membranes were prepared by using this. The water content of heterogeneous cation and anion exchange membranes were 60~80% respectively, the ion exchange capacity was 2.81~3.26 meq/g, 2.31~2.74 meq/g and electrical resistances were $1.65{\sim}1.45{\Omega}{\cdot}cm^2$ and $1.55{\sim}1.05{\Omega}{\cdot}cm^2$. The tensile strength of heterogeneous bipolar membrane was lower than that of PPO resin before functionalization ($700Kg_f/cm^2$). The tensile strength of heterogeneous bipolar membrane with catalyst layer was lower than that of non-catalytic heterogeneous bipolar membrane. The water splitting voltage of the heterogeneous bipolar membrane with catalyst layer was low and stable at a minimum of 1.7~1.8 V, maximum 3.9~4.0 V, and the water splitting voltage of the non-catalytic heterogeneous bipolar membrane was constant at 3.8~4.0 V.

Preparation and Characterization of ion Exchange Membrane for Direct Methanol Fuel Cell(DMFC) Using Sulfonated Polysulfone (설폰화 폴리설폰을 이용한 직접메탄올연료전지용 이온교환막의 제조 및 특성 연구)

  • 신현수;이충섭;전지현;정선영;임지원;남상용
    • Membrane Journal
    • /
    • v.12 no.4
    • /
    • pp.247-254
    • /
    • 2002
  • In order to develop the ion exchange membranes which would be used in direct methanol fuel cell (DMFC), the polysulfone polymer was sulfonated using chlorosulfonic acid (CSA) and trimethylchlorosilane(TMCS). It has been characterized in terms of ion conductivities, methanol crossover, swelling degree and ion exchange capacities for the heat untreated and treated membranes at $150^{\circ}C.$ Typically, the methanol permeability and ion conductivity at the mole ratio of 1.4 between polysulfone repeating unit and sulfonating agents showed $2.87{\times}10^{-7}\; cm^2/s$(without heat treatment), $1.52{\times}10^{-7}\; cm^2/s$(with heat treatment) and $1.10{\times}10^{-2}\; S/cm$(without heat treatment), $0.87{\times}10^{-2}\;$ S/cm(with heat treatment), respectively. After the mole ration of 1.4 both values indicated mild increase.

Speciation of Cd, Cu and Zn in Sewage Sludge-Treated Soils Incubated under Aerobic and Anaerobic Conditions

  • Lee, Sang-Mo;Cho, Chae-Moo;Yoo, Sun-Ho
    • Journal of Applied Biological Chemistry
    • /
    • v.42 no.2
    • /
    • pp.85-91
    • /
    • 1999
  • The incubation study was conducted under aerobic and anaerobic conditions to study the release of the kinetically labile forms (i. e. chelating ion or anion forms) of Cd, Cu and Zn in sludge-untreated soil ("Control"), sludge 50 and $100dry\;Mg\;ha^{-1}$ treated soils ("Soil-Sludge mixtures"), and sewage sludge ("Sludge"). The chelating ion and anion exchange membranes were embedded into the samples and incubated for 16 weeks under aerobic and anaerobic condition. The total amounts of chelating ion or anionic forms of Cd were too little to be measured during both aerobic and anaerobic incubation. On the other hand, the total amounts of chelating ion or anionic forms of Cu and Zn slightly increased throughout the incubation period under both incubation conditions. For "Control" and "Soil-Sludge mixtures" treatments, the total amounts of Cu and Zn in chelating ion and anion exchange membrane were little difference between aerobic and anaerobic condition, and the total amounts of chelating ion form of Cu and Zn were not different from the those of anionic form of Cu and Zn. However, for "Sludge" treatment, the total amounts of Cu and Zn in anion and chelating ion exchange membrane were greater under aerobic condition than under anaerobic condition, and the total amounts of chelating ion form of Cu and Zn were greater than those of anion form of Cu and Zn under both incubation conditions.

  • PDF

Preparation of PVA/PAM/Zirconium phosphate Membrane for Proton Exchange Membranes (양이온교환용 PVA/PAM/Zirconium phosphate 막의 제조)

  • 임지원;황호상;김영진;남상용
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.117-125
    • /
    • 2004
  • Proton exchange membrane composed of PVA/PAM/ZrP was prepared and effect of PAM and ZrP contents on properties and performance of the membrane were investigated. PAM as a crosslinking agent was mixed into PVA solution with different concentration (7∼11 wt%) and the PVA/PAM solution was cast to prepare PVA/PAM crosslinked membrane. The membrane was treated in the solution of zirconyl chloride and phophoric acid to make a PVA/PAM/ZrP composite membrane. Methanol permeability, ion conductivity, swelling and ion exchange capacity of the membranes with different ZrP concentration were $10^{-8}∼l0^{-6}$ $\textrm{cm}^2$/sec, $10^{-3}~10^{-2}$ S/cm, 0.26∼1.17 g $H_2O$/g membrane and 2.59∼5.1 meq/g membrane, respectively. Hethanol permeability and ion conductivity of the PVA/PAM/ZrP membrane were improved by 18% and 23%, respectively, compared to those of the PVA/PAM membrane.