• Title/Summary/Keyword: Ion Column

Search Result 620, Processing Time 0.027 seconds

괄루근으로부터 분리한 다당류의 화학 및 활성

  • 이정규
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1993.04a
    • /
    • pp.45-45
    • /
    • 1993
  • 괄루근으로부터 분리된 다당류에 대하여 continuous gel electrophoresis, SDS-Polyacrylamide gel eletrophoresis, ion exchange column chromatography, Hydroxyapatite column chromatography 및 Gel filtration등의 방법을 이용하여 다음과 같은 결과를 얻었다. 1) 황산암모늄 분별침전법에 의한 렉틴의 정제도는 초추출물의 4.85배이며 DEAE Sephadex A-50 column chromatography법에 의한 정제도는 24.17배로 나타났고, 마지막 정제단계인 Sephacryl S-200 gel filtration에 의한 정제도는 47.34배로 나타났다. 2) 정제된 렉틴의 분자량은 60,000da1ton으로 나타났다. 3) 사람의 혈액형에 따른 응집효과는 90-100%로 특이성은 없었다.

  • PDF

Purification and Characterization of the Recombinant Arabidopsis thaliana Acetolactate Synthase

  • 조규봉;홍성택;최명운;장수익;최정도;고은희
    • Bulletin of the Korean Chemical Society
    • /
    • v.18 no.6
    • /
    • pp.648-653
    • /
    • 1997
  • Acetolactate synthase was purified from Escherichia coli MF2000/pTATX containing Arabidopsis thaliana acetolactate synthase gene. Purification steps included DEAE cellulose ion exchange column chromatography, phenyl sepharose hydrophobic column chromatography, hydroxylapatite affinity column chromatography, and Mono-Q HPLC. Molecular weight was estimated to be ∼65 KDa and purification fold was 109 times. The enzyme showed a pH optimum of 7 and the $K_M$ value was 5.9 mM. The purified enzyme was not inhibited by any of the end products, valine, leucine, and isoleucine.

Determination of Co(II) Ion as a 4-(2-Thiazolylazo)resorcinol or 5-Methyl-4-(2-thiazolylazo)resorcinol Chelate by Reversed-Phase Capillary High-Performance Liquid Chromatography

  • Chung, Yong-Soon;Chung, Won-Seog
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1781-1784
    • /
    • 2003
  • Determination of Co(II) ion as a 4-(2-thiazolylazo)resorcinol(TAR) or 5-methyl-4-(2-thiazolylazo)resorcinol(5MTAR) chelate was accomplished by reversed-phase capillary high-performance liquid chromatography (RP-Capillary-HPLC) using a Vydac $C_4$ column and MeCN-water mixture as mobile phase. The effect of change in pH and MeCN percentage of the mobile phase on the retention factor, k and peak intensity were evaluated. It was found that 30% MeCN (v/v) of pH 5.60 or 7.20 was adequate as mobile phase when TAR or 5MTAR is used. Detection limit (D.L., S/N=3) in each case was $2.0\;{\times}\;10^{-7}$M (11.8 ppb) and $3.0\;{\times}\;10^{-7}$ M (17.7 ppb). The Co(II) ion in mineral and waste water was determined with the optimum column and mobile phase.

Adsorption of copper ions from aqueous solution using surface modified pine bark media (표면개질된 소나무 수피를 이용한 수용액의 구리이온 흡착)

  • Park, Se-Keun;Kim, Yeong-Kwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.131-140
    • /
    • 2019
  • This study used a packed column reactor and a horizontal flow mesh reactor to examine the removal of copper ions from aqueous solutions using pine bark, a natural adsorbent prepared from Korean red pine (Pinus densiflora). Both equilibrium and nonequilibrium adsorption experiments were conducted on copper ion concentrations of 10mg/L, and the removals of copper ions at equilibrium were close to 95%. Adsorption of copper ions could be well described by both the Langmuir and Freundlich adsorption isotherms. The bark was treated with nitric acid to enhance efficiency of copper removal, and sorption capacity was improved by about 48% at equilibrium; mechanisms such as ion exchange and chelation may have been involved in the sorption process. A pseudo second-order kinetic model described the kinetic behavior of the copper ion adsorption onto the bark. Regeneration with nitric acid resulted in extended use of spent bark in the packed column. The horizontal flow mesh reactor allowed approximately 80% removal efficiency, demonstrating its operational flexibility and the potential for its practical use as a bark filter reactor.

Effect of Packing Density of ion-Exchange on the Nickel Adsorption Column in Electroplating Rinse Water (이온교환 칼럼 충진비의 변화가 도금폐수 중 니켈이온 흡착에 미치는 영향)

  • 황택성;이진혁
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.551-558
    • /
    • 2002
  • It was observed that adsorption characteristics of sulfonated fabric ion-exchanger for separating nickel ion from electroplating rinse water. Swelling ratio was increased by increasing degree of sulfonation and polarity of solvent. Ion-exchange capacity was also increased by increasing degree of sulfonation and showed 3.38 meq/g at 16% sulfonated ion-exchanger. There was little effects of pH. Adsorption equilibrium was attained within 10 min, and adsorption rate was 7.5 mg/min. Adsorption capacity was not changed after 7 cycles of regeneration process. Regeneration adsorption capacity was slightly decreased to 2.01 meq/g. It confirmed that durability of sulfonated fabric ion-exchanger was suitable for adsorption process. Adsorption equilibrium time was linearly increased by increasing L/D and adsorption capacity showed the ion exchange capacity within the range of 2.71 ∼ 3.01 meq/g in continuous process. Design of adsorption column could be possible for L/D<2. Under constant L/D condition, there is no little pH effect when rinse water is acidic solution, and operation condition of adsorption process was optimized under pH 5.

Determination of Trace Metals in Atmospheric Particulates by Ion Chromatography

  • Lee Yong-Keun;Kim Hak-Chul;Lee Dong Soo
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.12
    • /
    • pp.1045-1049
    • /
    • 1994
  • A simple and fast ion chromatographic method is developed for the determination of transition metals such as Fe, Cu, Ni, Zn and Co in atmospheric particulates. The method involves acid digestion, on-column preconcentration, and subsequent ion chromatogaphic detection. The precision of the method is less than 3${\%}$ RSD at parts per billion level for the metals studied. No significant interferences are observed. The results obtained with this method agree well with those by ICP-AES.

Comparing the Performance of One-column Process and Four-zone Simulated Moving Bed by Computer Simulation

  • Kim Young Sik;Lee Chong Ho;Wankat Phillip C.;Koon Yoon Mo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.5
    • /
    • pp.362-368
    • /
    • 2004
  • A new one-column chromatography process, analogous to a four-zone simulated moving bed (SMB), was presented. The basic principle of the process was identical to that of a four-zone SMB. The process consisted of one chromatographic column and four tanks, instead of the four columns in the four-zone SMB (1-1-1-1), and has been used for the separation of two amino acids, phenylalanine and tryptophan, using an ion exchange resin. The operating parameters for the one-column process and four-zone SMB were obtained from equilibrium theory. Computer simulations were used to compare the performances of the new one column process to that of the general four-zone SMB, using Aspen $Chromatography^{TM}$ v 11.1. The differences between the one-column and SMB processes in terms of the purities and yields of phenylalanine and tryptophan were less than 4 and about $6\%$, respectively. The lower purities of the one-column process were due to the loss of the developed concentration profiles in the column when the liquid was stored in tanks. The one-column process gave great flexibility, and would be useful for reconstructing an existing conventional chromatography process to one of a SMB.

Analysis of Molecular Species of Vegetable Oil Triglycerides by Capillary Column GC-MS (Capillary Column GC-MS에 의한 식물유 트리글리세리드 분자종의 분석)

  • Yoon, Hyeung-Sik;Kim, Seon-Bong;Park, Yeung-Ho
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.391-398
    • /
    • 1989
  • Triglyceride molecular species In some vegetable oils were analyzed by capillary column gas chromatography and electron impact ionization mass spectrometry utilizing selected ion monitoring. Triglycerides were separated according to their molecular weights and their degrees of unsaturation on $25m{\times}0.25mm$ fused silica open tubular capillary column coated with a phenylmethylsilicone gum stationary phase and in an analysis time less than 13 min. Triglyceride molecular species were identified by analyzing the fragment ions having the same time on the selected ion monitoring profile . The major triglyceride molecular species in each oils were $C_{18:1}.\;C_{18:2}.\;C_{18:2}(OLL:18.3%),\;C_{18:2}.\;C_{18:2}.\;C_{18:2}(LLL;\;14.3%),\;C_{18:0}.\;C_{18:2}.\;C_{18:2}(SLL;\;14.1%),\;C_{16:0}.\;C_{18:2}.\;C_{18:2}(PLL;\;13.2%),\;C_{16:0}.\;C_{18:2}.\;C_{18:1}(PLO;\;11.6%)$ in corn oil, $C_{18:2}.\;C_{18:2}.\;C_{18:2}(LLL;\;18.0%),\;C_{18:1}.\;C_{18:2}.\;C_{18:2}(OLL;\;18.0%),\;C_{16:0}.\;C_{18:2}.\;C_{18:2}(PLL;\;17.1%)$ in safflower oil, $C_{16:0}.\;C_{18:2}.\;C_{18:2}(PLL;\;23.5%),\;C_{16:0}.\;C_{18:2}.\;C_{18:1}(PLO;\;13.8%),\;C_{18:0}.\;C_{18:1}.\;C_{18:1}(SOO;\;13.5%),\;C_{18:1}.\;C_{18:2}.\;C_{18:2}(OLL;\;10.6%)$ in cottonseed oil.

  • PDF

Design and Manufacturing of Focused Ion Beam Machining System (집속이온빔을 가공 시스템 설계 및 제작)

  • Park C.W.;Lee J.H.;Choi J.H.;Yu S.M.
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.30-34
    • /
    • 2005
  • This paper describes the design and manufacturing of a focused-ion-beam machining system which can make small features of nano size. We use a SIMION simulator in order to obtain the design data of an ion column. The simulation result shows that the focal length of ion beam decreases as the applied voltage of object lens increases. Finally, we obtained the good images of a mesh of 50 micrometers by using the adjustment of applied voltage, acceleration power, and dimension of each elements.

  • PDF

STRENGTH CHANGES OF SURROUNDING CLAY DUE TO SOIL-CEMENT COLUMN INSTALLATION

  • Miura, Norihiko
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1997.10a
    • /
    • pp.19-36
    • /
    • 1997
  • This paper discusses the reduction and subsequent recovery and increase of shear strength of clay in the vicinity of soil-cement column. Laboratory and field tests were conducted to investigate the effects on surrounding clay during and after soil-cement column installation in soft Ariake clay. Discussions were made on the mechanism of strength changes of clay by considering the thixotropic recovery, reconsolidation effect, penetration of cement slurry and diffusion of exchangeable cations. On the basis of field and laboratory observations, 10 days after column installation, the decreased shear strength of surrounding clay during mixing was recovered and 30 days later, shear strength of surrounding clay increased 30% by average. Therefore, it is recommended that the increase of shear strength of clay can be taken into consideration in the bearing capacity and stability analysis of the composite ground.

  • PDF