• 제목/요약/키워드: Iodine radioisotope

검색결과 21건 처리시간 0.024초

활성알루미나를 이용하여 방사성 폐수 중 I-와 IO3-를 제거하는 방법 (Removal of I- and IO3- from Aqueous Solution)

  • 임헌성;이석근
    • 분석과학
    • /
    • 제22권6호
    • /
    • pp.519-523
    • /
    • 2009
  • 본 연구는 수용액 중에 존재하는 방사성 동위원소인 요오드 즉, 요오드이온($I^-$), 요오드산이온(${IO_3}^-$)및 요오드($I_2$)를 효과적으로 제거하는 방법에 관한 것이다. 별도로 물리적 화학적 변화의 과정이 필요하지 않고, 표면 개질된 활성 산화알루미늄과 활성탄을 이용하여 완전하게 제거할 수 있어 방사성 폐수 및 일반 산업폐수에도 유용하게 적용될 수 있다. 요오드이온($I^-$), 요오드산이온(${IO_3}^-$)의 혼합수용액 중의 각 이온들을 은 처리된 염기성 알루미나와 산성 알루미나를 이용한 흡착제거 방법으로 각각 99% 이상 제거하는 효과를 나타내었다.

Alternative Immunossays

  • Barnard, G.J.R.;Kim, J.B.;Collins, W.P.
    • 한국가축번식학회지
    • /
    • 제9권2호
    • /
    • pp.133-139
    • /
    • 1985
  • An immunoassay may be defined as an analytical procedure involving the competitive reaction between a limiting concentration of specific antibody and two populations of antigen, one of which is labelled or immobillized. The advent of immunoassay has revolutionised our knowledge of reproductive physiology and the practice of veterinary and clinical medicine. Radioimmunoassay (RIA) was the first of these methods to be developed, which meausred the analyte with good sensitivity, accuracy and precision (1,2). The essential components of RIA are:-(i) a limited concentration of antibodies, (ii) a reference preparation, and (iii) an antigen labelled with a radioisotope (usually tritium or iodine-125). Most procedures invelove isolating the antibody-bound fraction and measuring the amount of labelled antigen. Good facilities are available for scintilltion counting, data reduction nd statistical analysis. RIA is undergoing refinement through:-(i) the introduction of new techniques to separate the antibody-bound and free fractions which minimize the misclassification of labelled antigen into these compartments, and the amount of non-specfic binding. (3), (ii) the development of non-extration for the measurement of haptens (4), (iii) the determination of a, pp.rent free (i.e. non-protein bound) analytes (5), and (iv) the use of monoclonal antibodies(6). In 1968, Miles and Hales introduced in important new type of immunoassay which they termed immunora-diometric assay (IRMA) based on t도 use of isotopically labelled specific antibodies(7) in a move from limited to excess reagent systems. The concept of two-site IRMAs (with a capture antibody on a solid-phase, and a second labelled antibody to a different antigenic determinant of the analyte) has enabled the development of more sensitive and less-time consuming methods for the measurement of protein hormones ovar wide concentration of analyte (8). The increasing use of isotopic methos for diverse a, pp.ications has exposed several problems. For example, the radioactive half-life and radiolysis of the labelled reagent limits assay sensitivity and imposes a time limit on the usefulness of a kit. In addition, the potential health hazards associated with the use and disposal of radioactive cmpounds and the solvents and photofluors necessary for liquid scientillation counting are incompatable with the development of extra-laboratory tests. To date, the most practical alternative labels to radioisotopes, for the measurement of analytes in a concentration > 1 ng/ml, are erythrocytes, polystyrene particiles, gold sols, dyes and enzymes or cofactors with a visual or colorimetric end-point(9). Increased sensitivity to<1 pg/ml may be obtained with fluorescent and chemiluminescent labels, or enzymes with a fluorometric, chemiluminometric or bioluminometric end-point. The sensitivity of any immunoassay or immunometric assay depends on the affinity of the antibody-antigen reaction, the specific activity of the label, the precision with which the reagents are manipulated and the nonspecific background signal (10). The sensitivity of a limited reagent system for the measurement of haptens or proteins is mainly dependent upon the affinity of the antibodies and the smalleest amount of reagent that may be manipulated. Consequently, it is difficult in practice to improve on the sensitivity obtained with iodine-125 as the label. Conversely, with excess reagent systems for the measurement of proteins it is theoretically possible to increase assay sensitivity at least 1000 fold with alternative luminescent labels. To date, a 10-fold improvement has been achieved, and attempts are being made to reduce the influence of other variables on the specific signal from the immunoreaction.

  • PDF

갑상선질환(甲狀腺疾患)에 관(關)한 연구(硏究) -20여년간(餘年間)의 핵의학교실업적(核醫學敎室業績)을 중심(中心)으로- (The Study on the Thyroid Disease)

  • 이문호
    • 대한핵의학회지
    • /
    • 제16권2호
    • /
    • pp.1-24
    • /
    • 1982
  • Several recent advances in our knowledge of thyroid physiology have broad application to the diagnosis and management of thyroid disorders. For in the thyroid, more than other endocrine organs, pathophysiology can be translated directly into the diagnosis and management of thyroid disease. Graves' disease is a syndrome including goiter with hyperthyroidism, exophthalmos and dermopathy. The pathogenesis of Graves' disease is not yet clearly identified, but various autoantibodies to the thyroid gland and immunopathologic studies indicate that autoimmune processes are involved in the pathogenesis of the disease. The diagnosis and management of Graves' disease are largely dependent on radionuclide techniques as radioimmunoassay, radioactive iodine therapy and so on. Several laboratory tests are also developed to determine the remission of this disase including TRH stimulation test, $T_3$ suppression test and detection of thyroid stimulating immunoglobulins. Autoimmune thyroiditis is almost certainly a primary immunologic disease and the incidence tends to increase recently, mainly due to the application of biopsy technique in thyroid diseases. Thyroid nodules have been a great challenge to physicians because of the possibility of malignancy. But recently, cytologic examination of thyroid aspirate provides a very simple and also reliable diagnostic method in patients with thyroid nodules. In 163 patients with thyroid nodules, only 19.3% was revealed to be malignant. Therefore cytologic examination of thyroid aspirate and thyroid biopsy should be included in the diagnosis of nodular patients prior to surgical intervention. In this paper, a comprehensive review is presented on the pathogenesis, clinical features, laboratory findings and therapeutic modalities of various thyroid diseases on the basis of over 80 researches performed during the past 20 years at radioisotope clinic, Seoul National University Hospital.

  • PDF

How Computed Tomography Contrast Media and Magnetic Resonance Imaging Contrast Media Affect the Changes of Uptake Counts of 201Tl

  • Lee, Jin-Hyeok;Lee, Hae-Kag;Cho, Jae-Hwan;Cheon, Miju
    • Journal of Magnetics
    • /
    • 제19권4호
    • /
    • pp.372-377
    • /
    • 2014
  • The purpose of the study is to investigate how uptake counts of $^{201}Tl$ of radioisotopes in the human body could change, when taking computed tomography and magnetic resonance imaging right after injecting contrast media. $^{201}Tl$ radioisotope substances of iodine contrast medium, which is a computed tomography contrast medium, and paramagnetic contrast medium, which is an magnetic resonance imaging contrast medium, were used as study materials. First, $^{201}Tl$ was put into 4 cc of normal saline in test tube, and then a computed tomography contrast medium of Iopamidol$^{(R)}$ or Dotarem$^{(R)}$, was put into 2 cc of normal saline in test tube. An magnetic resonance imaging contrast medium of Primovist$^{(R)}$ or Gadovist$^{(R)}$ was also put into 2 cc of normal saline in test tube. Each contrast medium was distributed to make $^{201}Tl$ as 3 mCi, with a total of 4 cc. Gamma camera, low energy high resolution collimator, and pinhole collimator were used to obtain images. The uptake count of $^{201}Tl$ was measured with 1000 frames of images, and obtained after 10 times of repetition. This study revealed that the use of Gadovist$^{(R)}$, which is an magnetic resonance imaging contrast medium, showed the smallest number of uptake count, after measuring $^{201}Tl$ uptake count by low energy high resolution collimator. On the other hand, the use of Iopamidol$^{(R)}$, which is a computed tomography contrast medium, showed the biggest difference in uptake count, when measuring $^{99m}Tc$ uptake count by Pinhole collimator. When examining with gamma camera, using contrast medium and $^{201}Tl$, identifying the changes of uptake count is very important for improving the value of diagnosis.

갑상선 기능저하 음성에 대한 청지각적 및 파열음 분석에 대한 연구 (The Perceptual and Consonant Analysis for the Voice with Hypothyroidism)

  • 한백화;이다해;김준선;홍기환
    • 대한후두음성언어의학회지
    • /
    • 제27권2호
    • /
    • pp.95-101
    • /
    • 2016
  • Background and Objectives : The main purpose of this study is to clarify perceptual and acoustic analysis for the patients with hypothyroidism after thyroidectomy especially focused on the characteristics of speech articulation with special reference to the consonant production. Materials and Methods : The subjects of the research were 40 male and female adults (males : 5, females : 35). They were all received radioactive iodine treatment which after total thyroidectomy. Voice samples were collected during the three stages of after surgery, pre-radioisotope treatment (RIT), and post-RIT. The acoustic analysis was conducted by using Pratt (ver.5.2.21) after measuring voice onset time (VOT). The subjective evaluation of the voices used CAPE-V. Results : A significant decrease in overall severity was displayed in the CAPE-V following RIT. It may be conjectured that this is connected to the change in voice following RIT. The loudness of the sound displayed a significant decrease in the CAPE-V following RIT. It is conjectured that this is connected to the decrease in vocal intensity following RIT. No statistically significant results were revealed for the comparative analysis on the voice onset time (VOT) in all plosives during the three periods. Conclusion : Perceptually, the overall severity of the voice with hypothyroidism was changed significantly before and after RIT. Eventhough VOT were not significantly changed, it tended to decrease VOT in patients with hypothyroidism.

  • PDF

MC-50 싸이클로트론을 이용한 $^{123}I$ 제법 연구 (The Development of Iodine-123 with MC-50 Cyclotron)

  • 서용섭;양승대;전권수;이종두;한현수
    • 대한핵의학회지
    • /
    • 제25권2호
    • /
    • pp.286-293
    • /
    • 1991
  • $^{123}I$, which is applied for the thyroid and other in vivo kinetic study, has a special role in life sciences. The 159 KeV $\gamma-ray$ from $^{123}I$ is almost ideally appropriate for the current imaging instrumentation. Its decay mode (electron capture) and short half-life (13.3 hr) reduced the burden of radiation dose to the patients, and its chemical property makes it easy to synthesize the labelling compounds. In this experiment, the production of $^{123}I$ via the nuclear reaction $^{124}Te(p,2n)^{123}I$ with 28 MeV protons was sutdied. $TeO_2$ is used as a target material, because it has good physical properties. The target was prepared with $TeO_2$ powder and was molten into a ellipsoidal cavity (a=14 mm, b=10 mm, $270.8mg/cm^2$ thick) of pure platinum. The irradiation was carried out in the external proton beam with incident energies range from 28 MeV to 22 MeV, and current was $30{\mu}A$. The loss of $TeO_2$ target was significantly reduced by using $4\pi-cooling$ system in irradiation. The dry distillation method was adopted for the separation of $^{123}I$ from irradiated target, and when it was kept 5 minutes at $780^{\circ}C$, its result was quantitative. The loss of the target material $(TeO_2)$ was below 0.2% for each production run and $^{123}I$ from the dry distillation apparatus was captured with 0.01 N NaOH in $Na^{123}I$ form, then the pH of the solution was adjusted to $7.5\sim9.0$ with HC1/NaOH. The $Na^{123}I$ solution was passed through $0.2{\mu}m$ membrane filter, and sterilized under high pressure and temperature for 30 minutes. The production of $^{123}I$ is acceptable for clinical application based on the quality of USP XXI.

  • PDF

방사성(放射性) 동위원소옥소(同位元素沃素)($^{131}I$)에 의(依)한 갑상선질환(甲狀腺疾患)의 임상적(臨床的) 연구(硏究) - 제 5 보 (第 五 報) - (Clinical Investigation and Treatment of Thyroid Diseases with Radioactive Iodine($^{131}I$))

  • 이문호;고창순;노흥규;이정상;구인서;서환조;이경자;이홍규
    • 대한핵의학회지
    • /
    • 제4권2호
    • /
    • pp.29-39
    • /
    • 1970
  • A summary of the clinical data of the $^{131}I$-thyroid function tests and the therapeutic results of $^{131}I$ among the 2,658 patients of various thyroid diseases treated over the past 10 years from May 1960 to Oct. 1969 at the Radioisotope Clinic and Laboratory, SNUH were presented and dscussed. 1. The patients examined consisted of: 929 cases (34.9%) of diffuse toxic goiter, 762 cases (28.7%) of diffuse nontoxic goiter, 699 cases (26.3%) of nodular nontoxic goiter, 58 cases (2.2%) of nodular toxic goiter and 210. cases (7.9%) of hypothyroidism. 2. There were 300 (11.4%) male and 2358 (88.6%) female, showing a ratio of 1:8. 3. The majority of patients (79.1%) were in the 3rd-5th decades of their lives. 4. The normal ranges, diagonstic values of $^{131}I$ uptake test, 48 hrs, serum activity, BMR and main subjective symptoms of various thyroid diseases were discussed. 5. In the 579 patients among 867 cases with hyperthyroidism treated with $^{131}I$, 47.8% were confirmed to be cured completely after single therapeutic doses. 6. The complications of $^{131}I$ therapy were discussed and myxedema had developed in 6.75% of our patients. 7. The results of $^{131}I$ thyroid function tests were analysed among the 160 cases of thyroid diseases which were confirmed the diagnosis with histopathological measures.

  • PDF

방사성요오드(I-131) 격리병실 치료 관리를 위한 환자의 체외방사선량률과 상주 보호자의 피폭선량평가 (Evaluation of Caregivers' Exposed Dose and Patients' External Dose Rate for Radioactive Iodine (I-131) Therapy Administration in Isolated Ward)

  • 강석진;이두현;소영;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권4호
    • /
    • pp.347-353
    • /
    • 2022
  • In this study, the radiation dose rate was measured by time and distance and evaluated whether radiation dose rate was suitable for domestic and international discharge criteria. In addition, the radiation dose emitted from the patient was measured with a glass dosimeter to evaluate the exposure dose if the caregiver stays in the isolated ward by placing a humanoid phantom instead of the caregiver at a distance of 1 m from the patient, on the second day of treatment. After 23 hours of isolation, the radiation dose rates at a distance of 1 m were 20.54 ± 6.21 µSv/h at 2.96 GBq administration and 27.94 ± 12.33 µSv/h at 3.70 GBq administration. The radiation dose rates at a distance of 1 m were 25.90 ± 2.21 µSv/h when 2.96 GBq was administered and 34.22 ± 10.06 µSv/h when 3.70 GBq was administered after 18 hours of isolation. However, if the isolation period is short may cause unnecessary radiation exposure to the third person. The reading of the attached dosimeter from the morning of the second day of treatment until removal was 0.01 to 0.95 mSv, which is a surface dose determined by the International Commission on Radiation Units and Measurements. And the depth dose was 0.01 to 0.99 mSv. On the second day of treatment, even if the patient caregivers stayed in the isolation ward, the exposure dose of the patient family did not exceed the effective dose limit of 5 mSv recommended by the ICRP and NCRP.

분화된 갑상선암의 수술후 경과관찰에서 I-131 스캔, T1-201 스캔 및 혈청 갑상선 글로불린 농도의 비교 (Comparison of I-131 Scintigraphy, T1-201 Scintigraphy, and Serum Thyroglobulin in the Postoperative Follow-Up of Differentiated Thyroid Cancer)

  • 이현경;송재순;신준재;유계화;차왕기;김은실;김종순
    • 대한핵의학회지
    • /
    • 제31권3호
    • /
    • pp.346-355
    • /
    • 1997
  • 갑상선암은 재발되는 경향이 있으므로 조기에 재발 및 전이를 발견하기 위한 주기적인 경과관찰이 중요하다. T-131 스캔, 혈청 갑상선 글로불린의 측정이 주로 사용되고, T1-201 스캔도 사용되고 있으나 아직 논란이 많으므로 한일 병원에서 분화된 갑상선암 수술후 방사성 옥소치료를 받은 33명의 환자를 대상으로 41증례를 설정하여 각 진단방법의 결과를 비교하였다. I-131 치료적 스캔과 71-201 스캔을 비교한 결과 일치율은 48%(초회치료군 59%, 재치료군 38%) 불과하였다 초회치료군에서는 불일치한 100%(7예) 모두 I-131 치료적 스갠에서 잔여 갑상선조직의 이상 섭취를 보였다. 재 치료군에서는 I-131 치료적 스캔에서 이상섭취가 없이 T1-201 스캔에서만 양성을 보인 6예가 있었고, 이들에서 혈청 갑상선 글로불린이 의의있게 증가된 5예가 있었으나, 모두 반복되는 I-131 치료에도 병소의 소실을 보이지 않았다. I-131 진단적 스캔과 T1-201 스캔의 일치율은 35%(초회치료군 33%, 재치료군 36%)였고, I-131 진단적 스캔에서 발견되지 않은 29%(4예)의 병소를 I-131 치료적 스캔에서 발견할 수 있었다. 결론적으로, 갑상선암 절제술 후 방사성옥소 치료시 I-131 스캔은 잔여 갑상선 조직을 발견하는데 유용하였고, T1-201 스캔은 I-131 스캔에 음성을 보였던 재치료군의 병소를 찾을 수 있었으므로 혈청 갑상선 글로불린 측정과 함께 갑상선암의 추적관찰법으로 유용하였다.

  • PDF

I-131 치료시 환자의 신장기능과 다양한 요인으로 의한 퇴원선량 및 치료병실 오염도의 유의성에 관한 연구 (In the Treatment I-131, the Significance of the Research that the Patient's Discharge Dose and Treatment Ward can Affect a Patient's Kidney Function on the Significance of Various Factors)

  • 임광석;최학기;이기현
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.62-66
    • /
    • 2013
  • 우리나라의 갑상선 암이 증가함에 따라서 갑상선 전 절제술 후 고용량 방사성동위원소 치료를 받는 환자 또한 증가하였다. 하지만 치료를 위해서 사용되는 I-131의 경우 반감기가 8.01일 이며 감마선과 베타선을 내는 특징이 있어 타인에게 줄 수 있는 외부 피폭의 영향을 막기 위해 일정기간 동안 환자가 격리병실에 입원하여 치료를 받게 된다. 이틀 내지 사흘 동안의 격리치료를 한 후 퇴원 전 환자의 몸에서 나오는 방사선량이 법적 기준(70 uSv/h)에 만족하는지 확인한 후 퇴원을 하게 된다. 그리고 다음 환자가 입원 시까지 병실 곳곳의 오염도를 확인 한 후 필요 시에는 제염작업을 수행하게 된다. 우리는 이러한 일련의 과정들 상에서 의료진들이 피폭의 영향을 받게 되는 주 요인으로는 환자의 퇴원선량 확인 및 치료병실의 오염도확인과 제염작업시의 피폭으로 예상된다. 본 연구는 환자의 여러 가지 요소들을(환자의 신기능, 연령, 성별, 초기 투여용량, Tg, Tg-ab)정하고 그 인자들을 통해 환자의 퇴원선량 및 치료병실 오염도에 어떠한 영향을 미치는지 알아보고자 한다. 본원에서 2011년 8월 1일부터 2012년 5월 29일까지 입원하여 고용량방사성 요오드 치료를 받은 환자 151명을 대상으로 실시하였다. 환자의 glomerular filtration rate (GFR) 값이 높을수록 퇴원선량이 낮은 상관관계를 보였다(P<0.001).초기 투여용량의 경우 5.5 GBq (150 mCi) 미만과 5.5 GBq (150 mCi) 이상을 투여 받은 환자군 두 그룹 사이에 평균 퇴원선량을 비교 분석한 결과 5.5 GBq (150 mCi) 미만을 투여 받은 환자 군에서 퇴원선량이 유의하게 낮음을 알 수 있었다($23.95{\pm}10.44uSv/h$, $28.65{\pm}11.79uSv/h$). 연령,성별, Tg, Tg-ab는 환자의 퇴원 선량과 유의한 관계를 보이지 않았다(p>0.05). 그리고 치료병실 오염도는 환자의 퇴원선량과 환자의 신기능과는 유의한 관계를 보이지 않았다 (p>0.05). 병실 오염도의 경우는 입원기간 동안 환자의 생활습관이나 기타 다른 다양한 요인에 의해 영향을 받을 것으로 사료된다. 비록 성별의 집단 간에 따라서 오차가 있다고 여겨지지만 추후 더 많은 환자들을 비교 분석 한다면 도움이 될 것이라고 판단된다. 또한 퇴원선량과 병실의 오염도에 영향을 줄 수 있는 기타 다른 요인들에 대해서도 지속적으로 연구한다면 환자 본인의 피폭뿐만 아니라 가족과 그주변인 의료진들에게도 조금이나마 피폭의 영향을 감소 시킬 수 있을 것이라고 사료된다.

  • PDF