• Title/Summary/Keyword: Involuntary Use

Search Result 27, Processing Time 0.02 seconds

Multimodality and Application Software (다중영상기기의 응용 소프트웨어)

  • Im, Ki-Chun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.2
    • /
    • pp.153-163
    • /
    • 2008
  • Medical imaging modalities to image either anatomical structure or functional processes have developed along somewhat independent paths. Functional images with single photon emission computed tomography (SPECT) and positron emission tomography (PET) are playing an increasingly important role in the diagnosis and staging of malignant disease, image-guided therapy planning, and treatment monitoring. SPECT and PET complement the more conventional anatomic imaging modalities of computed tomography (CT) and magnetic resonance (MR) imaging. When the functional imaging modality was combined with the anatomic imaging modality, the multimodality can help both identify and localize functional abnormalities. Combining PET with a high-resolution anatomical imaging modality such as CT can resolve the localization issue as long as the images from the two modalities are accurately coregistered. Software-based registration techniques have difficulty accounting for differences in patient positioning and involuntary movement of internal organs, often necessitating labor-intensive nonlinear mapping that may not converge to a satisfactory result. These challenges have recently been addressed by the introduction of the combined PET/CT scanner and SPECT/CT scanner, a hardware-oriented approach to image fusion. Combined PET/CT and SPECT/CT devices are playing an increasingly important role in the diagnosis and staging of human disease. The paper will review the development of multi modality instrumentations for clinical use from conception to present-day technology and the application software.

The Development of Tobacco Litigation in USA and it's Impact of Law and Politics in Public Health (미국 담배소송의 변천과 보건법정책 효과)

  • Kim, Un-Mook;Kim, Ji-Hyun
    • The Korean Society of Law and Medicine
    • /
    • v.12 no.1
    • /
    • pp.133-173
    • /
    • 2011
  • Since mid-1960s the reports from the Surgeon General, the World Health Organization, and other health experts state that there is no risk-free level exposure to smoking and secondhand smoke. Tobacco smoke is made up of more than 7,000 chemicals. Hundreds are toxic, and at least 70 are carcinogens. The chemicals in tobacco smoke reach smoker's lungs quickly every time smoker inhale causing damages immediately. Inhaling even the smallest amount of tobacco smoke can also damage smoker's DNA, which can lead to cancers. Smoking is responsible for more than 87% of lung cancers, but there are a host of other chronic diseases directly related to exposure to tobacco smoke. It's also a major cause of heart disease, stroke, aortic aneurysm, peripheral arterial disease and most of the other diseases. In the United States, each year with more than from 440,000 to 520,000 deaths caused by smoking and exposure to involuntary smoke. They conclude that smoking is the single most important source of preventable morbidity and mortality. The United States of America have about 60-year history of tobacco litigation. Tobacco litigation has been an important tool in tobacco control strategies aimed at limiting the activities of tobacco companies and providing redress to people who have become ill as a result of their use of tobacco products. Tobacco litigation is a kind of tort litigation. Quite often, as in the asbestos and other mass tort litigation episodes, tobacco litigation can play an educational role, warning the public about the magnitude of health risks that might otherwise be less clearly perceived. Tobacco litigation allows smokers, their families or other victims of smoking to sue tobacco companies in order to be compensated for the harm they have suffered. Potential benefits of tobacco litigation include compensation for smoking-related damages, strengthening regulatory activity, publicity, documents disclosure and changing tobacco industry behavior. And also tobacco litigation can limit the political activities of tobacco industry, protect human rights of smokers and non-smokers, increase burden to tobacco price-up and enhance the effects of law and politics in public health.

  • PDF

An interpretive comparison of the education as event in The Structure of World History and Anti-Oedipus (『세계사의 구조』와 『안티 오이디푸스』에 나타난 사건적 교육의 해석적 비교)

  • Kim, Young-chul
    • Korean Educational Research Journal
    • /
    • v.42 no.1
    • /
    • pp.1-34
    • /
    • 2021
  • The thesis tries to compare The Structure of World History with Anti-Oedipus in the textual context, and to re-compare in the educational context. I mean by the education an event which contrasts starkly with an essence. It adopts 5W1H, a general reporting form of an accident or event, as the distinctive features at twice comparisons. The purpose of the thesis is not evaluative but interpretive comparison. In the textual context, the thesis discusses, 1) as WHAT, the use of Marx from Kant vs. Nietzsche's point of view, 2) as WHO, the actual subjects of the exchanging human vs. the productive machine, 3) as WHEN/WHERE, the society of the modes of exchange vs. the modes of inscription, 4) as HOW, the revolutionay means of the simultaneous revolution of the world vs. the schizophrenic process, 5) as WHY, the ideal subjects of the associative human vs. the non-human of liberation of desire. In the educational context, the thesis discusses, 1) in the WHAT as educational way, autonomous morality vs. active power, 2) in the WHO as the affirmity of actual subjects, that of the ideal idea vs. that of real power, 3) in the WHEN/WHERE, as the in-between time-space of education, the incommensurable communicative situation of humans vs. the conflictive of machines, 4) in the HOW, as the educational method of achieving the ideal, the involuntary restoration of the already-had ideal vs. the now-have completion and break-through of the schizophrenic process, 5) in the WHY, as the aim of education, cosmopolitan vs. overman.

  • PDF

Relationship between Suppression Strategy of Emotional Expression and Posttraumatic Growth: Serial Multiple Mediating Effects of Self Disclosure on Traumatic Event and Social Support (정서표현억제전략과 외상후 성장의 관계: 외상사건에 대한 자기개방과 사회적 지지의 순차적 다중매개효과)

  • Sull, Keon-Hye;Kim, Min-Hee
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.6
    • /
    • pp.392-403
    • /
    • 2021
  • The purpose of this study was to examine the effect of emotion regulation strategy on posttraumatic growth and to confirm serial multiple mediating effects of self disclosure on a traumatic experience and social support in relationship between suppression strategy of emotional expression and posttraumatic growth. A survey was conducted for adults over the age of 18. Data of 663 adults (222 men, 441 women) were analyzed. According to analysis by using SPSS Process Macro, the less suppression strategy of emotional expression was used, the higher posttraumatic growth was. Simple mediating effect of self disclosure was confirmed between suppression strategy of emotional expression and posttraumatic growth. Serial multiple mediating effects of self disclosure and social support were shown in relationship between suppression strategy of emotional expression and posttraumatic growth. It means that the more people who use less suppression of emotional expression as their emotion regulation strategy, the more they disclose on their traumatic experience, then, they will receive emotional comfort and support from the people around, finally reaching posttraumatic growth. The importance of self disclosure and social support on posttraumatic growth was verified. Counseling intervention method was suggested for involuntary clients who usually suppress emotional expression, to enhance their posttraumatic growth. Lastly, significance and limitations of this study were suggested for follow-up studies.

Fabrication of fixed prosthesis by employing functionally generated path technique and dual scan technique in a tardive dyskinesia patient: a case report (지연성 운동이상증 환자에서 functionally generated path 술식과 이중스캔법을 이용한 고정성 보철물 제작: 증례 보고)

  • Shilpa;Du-Hyeong Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.3
    • /
    • pp.227-233
    • /
    • 2023
  • Tardive dyskinesia is an involuntary neurological movement disorder caused by long-term use of dopamine receptor-blocking drugs leading to dental implications like uncontrolled gnashing and grinding of teeth which in turn imperil the oral rehabilitation procedures as the excessive load increases the risk of prosthesis fracture. A 40-year male with a medical history of tardive dyskinesia visited the hospital to receive oral rehabilitation for missing maxillary anterior teeth. After the oral examination, tooth preparation was done on teeth 13, 15, and 23. After that silicon impression was made and the gypsum cast was digitalized using a desktop scanner and an interim prosthesis was fabricated by milling a resin block. During the try-in, the occlusal one-third of the interim prosthesis was trimmed, and an auto-polymerizing acrylic resin was applied on the occlusal surfaces and inserted in the patient's mouth. Then, the functionally generated path (FGP) of occluding surfaces of opposing arches was traced on the resin surface. When the resin was hardened, the modified interim prosthesis was removed and digitized using an intraoral scanner. The scan image was used in designing the occlusal morphology of definitive prosthesis by modifying the design of the interim prosthesis using the dual scan method. Lastly, a monolithic zirconia prosthesis was fabricated by milling a zirconia block. The definitive prosthesis was delivered reflecting the patient's occlusal scheme. This case report shows that the FGP technique with the dual scan method can help in fabricating fixed prosthesis with harmonious occlusion in a tardive dyskinesia patient.

Comparison of using CBCT with CT Simulator for Radiation dose of Treatment Planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Kim, Dae-Young;Choi, Ji-Won;Cho, Jung-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.742-749
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF