• Title/Summary/Keyword: Inverter device

Search Result 381, Processing Time 0.037 seconds

The Study on Parallel operation of IGBT for the Medium SE the Large capacity Inverter ($\cdot$ 대용량 인버터용 IGBT 병렬 운전 연구)

  • Park G.T.;Yoon J.H.;Jung M.K.;Kim D.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.430-433
    • /
    • 2003
  • IGBTS are widely used for the industrial inverters in the mid power range at low voltage (440V$\~$660V) application. Advantageous features of the device are simple gate drive and high speed switching capability. Due to these advantages the application of IGBTS is enlarging into the high power application. However, to increase the power handling capacity at lower input voltage level, the current rating in each bridge arm must be enlarged. Therefore the parallel operation of IGBT devices is essentially needed. This paper describes the feasible parallel structures of the power circuit for the mid & the high power inverters and introduces the important design condition for the parallel operation of IGBT devices. To verify feasibility of the IGBT parallel operation, the feature of several IGBT devices (EUPEC, SEMIKRON's IGBT) are investigated and the power stacks are implemented and tested with these devices. The experimental results show the good characteristics for the parallel operation of IGBTS.

  • PDF

A Study on the Speed Control of PMSM for Elevator Drive (엘리베이터구동용 영구자석형 동기전동기의 속도제어에 관한 연구)

  • Yu J.S.;Kim L.H.;Choi G.J.;Yoon K.C.;Jung M.T.;Kim Y.C.;Lee S.S.;Won C.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.461-466
    • /
    • 2003
  • This paper presents the speed control of the surface-mounted permanent-magnet synchronous motors (SMPMSM) for the elevator drive. The elevator motor needs to be a compact and slim type. Essentially, the proposed scheme uses a vector control algorithm for a speed and torque control. This system is implemented using a high speed 32-bit DSP (TMS320C31-50), a high-integrated logic device FPGA (EPF10K10-Tl144-3) to design compactly and Inexpensively The proposed scheme is verified through digital simulation and experiments for a three-phase 13.3kW SMPMSM as a MRL(MachineRoomless) elevator motor ill the laboratory. Finally, experiment of the test tower was performed with a 48kW PWM converter-inverter system for a high- speed elevator .

  • PDF

2MHz, 2kW RF Generator (2MHz, 2kW RF 전원장치)

  • Lee J.H.;Choi D.K.;Choi S.D.;Choi H.Y.;Won C,Y.;Kim S.S
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.260-263
    • /
    • 2003
  • When ICP(Inductive Coupled Plasma type etching and wafer manufacturing is being processed in semiconductor process, a noxious gas in PFC and CFC system is generated. Gas cleaning dry scrubber is to remove this noxious gas. This paper describes a power source device, 2MHz switching frequency class 2kW RF Generator, used as a main power source of the gas cleaning dry scrubber. The power stage of DC/DC converter is consist of full bridge type converter with 100kHz switching frequency Power amplifier is push pull type inverter with 2MHz switching frequency, and transmission line transformer. The adequacy of the circuit type and the reliability of generating plasma in various load conditions are verified through 50$\Omega$ dummy load and chamber experiments result.

  • PDF

An Efficient 5-Input Exclusive-OR Circuit Based on Carbon Nanotube FETs

  • Zarhoun, Ronak;Moaiyeri, Mohammad Hossein;Farahani, Samira Shirinabadi;Navi, Keivan
    • ETRI Journal
    • /
    • v.36 no.1
    • /
    • pp.89-98
    • /
    • 2014
  • The integration of digital circuits has a tight relation with the scaling down of silicon technology. The continuous scaling down of the feature size of CMOS devices enters the nanoscale, which results in such destructive effects as short channel effects. Consequently, efforts to replace silicon technology with efficient substitutes have been made. The carbon nanotube field-effect transistor (CNTFET) is one of the most promising replacements for this purpose because of its essential characteristics. Various digital CNTFET-based circuits, such as standard logic cells, have been designed and the results demonstrate improvements in the delay and energy consumption of these circuits. In this paper, a new CNTFET-based 5-input XOR gate based on a novel design method is proposed and simulated using the HSPICE tool based on the compact SPICE model for the CNTFET at the 32-nm technology node. The proposed method leads to improvements in performance and device count compared to the conventional CMOS-style design.

Networked Intelligent Motor-Control Systems Using LonWorks Fieldbus

  • Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.365-370
    • /
    • 2004
  • The integration of intelligent devices, devices-level networks, and software into motor control systems can deliver improved diagnostics, fast warnings for increased system reliability, design flexibility, and simplified wiring. Remote access to motor-control information also affords an opportunity for reduced exposure to hazardous voltage and improved personnel safety during startup and trouble-shooting. This paper presents LonWorks fieldbus networked intelligent induction control system architecture. Experimental bed system with two inverter motor driving system for controlling 1.5kW induction motor is configured for LonWorks networked intelligent motor control. In recent years, MCCs have evolved to include component technologies, such as variable-speed drives, solid-state starters, and electronic overload relays. Integration was accomplished through hardwiring to a programmable logic controller (PLC) or distributed control system (DCS). Devicelevel communication networks brought new possibilities for advanced monitoring, control and diagnostics. This LonWorks network offered the opportunity for greatly simplified wiring, eliminating the bundles of control interwiring and corresponding complex interwiring diagrams. An intelligent MCC connected in device level control network proves users with significant new information for preventing or minimizing downtime. This information includes warnings of abnormal operation, identification of trip causes, automated logging of events, and electronic documentation. In order to show the application of the multi-motors control system, the prototype control system is implemented. This paper is the first step to drive multi-motors with serial communication which can satisfy the real time operation using LonWorks network.

  • PDF

Fault Diagnosis Scheme for Open-Phase Fault of Permanent Magnet Synchronous Motor Drive using Extended Kalman Filter (영구자석 동기전동기 드라이브의 확장형 칼만필터를 이용한 개방성 고장진단 기법)

  • Ahn, Sung-Guk;Park, Byoung-Gun;Kim, Rae-Young;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.191-198
    • /
    • 2011
  • In this paper, the fault diagnosis scheme for PMSM drives has been proposed to maintain control performance under a switch open-phase fault of inverter. When the open-phase fault occurs, the stator resistances of PMSM are estimated by Extended Kalman Filter (EKF) in real time and can appear differently according to the location of fault occurrence to check the fault detection and identification. The control algorithm is configured without the additional device and low cost by adding the existing control program. Also, by using motor parameter the estimated stator resistance value improves the control performance of the controller affected by parameter variation. The feasibility of the proposed fault diagnosis algorithm is validated in simulation and experiment.

Study on the Variation of Reactive Power When Applying the Passive Filter (수동형 필터 적용시 무효전력의 변화에 관한 연구)

  • Kim, Ji-Myeong;Kim, Jong-Gyeum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1626-1631
    • /
    • 2016
  • Generally, the low-voltage customer has been used with a linear load and nonlinear load in the 3-phase 4-wire distribution system. Linear load has usually configured the resistance and inductance, current phase is slower than the voltage phase, so power factor is low. It is required for the power factor correction device prior to the phase of the current than the voltage. The capacitor is connected in parallel to the load in order to ensure a low power factor. Power converter such as an inverter is a typical non-linear load. Non-linear load generates harmonic currents in the energy conversion process. Many electrical equipment may be adversely affected by the harmonic current. There, passive or active filter have been used to reduce these harmonics current. Passive filter consisting of inductor and capacitor generates a reactive power. According to the combination of filter inductor and capacitor, reactive power can be adjusted. In this paper, we analyzed how the combination of inductor and capacitor affects the overall power factor by simulation and measurement.

A Study on SOI-like-bulk CMOS Structure Operating in Low Voltage with Stability (저전압동작에 적절한 SOI-like-bulk CMOS 구조에 관한 연구)

  • Son, Sang-Hee;Jin, Tae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.6
    • /
    • pp.428-435
    • /
    • 1998
  • SOI-like-bulk CMOS device is proposed, which having the advantages of SOI(Silicon On Insulator) and protects short channel effects efficiently with adding partial epitaxial process at standard CMOS process. SOI-like-bulk NMOS and PMOS with 0.25${\mu}{\textrm}{m}$ gate length have designed and optimized through analyzing the characteristics of these devices and applying again to the design of processes. The threshold voltages of the designed NMOS and PMOS are 0.3[V], -0.35[V] respectively and those have shown the stable characteristics under 1.5[V] gate and drain voltages. The leakage current of typical bulk-CMOS increase with shortening the channel length, but the proposed structures on this a study reduce the leakage current and improve the subthreshold characteristics at the same time. In addition, subthreshold swing value, S is 70.91[mV/decade] in SOI-like-bulk NMOS and 63.37[mV/ decade] SOI-like-bulk PMOS. And the characteristics of SOI-like-bulk CMOS are better than those of standard bulk CMOS. To validate the circuit application, CMOS inverter circuit has designed and transient & DC transfer characteristics are analyzed with mixed mode simulation.

  • PDF

A Study of the Power Flow Control Using SSSC (SSSC를 이용한 전력조류제어에 관한 연구)

  • Na, Wan-Ki;Chung, Jai-Kil;Lee, In-Yong;Chung, In-Hark;Lee, Hong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.239-241
    • /
    • 2000
  • This paper describes a modeling of a FACTS(Flexible AC Transmission System) device, namely, SSSC(Static Synchronous Series Compensator) model. The SSSC, a solid-state voltage source inverter coupled with a transformer, is connected in series with a transmission line. SSSC provides controllable compensating voltage, which is in quadrature with the line current, over an capacitive and an inductive range, independently of the magnitude of the line current. This SSSC model is obtained from the injection model for series connected VSC(Voltage Source Converter) by adding a constraint that the injected voltage should be in quadrature with the line current. The paper discusses the basic operating and performance characteristics of the SSSC, and power flow control in power system.

  • PDF

Development of Test Method for Flat Panel Display Life Time Prediction during Atmospheric Particle Exposure (평판디스플레이의 대기중 분진농도에 따른 수명예측 시험방법 개발)

  • Yoo, Dong-Hyun;Lee, Gun-Ho;Choi, Jung-Uk;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.4
    • /
    • pp.45-48
    • /
    • 2013
  • The electronic device, such as flat panel display (FPD), is very important in our life as a means of communication between humans. Liquid crystal display (LCD), which is categorized as a flat panel display, has been used in many display products, especially in TV industry. An LED TV is composed of several electrical components, such as liquid critical module (LCM), analog to digital convertor (AD), power supplier, and inverter board. These modules are very vulnerable to particulate contamination, and causing malfunction or visibility degradation. In this study, we developed a test method for prediction of LCM's lifetime. The test system consists of carbon particle generation flame, dilution system, test chamber, and particle concentration monitoring instrument. Since the carbon particles are the most abundant in the atmosphere and easily absorb light, soot particles are used as a challenging material for this test. The concentration of generated soot particles is set around 4,000,000 #/cc, which is 400 times higher than that of usual atmospheric particles. Through this experiment, we deduced the relationship between the dust concentration and life time of the test specimen.