• 제목/요약/키워드: Invasive surgery

검색결과 1,274건 처리시간 0.029초

원위 경골 골절에서 전외측 잠김 금속판을 사용한 전외측 최소 침습적 금속판 고정술 (Anterolateral Minimally Invasive Plate Osteosynthesis of Distal Tibial Fractures Using an Anterolateral Locking Plate)

  • 서동환;이환희;한영훈;정재중
    • 대한족부족관절학회지
    • /
    • 제24권1호
    • /
    • pp.19-24
    • /
    • 2020
  • Purpose: Anterolateral minimally invasive plate osteosynthesis (MIPO) was performed to treat patients with distal tibial fractures associated with open fractures or extensive soft tissue injuries, which is limited medial MIPO. The treatment results of the anterolateral MIPO technique were evaluated and analyzed. Materials and Methods: Seventeen patients with distal tibial fractures associated with an open fracture or large bullae formation on the distal tibia medial side were treated with anterolateral MIPO using anterolateral locking plates. Within 24 hours of visiting the emergency room, external fixation was applied, and the medial side wound was managed. After damage control, the anterolateral locking plate was applied using an anterolateral MIPO technique. The union time, nonunion, or malunion were evaluated with regular postoperative radiographs. The ankle range of motion, operative time, blood loss, Iowa score, and wound complications were investigated. Results: Radiological evidence of bony union was obtained in all cases. The mean time to union was 16.7 weeks (12~25 weeks). The mean operation time was 44.0 minutes. Regarding the ankle range of motion, the mean dorsiflexion was 15°, and the mean plantarflexion was 35°. Satisfactory results were obtained in 15 out of 17 cases; five results were classified as excellent, four were good, and six were fair. The mean blood loss was 125.2 mL. Two complications were recorded. Conclusion: In distal tibial fractures with severe medial soft tissue damage caused by high-energy trauma, the staged anterolateral MIPO technique using anterolateral locking plates is a useful alternative treatment to achieving optimal wound care, rapid union with biological fixation, and intra-articular reduction.

Characteristics of Active Tuberculosis Patients Requiring Intensive Care Monitoring and Factors Affecting Mortality

  • Filiz, Kosar A.;Levent, Dalar;Emel, Eryuksel;Pelin, Uysal;Turkay, Akbas;Aybuke, Kekecoglu
    • Tuberculosis and Respiratory Diseases
    • /
    • 제79권3호
    • /
    • pp.158-164
    • /
    • 2016
  • Background: One to three percent of cases of acute tuberculosis (TB) require monitoring in the intensive care unit (ICU). The purpose of this study is to establish and determine the mortality rate and discuss the causes of high mortality in these cases, and to evaluate the clinical and laboratory findings of TB patients admitted to the pulmonary ICU. Methods: The data of patients admitted to the ICU of Yedikule Chest Diseases and Chest Surgery Education and Research Hospital due to active TB were retrospectively evaluated. Demographic characteristics, medical history, and clinical and laboratory findings were evaluated. Results: Thirty-five TB patients (27 males) with a median age of 47 years were included, of whom 20 died within 30 days (57%). The Acute Physiology and Chronic Health Evaluation II (APACHE II) and Sequential Organ Failure Assessment (SOFA) scores were significantly higher, and albumin and $PaO_2/FIO_2$ levels were significantly lower, and shock, multiple organ failure, the need for invasive mechanical ventilation and drug resistance were more common in the patients who died. The mortality risk was 7.58 times higher in the patients requiring invasive mechanical ventilation. The SOFA score alone was a significant risk factor affecting survival. Conclusion: The survival rate is low in cases of tuberculosis treated in an ICU. The predictors of mortality include the requirement of invasive mechanical ventilation and multiple organ failure. Another factor specific to TB patients is the presence of drug resistance, which should be taken seriously in countries where there is a high incidence of the disease. Finding new variables that can be established with new prospective studies may help to decrease the high mortality rate.

미세수술을 이용한 하지의 재건시 삼차원 컴퓨터 혈관조영술의 유용성 (Usefullness with 3D CT Angiography in Microsurgical Reconstruction)

  • 성용덕;김효헌
    • Archives of Plastic Surgery
    • /
    • 제33권2호
    • /
    • pp.175-180
    • /
    • 2006
  • Preoperative angiography is frequently used in the planning of microsurgical reconstruction for identification of vascular abnormality that influence the planning of operation. But, recently 3D CT angiography is considered as new technique that can provide detailed information about vascular anatomy as well as soft and bony tissue without the risks of invasive angiography. 3D CT angiograms were performed in 19 patients before microsurgical reconstruction for the lower extremity and hand between May of 2003 and Oct of 2004. Sixteen of the studies were of the donor site and all of 19 studies were of the recipient site. No complications were found from the 3D CT angiograms. In one case of the bone exposed open wound, the injury of anterior tibial artery was identified and the zone of injury was adequately demonstrated. With the improvement in quality of CT imaging, 3D CT angiograms may provide a favorable alternative to invasive angiography. It is capable of providing high-resolution, three dimensional vascular imaging without the need for arterial puncture and prolonged post-procedure observation. The relation among blood vessels, bones, and soft tissue is well demonstrated in 3D CT angiogram. Also The acquisition time and examination cost were considerably lower in comparison with invasive angiography. In conclusion, this study demonstrates that 3D CT angiography may provide accurate, safe, and cost-effective preoperative imaging. The 3D CT angiography with relatively low morbidity, low cost, ease of image acquisition can have an broader role in microsurgical reconstructive surgery.

Preservation of Motion at the Surgical Level after Minimally Invasive Posterior Cervical Foraminotomy

  • Lee, Young-Seok;Kim, Young-Baeg;Park, Seung-Won;Kang, Dong-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권4호
    • /
    • pp.433-440
    • /
    • 2017
  • Objective : Although minimally invasive posterior cervical foraminotomy (MI-PCF) is an established approach for motion preservation, the outcomes are variable among patients. The objective of this study was to identify significant factors that influence motion preservation after MI-PCF. Methods : Forty-eight patients who had undergone MI-PCF between 2004 and 2012 on a total of 70 levels were studied. Cervical parameters measured using plain radiography included C2-7 plumb line, C2-7 Cobb angle, T1 slope, thoracic outlet angle, neck tilt, and disc height before and 24 months after surgery. The ratios of the remaining facet joints after MI-PCF were calculated postoperatively using computed tomography. Changes in the distance between interspinous processes (DISP) and the segmental angle (SA) before and after surgery were also measured. We determined successful motion preservation with changes in DISP of ${\leq}3mm$ and in SA of ${\leq}2^{\circ}$. Results : The differences in preoperative and postoperative DISP and SA after MI-PCF were $0.03{\pm}3.95mm$ and $0.34{\pm}4.46^{\circ}$, respectively, fulfilling the criteria for successful motion preservation. However, the appropriate level of motion preservation is achieved in cases in which changes in preoperative and postoperative DISP and SA motions are 55.7 and 57.1%, respectively. Based on preoperative and postoperative DISP, patients were divided into three groups, and the characteristics of each group were compared. Among these, the only statistically significant factor in motion preservation was preoperative disc height (Pearson's correlation coefficient=0.658, p<0.001). The optimal disc height for motion preservation in regard to DISP ranges from 4.18 to 7.08 mm. Conclusion : MI-PCF is a widely accepted approach for motion preservation, although desirable radiographic outcomes were only achieved in approximately half of the patients who had undergone the procedure. Since disc height appears to be a significant factor in motion preservation, surgeons should consider disc height before performing MI-PCF.

Does the Access Angle Change the Risk of Approach-Related Complications in Minimally Invasive Lateral Lumbar Interbody Fusion? An MRI Study

  • Huang, Chunneng;Xu, Zhengkuan;Li, Fangcai;Chen, Qixin
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권6호
    • /
    • pp.707-715
    • /
    • 2018
  • Objective : To investigate the potential risk of approach-related complications at different access angles in minimally invasive lateral lumbar interbody fusion. Methods : Eighty-six axial magnetic resonance images were obtained to analyze the risk of approach-related complications. The access corridor were simulated at different access angles and the potential risk of neurovascular structure injury was evaluated when the access corridor touching or overlapping the corresponding structures at each angle. Furthermore, the safe corridor length was measured when the corridor width was 18 and 22 mm. Results : When access angle was $0^{\circ}$, the potential risk of ipsilateral nerve roots injury was 54.7% at L4-L5. When access angle was $45^{\circ}$, the potential risk of abdominal aorta, contralateral nerve roots or central canal injury at L4-L5 was 79.1%, 74.4%, and 30.2%, respectively. The length of the 18 mm-wide access corridor was largest at $0^{\circ}$ and it could reach 44.5 mm at L3-L4 and 46.4 mm at L4-L5. While the length of the 22 mm-wide access corridor was 42.3 mm at L3-L4 and 44.1 mm at L4-L5 at $0^{\circ}$. Conclusion : Changes in the access angle would not only affect the ipsilateral neurovascular structures, but also might adversely influence the contralateral neural elements. It should be also noted to surgeons that alteration of the access angle changed the corridor length.

High-Intensity Focused Ultrasound: A Satisfactory, Non-invasive Procedure for Crow's Feet Wrinkles

  • Jung, Gyu Sik;Cho, In Kook;Sung, Hyung Min
    • Medical Lasers
    • /
    • 제8권2호
    • /
    • pp.59-63
    • /
    • 2019
  • Background and Objectives High-intensity focused ultrasound (HIFU) has been developed as an effective, non-invasive, skin-tightening method in response to the increasing demand for improvements in skin laxity and tightening with minimal risk and recovery time. This study evaluated the efficacy and safety of HIFU for non-invasive skin tightening of crow's feet wrinkles, with the aim of determining how long the tightening can be maintained. Materials and Methods Between January and March 2019, 21 female patients with crow's feet wrinkles were treated with HIFU. The treatment involved 200 shots, three times every 2 weeks. Three blinded, experienced plastic surgeons and patients evaluated satisfaction at 2 weeks after the first procedure, 2 weeks after the second procedure, 2 weeks after the third procedure, and 6 weeks after the first procedure based on photographs according to the Global Aesthetic Improvement Scale (GAIS). The Friedman test was used to compare data. Results Of the 21 patients treated using HIFU, one was lost to follow-up for nonstudy-related reasons. Therefore, 20 patients were evaluated and ranged in age from 28 to 48 years. Plastic surgeons' GAIS scores were 2.6, 2.3, 1.7, and 1.3 and patients' GAIS scores were 2.6, 2.2, 1.8, and 1.4 at 2 weeks after the first procedure, 2 weeks after the second procedure, 2 weeks after the third procedure, and 6 weeks after the third procedure. No serious adverse effects were observed. Conclusion The aging face with crow's feet wrinkles can be improved by using HIFU, while minimizing epidermal and dermal injury.

Aortic valve replacement through right anterior mini-thoracotomy in patients with chronic severe aortic regurgitation: a retrospective single-center study

  • Eun Yeung Jung;Ji Eun Im;Ho-Ki Min;Seok Soo Lee
    • Journal of Yeungnam Medical Science
    • /
    • 제41권3호
    • /
    • pp.213-219
    • /
    • 2024
  • Background: Aortic valve replacement (AVR) has recently been performed at many centers using a minimally invasive approach to reduce postoperative mortality, morbidity, and pain. Most previous reports on minimally invasive AVR (MiAVR) have mainly focused on aortic stenosis, and those exclusively dealing with aortic regurgitation (AR) are few. The purpose of this study was to investigate early surgical results and review our experience with patients with chronic severe AR who underwent AVR via right anterior mini-thoracotomy (RAT). Methods: Data were retrospectively collected in this single-center study. Eight patients who underwent RAT AVR between January 2020 and January 2024 were enrolled. Short-term outcomes, including the length of hospital stay, in-hospital mortality, postoperative complications, and echocardiographic data, were analyzed. Results: No in-hospital mortalities were observed. Postoperative atrial fibrillation occurred temporarily in three patients (37.5%). However, none required permanent pacemaker implantation or renal replacement therapy. The median values of ventilator time, length of intensive care unit stay, and hospital stay were 17 hours, 34.5 hours, and 9 days, respectively. Preoperative and postoperative measurements of left ventricular ejection fraction were similar. However, the left ventricular end systolic and diastolic diameters significantly decreased postoperatively from 42 mm to 35.5 mm (p=0.018) and 63 mm to 51 mm (p=0.012), respectively. Conclusion: MiAVR via RAT is a safe and reproducible procedure with acceptable morbidity and complication rates in patients with chronic severe AR. Despite some limitations such as a narrow surgical field and demanding learning curve, MiAVR is a competent method for AR.

Surgical Outcomes of Cardiac Myxoma: Right Minithoracotomy Approach versus Median Sternotomy Approach

  • Lee, Han Pil;Cho, Won Chul;Kim, Joon Bum;Jung, Sung-Ho;Choo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • 제49권5호
    • /
    • pp.356-360
    • /
    • 2016
  • Background: The standard approach in treating cardiac myxoma is the median full sternotomy. With the evolution of surgical techniques, the right minithoracotomy approach has emerged as an alternative method. Since few studies have been published assessing the right minithoracotomy approach, we performed a retrospective study to compare the clinical outcomes of the right minithoracotomy approach with those of the sternotomy approach. Methods: From January 2005 to December 2014, 203 patients underwent resection of a cardiac myxoma. Patients with preexisting cardiac problems were excluded from this study. 146 patients were enrolled in this study; 83 patients were treated using a median sternotomy and 63 patients were treated using a right minithoracotomy. Results: No early mortalities were recorded in either group. Although the cardiopulmonary bypass time and aorta cross-clamp time were significantly shorter in the sternotomy group (p<0.001 and p=0.005), postoperative blood transfusions and arrhythmia events were significantly less common in the thoracotomy group (p=0.004 and p=0.025, respectively). No significant differences were found in the duration of the hospital stay, postoperative intubation time, the duration of the intensive care unit stay, and recurrence. Conclusion: The minimally invasive right minithoracotomy approach is a good alternative method for treating cardiac myxoma because it was found to be associated with a lower incidence of postoperative complications and a shorter postoperative recovery period.

의료용 햅틱 마스터-슬레이브 로봇 시스템 : 실험적 성능 평가 (A Haptic Master-slave Robot System : Experimental Performance Evaluation for Medical Application)

  • 오종석;신원기;프엉박;엄창호;최승복
    • 한국소음진동공학회논문집
    • /
    • 제23권1호
    • /
    • pp.41-48
    • /
    • 2013
  • In this work, 4-DOF ER haptic master is proposed and integrated with a slave robot for minimally invasive surgery(MIS). Using a controllable ER fluid, the haptic master can generate a repulsive force/torque with the 4-DOF motion. For realization of master-slave robot system, the motion command of the haptic master is realized by slave surgery robot. In order to follow the 4-DOF motion of the haptic master, novel mechanism of slave surgery robot with gimbal joint is devised. Accordingly, the haptic master-slave robot system is established by incorporating the slave robot with the haptic master device in which the desired repulsive force/torque and position are transferred to each other via wireless communications. In order to obtain the desired force/torque and position trajectories, tracking controllers for haptic master and slave robot are designed and implemented, respectively. It has been demonstrated that the desired effective torque tracking control performance is well achieved using the proposed haptic master-slave robot system.

의료용 햅틱 마스터-슬레이브 로봇 시스템 : 실험적 성능 평가 (A Haptic Master-Slave Robot System : Experimental Performance Evaluation for Medical Application)

  • 오종석;신원기;프엉박;엄창호;최승복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 추계학술대회 논문집
    • /
    • pp.421-427
    • /
    • 2012
  • In this work, 4 DOF ER haptic master is proposed and integrated with a slave robot for minimally invasive surgery (MIS). Using a controllable ER fluid, the haptic master can generate a repulsive force/torque with the 4-DOF motion. For realization of master-slave robot system, the motion command of the haptic master is realized by slave surgery robot. In order to follow the 4 DOF motion of the haptic master, novel mechanism of slave surgery robot with gimbal joint is devised. Accordingly, the haptic master-slave robot system is established by incorporating the slave robot with the haptic master device in which the desired repulsive force/torque and position are transferred to each other via wireless communications. In order to obtain the desired force/torque and position trajectories, tracking controllers for haptic master and slave robot are designed and implemented, respectively. It has been demonstrated that the desired effective torque tracking control performance is well achieved using the proposed haptic master-slave robot system.

  • PDF