• 제목/요약/키워드: Intrathecal morphine pump

검색결과 6건 처리시간 0.022초

복합부위통증증후군 환자에게 시행한 매몰식 펌프를 이용한 지주막하강 내 약물투입 -증례보고- (Implantable Intrathecal Drug Delivery Pump in Complex Regional Pain Syndrome Patient -A case report-)

  • 서경수;한경림;김세영;박경언;김찬
    • The Korean Journal of Pain
    • /
    • 제22권1호
    • /
    • pp.74-77
    • /
    • 2009
  • Implantable intrathecal pump is one of the therapeutic options for intractable pain. A 24-year-old male with complex regional pain syndrome was suffering from right lower extremity pain. He had all modalities of treatment including spinal cord stimulator. However, his pain had been worse in the past 6 months. His visual analogue pain scale (VAS) was 8-10 and he could not sit or walk. Only opioid was thought to be effective. Then, intrathecal pump was considered. We estimated the minimal effective dose of spinal morphine before implantation. 0.3 mg of morphine was injected intrathecally as a starting dose. Dosage had been increased up to 0.8 mg in 10 days. His VAS score decreased from 8 to 5. He could sleep without pain and walk with crutch. Therefore, intrathecal pump was inserted. He could tolerate to pain. This case suggests that intrathecal morphine delivery can provide effective treatment for intractable non-malignant pain.

척수강 내로 투여한 Epigallocatechin Gallate이 모르핀의 항침해 작용에 대한 내성 발생에 미치는 효과 (The Effect of Intrathecal Epigallocatechin Gallate on the Development of Antinociceptive Tolerance to Morphine)

  • 김웅모;배홍범;최정일
    • The Korean Journal of Pain
    • /
    • 제22권3호
    • /
    • pp.199-205
    • /
    • 2009
  • Background: A major ingredient of green tea is epigallocatechin-3-gallate (EGCG), and this is known to have many beneficial effects for cancer prevention and also on the cardiovascular system and neurodegenerative diseases through its anti-oxidant, anti-angiogenic, anti-inflammatory, lipid-lowering and neuroprotective properties. Its actions on nociception and the spinal nervous system have been examined in only a few studies, and in these studies EGCG showed an antinociceptive effect on inflammatory and neuropathic pain, and a neuroprotective effect in motor neuron disease. This study was performed to investigate the effect of EGCG on acute thermal pain and the development of morphine tolerance at the spinal level. Methods: The experimental subjects were male Sprague-Dawley rats and the Hot-Box test was employed. A single or double-lumen intrathecal catheter was implanted at the lumbar enlargement for drug administration. An osmotic pump was used to infuse morphine for 7 days for induction of morphine tolerance. EGCG was injected repeatedly for 7 days at twice a day through the intrathecal catheter. Results: Intrathecal EGCG increased the paw withdrawal latency (PWL) after repeated administration for 7 days at twice a day, but this did not happen with administering on single bolus injection of EGCG. In addition, the antinociceptive effect of intrathecal morphine was not affected by co-administration with EGCG. A continuous 7-day infusion of morphine caused a significant decrease of the PWL in the control group (M + S, morphine plus saline). In contrast, intrathecal EGCG injection over 7 days blocked the decrease of the PWL in the experiment group (M + E, morphine plus EGCG). Conclusions: Intrathecal ECGC produced a weak antinociceptive effect for acute thermal pain, but it did not change the morphine's analgesic effect. However, the development of antinociceptive tolerance to morphine was attenuated by administering intrathecal EGCG.

Catheter Obstruction of Intrathecal Drug Administration System -A Case Report-

  • Rhee, Seok-Myeon;Choi, Eun-Joo;Lee, Pyung-Bok;Nahm, Francis Sahn-Gun
    • The Korean Journal of Pain
    • /
    • 제25권1호
    • /
    • pp.47-51
    • /
    • 2012
  • Intrathecal drug administration system (ITDAS) can reduce the side effects while increasing the effectiveness of opioids compared to systemic opioid administration. Therefore, the use of ITDAS has increased in the management of cancer pain and chronic intractable pain. Catheter obstruction is a serious complication of ITDAS. Here, we present a case of catheter obstruction by a mass formed at the side hole and in the lumen. A 37-year-old man suffering from failed back surgery syndrome received an ITDAS implantation, and the ITDAS was refilled with morphine every 3 months. When the patient visited the hospital 18 months after ITDAS implantation for a refill, the amount of delivered morphine sulfate was much less than expected. Movement of the pump rotor was examined with fluoroscopy; however, it was normal. CSF aspiration through the catheter access port was impossible. When the intrathecal catheter was removed, we observed that the side hole and lumen of the catheter was plugged.

Retrospective analysis of the financial break-even point for intrathecal morphine pump use in Korea

  • Kim, Eun Kyoung;Shin, Ji Yeon;Castaneda, Anyela Marcela;Lee, Seung Jae;Yoon, Hyun Kyu;Kim, Yong Chul;Moon, Jee Youn
    • The Korean Journal of Pain
    • /
    • 제30권4호
    • /
    • pp.272-280
    • /
    • 2017
  • Background: The high cost of intrathecal morphine pump (ITMP) implantation may be the main obstacle to its use. Since July 2014, the Korean national health insurance (NHI) program began paying 50% of the ITMP implantation cost in select refractory chronic pain patients. The aims of this study were to investigate the financial break-even point and patients' satisfaction in patients with ITMP treatment after the initiation of the NHI reimbursement. Methods: We collected data retrospectively or via direct phone calls to patients who underwent ITMP implantation at a single university-based tertiary hospital between July 2014 and May 2016. Pain severity, changes in the morphine equivalent daily dosage (MEDD), any adverse events, and patients' satisfaction were determined. We calculated the financial break-even point of ITMP implantation via investigating the patient's actual medical costs and insurance information. Results: During the studied period, 23 patients received ITMP implantation, and 20 patients were included in our study. Scores on an 11-point numeric rating scale (NRS) for pain were significantly reduced compared to the baseline value (P < 0.001). The MEDD before ITMP implantation was 0.59 [IQR: 0.55-0.82]. The total MEDD increased steadily to 0.77 [IQR: 0.53-1.08] at 1 year, which was 126% of the baseline (P < 0.001). More than a half (60%) responded that the ITMP therapy was somewhat satisfying. The financial break-even point was 28 months for ITMP treatment after the NHI reimbursement policy. Conclusions: ITMP provided effective chronic pain management with improved satisfaction and reasonable financial break-even point of 28 months with 50% financial coverage by NHI program.

척수강 내 약물 주입기의 이식 -증례보고- (Implantation of an Intrathecal Drug Administration System -A report of two cases-)

  • 이상진;남상건;김장현;김현주;이상철;김용철
    • The Korean Journal of Pain
    • /
    • 제22권1호
    • /
    • pp.68-73
    • /
    • 2009
  • Opioids profoundly inhibit evoked discharges of spinal nociceptive neurons, thereby inhibiting the transmission of pain. Intrathecal administration of opioids using implantable continuous infusion systems is an effective method of pain relief when other treatments have failed, as well as for patients with adequate analgesia on high dose therapy that produces unacceptable side effects. We report two cases of intrathecal pump implantation performed in patients suffering from intractable chronic pain. A test dose of 3 mg morphine was injected into the epidural space. No side effects were noted and patients experienced considerable pain relief. Implantation was performed one day after the test. The initial intrathecal morphine delivery dose was half of the equivalent dose of daily oral intake opioids and the infusion rate was increased gradually under close observation for opioid side effects. Two days post-implantation, both patients were discharged without any complications.

Epidural Infusion of Morphine and Levobupivacaine through a Subcutaneous Port for Cancer Pain Management

  • Heo, Bong Ha;Pyeon, Tae Hee;Lee, Hyung Gon;Kim, Woong Mo;Choi, Jeong Il;Yoon, Myung Ha
    • The Korean Journal of Pain
    • /
    • 제27권2호
    • /
    • pp.139-144
    • /
    • 2014
  • Background: To manage intractable cancer pain, an alternative to systemic analgesics is neuraxial analgesia. In long-term treatment, intrathecal administration could provide a more satisfactory pain relief with lower doses of analgesics and fewer side-effects than that of epidural administration. However, implantable drug delivery systems using intrathecal pumps in Korea are very expensive. Considering cost-effectiveness, we performed epidural analgesia as an alternative to intrathecal analgesia. Methods: We retrospectively investigated the efficacy, side effects, and complications of epidural morphine and local anesthetic administration through epidural catheters connected to a subcutaneous injection port in 29 Korean terminal cancer patients. Patient demographic data, the duration of epidural administration, preoperative numerical pain rating scales (NRS), side effects and complications related to the epidural catheterization and the drugs, and the numerical pain rating scales on the 1st, 3rd, 7th and 30th postoperative days were determined from the medical records. Results: The average score for the numerical pain rating scales for the 29 patients decreased from $7{\pm}1.0$ at baseline to $3.6{\pm}1.4$ on postoperative day 1 (P < 0.001). A similar decrease in pain intensity was maintained for 30 days (P < 0.001). Nausea and vomiting were the most frequently reported side effects of the epidural analgesia and two patients (6.9%) experienced paresthesia. Conclusions: Epidural morphine and local anesthetic infusion with a subcutaneous pump seems to have an acceptable risk-benefit ratio and allows a high degree of autonomy to patients with cancer pain.